• Title/Summary/Keyword: Ambient Gas Temperature

Search Result 383, Processing Time 0.035 seconds

W 도핑된 ZnO 박막을 이용한 저항 변화 메모리 특성 연구

  • Park, So-Yeon;Song, Min-Yeong;Hong, Seok-Man;Kim, Hui-Dong;An, Ho-Myeong;Kim, Tae-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.410-410
    • /
    • 2013
  • Next-generation nonvolatile memory (NVM) has attracted increasing attention about emerging NVMs such as ferroelectric random access memory, phase-change random access memory, magnetic random access memory and resistance random access memory (RRAM). Previous studies have demonstrated that RRAM is promising because of its excellent properties, including simple structure, high speed and high density integration. Many research groups have reported a lot of metal oxides as resistive materials like TiO2, NiO, SrTiO3 and ZnO [1]. Among them, the ZnO-based film is one of the most promising materials for RRAM because of its good switching characteristics, reliability and high transparency [2]. However, in many studies about ZnO-based RRAMs, there was a problem to get lower current level for reducing the operating power dissipation and improving the device reliability such an endurance and an retention time of memory devices. Thus in this paper, we investigated that highly reproducible bipolar resistive switching characteristics of W doped ZnO RRAM device and it showed low resistive switching current level and large ON/OFF ratio. This may be caused by the interdiffusion of the W atoms in the ZnO film, whch serves as dopants, and leakage current would rise resulting in the lowering of current level [3]. In this work, a ZnO film and W doped ZnO film were fabricated on a Si substrate using RF magnetron sputtering from ZnO and W targets at room temperature with Ar gas ambient, and compared their current levels. Compared with the conventional ZnO-based RRAM, the W doped ZnO ReRAM device shows the reduction of reset current from ~$10^{-6}$ A to ~$10^{-9}$ A and large ON/OFF ratio of ~$10^3$ along with self-rectifying characteristic as shown in Fig. 1. In addition, we observed good endurance of $10^3$ times and retention time of $10^4$ s in the W doped ZnO ReRAM device. With this advantageous characteristics, W doped ZnO thin film device is a promising candidates for CMOS compatible and high-density RRAM devices.

  • PDF

The study for VOCs analysis in long path by open path FT-IR spectrometer (Open path FT-IR spectrometer를 사용한 원거리의 VOCs 측정에 관한 연구)

  • Cho, Nam Wook;Cho, Won Bo;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.108-113
    • /
    • 2014
  • The harmful materials as volatile organic compounds (VOCS) that is easy for gas to be changed from liquid on ambient temperature, those should be controlled by Korea Chemicals Management Association. The VOCs samples should be collected directly in place so that those could be analyzed. Generally but it couldn't avoid to have the risk of analyst. Moreover, if there is the place limited to entrance, it is impossible to collect directly and measure. Owing to such problem, it tried to be solved by open path FT-IR spectrometer that could be studied on the combustion gases within long path and VOCs samples were tried to measure to large volume by remote and real time. Firstly, it was to investigate optimized measured length between the system and benzene sample of VOCs. As result, The optimized measured length was confirmed with 15 meter length and the qualitative analysis could be measured on seven VOC samples. The calibration curve as quantitative analysis of benzene samples could be worked. On the basis of the result, the system as remote monitor could show to have potentiality.

Distribution of Persistent Organic Pollutants (POPs) in Different Sizes of Particles in the Ambient Air of the Pyeongteak Area (평택지역 대기 중 먼지 입경별 잔류성유기오염물질 분포특성 연구)

