• Title/Summary/Keyword: Ammonia/water solution

Search Result 128, Processing Time 0.029 seconds

Continuous Decomposition of Ammonia by a Multi Cell-Stacked Electrolyzer with a Self-pH Adjustment Function (자체 pH 조정 기능을 갖는 다단 전해조에 의한 암모니아의 연속식 분해)

  • Kim, Kwang-Wook;Kim, Young-Jun;Kim, In-Tae;Park, Geun-Il;Lee, Eil-Hee
    • Korean Chemical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.352-359
    • /
    • 2005
  • This work has studied the changes of pH in both of anodic and cathodic chambers of a divided cell due to the electrolytic split of water during the ammonia decomposition to nitrogen, and has studied the continuous decomposition characteristics of ammonia in a multi-cell stacked electrolyzer. The electrolytic decomposition of ammonia was much affected by the change of pH of ammonia solution which was caused by the water split reactions. The water split reaction occurred at pH of less than 8 in the anodic chamber with producing proton ions, and occurred at pH of more than 11 in the cathodic chamber with producing hydroxyl ions. The pH of the anodic chamber using an anion exchange membrane was sustained to be higher than that using a cation exchange membrane, which resulted in the higher decomposition of ammonia in the anodic chamber. By using the electrolytic characteristics of the divided cell, a continuous electrolyzer with a self-pH adjustment function was newly devised, where a portion of the ammonia solution from a pHadjustment tank was circulated through the cathodic chambers of the electrolyzer. It enhanced the pH of the ammonia solution fed from the pH-adjustment tank into the anodic chambers of the electrolyzer, which caused a higher decomposition yield of ammonia. And then, based on the electrolyzer, a salt-free ammonia decomposition process was suggested. In that process, ammonia solution could be continuously decomposed into the environmentally-harmless nitrogen gas up to 83%, when chloride ion was added into the ammonia solution.

Heat and Mass Transfer Characteristics of a Falling Film Ammonia Absorber with Respect to the Vapor Flow Direction (유하액막식 암모니아 흡수기에서 증기 유동방향에 따른 열 및 물질전달 특성)

  • 권경민;정시영;김병주;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.16-25
    • /
    • 2004
  • The flow and heat/mass transfer in the falling-film of a heat exchanger can be influenced by the motion of the surrounding refrigerant vapor. In this study, the effect of the vapor flow direction on the absorption heat transfer has been investigated for a falling-film helical coil which is frequently used as the absorber of ammonia/water absorption refrigerators. The experiments were carried out for different solution concentration. The heat and mass transfer performance was measured for both parallel and counter-current flow. The effect of vapor flow on the heat and mass transfer is found to be increased with decreasing solution concentration. In the experiments with low solution concentration, whose vapor specific volume is great, the counter-current flow of vapor resulted in uneven distribution of falling-film and reduced the heat transfer performance of the absorber. The direction of the vapor flow hardly affected the thermal performance as the solution concentration became stronger since the specific volume of the ammonia/water vapor was much smaller than that of the water vapor.

Dynamic Model of a Vertical Tube Absorber for Ammonia/water Absorption Refrigerators (암모니아/물 흡수식 냉동기의 수직원관형 흡수기의 동적 모델)

  • 문현석;정은수;김병주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.844-853
    • /
    • 2002
  • A dynamic model which simulates the coupled heat and mass transfer within a vertical tube absorber was developed. The liquid film is a binary mixture of two components, and both of these components are present in the vapor phase. The pressure, concentration, temperature and mass flow rate of the vapor are obtained by assuming that the pressure is uniform within an absorber. The model was applied to an absorber for an ammonia/water absorption refrigerator. The transient behaviors of the pressure, the outlet temperature and the concentration of the solution and the cooling water outlet temperature on a step change at the absorber inlet of the cooling water temperature, the vapor mass flow rate and the concentration of the solution were shown.

