• Title/Summary/Keyword: Ambient monitoring

Search Result 393, Processing Time 0.024 seconds

Multi-variate Empirical Mode Decomposition (MEMD) for ambient modal identification of RC road bridge

  • Mahato, Swarup;Hazra, Budhaditya;Chakraborty, Arunasis
    • Structural Monitoring and Maintenance
    • /
    • v.7 no.4
    • /
    • pp.283-294
    • /
    • 2020
  • In this paper, an adaptive MEMD based modal identification technique for linear time-invariant systems is proposed employing multiple vibration measurements. Traditional empirical mode decomposition (EMD) suffers from mode-mixing during sifting operations to identify intrinsic mode functions (IMF). MEMD performs better in this context as it considers multi-channel data and projects them into a n-dimensional hypercube to evaluate the IMFs. Using this technique, modal parameters of the structural system are identified. It is observed that MEMD has superior performance compared to its traditional counterpart. However, it still suffers from mild mode-mixing in higher modes where the energy contents are low. To avoid this problem, an adaptive filtering scheme is proposed to decompose the interfering modes. The Proposed modified scheme is then applied to vibrations of a reinforced concrete road bridge. Results presented in this study show that the proposed MEMD based approach coupled with the filtering technique can effectively identify the parameters of the dominant modes present in the structural response with a significant level of accuracy.

The impact of outdoor environment on residential noise level satisfaction: GIS-based Analysis

  • Choi, Ga-Yoon;Jung, Hye-Jin;Lee, Jae Seung
    • Journal of KIBIM
    • /
    • v.11 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • Urban residents in crowded complexes are making increasing civil complaints about noise and demanding pleasant and comfortable residential environments. Because noise is one of the most important factors related to urban residents' dissatisfaction with their living environments, the present study investigates the direct and indirect effects of noise-related outdoor environmental factors on residential level satisfaction, using noise level data from 29 noise-measuring stations in Seoul. From 62 multi-family apartment complexes near these stations, the authors collected GIS-based environmental attribute data, as well as survey data including the residents' personal characteristics and indicators designed to measure latent psychological characteristics: noise sensitivity and residential noise level satisfaction. This study then utilized structural equation models to analyze the direct variables influencing the latent variables of noise sensitivity and residential noise level satisfaction, as well as the complex relationships among all variables. The result showed that residents who are exposed to less noise, possibly due to living in apartments facing relatively quiet roads, protected by soundproof walls, or surrounded by densely planted trees, tend to be less noise sensitive, which makes them more satisfied with the ambient noise level. Therefore, critical outdoor environmental variables can be used to reduce noise sensitivity and improve residential noise level satisfaction.

Microfiber-based Textile Pressure Sensor with High Sensitivity and Skin-breathability (높은 민감도 및 우수한 피부 통기성을 가진 마이크로 섬유 기반의 직물형 유연 압력 센서)

  • Kangto Han;Jang-hee Choi;Jeongwoo Lim;Hyeyoung Gong;Geun Yeol Bae
    • Textile Coloration and Finishing
    • /
    • v.35 no.3
    • /
    • pp.179-187
    • /
    • 2023
  • In this study, we developed a microfiber-based flexible pressure sensor with high sensitivity and excellent skin breathability. A nonwoven fabric composed of microfibers was prepared by electrospinning, which resulted in excellent moisture permeability of the sensor (143 g∙m-2∙h-1). In particular, high-pressure sensitivity (0.36 kPa-1) was achieved by introducing submicron structures on the microfiber surface by controlling the ambient humidity during electrospinning. The fabrication technology of the microfiber-based flexible pressure sensors reported in this study is expected to contribute to the commercialization of flexible pressure sensors applicable to long-term wearable health monitoring as well as virtual/augmented reality and electronic skin applications.

