• 제목/요약/키워드: Aluminium Heat Sink

검색결과 9건 처리시간 0.023초

히트싱크의 핀 배열에 따른 냉각특성에 관한 실험적 연구 (An Experimental Study on Cooling Characteristic according to Fin Array of Aluminum Heat Sink)

  • 윤성운;김재열;고가진
    • 한국기계가공학회지
    • /
    • 제17권1호
    • /
    • pp.138-143
    • /
    • 2018
  • In general, the operating temperature of electronic equipment is closely related to product life and reliability, and it is recognized that effectively cooling the parts is an important problem. In this paper, an experimental study on the cooling characteristic according to the pin array of the heat sink is conducted. The experiment on the heat sink was based on the natural convection and temperature distribution changes. The experimental results indicate that the pin array of the heat sink has an effect on the thermoelectric module's cooling characteristic.

PHP를 결합한 알루미늄 히트싱크의 냉각성능에 관한 연구 (A Study on Cooling Performance of Aluminium Heat Sink with Pulsating Heat Pipe)

  • 김종수;하수정;권용하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1016-1021
    • /
    • 2011
  • 열전소자를 이용한 냉각 장치에 있어서 열전소자발열부측의 제거 열량은 제품의 성능 및 적용범위를 결정하는 주요변수가 되므로 히트싱크의 열저항을 최소화 할 수 있는 최적 조건의 히트싱크 설계를 필요로 한다. 발열부가 작고 상대적으로 히트싱크 면적이 커서 히트싱크 전체면으로 열확산이 필요한 경우 히트싱크의 방열 성능을 향상시키기 위하여 작동유체 R-22의 진동형 히트파이프를 이용하여 열전소자의 발열부측의 발열량(30W, 60W, 80W, 100W)과 공기 유속(1~4 m/s)에 따른 히트싱크의 열저항 실험 및 수치해석 결과와 비교 분석을 통해 히트싱크의 냉각 성능을 향상 시킬 수 있는 방법을 연구하였다.

히트파이프를 사용한 조명용 LED의 냉각에 대한 연구 (A Study on the Cooling of High Power LED Component using Flat Heat Pipe)

  • 장영운;김병호;임익태
    • 반도체디스플레이기술학회지
    • /
    • 제8권4호
    • /
    • pp.25-29
    • /
    • 2009
  • In this study, a thin plate-type heat pipe, instead of a solid aluminium heat sink, is used to eliminate heat released from LED components for lighting. Effects of the heat pipe size and installation angle are studied both in numerically and experimentally. According to the results, temperature on LED chip, when a heat pipe is used, is $1.2^{\circ}C$ lower than using the conventional metal PCB. The overall temperature drop is $32^{\circ}C$ if the heat pipe is properly used. The highest cooling performance is obtained in the case when the angle of a heat pipe installation is $90^{\circ}$.

  • PDF

Experimental study on natural circulation using liquid nitrogen for superconducting applications

  • Choi, Yeon Suk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.49-52
    • /
    • 2013
  • An experiment to investigate the natural circulation of a cryogen has been performed. The study is motivated mainly by our recent development of cryogenic cooling system for prototype superconducting cyclotron without any circulating pump. In the natural circulation loop system, a cooling channel is attached on the outer surface of the aluminium block and the liquid nitrogen passes through inside of the channel to cool the block indirectly. A cryocooler as a heat sink is located at the top to re-condense cryogenic vapor coming from the aluminium block in which electrical heater is installed as a heat source. The main dimensions are determined using the relevant analysis and the natural circulation loop is successfully fabricated. The temperature distributions in the loop are measured during initial cool-down process and in steady state, from which the modified Grashof numbers are calculated and compared with the existing correlation estimated with one-dimensional analysis for steady state flow.

전력변환 반도체용 히트파이프식 냉각기의 설계와 작동특성 (Design and Operational characteristics of a Heat Pipe Heat Sink for Cooling of Power Semiconductors)

  • 강환국;김철수
    • 전력전자학회논문지
    • /
    • 제6권6호
    • /
    • pp.572-581
    • /
    • 2001
  • 최대 1800W의 열부하를 발생하는 전력반도체를 냉각하는 히트파이프 히트싱크를 설계하고 제작하였다. 히으파이프 냉각장치는 4개의 외경 22.23mm 인 FC-72 히트파이프, 알루미늄 블록 (130${\times}$160${\times}$35mm) 및 126개의 알루미늄핀 (250${\times}$58${\times}$0.8mm)으로 구성되어 있다. 성능 실험결과 총열저항은 1~2kW의 열부하일때 2~3m/s의 풍속에 풍속의 증가에 따라 0.02~0.018$^{\circ}C$/W 를 나타냈다. 이 결과는 3 m/s의 풍속에서 1800W의 열부하가 주어질 때 $40^{\circ}C$미만의 온도상승을 나타내는 것으로 설계 목표를 잘 만족하였다. 이 외로 대류 및 히트파이프의 열저항의 실험값은 몇가지 상관식에 의한 예측값과 비교적 잘 일치하였다.