Performance Evaluation of Biofilter Treating Autothermal Thermophilic Aerobic Digestion Offgas (고온호기성 소화공정 배가스 처리를 위한 바이오필터 성능평가)

  • Bae, Byung-Uk;Choi, Ki-Seung
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.732-739
    • /
    • 2010
  • Two combined autothermal thermophilic aerobic digestion (ATAD) and biofilter (BF) systems were operated to treat the piggery wastewater and the ammonia offgas. Experimental results indicated that the organic removal efficiency of ATAD-2, operated with oxygen, was higher than that of ATAD-1, operated with air. The concentration of ammonia in ATAD-2 offgas was higher compared to ATAD-1 offgas, but the total amount of ammonia produced from ATAD-2 was less than that from ATAD-1 due to the lower oxygen flowrate. The ammonia gas produced from both ATAD reactors was successfully removed by the BF. The BF-1, connected with ATAD-1, removed 93% of ammonia at the loading rate of $9.4g\;NH_3-N/m^3/hr$. The BF-2, connected with ATAD-2, removed 95% of ammonia gas at the loading rate of $8.1g\;NH_3-N/m^3/hr$. As the nitrification process continued, pH value of recirculating solution continuously decreased due to the accumulation of nitrate. When the ammonia loading rate was less than $22.7g\;NH_3-N/m^3/h$, the proper replacing cycle of recirculating solution was in the range of 10 to 11 days. Almost 90% of total mass of nitrogen fed into the each BF was confirmed from the mass balance on nitrogen.

Modeling of Ammonia Mass Transfer Using a Hollow Fiber Membrane Contactor (중공사막 접촉기를 이용한 암모니아 물질전달 모델링)

  • Oh, Dae-Yang;Jeong, Joo-Young;Choi, Won-Ho;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.503-510
    • /
    • 2011
  • Ammonia in water which is toxic to human, its concentration is regulated below 0.5 mg/L in drinking water. Current study aimed to develop appropriate models for ammonia stripping using hollow fiber membrane contactor. Two different models were developed during the study. Model 1 was assumed only free ammonia ($NH_3$) transfer in stripping process, whereas the Model 2 was assumed with total ammonia ($NH_3+{NH_4}^+$) transfer. Ammonium chloride ($NH_4CI$), sodium hydroxide(NaOH) were used to make ammonia solution, which was concentration of 25 mg as N/L at a pH of 10.5. The experimental conditions were such that, the liquid flow was in tube-side in upward direction and t he gas flow was on shell-side in downward direction a t room temperature. The experimental and modeling results showed that marginal difference were observed at low gas flux. However the difference between the both models and experimental value were increased when the gas flux was increased. The study concludes that the Model 1 with free ammonia is more appropriate when both models were compared and useful in ammonia stripping process at low gas flux.

Effects of pH Control Agent and Co-Precipitate Washing Agent on Nickel Ferrite Preparation by Co-Precipitation Method (공침법에 의한 Nickel Ferrite의 분말제조에서 pH-조절제 및 공침물-세척제의 영향)

  • Jeong, Hong-Ho;Seong, Gi-Ung
    • Korean Journal of Materials Research
    • /
    • v.10 no.6
    • /
    • pp.445-449
    • /
    • 2000
  • Nickel ferrite $(Ni_{0.75}Fe_{2.25}O_4$ was synthesized by co-precipitation method in order to investigate its behavior under conditions of the reactor coolant system in pressurized light water nuclear power plants. Ammonia or potassium carbonate was used as a solution pH control agent, and aqueous ammonia or potassium carbonate solution or secondary distilled water was used as a co-precipitate washing agent. The effects of the pH control agent and the co-precipitate washing agent on the production yield on the basis of the Ni/Fe molar ratio and the particle characteristics of final products were investigated by XRD, SEM, EDX and XPS. The production yield was almost congruent with that of the initial aqueous mixture in case of using potassium carbonate as a pH control agent, while in case of using ammonia, it was quite changed. The difference seemed to be due to the effects of $Ni^{2+}{\leftarrow}NH_3$complexation in the aqueous solution and of the pH of co-precipitate washing agent.

  • PDF

Effects of Ammonia Swelling Treatment in Carboxymethylation of Domestic Kraft Pulp on Characteristics of Corboxymethylcellulose(CMC) and CMC Solution (국산(國産) 크라프트 펄프의 카르복시메틸화시(化時) 암모니아 팽윤처리(膨潤處理)가 카르복시메틸셀룰로오스와 카르복시메틸셀룰로오스 용액(溶液)의 특성(特性)에 미치는 효과(效果))