High Time-resolution Characterization of PM2.5 Sulfate Measured in a Japanese Urban Site

  • Ma, Chang-Jin;Kang, Gong-Unn;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.280-287
    • /
    • 2015
  • The high time-resolution monitoring data are essential to estimate rapid changes in chemical compositions, concentrations, formation mechanisms, and likely sources of atmospheric particulate matter (PM). In this study, $PM_{2.5}$ sulfate, $PM_{2.5}$, $PM_{10}$, and the number concentration of size-resolved PMs were monitored in Fukuoka, Japan by good time-resolved methods during the springtime. The highest monthly average $PM_{2.5}$ sulfate was found in May ($8.85{\mu}g\;m^{-3}$), followed by April ($8.36{\mu}g\;m^{-3}$), March ($8.13{\mu}g\;m^{-3}$), and June ($7.22{\mu}g\;m^{-3}$). The cases exceed the Japanese central government's safety standard for $PM_{2.5}$ ($35{\mu}g\;m^{-3}$) reached 10.11% during four months campaign. The fraction of $PM_{2.5}$ sulfate to $PM_{2.5}$ varied from 12.05% to 68.11% with average value of 35.49% throughout the entire period of monitoring. This high proportion of sulfate in $PM_{2.5}$ is an obvious characteristic of the ambient $PM_{2.5}$ in Fukuoka during the springtime. However, the average fraction of $PM_{2.5}$ sulfate to $PM_{2.5}$ in three rain events occurred during our intensive campaign fell right down to 15.53%. Unusually high $PM_{2.5}$ sulfate (> $30{\mu}g\;m^{-3}$) marked on three days were probably affected by the air parcels coming from the Chinese continent, the natural sulfur in the remote marine atmosphere, and a large number of ships sailing on the nearby sea. The theoretical number concentration of $(NH_4)_2SO_4$ in $PM_{0.5-0.3}$ was originally calculated and then compared to $PM_{2.5}$ sulfate. A close resemblance between the diurnal variations of the theoretically calculated number concentration of $(NH_4)_2SO_4$ in $PM_{0.5-0.3}$ and $PM_{2.5}$ sulfate concentration indicates that the secondary formed $(NH_4)_2SO_4$ was the primary form of sulfate in $PM_{2.5}$ during our monitoring period.

Optical Fiber-Based Hybrid Nerve Measurement System for Static and Dynamic Behavior of Structures (구조물의 정적 및 동적 거동 모니터링을 위한 광섬유 기반 하이브리드 신경망 계측 시스템)

  • Park, Young-Soo;Song, Kwang-Yong;Jin, Seung-Seop;Park, Young-Hwan;Kim, Sung-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.33-40
    • /
    • 2020
  • Various studies have been conducted on the structural health monitoring using optical fiber. Optical fibers can be used to measure multiple and distributed strain. Among the optical fiber sensors, FBG sensor has advantages of dynamic response measurement and high precision, but the number of measurement points is limited. Distributed fiber sensors, represented by distributed Brillouin sensors, usually have more than 1000 measurement points, but the low sampling rate makes dynamic measurements impossible. In this study, a hybrid nerve sensor system using only the advantages of the FBG sensor and the distributed Brillouin sensor has been proposed. Laboratory experiments were performed to verify the proposed system, and the accuracy and reproducibility were verified by comparing with commercial sensors. Applying the proposed system, dynamic response ambient measurements are used to evaluate the global state of the structure. When an abnormal condition is detected, the local condition of the structure is evaluated by static response measurement using the distributed measurement system. The proposed system can be used for efficient structural health monitoring.

Chemical Characteristics and Source Apportionment ofPM2.5 in Seoul Metropolitan Area in 2010 (2010년도 서울시 대기 중 PM2.5의 성분특성 및 발생원 추정에 관한 연구)

