• Title/Summary/Keyword: Alternative methods

Search Result 3,807, Processing Time 0.034 seconds

Science Teachers' Diagnoses of Cooperative Learning in the Field (과학교사들이 진단한 과학과 협동학습의 실태)

  • Kwak, Young-Sun
    • Journal of the Korean earth science society
    • /
    • v.22 no.5
    • /
    • pp.360-376
    • /
    • 2001
  • This qualitative research investigated in-service science teachers' perceptions about cooperative learning and their perceived barriers in implementing cooperative learning in their classrooms. The underlying premise for cooperative learning is founded in constructivist epistemology. Cooperative learning (CL) is presented as an alternative frame to the current educational system which emphasizes content memorization and individual student performance through competition. An in-depth interview was conducted with 18 in-service science teachers who enrolled in the first-class teacher certification program during 2001 summer vacation. These secondary school teachers's interview data were analyzed and categorized into three areas: teachers' definition of cooperative learning, issues with implementing cooperative learning in classrooms, and teachers' and students' responses towards cooperative learning. Each of these areas are further subdivided into 10 themes: teachers' perceived meaning of cooperative learning, the importance of talk in learning, when to use cooperative learning, how to end a cooperative class, how to group students for cooperative learning, obstacles to implementing cooperative learning, students' reactions to cooperative learning, teachers' reasons for choosing (not choosing) student-centered approaches to learning/teaching, characteristics of teachers who use cooperative learning methods, and teachers' reasons for resisting cooperative learning. Detailed descriptions of the teachers' responses and discussion on each category are provided. For the development and implementation of CL in more classrooms, there should be changes and supports in the following five areas: (1) teachers have to examine their pedagogical beliefs toward constructivist perspectives, (2) teacher (re)education programs have to provide teachers with cooperative learning opportunities in methods courses, (3) students' understanding of their changed roles (4) supports in light of curriculum materials and instructional resources, (5) supports in terms of facilities and administrators. It's important to remember that cooperative learning is not a panacea for all instructional problems. It's only one way of teaching and learning, useful for specific kinds of teaching goals and especially relevant for classrooms with a wide mix of student academic skills. Suggestions for further research are also provided.

  • PDF

Comparative analysis of auto-calibration methods using QUAL2Kw and assessment on the water quality management alternatives for Sum River (QUAL2Kw 모형을 이용한 자동보정 방법 비교분석과 섬강의 수질관리 대안 평가)

  • Cho, Jae Heon
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.5
    • /
    • pp.345-356
    • /
    • 2016
  • In this study, auto-calibration method for water quality model was compared and analyzed using QUAL2Kw, which can estimate the optimum parameters through the integration of genetic algorithm and QUAL2K. The QUAL2Kw was applied to the Sum River which is greatly affected by the pollution loads of Wonju city. Two auto-calibration methods were examined: single parameter application for the whole river reach and separate parameter application for each reach of multiple reaches. The analysis about CV(RMSE) and fitness of the GA show that the separate parameter auto-calibration method is better than the single parameter method in the degree of precision. Thus the separate parameter auto-calibration method is applied to the water quality modelling of this study. The calibrated QUAL2Kw was used for the three scenarios for the water quality management of the Sum River, and the water quality impact on the river was analyzed. In scenario 1, which improve the effluent water quality of Wonju WWTP, BOD and TP concentrations of the Sum River 4-1 station which is representative one of Mid-Watershed, are decreased 17.7% and 29.1%, respectively. And immediately after joining the Wonjucheon, BOD and TP concentrations are decreased 50.4% and 40.5%, respectively. In scenario 2, Wonju water supply intake is closed and multi-regional water supply, which come from other watershed except the Sum River, is provided. The Sum River water quality in scenario 2 is slightly improved as the flow of the river is increased. Immediately after joining the Wonjucheon, BOD and TP concentrations are decreased 0.18mg/L and 0.0063mg/L, respectively. In scenario 3, the water quality management alternatives of scenario 1 and 2 are planned simultaneously, the Sum River water quality is slightly more improved than scenario 1. Water quality prediction of the three scenarios indicates that effluent water quality improvement of Wonju WWTP is the most efficient alternative in water quality management of the Sum River. Particularly the Sum River water quality immediately after joining the Wonjucheon is greatly improved. When Wonju water supply intake is closed and multi-regional water supply is provided, the Sum River water quality is slightly improved.