  • PDF

CVD 다이아몬드가 코팅된 알루미늄 방열판의 방열 특성 (Heat Spreading Properties of CVD Diamond Coated Al Heat Sink)

  • 윤민영;임종환;강찬형
    • 한국표면공학회지
    • /
    • 제48권6호
    • /
    • pp.297-302
    • /
    • 2015
  • Nanocrystalline diamond(NCD) coated aluminium plates were prepared and applied as heat sinks for LED modules. NCD films were deposited on 1 mm thick Al plates for times of 2 - 10 h in a microwave plasma chemical vapor deposition reactor. Deposition parameters were the microwave power of 1.2 kW, the working pressure of 90 Torr, the $CH_4/Ar$ gas ratio of 2/200 sccm. In order to enhance diamond nucleation, DC bias voltage of -90 V was applied to the substrate during deposition without external heating. NCD film was identified by X-ray diffraction and Raman spectroscopy. The Al plates with about 300 nm thick NCD film were attached to LED modules and thermal analysis was carried out using Thermal Transient Tester (T3ster) in a still air box. Thermal resistance of the module with NCD/Al plate was 3.88 K/W while that with Al plate was 5.55 K/W. The smaller the thermal resistance, the better the heat emission. From structure function analysis, the differences between junction and ambient temperatures were $12.1^{\circ}C$ for NCD/Al plate and $15.5^{\circ}C$ for Al plate. The hot spot size of infrared images was larger on NCD/Al than Al plate for a given period of LED operation. In conclusion, NCD coated Al plate exhibited better thermal spreading performance than conventional Al heat sink.

온수를 이용한 열전발전기에서 유량변화에 따른 발전 특성 (Characteristic of Electric Generation for the Water Flow Rate in Thermoelctric Generator Using Hot Water)

  • 우병철;이희웅;서창민
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1333-1340
    • /
    • 2002
  • The objective of this study is to develop a thermoelectric generation system which converts unused energy from close-at-hand sources such as garbage incineration heat and industrial exhaust etc. into electricity. This paper presents applicability of a commercially available thermoelectric generator f3r waster heat recovery. The test facility consists of water heater, pump, thermoelectric module and aluminium tubes and hot and cold water is used as heat source and sink fluids. It is shown that the three components of thermoelectric research exist in manufacturing a thermoelectric generator. The first component is fabrication of thermoelectric materials, the second is manufacturing of thermoelectric generator with 32 thermoelectric modules. The last one is characteristic measuring of thermoelectric generator with 32 thermoelectric modules of two types, cooling and power purpose. It was found that the rate of cold and hot water is 25 and 37 liter per minute and the maximum power of thermoelectric generator is 28Watts and its efficiency is 1.04%.

Influence of Bath Temperature on Electroless Ni-B Film Deposition on PCB for High Power LED Packaging

  • Samuel, Tweneboah-Koduah;Jo, Yang-Rae;Yoon, Jae-Sik;Lee, Youn-Seoung;Kim, Hyung-Chul;Rha, Sa-Kyun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.323-323
    • /
    • 2013
  • High power light-emitting diodes (LEDs) are widely used in many device applications due to its ability to operate at high power and produce high luminance. However, releasing the heat accumulated in the device during operating time is a serious problem that needs to be resolved to ensure high optical efficiency. Ceramic or Aluminium base metal printed circuit boards are generally used as integral parts of communication and power devices due to its outstanding thermal dissipation capabilities as heat sink or heat spreader. We investigated the characterisation of electroless plating of Ni-B film according to plating bath temperature, ranging from $50^{\circ}C$ to $75^{\circ}C$ on Ag paste/anodised Al ($Al_2O_3$)/Al substrate to be used in metal PCB for high power LED packing systems. X-ray diffraction (XRD), Field-Emission Scanning Electron Microscopy (FE-SEM) and X-ray Photoelectron Spectroscopy (XPS) were used in the film analysis. By XRD result, the structure of the as deposited Ni-B film was amorphous irrespective of bath temperature. The activation energy of electroless Ni-B plating was 59.78 kJ/mol at the temperature region of $50{\sim}75^{\circ}C$. In addition, the Ni-B film grew selectively on the patterned Ag paste surface.

  • PDF

함정용 LED 투광등 설계 및 제작 (Design and Fabrication of a LED Floodlight for Naval Vessels)

  • 김세진;길경석;김동건;김일권;송동영
    • 한국전기전자재료학회논문지
    • /
    • 제26권10호
    • /
    • pp.771-777
    • /
    • 2013
  • This paper dealt with the development of a LED floodlight for naval vessels to replace the conventional floodlight using an incandescent and a halogen lamp. We found a technical solution for current problems of conventional lights and also improved optical characteristics by developing a LED floodlight which has a typical long-lived light source with high efficiency. To satisfy the requirements specified in Korea Standard Vessels (KS V), the optical structure was designed with selected LED package and lens. A LED module was composed of 10 LEDs in series for stable luminous output, and an aluminium heat sink was adopted for effective heat-radiation design. The LED floodlight was fabricated as a module type so that it can easily replace the conventional light source. The power consumption of the prototype floodlight was only a tenth of a conventional one with the same optical performance. Also, a test showed the floodlight satisfied the electrical, optical and environmental requirements of the standards.