• Title/Summary/Keyword: Alternating current(AC)

Search Result 162, Processing Time 0.031 seconds

A New Driving Waveform for Stable Address Discharge in an Alternating Current Plasma Display Panel

  • Kim, Sung-Hwan;Seo, Jeong-Hyun;Lee, Seok-Hyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.503-506
    • /
    • 2004
  • In this paper, we suggest a new driving waveform for stable address discharge in AC PDP without the reduction of contrast ratio. To analyze the influence of cross-talk between discharge and non-discharge cells and verify that proposed waveform shows a stable address discharge, we measured the address discharge delay time. The proposed waveform shows the reduction of the cross-talk and concurrently the improvement of address voltage margin compared with those of selective reset waveform having one reset period in 1TV-Field..

  • PDF

Characteristic Analysis of Voltage Stability Improvement and Power Factor Correction by STATCOM (STATCOM의 전압안정도개선 및 역률 보상 특성분석)

  • Park, Ji-Yong;Park, Duk-Hee;Han, Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.12
    • /
    • pp.1507-1513
    • /
    • 1999
  • This paper describes simulation and experimental results to analyze the dynamic characteristics of STATCOM, which is connected to the ac system for compensation the power factor and improving the voltage stability. The simulation and experimental results confirm that the scaled model for STATCOM can properly compesate the power factor of the load and regulate the bus voltage at the common connection point.

  • PDF

Heart beat interval measurement using an IBM PC (IBM PC를 이용한 심장 박동 간격의 측정)

  • 이동하;박경수
    • Journal of the Ergonomics Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.3-14
    • /
    • 1990
  • This article develops a cost-effective and accurate measurement system for heart best intervals. The system is composed of an analog to digital (A/D) converter, an IBM personal computer (an 8088 microprocessor, an 8253-5 timer, an 8259A interrupt controller, and memories) and assembler programs for controlling these hardware components. An exponential smoothing algorithm effectively reduced noise effects from A/D converted electrocardiogram (ECG) signals influenced by 60 Hz alternating current (AC). The system can collect 15000 heart beat intervals with an 1/5400 second unit.

  • PDF

탄소나노튜브를 함유한 고분자유기물의 AC 발광특성

  • Won, Beom-Hui;Jeon, So-Yeon;Yu, Se-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.510-510
    • /
    • 2013
  • 탄소나노튜브를 발광층에 첨가하여 Alternating current (AC) 방식으로 구동되는 고분자유기물 소자를 제작하였다. 고분자유기물 소자는 ITO가 코팅된 유리기판을 사용하였으며, 전극으로는 ITO와Al을 사용하고 cyanoethyl pullulan (CRS)의 유전물질과 탄소나노튜브를 함유한 poly[2-methoxy-z5-(2-ethyl-hexyloxy)-1,4-phenylene-vinylene](MEH-PPV) 고분자유기발광물질을 이용하여 4개의 층(ITO/CRS/탄소나노튜브를 함유한 MEH-PPV/Al)으로 고분자유기물 소자를 구성하였다. 소자는 ITO가 코팅된 유리 기판 위에 CRS의 유전층과 탄소나노튜브를 함유한 MEH-PPV의 발광층은 스핀코우터를 이용하여 증착하였으며, Al은 thermal evaporator을 이용하여 증착하였다. 본 연구에서는 AC 방식 고분자유기물 소자에 탄소나노튜브의 함유량을 변경하면서 전압과 전류 특성을 관찰하여 탄소나노튜브가 함유된 소자가 저 전류 구동이 가능한 것을 확인하였으며, 탄소나노튜브를 통한 micro-capacitance 효과의 확인 및 percolation과의 상관관계를 알아보았다. AC 고분자유기물 소자는 가정에서 사용되는 AC전원을 바로 사용할 수 있는 범용성을 가지고 있으며, 탄소나노튜브를 발광층에 첨가함으로 낮은 소비전력으로 고분자유기물 소자를 구동 할 수 있는 장점으로 차세대 디스플레이나 조명으로 그 쓰임새를 기대해본다.