Comparative Evaluation of Real-Time PCR and Conventional Culture Method Using Two Selective Agars for the Detection of Cronobacter spp. in Powdered Infant Formula and Dried Pumpkin (조제분유와 건조호박에서 Cronobacter spp. 검출을 위한 두 가지 선택배지와 Real-time PCR의 비교검증)

  • Kim, Hong-Seok;Shin, Minjung;Chon, Jung-Whan;Lim, Jong-Soo;Kim, Young-Ji;Kim, Dong-Hyeon;Chang, Ho-Seok;Kim, Hyunsook;Om, Ae-Son;Oh, Deog-Hwan;Song, Kwang-Young;Seo, Kun-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.6
    • /
    • pp.439-444
    • /
    • 2016
  • In the present study, the performance of culture methods using two selective agars and real-time PCR were compared for selective isolation of Cronobacter in powdered infant formula and dried pumpkin. Two food samples were spiked with the pathogen and then preenriched in distilled water. A small portion of preenrichment (10 mL) was incubated in Enterobacteriaceae enrichment both, followed by inoculation onto Druggan-Forsythe-Iversen agar (DFI agar) and Cronobacter sakazakii chromogenic plating agar (R&F agar). The preenrichment and enrichment (1 mL each) was used in real-time PCR assay. In powdered infant formula (PIF), no statistical difference was observed between both culture methods and real-time PCR with preenrichemt (p > 0.05). However, the number of positives obtained by R&F agar and real-time PCR was much higher than that of culture method using DFI agar in dried pumpkin (p < 0.05). In particular, R&F agar yielded a significantly greater selectivity than DFI agar in dried pumpkin (p < 0.05). Real-time PCR and R&F agar, which are currently recommended by US FDA, could be used as an alternative detection tools for the isolation of Cronobacter in PIF and ingredient of child foods such as dried pumpkin that has high number of competing natural microflora.

Characterization of Mutations in Bruton's Tyrosine Kinase(Btk) Gene from Unrelated 3 X-linked Agammaglobulinemia(XLA) Families in Korea (국내 X-관련성 범저감마글로불린혈증 세가족에 대한 Bruton's Tyrosine Kinase 단백질 발현 및 유전자 변이 분석)

  • Song, Chang-Hwa;Jo, Eun-Kyeong;Park, Jeong-Kyu;Kim, Jung-Soo;Hong, Soo-Jong;Lee, Jae-Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.3
    • /
    • pp.302-310
    • /
    • 2002
  • Purpose : X-linked agammaglobulinemia(XLA) is an immunodeficiency caused by abnormalities in Bruton's tyrosine kinase(Btk), and is characterized by a deficiency of peripheral blood B cells. We studied cytoplasmic expression of Btk protein and analyzed the Btk gene in peripheral blood mononuclear cells(PBMC) from three XLA families in Korea. Methods : Heparinized venous blood samples were collected from four XLA patients and additional family members in three unrelated XLA families. Mononuclear cells were separated from their blood and the intracellular Btk protein was characterized by a flow cytometry. The mutation analysis was performed using direct sequencing. Results : Cytoplasmic expression of Btk protein in monocytes was not detected in the patients with XLA. We observed a novel deletion and two point mutations within introns(intron 1 and intron 18) resulting in alternative splicings. In XLA family 2, a 980 bp deletion(from intron 9+191 T to intron 10-215 C) including exon 10 was found in patient P2. He was the only sporadic case in this study, because his mother and brother showed a normal Btk expression by flow cytometry. Conclusion : These identified genetic alterations support the molecular heterogeneity of Btk gene in XLA disease. Additionally, by means of flow cytometric analysis, we diagnosed three hypogammaglobulinemia patients as XLA. Advancements in diagnostic methods has facilitated a prompt and definite diagnosis of this disease.

