• Title/Summary/Keyword: Alpha-beam

Search Result 180, Processing Time 0.027 seconds

Study of cotton linter pre-treatment process for producing high quality regenerated fibers for fabrics (방직용 고품질 재생섬유 제조를 위한 면린터 전처리공정에 관한 연구)

  • Park, Hee Jeong;Han, Jung Su;Son, Ha Neul;Seo, Yung Bum
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.45 no.3
    • /
    • pp.27-35
    • /
    • 2013
  • Cotton linter pre-treatment methods using electron beam and sulfuric acid were investigated to prepare high quality regenerated fibers for fabrics. So far, NaOH was used to reduce the degree of polymerization (DP) of the cotton linter for ease of dissolving by cellulose solvent. Two pre-treatment methods were developed to reduce the consumption of the chemicals (NaOH) and to control the DP of cellulose more precisely. Changes in ${\alpha}$-cellulose contents and brightness by the pre-treatments were also important concerns. Both electron beam irradiation and sulfuric acid were shown to be effective on controlling the DP of cellulose and to reduce the chemical consumption, but reduced ${\alpha}$-cellulose contents as well in this study. Sulfuric acid pre-treatment, which needed additional washing process after the pre-treatment when comparing to the electron beam irradiation method, gave the highest brightness and the highest reduction of ${\alpha}$-cellulose content.

Cotton Linter Crystallinity Variations Caused by Electron Beam Irradiation and Acid Treatment (물리화학적 처리에 의한 린터의 결정성 변화에 관한 연구)

  • Park, Hee Jung;Sohn, Ha Neul;Seo, Yung Bum
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.46 no.4
    • /
    • pp.37-43
    • /
    • 2014
  • The crystallinity and molecular weight of cotton linter need to be controlled to be more easily dissolved in NMMO during manufacture of clothing fabrics. Electron beam irradiation and sulfuric acid treatment were used as pre-treatment to reduce molecular weight of cotton linter more efficiently, and after the pre-treatment, peroxide bleaching was followed in alkaline condition. After those processes, the crystalline indices of the cotton linters were measured by XRD method, and other properties such as their alpha cellulose contents and degree of polymerization were measured. It was found that the crystallinity index of cotton linter was decreased as the irradiation of electron beam increased while increased as the dose of sulfuric acid increased. These results strongly suggested that electron beam damaged the crystalline structure of the cellulose directly while sulfuric acid dissolved mostly non-crystalline area of the cellulose structure.

Measurement of the applicability of various experimental materials in a medically relevant reactor neutron source part two: Study of H3BO3 and B-DTPA under neutron irradiation

  • Ezddin Hutli;Peter Zagyvai
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2419-2431
    • /
    • 2023
  • Experiments related to Boron Neutron Capture Therapy (BNCT) accomplished at the Institute of Nuclear Techniques (INT), Budapest University of Technology and Economics (TUB) are presented. Relevant investigations are required before designing BNCT for vivo applications. Samples of relevant boron compounds (H3BO3, BDTPA) usually employed in BNCT were investigated with neutron beam. Channel #5 in the research reactor (100 kW) of INT-TUB provides the neutron beam. Boron samples are mounted on a carrier for neutron irradiation. The particle attenuation of several carrier materials was investigated, and the one with the lowest attenuation was selected. The effects of boron compound type, mass, and compound phase state were also investigated. To detect the emitted charged particles, a traditional ZnS(Ag) detector was employed. The neutron beam's interaction with the detector-detecting layer is investigated. Graphite (as a moderator) was employed to change the neutron beam's characteristics. The fast neutron beam was also thermalized by placing a portable fast neutron source in a paraffin container and irradiating the H3BO3. The obtained results suggest that the direct measurement approach appears to be insufficiently sensitive for determining the radiation dose committed by the Alpha particles from the 10B (n,α) reaction. As a result, a new approach must be used.