  • PDF

Alternating-Current Electrical Conduction Properties of DyCoO3 Ceramics (DyCoO3 세라믹스의 교류전도특성)

  • Jung, Woo-Hwan
    • Korean Journal of Materials Research
    • /
    • v.20 no.3
    • /
    • pp.161-166
    • /
    • 2010
  • The ac, dc conductivity and dielectric properties of $DyCoO_3$ were reported in the temperature range of 77 - 300K and in the frequency range of 20 Hz - 100 kHz. It was observed that at low temperature, ac conductivity is much higher than dc conductivity and the hopping carrier between localized states near the Fermi level was the dominant loss mechanism. A comparison of the measured ac conductivity $\sigma(\omega)$ was made with some of the models of hopping conductivity of the proposed earlier in the literature. It was observed that in $DyCoO_3$ the measured ac conductivity, over the entire frequency and temperature region, can be explained reasonably well by assuming two contributions $\sigma_1(\omega)$ and $\sigma_2(\omega)$ to the measured $\sigma(\omega)$. The first, $\sigma_1(\omega)$, which dominates at low temperature, may be due to impurity conduction in a small polaron; the second, $\sigma_2(\omega)$, which dominates at higher temperatures, depending on the frequency of measurements, may be due to the hopping of a small polaron and is reasonable for the dielectric relaxation peak.

A Study on the Fuel Cell Equivalent Circuit Modeling (연료전지 수치해석을 이용한 등가회로 모델링 연구)

  • OH, HWANYEONG;CHOI, YOON YOUNG;SOHN, YOUNG-JUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.3
    • /
    • pp.226-231
    • /
    • 2022
  • Power converter are usually equipped for fuel cell power generation system to connect alternating current (AC) electric power grid. When converting direct current (DC) of fuel cell power source into AC, the power converter has a frequency ripple, which affects the fuel cell and the grid. Therefore, an equivalent circuit having dynamic characteristics of fuel cell power, for example, impedance, is useful for designing an inverter circuit. In this study, the current, voltage and impedance characteristics were calculated through fuel cell modeling and validated by comparing them with experiments. The equivalent circuit element values according to the current density were formulated into equations so that it could be applied to the circuit design. It is expected that the process of the equivalent circuit modeling will be applied to the actual inverter circuit design and simulated fuel cell power sources.

The Clinical Effect of High Voltage AC Reid Therapy(HEALTHTRON) on Peripheral Circulatory Disturbance and Functional Outcome of Rehabilitation in CVA Patients (교류고압전계요법이 뇌졸중환자의 말초혈류 및 재활기능에 미치는 효과에 대한 임상연구)

  • Sung Kang Keyng;Hwang Choong Yeon;Lee Sang Kwan;Lee So Young;Cheong Sang Su;Kang Se Young;Lee Jong Deck
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.3
    • /
    • pp.609-615
    • /
    • 2002
  • A medical treatment of alternating current high-voltage electric field therapy is a method in which we get a healing effect, applying electric field to an organism through an artificial device. In order to estimate the clinical effects of alternating current high-voltage electric field load(HEALTHTRON) on the rehabilitation of stroke patients, improvement of a peripheral blood circulation, and psychogenic symptom, we used BEUNZEUNGHEYNG Instrument, NIHSS(the National Institutes of Health Stroke Scale), FIM(Functional Independence Measure)lnstrument to research BEUNZEUNGHEYNG and recovery of rehabilitative funation. and also we used Thermography, Pulse Meter to measure body temperature and pulse, blood elements, and neuro modulators. We have reached the following conclusions after researching the clinical effects of alternating current high-voltage electric field therapy on the recovery of rehabilitative function and peripheral blood circulation. 1. HEALTHTRON efficiently has increased the volume of peripheral blood circulation in stroke patients. 2. HEALTHTRON rapidly has treated the symptoms of sleeplessness, alertness, and dizziness of stroke patients. 3. HEALTHTRON rapidly has improved rehabilitative function of stroke patients and the adjustment to their activities.

