• 제목/요약/키워드: Alternative test method

검색결과 715건 처리시간 0.028초

엘리베이터 하중시험 대체 검사기법 개발 (New Inspection Skill for Load-test of Hydraulic Elevator without Actual Loads)

  • 허윤섭;엄용기
    • 전기학회논문지P
    • /
    • 제62권3호
    • /
    • pp.127-132
    • /
    • 2013
  • In order to check traction of the elevator, the load-test is positively necessary on the inspection of elevator in Korea. So actual loads are used in the elevator car for the load-test. However, some of advanced countries in Europe, for example Germany, are using the alternative method with no load test instead of traditional load-test. Commonly hydraulic elevator, compared to passenger elevator is mainly used for loading heavy weights. It requires a great deal of labor to carry out load-test. The reason is why we developed a new inspection skill for the load-test of hydraulic elevator without actual loads. The results of studies show that the new method of the load-test can be replace the traditional load-test.

Non-Conservatism of Bonferroni-Adjusted Test

  • Jeon, Cyeong-Bae;Lee, Sung-Duck
    • Communications for Statistical Applications and Methods
    • /
    • 제8권1호
    • /
    • pp.219-227
    • /
    • 2001
  • Another approach (multi-parameter measurement method) of interlaboratory studies of test methods is presented. When the unrestricted normal likelihood for the fixed latent variable model is unbounded, we propose a me쇙 of restricting the parameter space by formulating realistic alternative hypothesis under which the likelihood is bounded. A simulation study verified the claim of conservatism of level of significance based on assumptions about central chi-square distributed test statistics and on Bonferroni approximations. We showed a randomization approach that furnished empirical significance levels would be better than a Bonferroni adjustment.

  • PDF

광감작성 시험에서의 동물대체 시험법 (Invirto alternatives to photosensitization Test)

  • 이호;남기택;고재숙;박원재
    • 대한화장품학회지
    • /
    • 제22권1호
    • /
    • pp.84-101
    • /
    • 1996
  • 동물시험을 최소화 하고, 동물시험에 사용되는 노력과 비용을 줄이기 위해 동일한 동물에서 광독성과 광알러지성을 함께 보는 새로운 방법을 제안하고, in vitro alternatives로서 photostability와 spectrophotometric carbonyl assay의 유용성을 검토하였다. Modified photosensitization model에서는 Ichikawa 방법과는 달리 동물수, 휴식 기간, 첩포 횟수를 단순히하고 폐쇄 첩포를 추가하였다. 방법의 유용성을 보기 위해 Benzocaine, 6-methyl coumarine을 Ichikawa 방법 및 본 시험 방법으로 결과를 비교한 결과 macroscopic, histologic examination에서 비슷한 결과를 얻었다. Photostability 시험에서는 pbotoreactive agent 들이 모두 20%이상의 흡광도 감소를 보여 pbotosensitization potential을 측정하기 위한 전 단계 실험으로서의 가능성을 보여주었고, spectrophotometric carbonyl assay에서는 salmonella를 이용한 광독성 실험에서는 나타나지 않았던 저농도의 Amthracene, Hematoporphyrin에서 조차도 phtotoxic prtential을 보여주어 in vitro alternatives로서의 가능성을 보여주었다.

  • PDF

피복류 건조속도 시험방법의 재현성 확보 방안 연구 (A Study on the Reliability of the Drying Rate Test about Military Clothes)

  • 이민희;홍성돈
    • 품질경영학회지
    • /
    • 제44권3호
    • /
    • pp.487-508
    • /
    • 2016
  • Purpose: Current testing method for drying rate used in military textiles has different results according to the public testing institute. So the purpose of this study was to suggest the alternative method which secure the reliability of the drying rate test. Methods: We measured the drying rate by various test methods for military clothes 14 species including quick drying function and compared the test results. Also, the collected data through the test was analyzed using one-way ANOVA. The p-value of results was compared by various testing institutions. Results: The results of this study are as follow; A deviation occurred among the testing institutions in original test method(KS K 0815). Whereas it is verified that there is no deviation among the institutions in 5% significance level by another test method(ISO 17617). Also it would increase work efficiency by reducing the testing time required to test by using ISO 17617. Conclusion: Based on the results, we can suggest the reliable test method of the drying rate.

피부흡수 대체시험법의 조건설정을 통한 수용성, 지용성 물질의 투과 특성 연구 (A Permeation Characteristics Study of Water- or Oil-soluble Substances through Condition Setting for the In Vitro Skin Absorption Method)

  • 서지은;이진호;김배환
    • 한국환경보건학회지
    • /
    • 제43권1호
    • /
    • pp.77-86
    • /
    • 2017
  • Objectives: The purpose of this study was to compare permeation characteristics in three skin types using oil-soluble benzoic acid and water-soluble caffeine after method condition optimization based on OECD guideline 428. Methods: A Franz diffusion cell, a reliable alternative method for skin permeation, was used. One-milliliter samples were taken and immediately replaced with fresh solution in the receptor chamber at regular time intervals (1, 2, 4, 7, 10 and 24 hr). The amount of test substances was measured by LC-MS/MS. Results: The permeation rate increased dose-dependently, and the permeation orders were $KeraSkin^{TM}$ > hairless mouse full skin > human cadaver epidermis for skin types, and benzoic acid solution > caffeine solution > benzoic acid cream > caffeine cream for type of test materials. Conclusion: According to the definitions of Marzulli, benzoic acid and caffeine would be classified as 'fast' and 'moderate' compared with the permeation of other chemical species. The setting conditions and permeation characteristics performed in this study are expected to contribute to future permeation studies.