Construction of an Ultra High Vacuum Molecular Beam Epitaxy System and Optical Property of ZnSe/GaAs(001) Epitaxial films (초고진공 분자선 에피성장 시스템의 제작과 에피성장된 ZnSe/GaAs(001)의 광학특성)

  • Kim, Eun-Do;Son, Young-Ho;Eom, Gi-Seog;Cho, Seong-Jin;Hwang, Do-Weon
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.5
    • /
    • pp.458-464
    • /
    • 2006
  • The construction and the performance test of an ultra high vacuum (UHV) molecular beam epitaxy (MBE) system has been completed successfully. We have done domestic development and tried performance test for ultra high vacuum molecular beam epitaxy system. This system has reached pressure $2X10-^{10}$ Torr and the substrate has reached temperature $1,100^{\circ}C$. We have investigated into the characteristic of ZnSe/GaAs(001) by using scanning electron microscope (SEM), atomic force microscope (AFM), x-ray diffraction (XRD) and photolumi-nescence (PL).

Design Study of an Axial Injection System for MC50 Cyclotron at KIRAMS

  • Kim, Jae-Hong;Cho, Sung-Jin;Choi, Jun-Yong;Hong, Seung-Pyo;Yu, In-Gong;Park, Hyun;Lee, Ji-Sup
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.262-262
    • /
    • 2012
  • A multi-purpose cyclotron, MC50 has been operated to provide multi-ions of proton, deuteron and alpha at Korea Institute of Radiological and Medical Sciences (KIRAMS). Neutron is also produced through the (p,n) nuclear process with a Be target. However, a wide spectrum of current of ions is requested by beam users for carrying their various application fields. Therefore a simulation study is requested on the design of an axial injection system for high current proton and alpha beam extraction for radio-isotope productions and scientific researches. The purpose of this study is seeking a relatively simple method for the MC50 having higher alpha beam capability and also improving proton and deuteron beams currently used. We are considering two possibilities to improve the internal ion source and to install a new external axial injection system. The external injection system will be consisted of an Einzel lens, a steering magnet, a buncher, and a glazer lens placed in front of an inflector, which is located at the center of the main magnet.

  • PDF

Electron beam weldability of titanium alloy (타이타늄합금의 전자빔용접성)

  • Lee, Chae-Hun;Yun, Jong-Won;Park, No-Gwang
    • Laser Solutions
    • /
    • v.10 no.4
    • /
    • pp.13-17
    • /
    • 2007
  • Electron beam weldability was investigated for 1mm thick cold rolled sheets of commercially pure grade titanium and Ti-6Al-4V alloy. Accelerating voltage of 40kV, beam current of 6mA, and weld speed of 0.8m/min was used and focal position of focused electron beam was just on the surface of workpiece. Microstructure of weld metal, the heat affected zone and base metal was observed using optical microscope. Vickers hardness was measured across the welds and the transverse tensile test was carried out. Hydroformability test was also carried out for the butt welded coupons of commercially pure grade titanium. For the electron beam welded C P Ti, the average grain size was equiaxed $\alpha(15{\sim}25{\mu}m)$ for base metal, coarse equiaxed $\alpha(80{\sim}200{\mu}m)$ for weld metal and annealed and enlarged grain($40{\sim}120{\mu}m$) for the HAZ. The vickers hardness of C P Ti was $180{\sim}200Hv$ for base metal, and $160{\sim}180Hv$ for the weld metal and the HAZ. For the electron beam welded Ti-6Al-4V alloy, the vickers hardness was 360Hv for the base metal, abd $400{\sim}425Hv$ for the weld metal and the HAZ. All the failure occurred at the base metal, when the transverse weld tensile test was carried out for both electron beam welded C P Ti and Ti-6Al-4V alloy. The formability of electron beam welded C P Ti was decreased compared with that of C P Ti base alloy.