  • Ahn, Byoung-Kuk;Ahn, Won-Yung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.25-35
    • /
    • 1990
  • To investigate the effects of swelling treatment by ammonia on characteristics of carboxymethy1cellulose(CMC) and CMC solution, the domestic kraft pulp pretreated with 5%, 10%, 15% and 20% $NH_4OH$ solution, was carboxymethylated by the standard method, and then the CMC prepared was tested. The physical properties of CMC and CMC solution, such as degree of substitution, transparency. viscosity, weight increase and solubility, were measured, and the comparison with commercial domestic CMC used as a food additive was done. The results obtained were as follows; 1. In CMC manufactured by standard solvent method, hardwood bleached kraft pulp(LBKP) was more substituted than safwood bleached kraft pulp(NBKP), and viscosity of NBKP was higher than that of LBKP. 2. When ammonia swelling treatment was done, degree of substitution gradually decreased with increasing concentration of $NH_4OH$, and degree of substitution of LBKP decreased with a larger range than that of NBKP. 3. When ammonia swelling treatment was done. transparency of CMC solution from LBKP was hardly effected, but in case of NBKP gradually increased with increasing concentration of $NH_4OH$. 4. When ammonia swelling treatment was done, viscosity of CMC solution was higher than that of CMC solution without ammonia swelling treatment. Especially, CMC of high viscosity could be manufactured in 5%, 10% concentration levels of $NH_4OH$. 5. In CMC manufactured from domestic NBKP, CMC at the range of 0.40 to 0.50 in DS was dispersed easily and quickly dissolved, and CMC at more than 0.50 in DS was dispersed slowly in water solution. 6. In comparison with commercial domestic CMC used as a food additive, CMC manufactured from domestic NBKP was higher in DS, and was lower in viscosity and transparency.

  • PDF

Ammonia as Extractant and Reactant for Ginsenosides

  • Cho In-Ho;Hohaus Eberhard;Lentz Harro
    • Proceedings of the Ginseng society Conference
    • /
    • 2002.10a
    • /
    • pp.486-490
    • /
    • 2002
  • In different approaches ginsenosides were extracted from Korean ginseng roots by ammonia and for comparison with methanol-water and water. The extracts have been analyzed qualitatively and quantitatively to evaluate yield and selectivity of extractions of ginsenosides. Water supplied the lowest yield. The yields of extracts with liquid ammonia were higher than those with methanol-water. However, this is partly due to the conversion of malonyl ginsenoside to normal ginsenosides by ammonia. It was proved by HPLC that malonyl-ginsenosides $m-Rb_1,\;m-Rb_2,$ m-Rc and m-Rd were converted to the corresponding neutral ginsenosides. Furthermore, ginsenosides from ginseng roots were extracted by alkaline methanol-water $(60\%)$ solutions. Alternatively, the extracts of the methanol-water $(60\%)$ extraction were treated with sodium hydroxide solution. Both methods also convert the malonyl-ginsenosides to neutral ginsenosides.

  • PDF

Improvement of the Ammonia Analysis by the Phenate Method in Water and Wastewater

  • Park, Ga-Eun;Oh, Ha-Na;Ahn, Sam-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.9
    • /
    • pp.2032-2038
    • /
    • 2009
  • The amount of phenol and NaOH for the colorimetric determination of ammonia in Korean standard methods (KSM) is found to be highly excessive compared to the standard methods of several other countries. The absorbance of indophenol formed by the Berthelot reaction for ammonia analysis was measured under the various reaction conditions classified in experiment groups 1, 2, 3, 4 and KSM and American standards methods (ASM), and the relationships between the absorbance of indophenol and concentration of ammonia were compared. The amount of phenol can be reduced to 10 g (current 25 g in KSM) and NaOH can be reduced to 1.76 g (current 11 g in KSM) for the preparation of 200 mL phenate solution, and the absorbance sensitivity increased. The concentration of the phenol and NaOH correlatively affect the pH of the solution, which is a critical variable in achieving the maximum sensitivity and rapid and stable color development.

A Preliminary Study on the In-line Concentration Measurement of Absorbent Solution (흡수용액의 In-line 농도측정을 위한 기초연구)

  • 민병혁;황덕용;정시영;구기갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.152-158
    • /
    • 2003
  • Titration method is one of the widely used methods for the concentration measurement of absorbent ammonia/water. However, this method is inconvenient because the solution should be extracted for the measurement. Moreover, significant error can be introduced by the evaporation of ammonia during the sampling and measuring procedure. In this study a reliable in-line concentration measurement method was proposed. To prove the validity of the concept, a measuring apparatus was designed, built, and tested with water. It is found that the location of flow inlet and exit is important in the measurement accuracy. The flow inlet and exit located in the middle of the test cell showed the best result. By the error analysis, it is expected that the ammonia concentration can be measured within the error of $\pm$0.18% assuming the error of 0.1 K in temperature measurement and 0.1 g in weight measurement.