Experimental and analytical behaviour of composite slabs

  • Lopes, Emanuel;Simoes, Rui
    • Steel and Composite Structures
    • /
    • 제8권5호
    • /
    • pp.361-388
    • /
    • 2008
  • The Eurocode 4 presents some negative aspects in the design of composite slabs by the m-k Method or the Partial Connection Method. On one hand, the component chemical adherence is not accounted for in the connection between the profiled steel sheet and the concrete. On the other hand, the application of these methods requires some fitting parameters that must be determined by full scale tests. In this paper, the Eurocode 4 methods are compared with a method developed at the Federal Polytechnic School of Lausanne, based on pullout tests, which can be a valid alternative. Hence, in order to calculate the necessary parameters for the three methods, several tests have been performed such as the full scale test described in Eurocode 4 and pull-out tests. This last type of tests is of small dimensions and implicates lower costs. Finally, a full-scale test of a steel-concrete composite slab with a generic loading is presented, with the goal of verifying the analytical formulation.

Combining Independent Permutation p-Values Associated with Multi-Sample Location Test Data

  • Um, Yonghwan
    • 한국컴퓨터정보학회논문지
    • /
    • 제25권7호
    • /
    • pp.175-182
    • /
    • 2020
  • 연속형 분포로부터 얻은 독립적인 p값들을 통합하는 Fisher의 고전적인 방법은 널리 사용되고 있지만 이산형 확률분포로부터 얻은 p값들을 통합하기에는 적절하지 않다. 대신에 유사 Fisher의 통합방법이 이산형 확률분포의 p값들을 통합하는 대안으로 사용된다. 본 논문에서는 첫째, 여러 표본들의 위치검정(Fisher-Pitman 검정과 Kruskal-Wallis 검정) 데이터와 관련된 이산형 확률분포로 부터 퍼뮤테이션 방법에 의해 p값들을 구하고, 둘째로 이 p값들을 유사 Fisher의 통합방법을 이용하여 통합한다. 그리고 Fisher의 고전적인 방법과 유사 Fisher의 통합방법의 결과를 비교한다.

이종재료의 결합방법에 따른 모자형 단면부재의 충돌실험 (Crushing Test of the Double Hat-shaped Members of Dissimilar Materials by Seining Methods)

  • 이명한;박영배;김헌영;오수익
    • 한국자동차공학회논문집
    • /
    • 제13권4호
    • /
    • pp.129-134
    • /
    • 2005
  • There is a strong industrial demand for the development of light-weight vehicle to improve fuel efficiency and dynamic performance. The effective method of achieving the weight reduction is to use low-density materials such as aluminum and magnesium. In applying these materials to the vehicle, it is often required to join dissimilar materials such as aluminum and steel. However, conventional joining method, namely resistance spot welding cannot be used in joining dissimilar materials. Self·piercing rivet(SPR) and adhesive bonding is a good alternative to resistance spot welding. In this study, the impact test of double hat-shaped member made by resistance spot welding, SPR and adhesive bonding was performed. As a result, various parameters of crashworthiness were analyzed and evaluated. Also, the applicability of SPR and adhesive bonding as an alternative to resistance spot welding was suggested.

Phototoxicity: Its Mechanism and Animal Alternative Test Methods

  • Kim, Kyuri;Park, Hyeonji;Lim, Kyung-Min
    • Toxicological Research
    • /
    • 제31권2호
    • /
    • pp.97-104
    • /
    • 2015
  • The skin exposure to solar irradiation and photoreactive xenobiotics may produce abnormal skin reaction, phototoxicity. Phototoxicity is an acute light-induced response, which occurs when photoreacive chemicals are activated by solar lights and transformed into products cytotoxic against the skin cells. Multifarious symptoms of phototoxicity are identified, skin irritation, erythema, pruritis, and edema that are similar to those of the exaggerated sunburn. Diverse organic chemicals, especially drugs, are known to induce phototoxicity, which is probably from the common possession of UV-absorbing benzene or heterocyclic rings in their molecular structures. Both UVB (290~320 nm) and UVA (320~400 nm) are responsible for the manifestation of phototoxicity. Absorption of photons and absorbed energy (hv) by photoactive chemicals results in molecular changes or generates reactive oxygen species and depending on the way how endogenous molecules are affected by phototoxicants, mechanisms of phototoxcity is categorized into two modes of action: Direct when unstable species from excited state directly react with the endogenous molecules, and indirect when endogeneous molecules react with secondary photoproducts. In order to identify phototoxic potential of a chemical, various test methods have been introduced. Focus is given to animal alternative test methods, i.e., in vitro, and in chemico assays as well as in vivo. 3T3 neutral red uptake assay, erythrocyte photohemolysis test, and phototoxicity test using human 3-dimensional (3D) epidermis model are examples of in vitro assays. In chemico methods evaluate the generation of reactive oxygen species or DNA strand break activity employing plasmid for chemicals, or drugs with phototoxic potential.

VFD(Vacuum Fluorescent Display) 가속열화시험 응용사례 (Application of Accelerated Degradation Testing for VFD (Vacuum Fluorescent Display))

  • 배석주
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제5권4호
    • /
    • pp.413-425
    • /
    • 2005
  • As an alternative to traditional life testing, degradation tests can be effective in assessing product reliability when measurements of degradation leading to failure can be observed. This article presents an accelerated degradation testing for vacuum fluorescent displays (VFDs). The accelerated degradation model is based on Arrhenius-lifetime relationship for cathode temperatures. We compare the results between accelerated degradation test and test at normal use condition. Accelerated degradation test for display devices is observed as an efficient method to warrantee product reliability to customers, as well as a tool to save time and costs.

  • PDF