The Effects of Anodizing Process Parameters and Oxidation Temperature under Atmospheric Environment on Morphology of the Pure Titanium by Alternating Current Arc-anodizing (순티타늄의 교류 불꽃 양극산화층 미세조직에 미치는 양극산화공정변수 및 대기산화온도의 영향)

  • Yang, Hack-Hui;Park, Chong-Sung
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.1
    • /
    • pp.16-22
    • /
    • 2008
  • Anodizing to form oxide layers on the pure titanium was performed in the electrolyte containing 1.5M $H_2SO_4$, 0.2M $H_3PO_4$, and 2.5wt.% $CuSO_4$ using the ac-biased arc anodizing technique. Titanium oxide layers anodized with different applied voltages, voltage-elevating rates, and anodizing times were investigated. In addition, thermal oxidation test under an atmospheric environment for the arc-anodized specimens was carried out. The thickness of oxide layers were not affected by the voltage-elevating rates, but increased slightly with the increase of anodizing times. The thickness of oxide layers were increased with the increase of voltages, and increased remarkably in the condition of 200V. The size and number of the pore observed in the center of the porous cell were decreased with increase of applied voltage. From the result of thermal oxidation test, it revealed that oxide layer formed by arc anodizing more effective to prevent oxidation of pure titanium.

Electrofusion of Tobacco and Pea Protoplasts (전기장하에서의 담배 및 완두 원형질체 융합)

  • 서정우
    • Journal of Plant Biology
    • /
    • v.29 no.1
    • /
    • pp.1-10
    • /
    • 1986
  • Intra- and inter-specific protoplast fusion of tobacco (Nicotiana tabacum cv. Virginia 115) and pea (Pisum sativum cv. Sparkle) were carried out in highly inhomogeneous alternating electric fields. Under the electric field of alternating current (AC, sine wave), 600 V/cm and 800 kHz for tobacco protoplast, and 600 V/cm and 700 kHz for pea protoplasts, the protoplasts were aggregated in pearl chains. Intra-specific protoplast fusions were most effectively induced within the aggregates of tobacco and pea, respectively, by the additional application of a single high field pulse of direct current (DC, square wave) at 1 kV/cm for 50 $mutextrm{s}$. Inter-specific fusions between protoplasts of the two plants were most effectively induced in the electric field of 600 V/cm and 700 kHz, and square wave pulse at 1 kV/cm for 50 $mutextrm{s}$. The duration of the pulse over the electrical breakdown voltages was simulated from 1 to 100 $mutextrm{s}$ in both tobacco and pea protoplast. The yield of the electrofusion products was significantly high (above 60%), compared with that (20%) of the standard fusion method by polyethylene glycol (PEG) 4,000, and the viability of electrofused protoplasts was above 70%, but that of PEG-fused protoplasts 8~16%, when determined by Evan's blue staining method.

  • PDF

An Experimental Research On Nonlinear Characteristics Of Disk-Type Siliconcarbide Resistors With The Sinusoidal Alternating Currents (Silicon carbide저항소자의 교류 비선형특성에 관한 연구)

  • Cho, Chul;Oh, Myung-Hwan
    • 전기의세계
    • /
    • v.21 no.2
    • /
    • pp.25-33
    • /
    • 1972
  • The main focus of this paper is on the study of voltage-current characteristics in disk-type siliconcarbide resistors. For each of the 15 different sintering and other process conditions, 10 samples were prepared. Experiments performed with each sample consist of supplying sinusoidal AC current of a few miliamperes after conditioning-shots with 400ma. Experimental data were examined with regard to the relationship between the process conditions and the nonlinear resistivity. The examination suggests several possibilities of improving the nonlinlinear characteristics of siliconcarbide resistors while maintaining low resitance. One of those possible conditions is to sinter the powdered SiC and the binding materials approximately 2 hours in nitrogen. In addition to describing the nonlinear characteristics of siliconcarbide resistors, this paper also presents the distortion characteristics of current waves vs. the nonlinear exponent, n. Photographical results show that the more nonlinear characteristics samples have, the more distorted current waves are.

  • PDF