  • Kim, Dong-Gi;Woo, Jung-Sik;Kim, Yong-Jun;Jung, Hye-Eun;Park, Ju-Eun;Cho, Duck-Hee;Moon, Hee-Chun;Oh, Jo-Gyo
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.2
    • /
    • pp.192-203
    • /
    • 2020
  • Objectives: The concentration distributions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), dioxin-like polychlorinated biphenlys (dl-PCBs), and polycyclic aromatic hydrocarbons (PAHs) in fine particles were investigated to provide basic data on POP behavior and composition analysis. Methods: The concentrations of PCDD/Fs, dl-PCBs, and PAHs by particle size were evaluated for TSP, PM10, and PM2.5. Also, fine dust component analysis and factor analysis were performed to identify the source of PCDD/Fs. Results: The particle size distribution was found to account for 24.3% of >10 ㎛, 14.5% of 2.5-10 ㎛, and 61.2% of <2.5 ㎛. The average contributions of coarse particles (>2.5 ㎛) and fine particles (<2.5 ㎛) were PCDD/Fs 67%, dl-PCBs 66%, benzo (a) pyrene 83% and PAHs 84%, and the contributions of fine particles (<2.5 ㎛) were higher than coarse particles (>2.5 ㎛). However, the contributions of coarse particles increased in April to September with higher temperatures, while those of fine particles increased in February to March with lower temperatures. Conclusions: Low chlorinated (4Cl-5Cl) PCDD/Fs were more adsorbed compared to coarse particles due to the influence of pollutant migration from particulate to gas phase according to temperature rise, whereas high chlorinated (6Cl-8Cl) PCDD/Fs were more adsorbed compared to fine particles. PCDD/Fs sources were assessed to be major sources of emissions, such as incineration facilities and/or open burning.

Hydrogen Isotope Exchange Reaction in Electrical Discharge through D2/H2O System (전기방전하에서 D2/H2O 반응계의 수소 동위원소 교환반응)

  • Kim, H.J.;Park, Y.D.;Lee, W.M.
    • Journal of Hydrogen and New Energy
    • /
    • v.9 no.2
    • /
    • pp.77-84
    • /
    • 1998
  • Hydrogen isotope exchange in mixtures of $H_2O/D_2$, $H_2O/D_2O$, or $D_2O/H_2$ can be facilitated under electrical discharge. For example, a simple DC corona discharge through the mixture creates a plasma in which the reactants are excited energetically. The reactants in such plasma, due to increase in population of excited quantum levels or due to production of radicals or ions, undergo very rapid chemical reactions even at ambient temperature. The isotope exchange reaction of hydrogen(H) and deuterium(D) produces the third kind of heavy water(HDO) and isotopic hydrogen gas(HD), as shown in $D_2+H_2O{\rightarrow}HD$ K=11.257(at $25^{\circ}C$) The reaction products can be detected with temporal resolution using the Fourier transform infrared(FTIR) absorption spectroscopy. Since $H_2O$, $D_2O$ and HDO are all infrared active with different absorption peaks, FTIR proves to be a useful tool for monitoring the reaction. Experimental results show that the electrical method is indeed a useful means to promote the reaction, showing a better efficiency than traditional catalytic methods.

  • PDF

Determination of Volatile Organic Compounds emitted from Municipal Solid Waste Landfill Site by Thermal Desorption-Cryofocusing-GC/FID/FPD (열탈착-저온농축-GC/FID/FPD에 의한 도시 생활폐기물 매립장에서 방출되는 휘발성 유기화합물의 측정에 관한 연구)

  • Kim, Man-Goo;Jung, Young-Rim;Seo, Young-Min;Nam, Sung-Hyun;Kwon, Young-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.274-285
    • /
    • 2001
  • In this study, the thermal desorption-cryofocusing-gas chromatographic(TD-C-GC) method was developed for determination of volatile organic compounds(VOCs) in ambient air and was applied at the municipal solid waste landfill sites. On-column cryofocusing was possible only with a 100 ml dewars bottle in TD-C-GC method with a stainless steel column. However, high operating pressure was needed for purging VOCs from the absorbent trap, which was able to solve by pressure programming with a electric pressure controller. By using both pressure and temperature programming brought increasing of resolution power in on-column cryofocusing method, but the high pressure caused a leakage of sample tube with repeated use. A loop cryofocusing devise was also developed and compared with the direct on-column method. In loop cryofocusing method, VOCs were concentrated on a 0.8mm i.d. loop which is located between the injector and separation column by using liquid nitrogen. In order to purge VOCs from the absorbent trap, only 0.4 psi of pressure was need in the loop cryofocusing method. Dual detection system was applied for the analysis of VOCs; a FID was used for hydrocarbons and a FPD was used for sulfur-containing compounds. Qualitative analysis was done by on-column cryofocusing GC-MS system. Among the large number of VOCs, toluene was the most abundant. Hydrogen sulfide, dimethyl sulfide, carbon disulfide, dimethyl disulfide and methyl propyl disulfide were detected at landfill site by FPD.

