• 제목/요약/키워드: Aluminum Oxide

검색결과 901건 처리시간 0.028초

In vitro shear bond strength between fluorinated zirconia ceramic and resin cements

  • Tanis, Merve Cakirbay;Akay, Canan;Akcaboy, Turgut Cihan;Sen, Murat;Kavakli, Pinar Akkas;Sapmaz, Kadriye
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.205-210
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the efficiency of a gas-phase fluorination method under different fluorination periods through using two resin cements. MATERIALS AND METHODS. 84 zirconia specimens in dimensions of $5mm{\times}5mm{\times}2mm$ were prepared and surface treated with $50{\mu}m$ aluminum oxide particles or gas phase fluorination for 2 min, 5 min, or 10 min. One specimen in each group was surface analyzed under scanning electron microscope. The remaining specimens were bonded to composite cylinders in dimensions of 2 mm diameter and 3 mm high with Panavia SA Plus or Variolink N. Then, the specimens were stored in $37^{\circ}C$ distilled water for 24 hours and shear bond strength test was applied at a speed of 1 mm/min. RESULTS. The highest shear bond strength values were observed in the samples fluorinated for 5 minutes and cemented with Panavia SA Plus. Variolink N did not elicit any statistical differences between surface treatments. Panavia SA Plus resin cement and Variolink N resin cements featured statistically significant difference in shear bond strength values only in the case of 5 minutes of fluorination treatment. CONCLUSION. According to the results of this study, application of 5 minutes of fluorination with 10-methacryloyloxydecyl dihydrogen phosphate monomer (MDP) containing Panavia SA Plus resin cement increased the resin bond strength of zirconia. Fluorination of the zirconia surface using conventional resin cement, Variolink N, did not lead to an increase in bond strength.

Electrochemical Synthesis of Dumbbell-like Au-Ni-Au Nanorods and Their Surface Plasmon Resonance

  • Park, Yeon Ju;Liu, Lichun;Yoo, Sang-Hoon;Park, Sungho
    • Journal of Electrochemical Science and Technology
    • /
    • 제3권2호
    • /
    • pp.57-62
    • /
    • 2012
  • In this report, we demonstrate that the longitudinal localized surface plasmon resonance mode can be suppressed when the nanorods were in dumbbell shape. The seed nanorods were synthesized by electrochemical deposition of metals into the pores of anodic aluminum oxide templates. The dumbbell-like nanorods were grown from seed Au-Ni-Au nanorods by a rate-controlled seed-mediated growth strategy. The selective deposition of Au atoms onto Au blocks of Au-Ni-Au nanorods produced larger diameter of Au nanorods with bumpy surface resulting in dumbbell-like nanorods. The morphology of nanorods depended on the reduction rate of $AuCl_4^-$, slow rate producing smooth surface of Au nanorods, but high reduction rate producing bumpy surface morphology. Through systematic investigation into the UV-Vis-NIR spectroscopy, we found that the multiple localized surface plasmon resonance (LSPR) modes were available from single-component Au nanorods. And, their LSPR modes of Au NRs with bumpy surface, compared to the smooth seed Au NRs, were red-shifted, which was obviously attributed to the increased electron oscillation pathways. While the longitudinal LSPR modes of smoothly grown Au NRs were blue-shifted except for a dipole transverse LSPR mode, which can be interpreted by decreased aspect ratio. In addition, dumbbell-like nanorods showed an almost disappeared longitudinal LSPR mode. It reflects that the plasmonic properties can be engineered using complex nanorods structure.

Facile Synthesis of Pt Nanoparticle and Graphene Composite Materials: Comparison of Electrocatalytic Activity with Analogous CNT Composite

