• 제목/요약/키워드: Ammonia-water

검색결과 948건 처리시간 0.027초

고온호기성 소화공정 배가스 처리를 위한 바이오필터 성능평가 (Performance Evaluation of Biofilter Treating Autothermal Thermophilic Aerobic Digestion Offgas)

  • 배병욱;최기승
    • 한국물환경학회지
    • /
    • 제26권5호
    • /
    • pp.732-739
    • /
    • 2010
  • Two combined autothermal thermophilic aerobic digestion (ATAD) and biofilter (BF) systems were operated to treat the piggery wastewater and the ammonia offgas. Experimental results indicated that the organic removal efficiency of ATAD-2, operated with oxygen, was higher than that of ATAD-1, operated with air. The concentration of ammonia in ATAD-2 offgas was higher compared to ATAD-1 offgas, but the total amount of ammonia produced from ATAD-2 was less than that from ATAD-1 due to the lower oxygen flowrate. The ammonia gas produced from both ATAD reactors was successfully removed by the BF. The BF-1, connected with ATAD-1, removed 93% of ammonia at the loading rate of $9.4g\;NH_3-N/m^3/hr$. The BF-2, connected with ATAD-2, removed 95% of ammonia gas at the loading rate of $8.1g\;NH_3-N/m^3/hr$. As the nitrification process continued, pH value of recirculating solution continuously decreased due to the accumulation of nitrate. When the ammonia loading rate was less than $22.7g\;NH_3-N/m^3/h$, the proper replacing cycle of recirculating solution was in the range of 10 to 11 days. Almost 90% of total mass of nitrogen fed into the each BF was confirmed from the mass balance on nitrogen.

정수슬러지 유래 흡착제와 첨착활성탄의 암모니아 및 포름알데히드 기체 흡착 성능 비교 (Comparison of Adsorption Performance of Ammonia and Formaldehyde Gas Using Adsorbents Prepared from Water Treatment Sludge and Impregnated Activated Carbon)

  • 이철호;박나영;김고운;전종기
    • 공업화학
    • /
    • 제27권1호
    • /
    • pp.62-67
    • /
    • 2016
  • 본 연구에서는 정수슬러지를 원료로 사용하여 펠렛형 흡착제를 제조하고 질소흡착법, XRD, XRF 및 암모니아 승온탈착법 등을 사용하여 물리 화학적 특성을 분석하였다. 정수슬러지 유래 펠렛형 흡착제와 첨착활성탄의 암모니아 및 포름알데히드 기체의 흡착 성능을 비교하였다. 정수슬러지로부터 제조된 펠렛형 흡착제는 첨착활성탄보다 표면적과 기공부피는 훨씬 작지만 암모니아를 훨씬 더 많이 흡착할 수 있었다. 이는 정수슬러지로부터 제조된 펠렛형 흡착제 표면에 산점이 훨씬 더 많이 분포해 있어서 화학흡착에 의해 암모니아를 흡착하기 때문이다. 반면에, 산성가스인 포름알데히드 가스 흡착의 경우는 넓은 표면적과 발달된 기공으로 인하여 첨착활성탄의 흡착성능이 정수슬러지로부터 제조된 펠렛형 흡착제에 비해 훨씬 우수하였다.

암모니아수 흡수제를 이용한 이산화탄소 제거 공정에서 침전생성이 조업영역에 미치는 영향 (Effect of Precipitation on Operation Range of the CO2 Capture Process using Ammonia Water Absorbent)