  • PDF

Extending shelf-life of Oriental Melon(Cucumis melo L.) by Modified Atmosphere Packaging (MA 포장기법에 의한 참외의 신선도 유지)

  • Park, Jong-Dae;Hong, Seok-In;Park, Hyung-Woo;Kim, Dong-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.481-490
    • /
    • 2000
  • Modified atmosphere packaging was applied to oriental melon(Cucumis melo L. var. makuwa Mak.) to extend its freshness during distribution. Gas composition and ethylene content in the film bags changed rapidly at the early stage of storage. Within 10 days, weight loss of the unpackaged increased upto 7.68% while those of the packaged remained less than 1.0% except LDPE film modified by addition of 5%(w/w) zeolite with $20\;{\mu}m$ thickness(20CK, 2.38%). Firmness was effectively maintained in the LDPE film modified by addition of 5%(w/w) zeolite with $40\;{\mu}m$ thickness(40CK) and the LDPE film with $40\;{\mu}m$ thickness containing ethylene absorber sachet(40LP). Peel color of the fruit changed rapidly in control and a little in 40CK. Oriental melon packages using 40CK provided better visual and sensory quality retention compared with others. Results suggested that packaging treatment such as 40CK could be used for extending freshness of oriental melon during transport period at ambient temperature.

  • PDF

Physicochemical properties of rice-distilled spirit matured in oak and stainless steel containers (숙성용기를 달리한 전통 쌀 증류식 소주의 숙성 중 이화학 특성 및 향기성분의 변화)

  • Kang, Sun-Hee;Kim, Jae-Ho;Lee, Ae-Ran;Kim, A-Ra;Kim, Tae-Wan
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.4
    • /
    • pp.369-376
    • /
    • 2017
  • Maturation of distilled spirit can generate diverse flavors and tastes. Rice Soju was matured in oak casks (MSO) and stainless steel containers (MSS) for one year at ambient temperature. Ipguk (Aspergillus luchuensis) and Saccharomyces cerevisiae Y88-4 were used, and reduced pressure ($110{\pm}20Torr$) distillation was applied to brew Soju. Acidity and conductivity were increased in both MSO and MSS. MSO reduced alcohol content (from 43 to 40%) and volume (from 18,000 to 12,730 mL), and significantly altered yellowness (from 0.2 to 30.2). Furthermore, MSO increased the isoamyl alcohol (from 276.7 to $339.2{\mu}g/mL$) and isobutyl alcohol (from 122.3 to $144.2{\mu}g/mL$) content. Gas chromatography-mass spectrometry was used to detect volatile compounds in Soju, which included 20 esters, 7 alcohols, 2 acids, and 5 miscellaneous compounds. Oak lactone was detected only in MSO and was considered as a specific flavor component associated with oak maturation. Thus, maturation materials contribute to the physicochemical property of distilled spirits.

Source Identification and Trends in Atmospheric Particulate-bound Mercury at Seoul and Baengnyeong, South Korea (서울과 백령도의 대기 중 입자상 수은의 분포 특성 및 발생원 추정연구)

  • Noh, Seam;Park, Kwang-Su;Kim, Hyuk;Yu, Seok-Min;Lim, Yong-Jae;Lee, Min-Do;Seok, Kwang-Seol;Kim, Younghee
    • Journal of Environmental Analysis, Health and Toxicology
    • /
    • v.21 no.4
    • /
    • pp.220-228
    • /
    • 2018
  • $PM_{2.5}$-bound mercury (PBM) was monitored at weekly intervals for three years (from 2014 to 2016) at an urban (Seoul) and rural site (Baengnyeong) in South Korea. The average PBM concentrations in $PM_{2.5}$ samples over the entire sampling period were $12{\pm}11pg/m^3$ and $36{\pm}34pg/m^3$ for Baengnyeong and Seoul, respectively. Seasonal differences were pronounced, with concentrations being highest in winter due to local meteorological conditions (high gas-particle coefficient due to low temperature and low mixing layer height in winter) as well as seasonal factors, such as coal combustion for heating purposes in China. In Baengnyeong, the significant positive correlation of PBM with $PM_{2.5}$, air pollutants, and heavy metals suggested that coal combustion in China might be the most important source of ambient mercury in Korea. In winter, no correlation of PBM with $PM_{2.5}$, air pollutants, and heavy metals was seen in Seoul. Furthermore, Seoul showed higher $PBM/PM_{2.5}$ and $Pb/PM_{2.5}$ ratios in winter due to the strong atmospheric oxidation-reduction reaction conditions as well as local and regional PBM sources. We conclude that immediate attention must be given to addressing PBM levels in Korea, including considering it as a key component of future air quality monitoring activities and mitigation measures.