  • Lee, Jihye;Jang, Ho Young;Jung, Insub;Yoon, Yeoheung;Jang, Hee-Jeong;Lee, Hyoyoung;Park, Sungho
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권7호
    • /
    • pp.1973-1978
    • /
    • 2014
  • Here, we present a facile method to synthesize Pt nanoparticles (NPs) and graphene composite materials (Pt/G) via vacuum filtration. Anodic aluminum oxide (AAO) templates were used to separate Pt/G composite and liquid phase. This method can be used to easily tune the mass ratio of Pt NPs and graphene. Pt NPs, graphene, and carbon nanotubes (CNTs) as building blocks were characterized by a variety of techniques such as scanning electron microscopy, UV-Vis spectroscopy, and Raman spectroscopy. We compared the electrocatalytic activities of Pt/G with Pt NP and CNT films (Pt/CNT) by cyclic voltammetry (CV), CO oxidation, and methanol oxidation. Pt/G was much more stable than pure Pt films. Also, Pt/G had better electrochemical activity, CO tolerance and methanol oxidation than Pt/CNT loaded with the same amount of Pt NPs due to the better dispersion of Pt NPs on graphene flakes without aggregation. We further synthesized Au@Pt disk/G and Pt nanorods/G to determine if our synthetic method can be applied to other NP shapes such as nanodisks and nanorods, for further electrocatalysis studies.

전기화학적 분석을 통해 산출된 코팅 결함율이 트라이볼로지적 특성에 미치는 영향 평가 (Influence of Coating Defect Ratio on Tribological Behavior Determined by Electrochemical Techniques)

  • 이영제;김우중;안승호;김호건;김정구;조정우
    • Tribology and Lubricants
    • /
    • 제20권6호
    • /
    • pp.306-313
    • /
    • 2004
  • Many of the current development in surface modification engineering are focused on multilayered coatings, which have the potential to improve the tribological properties. Four different multilayered coatings were deposited on AISI D2 steel in this study. The prepared samples are designed as $WC-Ti_{0.6}Al_{0.4}N,\;WC-Ti_{0.53}Al_{0.47}N,\;WC-Ti_{0.5}Al_{0.5}N\;and\;WC-Ti_{0.43}Al_{0.57}N$. The multilayered coatings were investigated with respect to coating surface and cross-sectional morphology, roughness, adhesion, hardness, porosity and tribological behaviors. Especially, wear tests of four multilayered coatings were performed by using a ball-on-disc configuration with a linear sliding speed of 0.017 m/sec and a normal load of 5.38 N load. The tests were carried out at room temperature in air by employing AISI 52100 steel ball $(H_R\;=\;66) $ having a diameter of 10 mm. The surface morphology, and topography of the wear scars of samples and balls have been determined by using scanning electron spectroscopy (SEM). Also, wear mechanism was determined by using SEM coupled with energy-dispersive spectroscopy (EDS). Results have showed an improved wear resistance of the $WC-Ti_{1-x}Al_xN$coatings with increasing of Al (aluminum) concentration.

산화알루미늄 나노물질이 랫드의 대뇌와 신장에 미치는 영향 (Toxic Effects of Alumina Nanoparticles in Rat Cerebrums and Kidneys)

  • 조은혜;서균백;김현미;최경희;권정택;김필제;엄익춘
    • 한국환경보건학회지
    • /
    • 제42권1호
    • /
    • pp.27-33
    • /
    • 2016
  • Objectives: Alumina nanoparticles ($Al_2O_3$, Al-NPs) are used for various purposes, including as coating agents and paint additives. Their potential toxicity has raised concern for human health. This study focuses on exploring the toxic effects on the brain and kidneys caused by Al-NPs exposure in rats. Methods: The animals were orally administered Al-NPs at 10, 50 and 100 mg/kg body weight for 28 days following OECD TG 407. To determine the targeted toxicity of Al-NPs, histopathological examination and gene expression analysis were conducted on the rats. Results: The Al-NPs treatment induced kidney tubular dilatation. In the rat cerebrums, the expression levels of 126 genes experienced two-fold or greater increases in response to Al-NPs, including other genes encoding proteins involved in cell differentiation, transcription and signal transduction. In the rat kidneys, the expression levels of 152 genes also showed two-fold or greater increases in response to Al-NPs, including other genes encoding proteins involved in apoptosis, transcription and signal transduction. Conclusion: These results suggest that exposure to Al-NPs influences cellular signal pathways of kidney and cerebrum, and it can be a toxic indicators of nanometrials.