Removal of As(III) in Contaminated Groundwater Using Iron and Manganese Oxide-Coated Materials (철/망간 산화물 피복제를 이용한 오염지하수에서의 As(III)제거)

  • Kim Ju-Yong;Choi Yoon-Hyeong;Kim Kyoung-Woong;Ahn Joo Sung;Kim Dong Wook
    • Economic and Environmental Geology
    • /
    • v.38 no.5 s.174
    • /
    • pp.571-577
    • /
    • 2005
  • Permeable reactive barrier using iron oxide coated sand is one of effective technologies for As(V) contaminated groundwater. However, this method is restricted to As(III), because As(III) species tends to be more weakly bound to adsorbent. In order to overcome the limitation of iron oxide coated sand application to As(III) contaminated groundwater, manganese oxide materials as promoter of As(III) removal were combined to the conventional technology in this study. For combined use of iron oxide coated sand and manganese oxide coated sand, two kinds of removal methods, sequential removal method and simultaneous removal method, were introduced. Both methods showed similar removal efficiency over $85\%$ for 6 hrs. However, the sequential method converted the As contaminated water to acid state (pH 4.5), on the contrary, the simultaneous method maintained neutral state (pH 6.0). Therefore, simultaneous As removal method was ascertained as a suitable treatment technology of As contaminated water. Moreover, for more effective As(III) remediation technique, polypropylene textile which has the characteristics of high surface area, low specific gravity and flexibility was applied as alternative material of sand. The combined use of coated polypropylenes by simultaneous method showed much more prominent and rapid remediation efficiency over $99\%$ after 6 hrs; besides, it has practical advantages in replacement or disposal of adsorbent for simple conventional removal device.

The Effects of a MR Torso Coil on CT Attenuation Correction for PET (PET/CT 검사에 있어서 MR Torso Coil의 CT 감쇄보정에 대한 영향 평가)

  • Lee, Seung Jae;Bahn, Young Kag;Oh, Shin Hyun;Gang, Cheon-Gu;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho;Seo, Soo-Hyun;Park, Yong Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.81-86
    • /
    • 2012
  • Purpose : Combined MR/PET scanners that use the MRI for PET AC face the challenge of absent surface coils in MR images and thus cannot directly account for attenuation in the coils. To make up for the weak point of MR attenuation correction, Three Modality System (PET/CT +MR) were used in Severance hospital. The goal of this work was to investigate the effects of MR Torso Coil on CT attenuation correction for PET. Materials and Methods : PET artifacts were evaluated when the MR Torso Coil was present of CTAC data with changing various kV and mA in uniformity water phantom and 1994 NEMA cylinderical phantom. They evaluated and compared the following two scenarios: (1) The uniform cylinder phantom and the MR Torso Coil scanned and reconstructed using CT-AC; (2) 1994 NEMA cylinderical phantom and the MR Torso Coil scanned and reconstructed using CT-AC. Results : Streak artifacts were present in CT images containing the MR Torso Coil due to metal components. These artifacts persisted after the CT images were converted for PET-AC. CT scans tended to over-estimate the linear attenuation coefficient when the kV and mA is increasing of the metal components when using conventional methods for converting from CT number. Conclusion : The presence of MR coils during PET/CT scanning can cause subtle artifacts and potentially important quantification errors. Alternative CT techniques that mitigate artifacts should be used to improve AC accuracy. When possible, removing segments of an MR coil prior to the PET/CT exam is recommended. Further, MR coils could be redesigned to reduce artifacts by rearranging placement of the most attenuating materials.

  • PDF

Detection of Campylobacter jejuni in food and poultry visors using immunomagnetic separation and microtitre hybridization