  • Moon, Kwang-Joo;Park, Seung-Myung;Park, Jong-Sung;Song, In-Ho;Jang, Sung-Ki;Kim, Jong-Chun;Lee, Seok-Jo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.711-722
    • /
    • 2011
  • This study is aimed to estimate the $PM_{2.5}$ source apportionment at Seoul intensive monitoring site located in Seoul metropolitan area. Time-resolved chemical compositions of $PM_{2.5}$ are measured in real time using ambient ion monitor, semi-continuous carbon monitor, and on-line XRF at Seoul intensive monitoring site in 2010. The mass concentration of $PM_{2.5}$ was simultaneously monitored with eight ionic species (${SO_4}^{2-}$, $NO_3{^-}$, $Cl^-$, $NH_4{^+}$, $Na^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$), two carbonaceous species (OC and EC), and fourteen elements (Si, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Zn, As, Se, Pb) in 1-hr interval. The data sets were then analyzed using EPA PMF version 3 to identify sources and contributions to $PM_{2.5}$ mass. EPA PMF modeling identified eight PM2.5 sources, including soil dust, secondary sulfate, secondary nitrate, motor vehicle, coal combustion, oil combustion, biomass burning, and municipal incineration. This study found that the average $PM_{2.5}$ mass was apportioned to anthropogenic sources such as motor vehicle, fuel combustion, and biomass burning (61%) and secondary aerosols, including sulfate and nitrate (38%).

Accuracy Evaluation of Bi-medium Deep Body Thermometer Based on Finite Element Simulation (유한 요소 시뮬레이션을 이용한 이중 매질 심부 체온계의 정확도 평가)

  • Sim, S.Y.;Ryou, H.S.;Kim, H.B.;Jeong, J.H.;Lee, S.J.;Kim, S.M.;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.160-168
    • /
    • 2014
  • Continuous body temperature monitoring is useful and essential in diverse medical procedures such as infection onset detection, therapeutic hypothermia, circadian rhythm monitoring, sleep disorder assessment, and gynecological research. However, the existing thermometers are too invasive or intrusive to be applied to long-term body temperature monitoring. In our previous study, we invented the bi-medium deep body thermometer which can noninvasively and continuously monitor deep tissue temperature. And the ratio of thermal resistances expressed as K-value should be obtained to estimate body temperature with the thermometer and it can be different under various measurement environments. Although the device was proven to be useful through preliminary simulation test and small group of human study, the experimental environment was restrictive in our previous approach. In this study, a finite element simulation was executed to obtain the K-value and evaluate the accuracy of bi-medium thermometer under various measurement environments. In addition, K-value estimation equation was developed by analyzing the influence of 5 measurement environmental factors (medium length, medium height, tissue depth, blood perfusion rate, and ambient temperature) on K-value. The results revealed that the estimation accuracy of bi-medium deep body thermometer based on computer simulation was very high (RMSE < $0.003^{\circ}C$) in various measurement environments. Also, bi-medium deep body thermometer based on K-value estimation equation showed relatively accurate results (RMSE < $0.3^{\circ}C$) except for one case. Although the K-value estimation technology should be improved for more accurate body temperature estimation, the results of finite element simulation showed that bi-medium deep body thermometer could accurately measure various tissue temperatures under diverse environments.

Air Quality Monitoring in Residential Areas near Ports and Industrial Complexes in Busan (부산시 항만 및 산단 인근 주거지역 대기질 모니터링과 분기별 특성확인)

  • Hyunji Ju;Seungho Lee;Minjung Kim;Gabeen Lee;Young-Seoub Hong
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.3
    • /
    • pp.181-190
    • /
    • 2024
  • Background: Air pollutants have been reported to have harmful effects on human health. Busan is a vulnerable area in terms of air quality due to the installation of various industrial complexes, particularly the port industry. However there is limited research data on the ambient air quality of residential areas near ports and industrial complexes. Objectives: This study aimed to determine the quarterly levels of air pollutants near industrial complexes and ports and to identify trends and characteristics of air pollutant exceedances. Methods: Air measurements were conducted quarterly. The measured air pollutants included O3, SO2, CO, NO2, PM10, and PM2.5. PM10 and PM2.5 were measured using BAM-1020 equipment, while O3, SO2, CO, and NO2 were measured using AP-370 Series equipment. The quarterly concentration levels of air pollutants were determined, and the influence of precipitation and commuting hours on fine particulate matter was examined. Analysis of variance (ANOVA) was conducted to determine if there was significance between the concentrations of fine particulate matter during commuting hours and non-commuting hours. Results: The concentrations of air pollutants were generally higher in the first and second quarters. Furthermore, the concentrations of PM10 and PM2.5 tended to decrease continuously following consecutive rainfall, with concentrations at the end of rainfall periods lower than those observed at the beginning. The frequency of exceeding average concentrations of PM10 and PM2.5 was higher on weekdays. Moreover, the average concentrations of PM10 and PM2.5 during weekday commuting hours were higher compared to non-commuting hours. Conclusions: The concentrations of air pollutants in the survey area were found to be higher than the overall average in Busan. Based on this study, continuous air quality monitoring is necessary for residential areas near industrial complexes and ports. For further research, health biomonitoring of residents in these areas should be conducted to assess their exposure levels.