도재소부전장관 파절시 비귀금속과 도재수리용 레진간의 결합력에 관한 실험적 연구 (SHEAR BOND STRENGTH OF PORCELAIN REPAIR RESINS TO NONPRECIOUS CERAMO-METAL ALLOY)

  • 안준영;배정수;한동후
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.195-209
    • /
    • 1991
  • When the porcelain fused to metal restorations were fractured at the metal interface, various techniques and materials for intraoral porcelain repair have been suggested. The purpose of this study was to investigate the effect of metal surface treatment method and water storage on the shear bond strength of four porcelain repair systems. : Clearfil(Kuraray), All-bond(Bisco), Superbond C & B(Sun Medical), Panavia OP(Kuraray). After the metal surfaces of the specimens were sandblasted by aluminum oxide or roughened by diamond point, they were stored in double deionized water(24 Hr., $37^{\circ}C$) and thermocycling was performed(24 Hr., 1024 cycles), and again half of specimes were stored in water bath(2 Months, $37^{\circ}C$). Mean shear bond strength and mode of failure were recorded. The results of this study were obtained as follows : 1. Differences were observed between the sandblasted and diamond - treated specimens in Clearfil, All-bond, and Superbond. No statistically significant differences were observed in Panavia. 2. The 2-month storage time significantly affected the bond strength of All-bond and Superbond. No statistically significant differences were observed in Clearfil and Panavia. 3. The failures were observed at the interface between opaque resin and the metal in Clearfil and All-bond. 4. The failures were observed at the interface between opaque resin and veneered resin in Panavia. The failures were observed at the interface between opaque resin and veneered resin in Superbond, but 40% of them were fractured at the interface between the metal and opaque resin after 2-month storage time.

  • PDF

식각된 비 귀금속 합금과 법랑질간의 접착 인장강도에 대한 연구 (A STUDY ON THE TENSILE BOND STRENGTH OF ETCHED BASE METALS)

  • 박상원;양홍서
    • 대한치과보철학회지
    • /
    • 제25권1호
    • /
    • pp.303-316
    • /
    • 1987
  • The purpose f this study was to evaluate the effect of resin film thickness on the tensile bond strength and to compare the tensile bond strengths of 4 differently treated metal surfaces. For the experiment, seventy metal specimens were cast with Verabond and divided into I, II, III, groups. The metal specimens in group I were electrolytically etched and cemented with Panavia under finger pressure. Cement film thickness was regulated with metal spacers. The metal specimens in Group II were treated by 4 methods, such as electrolytic etching method, salt-roughened method, EZ-oxisor method , chemical etching method and cemented with Panavia. In group III, electrolytically etched metal specimens were cemented with Hy-Bond. The etched surface of metal specimens and the cement film thickness were examined under the scanning electron microscope. Results were as follows; 1. The tensile bond strength showed no significant difference between $30{\mu}m,\;80{\mu}m,\;130{\mu}m$ film thicknessspecimens. 2. There was no significant difference in the tensile bond strength between the 4 differently treated metal specimens. 3. The tensile bond strength showed significant difference between Panavia and Hy-Bond. 4. Scanning electron microscope photograph revealed that tile interdendritic eutectic was removed in electrolytically etched metal surfaces hilt even dendritic arm was removed in Chemically etched metal surfaces. 5. The metal surfaces which were air-abraded with $50{\mu}m$ aluminum oxide showed roughness and small crack on scanning electron microscope photograph.

  • PDF

Evaluation of shear bond strength of repair acrylic resin to Co-Cr alloy

  • Kulunk, Safak;Kulunk, Tolga;Sarac, Duygu;Cengiz, Seda;Baba, Seniha
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.272-277
    • /
    • 2014
  • PURPOSE. The purpose of this study was to investigate the impact of different surface treatment methods and thermal ageing on the bond strength of autopolymerizing acrylic resin to Co-Cr. MATERIALS AND METHODS. Co-Cr alloy specimens were divided into five groups according to the surface conditioning methods. C: No treatment; SP: flamed with the Silano-Pen device; K: airborne particle abrasion with $Al_2O_3$; Co: airborne particle abrasion with silica-coated $Al_2O_3$; KSP: flamed with the Silano-Pen device after the group K experimental protocol. Then, autopolymerized acrylic resin was applied to the treated specimen surfaces. All the groups were divided into two subgroups with the thermal cycle and water storage to determine the durability of the bond. The bond strength test was applied in an universal test machine and treated Co-Cr alloys were analyzed by scanning electron microscope (SEM). Two-way analysis of variance (ANOVA) was used to determine the significant differences among surface treatments and thermocycling. Their interactons were followed by a multiple comparison' test performed uing a post hoc Tukey HSD test (${\alpha}=.05$). RESULTS. Surface treatments significantly increased repair strengths of repair resin to Co-Cr alloy. The repair strengths of Group K, and Co significantly decreased after 6,000 cycles (P<.001). CONCLUSION. Thermocycling lead to a significant decrease in shear bond strength for air abrasion with silica-coated aluminum oxide particles. On the contrary, flaming with Silano-Pen did not cause a significant reduction in adhesion after thermocycling.