  • Simard, Ronald-E.
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2000.05a
    • /
    • pp.71-73
    • /
    • 2000
  • Campylobacter jejuni is most frequently identified cause of cause of acute diarrhoeal infections in developeed countries, exceeding rates of illness caused by both salmonella and shigilla(Skirrow, 1990 ; Lior 1994). Previous studies on campylobacter jejuni contamination of commercial broiler carcasses in u.s.(Stern, 1992). Most cases of the disease result from indirect transmission of Campylobactor from animals via milk, water and meat. In addition to Campylobactor jejuni. the closely relates species Campylobactor coli and Campylobactor lari have also been implicated as agents of gastroenteritis in humans. Campylobactor coli represented only approximately 3% of the Campylobactor isolates from patients with Campylobactor enteritis(Griffiths and Park, 1990) whereas Campylobactor coli is mainly isolated from pork(Lmmerding et al., 1988). Campylobactor jejuni has also been isolated from cases of bacteremia, appendicitis and, recently, has been associated with Guillai-Barre syndrome(Allos and Blaser, 1994; von Wulffen et al., 1994; Phillips, 1995). Studies in volunteers indicated that the infectious dose for Campylobactor jejuni is low(about 500 organisms)(Robinson, 1981). The methods traditionally used to detect Campylobactor ssp. in food require at least two days of incubation in an enrichment broth followed by plating and two days of incubation on complex culture media containing many antibiotics(Goossens and Butzler, 1992). Finnaly, several biochemical tests must be done to confirm the indentification at the species level. Therfore, sensitive and specific methods for the detection of small numbers of Campylobactor cells in food are needed. Polymerase chain reaction(PCR) assays targeting specific DNA sequences have been developed for the detection of Campylobactor(Giesendorf and Quint, 1995; Hemandex et al., 1995; Winter and Slavidk, 1995). In most cases, a short enrichment step is needed to enhance the sensitivity of the assay prior to detection by PCR as the number of bacteria in the food products is low in comparison with those found in dinical samples, and because the complex composition of food matrices can hinder the PCR and lower its sensitivity. However, these PCR systems are technically demanding to carry out and cumbersome when processing a large number of samples simutaneously. In this paper, an immunomagnetic method to concentrate Campylobactor cells present in food or clinical samples after an enrichment step is described. To detect specifically the thermophilic Campylobactor. a monoclonal antibody was adsorbed on the surface of the magnetic beads which react against a major porin of 45kDa present on the surface of the cells(Huyer et al., 1986). After this partial purification and concentration step, detection of bound cells was achieved using a simple, inexpensive microtitre plate-based hybridization system. We examined two alternative detection systems, one specific for thermophilic Campylobactor based on the detection of 23S rRNA using an immobilized DNA probe. The second system is less specific but more sensitive because of the high copy number of the rRNA present in bacterial cell($10^3-10^4$). By using specific immunomagnetic beads against thermophilic Campylobactor, it was possible to concentrate these cells from a heterogeneous media and obtain highly specific hybridization reactions with good sensitivity. There are several advantages in using microtitre plates instead of filter membranes or other matrices for hybridization techniques. Microtitre plates are much easier to handle than filter membranes during the adsorption, washing, hybridization and detection steps, and their use faciilitates the simultanuous analysis of multiple sample. Here we report on the use of a very simple detection procedure based on a monoclonal anti-RNA-DNA hybrid antibody(Fliss et al., 1999) for detection of the RNA-DNA hybrids formed in the wells.

  • PDF

Closed Integral Form Expansion for the Highly Efficient Analysis of Fiber Raman Amplifier (라만증폭기의 효율적인 성능분석을 위한 라만방정식의 적분형 전개와 수치해석 알고리즘)

  • Choi, Lark-Kwon;Park, Jae-Hyoung;Kim, Pil-Han;Park, Jong-Han;Park, Nam-Kyoo
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.182-190
    • /
    • 2005
  • The fiber Raman amplifier(FRA) is a distinctly advantageous technology. Due to its wider, flexible gain bandwidth, and intrinsically lower noise characteristics, FRA has become an indispensable technology of today. Various FRA modeling methods, with different levels of convergence speed and accuracy, have been proposed in order to gain valuable insights for the FRA dynamics and optimum design before real implementation. Still, all these approaches share the common platform of coupled ordinary differential equations(ODE) for the Raman equation set that must be solved along the long length of fiber propagation axis. The ODE platform has classically set the bar for achievable convergence speed, resulting exhaustive calculation efforts. In this work, we propose an alternative, highly efficient framework for FRA analysis. In treating the Raman gain as the perturbation factor in an adiabatic process, we achieved implementation of the algorithm by deriving a recursive relation for the integrals of power inside fiber with the effective length and by constructing a matrix formalism for the solution of the given FRA problem. Finally, by adiabatically turning on the Raman process in the fiber as increasing the order of iterations, the FRA solution can be obtained along the iteration axis for the whole length of fiber rather than along the fiber propagation axis, enabling faster convergence speed, at the equivalent accuracy achievable with the methods based on coupled ODEs. Performance comparison in all co-, counter-, bi-directionally pumped multi-channel FRA shows more than 102 times faster with the convergence speed of the Average power method at the same level of accuracy(relative deviation < 0.03dB).