  • 유정균;박호석;홍원희;박종기;김종남
    • Korean Chemical Engineering Research
    • /
    • 제45권3호
    • /
    • pp.258-263
    • /
    • 2007
  • 배가스 이산화탄소 처리를 위한 화학적 흡수공정의 새로운 흡수제로서 암모니아수의 적용 가능성을 고찰하였다. 이산화탄소 흡수용량과 침전 발생의 관점에서 적합한 암모니아수 흡수제 농도와 $CO_2$ 부하(loading, $molCO_2/molNH_3$)를 결정하였다. 이를 위하여 전해액에 대한 Pitzer 모델을 이용하여 암모니아 흡수제 농도에 따른 흡수용량과 침전 발생여부를 계산하였다. $5\;molNH_3/kgH_2O$ 이상의 암모니아수 흡수제를 사용하여 기존 아민류 흡수제 이상의 흡수용량은 얻을 수 있었다. 각 암모니아 흡수제 농도에서 $NH_4HCO_3$ 침전의 발생으로 인하여 조업이 제약되는 $CO_2$ 부하를 구하였다. $5{\sim}14\;molNH_3/kgH_2O$의 암모니아 흡수제는 293, 313 K에서 $CO_2$ 부하 0.5 이상에서 침전이 발행하였다. 침전 생성 $CO_2$ 부하값 이하로 흡수탑을 조업함으로써 고농도 암모니아 흡수제가 배가스 $CO_2$ 처리 공정에 사용될 수 있음을 알 수 있었다. 흡수용량과 침전발생을 고려하여 배가스 이산화탄소 처리를 위한 흡수제 최적온도는 암모니아수 농도에 따라 297~312 K이었다.

Determination of Ammonia-N in Environmental Water by Air-segmented FIA

  • Feng, Yong-Lai;Tian, Li-Ching;Wang, Wei;Wu, Qiao-Znen
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.787-792
    • /
    • 1995
  • A method for determination of ammonia-N in environmental water by air-segmented flow injection analysis using the colour reaction of phenol and sodium hypochlorite with ammonia was described in this paper. When the reaction temperature is $70^{\circ}C$ and the reaction residence time is 5 minutes, a sample frequency of $60-90h^{-1}$ can be achieved. The detection limit and relative deviation are $0.05mg.ml^{-1}$ and 4%, respectively. The recovery of this method is 96 - 110%, and the determination results of the method are greatly agreement with standard colorimetric method.

  • PDF

공냉형 암모니아/물 GAX 흡수식 냉동 사이클의 수치 해석 (A Numerical Simulation of Air-Cooled Ammonia/Water GAX Absorption Cooling Cycle)

  • 정시영
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.488-500
    • /
    • 1995
  • An air-cooled ammonia/water GAX(Generator-Absorber heat eXchange) absorption cooling cycle is proposed and its performance is numerically evaluated. It is shown that the performance of the system is greatly dependent on the quality of the refrigerant leaving the evaporator. For any refrigerant concentration in the investigated range(99.1~99.9% ammonia), the cycle COP(coefficient of performance) reaches the highest value, when some amount(about 7%) of refrigerant evaporates in the refrigerant heat exchanger. Among temperature differences in various heat exchangers, the temperature difference between GAX-absorber and the GAX-generator shows the greatest effect on the system performance, whereas pressure losses cause no significant decrease in COP. The system COP increases almost linearly with increasing evaporator temperature, decreasing absorber temperature or decreasing condenser temperature. If both absorber and condenser temperature increase simultaneously, the decrease in the COP becomes larger.

  • PDF

암모니아-물 흡수식 시스템에서 단열정류기의 물질 전달 (Mass transfer in adiabatic rectifier of ammonia-water absorption system)

  • 김병주
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.414-421
    • /
    • 1999
  • Falling film rectification involves simultaneous heat and mass transfer between vapor and liquid interface. In the present work, the adiabatic rectification process of ammonia-water vapor on the vertical plate was investigated. The continuity, momentum, energy and diffusion equations for the solution film and vapor mixture were formulated in integral forms and solved numerically. The model could predict the film thickness, the pressure gradient, and the mass transfer rate. The effects of Reynolds number and ammonia concentration of solution and vapor mixture, rectifier length, and the enhancement of mass transfer in each phases were investigated. The stripping of water in vapor mixture occurred new the entrance of ammonia solution, which imposed the proper size of an adiabatic rectifier. Rectifier efficiency increased as film Reynolds number increased and as vapor mixture Reynolds number decreased. The improvement of rectifier efficiency was significant with the enhancement of mass transfer in falling film.