Effect of surface treatments and universal adhesive application on the microshear bond strength of CAD/CAM materials

  • Sismanoglu, Soner;Gurcan, Aliye Tugce;Yildirim-Bilmez, Zuhal;Turunc-Oguzman, Rana;Gumustas, Burak
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권1호
    • /
    • pp.22-32
    • /
    • 2020
  • PURPOSE. The aim of this study was to evaluate the microshear bond strength (µSBS) of four computer-aided design/computer-aided manufacturing (CAD/CAM) blocks repaired with composite resin using three different surface treatment protocols. MATERIALS AND METHODS. Four different CAD/CAM blocks were used in this study: (1) flexible hybrid ceramic (FHC), (2) resin nanoceramic (RNC), (c) polymer infiltrated ceramic network (PICN) and (4) feldspar ceramic (FC). All groups were further divided into four subgroups according to surface treatment: control, hydrofluoric acid etching (HF), air-borne particle abrasion with aluminum oxide (AlO), and tribochemical silica coating (TSC). After surface treatments, silane was applied to half of the specimens. Then, a silane-containing universal adhesive was applied, and specimens were repaired with a composite, Next, µSBS test was performed. Additional specimens were examined with a contact profilometer and scanning electron microscopy. The data were analyzed with ANOVA and Tukey tests. RESULTS. The findings revealed that silane application yielded higher µSBS values (P<.05). All surface treatments were showed a significant increase in µSBS values compared to the control (P<.05). For FHC and RNC, the most influential treatments were AlO and TSC (P<.05). CONCLUSION. Surface treatment is mandatory when the silane is not preferred, but the best bond strength values were obtained with the combination of surface treatment and silane application. HF provides improved bond strength when the ceramic content of material increases, whereas AlO and TSC gives improved bond strength when the composite content of material increases.

Anti-inflammatory and Anti-oxidative Effects of Alpiniae Oxyphyllae Fructus Hot Aqueous Extract in Lipopolysaccharide (LPS)-stimulated Macrophages

  • Jo, Na Young;Lee, Pyeong Jae;Roh, Jeong Du
    • Journal of Acupuncture Research
    • /
    • 제34권2호
    • /
    • pp.83-91
    • /
    • 2017
  • Objectives : Alpiniae oxyphyllae Fructus (AOF) is an herbal medicine, which has been used for the treatment of fatigue, chills, and poor physical conditions. The objective of this study was to investigate the anti-inflammatory and anti-oxidative effects of AOF hot aqueous extract. Methods : The cytotoxicity of AOF extract was evaluated using the MTT assay. Nitric oxide (NO) production was measured by the Griess reaction. Prostaglandin $E_2$ ($PGE_2$) production was measured by a commercial competitive enzyme immunoassay. Cytokine production (IL-1tion co6, and TNF- F- was measured by ELISA. The anti-oxidative effect of AOF extracts was measured by the DPPH method. Polyphenol and flavonoid contents were measured by Folin-Ciocalteu's phenol reagent and aluminum chloride, respectively. Results : AOF hot aqueous extract did not show toxicity at doses of 25, 50, 100, and $200{\mu}g/mL$. AOF extract significantly inhibited NO production at doses of 100 and $200{\mu}g/mL.PGE_2$ production was inhibited by AOF extract treatment at doses of 100 and $200{\mu}g/mL$. AOF extracts reduced IL-6 production in a dose-dependent manner. IL-1ent maTNF- F- 1ent mannerd IL-6 production in uction at doses of 100 and ${\mu}g/mL$. The DPPH free radical scavenging capability was above 50% at $200{\mu}g/mL$. Conclusion : This study suggests that AOF hot aqueous extract may exert anti-inflammatory and anti-oxidative effects in a dose-dependent manner. Further studies are required for validating the safety and efficacy of AOF.