Measurement of Two-Dimensional Velocity Distribution of Spatio-Temporal Image Velocimeter using Cross-Correlation Analysis (상호상관법을 이용한 시공간 영상유속계의 2차원 유속분포 측정)

  • Yu, Kwonkyu;Kim, Seojun;Kim, Dongsu
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.6
    • /
    • pp.537-546
    • /
    • 2014
  • Surface image velocimetry was introduced as an efficient and sage alternative to conventional river flow measurement methods during floods. The conventional surface image velocimetry uses a pair of images to estimate velocity fields using cross-correlation analysis. This method is appropriate to analyzing images taken with a short time interval. It, however, has some drawbacks; it takes a while to analyze images for the verage velocity of long time intervals and is prone to include errors or uncertainties due to flow characteristics and/or image taking conditions. Methods using spatio-temporal images, called STIV, were developed to overcome the drawbacks of conventional surface image velocimetry. The grayscale-gradient tensor method, one of various STIVs, has shown to be effectively reducing the analysis time and is fairly insusceptible to any measurement noise. It, unfortunately, can only be applied to the main flow direction. This means that it can not measure any two-dimensional flow field, e.g. flow in the vicinity of river structures and flow around river bends. The present study aimed to develop a new method of analyzing spatio-temporal images in two-dimension using cross-correlation analysis. Unlike the conventional STIV, the developed method can be used to measure two-dimensional flow substantially. The method also has very high spatial resolution and reduces the analysis time. A verification test using artificial images with lid-driven cavity flow showed that the maximum error of the method is less than 10 % and the average error is less than 5 %. This means that the developed scheme seems to be fairly accurate, even for two-dimensional flow.

Subjective and Functional Results after a Proximal Gastrectomy: Prospective Study for Comparison of Reconstruction Procedures (근위부 위절제술 후 재건 술식에 따른 경과 관찰)

  • Kim, Ji-Hoon;Yook, Jeong-Hwan;Kim, Byung-Sik;Oh, Sung-Tae
    • Journal of Gastric Cancer
    • /
    • v.6 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: A proximal gastrectomy is performed for gastric cancer in the upper part of the stomach to preserve the function of the stomach after surgery. An esophagogastrostomy is one of the common reconstruction methods for a proximal gastrectomy, but this method results in a high incidence of reflux esophagitis. This study was undertaken to compare subjective and functional results between esophagogastrostomy and jejunal interposition reconstructions. Materials and Methods: From June 1998 to December 2002, proximal gastrectomies were performed in 33 patients with tumors in the upper third of the stomach; 8 had reconstruction using jejunal interposition between the esophagus and the remnant stomach (JI group) while 25 had reconstruction using esophagogastrostomy (EG group). The postroperative courses of the patients were reviewed in terms of symptoms, weight changes, and endoscopic findings. Results: The mean age of the patients was 59 years; 26 were men and 7 were women. There were no significant differences in general complications, operating times, or histologic features between the two groups. Fifty-two percent (52%) of the EG group complained of dysphagia, and 16% them experienced heartburn and acid belching. Twelve percent (12%) of the JI group complained of dysphagia, but heartburn and acid belching did not occur. Incidences of reflux esphagitis (36%) and balloon dilatation for anastomotic stricture (16%) were more common in the EG group than in the JI group (0% and 12%). Conclusion: To prevent or minimize complications, such as reflux esophagitis and postoperative symptoms, a proximal gastrectomy with a jejunal interposition is an alternative method as an organ-preserving surgical strategy to improve quality of life for patients. (J Korean Gastric Cancer Assoc 2006;6:1-5)

  • PDF