Concentration and Gas-particle Partition of PCDDs/Fs and dl-PCBs in the Ambient Air of Ansan Area (안산지역 대기 중 다이옥신 및 dl-PCBs의 오염특성 조사)

  • Heo, Jong-Won;Kim, Dong-Gi;Song, Il-Seok;Lee, Gang-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.517-532
    • /
    • 2010
  • After establishment of Banwol industrial complex in 1987, Ansan city becomes the largest industrial sector development in Gyeonggi-do, Korea. As the population and industrial activity grow over this region, toxic air pollutants, particularly POPs (Persistent Organic Pollutants) from various emission sources have been major public concerns. Air samples for POPs monitoring were collected at the industrial sites ($A_2$), residential sites ($B_1$, $B_2$), commercial site (C), and rural/remote site (D) of the area of Ansan during 2008 with a prolonged industrial sampling site $A_1$ from 2001 to 2008. All samples were analysed for 2,3,7,8 substituted-polychlorinated dibenzo-p-dioxin and dibenzofurans (PCDD/Fs) and dioxin like polychlorinatd diphenyls (dl-PCBs). In site $A_1$, a steady decline of their concentrations from 2003 to 2008 was observed due to the reinforced emission guideline from waste incinerators. The average concentration of the PCDD/Fs and dl-PCBs ranged between 0.118 pg-TEQ/$m^3$ (rural/remote site D) and 0.532 pg-TEQ/$m^3$ (industrial area $A_2$). These level were generally consistent with previous studies in Gyeonggi-do, while higher than other places. Most of PCDD/Fs congener were partitioned into particle phase, whereas dl-PCBs were partitioned into gas phase. The logarithm of gas-particle partition coefficient $K_P$ of dl-PCBs and PCDD/Fs were well correlated with sub-cooled liquid vapor pressure $P_L$. The slope $m_T$ of log $K_P$ versus log $P_L$ for PCDD/Fs (-1.22) and dl-PCBs (-1.02) in industrial area ($A_2$) were high compared to other residential/commercial area. It suggests that this area was likely influenced by the direct emission source of PCDD/Fs and dl-PCBs. To simulate the partition of PCDD/Fs and dl-PCBs between gas and particle phase, Junge-Pankow model ($P_L$-base) and $K_{oa}$ model were applied. It was found that J-P model was more suitable than the $K_{oa}$ model in this study.

Quantification and Resolution of Dioxins on Capillary Columns (캐필러리 컬럼 종류에 따른 다이옥신 이성체 분리능과 정량 특성 변화)

  • Kim, Jong-Guk;Park, Jin-Soo;Kim, Kyoung-Sim;Lee, Geun-Hee;Kim, Shin-Jo
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.43-53
    • /
    • 2002
  • The analysis of polychlorodibenzo-p-dioxins (PCDDs) and polychlorodibenzo furans(PCDFs) was performed by using four different gas chromatographic columns (SP-2331, DB-5, DB-17 and DB-DIOXIN). The data reported is pertaining to flue gas, fly ash, ambient air, soil and fish. The difference in quantification of samples according to four columns was observed, it was noted that major difference was observed in the flue gas when compared with soil, fly ash, ambient air and fish. The quantification of the same samples according to four columns it was also found that DB-5 column have the highest concentration whereas SP-2331 column showed the lowest concentration. The quantification of DB-17 column for 1,2,3,6,7,8-HxCDF was found to be twice and three times higher when compared with other columns, whereas the quantification of DB-DIOXIN column for 1,2,3,7,8-PeCDD was also found to be over estimated twice when compared with other columns.