  • PDF

Evaluation of Biological Characteristics of Neutron Beam Generated from MC50 Cyclotron (MC50 싸이클로트론에서 생성되는 중성자선의 생물학적 특성의 평가)

  • Eom, Keun-Yong;Park, Hye-Jin;Huh, Soon-Nyung;Ye, Sung-Joon;Lee, Dong-Han;Park, Suk-Won;Wu, Hong-Gyun
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.280-284
    • /
    • 2006
  • $\underline{Purpose}$: To evaluate biological characteristics of neutron beam generated by MC50 cyclotron located in the Korea Institute of Radiological and Medical Sciences (KIRAMS). $\underline{Materials\;and\;Methods}$: The neutron beams generated with 15 mm Beryllium target hit by 35 MeV proton beam was used and dosimetry data was measured before in-vitro study. We irradiated 0, 1, 2, 3, 4 and 5 Gy of neutron beam to EMT-6 cell line and surviving fraction (SF) was measured. The SF curve was also examined at the same dose when applying lead shielding to avoid gamma ray component. In the X-ray experiment, SF curve was obtained after irradiation of 0, 2, 5, 10, and 15 Gy. $\underline{Results}$: The neutron beams have 84% of neutron and 16% of gamma component at the depth of 2 cm with the field size of $26{\times}26\;cm^2$, beam current $20\;{\mu}A$, and dose rate of 9.25 cGy/min. The SF curve from X-ray, when fitted to linear-quadratic (LQ) model, had 0.611 as ${\alpha}/{\beta}$ ratio (${\alpha}=0.0204,\;{\beta}=0.0334,\;R^2=0.999$, respectively). The SF curve from neutron beam had shoulders at low dose area and fitted well to LQ model with the value of $R^2$ exceeding 0.99 in all experiments. The mean value of alpha and beta were -0.315 (range, $-0.254{\sim}-0.360$) and 0.247 ($0.220{\sim}0.262$), respectively. The addition of lead shielding resulted in no straightening of SF curve and shoulders in low dose area still existed. The RBE of neutron beam was in range of $2.07{\sim}2.19$ with SF=0.1 and $2.21{\sim}2.35$ with SF=0.01, respectively. $\underline{Conclusion}$: The neutron beam from MC50 cyclotron has significant amount of gamma component and this may have contributed to form the shoulder of survival curve. The RBE of neutron beam generated by MC50 was about 2.2.

A study on the physical characteristics and conductivities of $\alpha$ -Sexithienyl thin films with various deposition conditions (성막조건에 따른 $\alpha$-Sexithienyl 박막의 물리적 특성 및 전기전도도에 관한 연구)

  • 박용인;권오관;오세운;최종선;김영관;신동명;강도열
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.91-94
    • /
    • 1997
  • $\alpha$-sexithienyl($\alpha$-6T) thin films were deposited by Organic Molecular Beam Deposition(OMBD) technique, where the $\alpha$-6T was synthesized and purified by the sublimation method. The thin films of the $\alpha$-6T were deposited under various deposition conditions. The effects of deposition rate, substrate temperature. and vacuum pressure an the formation of these films have been studied. The molecular orientations of $\alpha$-6T films were investigated with the polarized electronic absorption spectroscopy. The molecules in the $\alpha$-6T film deposited at a low deposition rate under a high vacuum were aligned almost perpendicular to the substrate. The film deposited at an elevated substrate temperature (~9 $O^{\circ}C$) showed higher conductivity than the film deposited at room temperature.

  • PDF

Contact and Electrical Characteristics of $\alpha$-67 Thin-Film for the fabrication of organic Thin-Film Transistor (유기 TFT 재작을 위한 $\alpha$&$-67 박막의 접촉 및 전기적 특성)

  • 오세운;김대엽;최종선;박미경;김영관;신동명
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.313-316
    • /
    • 1998
  • Conjugated oligomers have been already used as active layers in field effect transistors, photodiodes and electroluminescent devices. Particularly thiophene oligomers such $\alpha$ -sexithiophene($\alpha$-6T) attract great interest for its prospective app1ications in large-area flexible displays. In this study, we investigated the contact properties between the organic semiconductor $\alpha$-6T and metals such as Au(Gold), Ag(Silver), Cr(Chromium), Al(Aluminum), Cr(Chromium). Using the Transmission Line Model(TLM) method, specific contact resistances of the metal lines in contact with the $\alpha$-6T were determined. From the current-voltage characteristics, electrical conductivity of the $\alpha$-6T films is found.

  • PDF