  • PDF

Mass Transfer in an Adiabatic Rectifier of Ammonia-Water Absorption System

  • Kim, Byong-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.69-79
    • /
    • 2000
  • Falling film rectification involves simultaneous heat and mass transfer between vapor and solution film. In the present work, the adiabatic rectification process of ammonia-water vapor by the falling solution film on the vertical plate was investigated. The continuity momentum, energy and diffusion equations for the solution film and the vapor mixture were formulated in integral forms and solved numerically, The model could predict the film thickness, the pressure gradient, and the mass transfer rate. The effects of Reynolds number and ammonia concentration of solution and vapor mixture, rectifier length, and the enhancement of mass transfer coefficient in each phases were investigated. The stripping of water in vapor mixture occurred near the entrance of ammonia solution, which imposed the proper size of an adiabatic rectifier. Rectifier efficiency increased as film Reynolds number increased and as vapor mixture Reynolds number decreased. The improvement of rectifier efficiency was significant with the enhancement of mass transfer coefficient in falling film.

  • PDF

유기랭킨사이클과 암모니아-물 랭킨사이클의 열역학적 성능의 비교 해석 (Comparative Thermodynamic Analysis of Organic Rankine Cycle and Ammonia-Water Rankine Cycle)

  • 김경훈;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제27권5호
    • /
    • pp.597-603
    • /
    • 2016
  • In this paper a comparative thermodynamics analysis is carried out for organic Rankine cycle (ORC) and ammonia-water Rankine cycle (AWRC) utilizing low-grade heat sources. Effects of the working fluid, ammonia concentration, and turbine inlet pressure are systematically investigated on the system performance such as mass flow rate, pressure ratio, turbine-exit volume flow, and net power production as well as the thermal efficiency. Results show that ORC with a proper working fluid shows higher thermal efficiency than AWRC, however, AWRC shows lower mass flow rate of working fluid and lower pressure ratio of expander than ORC.

견직물의 긴장과 무긴장머어서화 가공에 관한 연구 (A Study on the Tension and Slack Mercerization of Cotton Fabrics)

  • Chul-Ho, Choi;Chan-Min, Lee
    • 한국염색가공학회지
    • /
    • 제2권3호
    • /
    • pp.51-58
    • /
    • 1990
  • Cotton fabrics were mercerized in ammonia water, sodium hydroxide and mixture of ammonia/sodium hydroxide, slack and under tension. X-ray and infrared spectra analyses were used to measure crystallinity of treated cottons. Changes due to swelling, which took place in the accessible regions were determined by moisture regain and dye adsorption. In addition to that crease recovery was compared mutually, and breaking strength-elongation compared, too. Both ammonia water and caustic treatments produced changes in morphology (swollen fibers, decrease in convolutions) and in fine structure of the cellulose (increase accessibility as measured by increased moisture regain, dye adsorption). X-ray diffraction showed partial recrystallization into cellulose III lattic after tension treatment with ammonia water. Both reagents produced increased cotton elongation-at-break with slack mercerization, increased cotton breaking strength with tension mercerization, and increased moisture regain or dye adsorption with slack mercerization.

  • PDF

Vertical Diffusion of Ammonia Into Amorphous Ice Sturcture

  • 김영순;문의성;강헌
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.280-280
    • /
    • 2012
  • We examined ammonia diffusion on the surface of amorphous ice film through the measurement of decreasing residual quantity of $NH_3$ molecules compared to $H_2O$. The populations of $NH_3$ molecules on the surface of amorphous ice were monitored by using the techniques of temperature programmed reactive ion scattering (TPRIS) method. The ratio of intensity between ammonia and water was examined as a function of time at controlled temperature. When ammonia molecules were externally added onto an ice film at a temperature of 80 K, ammonia coverage with regard to ice was 0.12-0.16 ML. The intensity of ammonia molecules on the surface of ice decreased as time increased and the extent of decreased intensity of ammonia increased as controlled temperature increased. Moreover, energy barrier was estimated to be $51kJmol^{-1}$ on amorphous ice film. The results of the experiment indicate that ammonia molecules have a property of vertical diffusion into amorphous ice and the energy barrier of ammonia diffusion into bulk of ice is higher than that of hydrogen bonding.

  • PDF