Influence of dietary organic trace minerals on enteric methane emissions and rumen microbiota of heat-stressed dairy steers

  • A-Rang Son;Mahfuzul Islam;Seon-Ho Kim;Sung-Sill Lee;Sang-Suk Lee
    • Journal of Animal Science and Technology
    • /
    • v.65 no.1
    • /
    • pp.132-148
    • /
    • 2023
  • Ruminants are the main contributors to methane (CH4), a greenhouse gas emitted by livestock, which leads to global warming. In addition, animals experience heat stress (HS) when exposed to high ambient temperatures. Organic trace minerals are commonly used to prevent the adverse effects of HS in ruminants; however, little is known about the role of these minerals in reducing enteric methane emissions. Hence, this study aimed to investigate the influence of dietary organic trace minerals on rumen fermentation characteristics, enteric methane emissions, and the composition of rumen bacteria and methanogens in heat-stressed dairy steers. Holstein (n=3) and Jersey (n=3) steers were kept separately within a 3×3 Latin square design, and the animals were exposed to HS conditions (Temperature-Humidity Index [THI], 82.79 ± 1.10). For each experiment, the treatments included a Control (Con) consisting of only basal total mixed rations (TMR), National Research Council (NRC) recommended mineral supplementation group (NM; TMR + [Se 0.1 ppm + Zn 30 ppm + Cu 10 ppm]/kg dry matter), and higher concentration of mineral supplementation group (HM; basal TMR + [Se 3.5 ppm + Zn 350 ppm + Cu 28 ppm]/kg dry matter). Higher concentrations of trace mineral supplementation had no influence on methane emissions and rumen bacterial and methanogen communities regardless of breed (p > 0.05). Holstein steers had higher ruminal pH and lower total volatile fatty acid (VFA) concentrations than Jersey steers (p < 0.05). Methane production (g/d) and yield (g/kg dry matter intake) were higher in Jersey steers than in Holstein steers (p < 0.05). The relative abundances of Methanosarcina and Methanobrevibacter olleyae were significantly higher in Holstein steers than in Jersey steers (p < 0.05). Overall, dietary organic trace minerals have no influence on enteric methane emissions in heat-stressed dairy steers; however, breed can influence it through selective alteration of the rumen methanogen community.

Long-term Climate Change Research Facility for Trees: CO2-Enriched Open Top Chamber System (수목의 장기 기후변화 연구시설: CO2 폭로용 상부 개방형 온실)

  • Lee, Jae-Cheon;Kim, Du-Hyun;Kim, Gil-Nam;Kim, Pan-Gi;Han, Sim-Hee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.1
    • /
    • pp.19-27
    • /
    • 2012
  • The open-top chamber (OTC) system is designed for long term studies on the climate change impact on the major tree species and their community in Korea. In Korea Forest Research Institute (KFRI), the modified OTC system has been operating since September 2009. The OTC facility consists of six decagon chambers (10 meters in diameter by 7 meters high) with controlled gas concentration. In each chamber, a series of vertical vent pipes are installed to disperse carbon dioxide or normal air into the center of the chamber. The OTC is equipped with remote controlled computer system in order to maintain a stable and elevated concentration of carbon dioxide in the chamber throughout the experimental period. The experiment consisted of 4 treatments: two elevated $CO_2$ levels ($1.4{\times}$ and $1.8{\times}$ ambient $CO_2$) and two controls (inside and outdoors of the OTC). Average operational rate was the lowest (94.2%) in June 2010 but increased to 98% in July 2010 and was 100% during January to December 2011. In 2010~2011, $CO_2$ concentrations inside the OTCs reached the target programmed values, and have been maintained stable in 2011. In 2011, $CO_2$ concentrations of 106%, 100% and 94% of target values has been recorded in control OTC, $1.4{\times}$ $CO_2$-enriched OTC and $1.8{\times}$ $CO_2$-enriched OTC, respectively. With all OTC chambers, the difference between outside and inside temperatures was the highest ($1.2{\sim}2.0^{\circ}C$) at 10 am to 2 pm. Temperature difference between six OTC chambers was not detected. The relative humidity inside and outside the chambers was the same, with minor variations (0~1%). The system required the highest amount of $CO_2$ for operation in June, and consumed 11.33 and 17.04 ton in June 2010 and 2011, respectively.