• Title/Summary/Keyword: Allowable level

Search Result 336, Processing Time 0.026 seconds

Resource Allocation for Guaranteeing QoE in Mobile Communication Networks

  • Lee, Moon-Ho;Lee, Jong-Chan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.2
    • /
    • pp.45-50
    • /
    • 2017
  • This paper proposes a novel resource allocation scheme which allows to guarantee the user-perceived service quality for various high-quality mobile multimedia service such as interactive game, tactile internet service, remote emergency medical service or remote disaster handling robot control to a certain level in the mobile networks. In our proposed scheme, Mean Opinion Score(MOS), which represents the degree of user satisfaction for perceived quality, is determined based on the delay limit allowable to each service. Moreover resources are allocated in consideration of this MOS. Simulation results show that our proposed scheme can decrease the outage probability in comparison with existing schemes Moreover it can increase the total throughput as well.

Analysis of Insulating Reliability in Epoxy Composites using Weibull Distribution Equation (와이블 분포식을 이용한 에폭시 복합체의 절연 신뢰도 분석)

  • Park, No-Bong;Lim, Jung-Kwan;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.813-816
    • /
    • 2003
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were applied to Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased, the stronger breakdown strength became at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher. Finally, according to Weibull distribution analysis, reducing breakdown probability of equipment insulation lower than 0.1 % level requires the allowable field intensity values to be kept under 21.5 MV/cm.

  • PDF

Resonance initial current compensation for Resonant DC-Link inverter (공진 DC-Link 인버터의 공진 초기전류의 보상에 관한 연구)

  • Kwak, Dong-Kurl;Suh, Ki-Young;Kwon, Soon-Kurl;Lee, Hyun-Woo;Woo, Jung-ln
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1136-1141
    • /
    • 1992
  • This paper proposes a control technique to obtain high frequency quasi sinusoidal DC-Link waveform permitting zero-voltage-switching(ZVS). This operation results in reduction of commutation stress and switching losses in the power devices because they cause no switching loss in principle. But in existing control methods, the resonant capacitor voltage is not frequently made of zero-cross oscillation. We propose an optimum control stratege which can sustain oscillation and keep the capacitor voltage at an allowable level. Some experimental results are included to confirm the validity of the analytical results.

  • PDF

A TMR Budget Design for 100kTPI Hard Disk Drives Using a Head Gimbal Assembly with Radial Motion Capability (100kTPI급 하드 디스크 드라이브 TMR 설계를 위한 SUSPENSION에 관한 연구)

  • Oh, Dong-Ho;Kang, Seong-Woo;Han, Yun-Sik;Kim, Young-Hoon;Koh, Jeong-Seok;Hwang, Tae-Yeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.140-145
    • /
    • 2002
  • In high-capacity disk drives with ever-growing track density, the allowable level of position error signal (PES) is becoming smaller and smaller. A substantial portion of the PES is caused by disk vibration. This can be reduced by using a head gimbal assemblies (HGAs) that do not confine the slider movement to the vertical direction to disks, but allow movement to the radial direction of disks with respect to disk vibration. Several types of HGAs are proposed for such radial motion of the slider. Experimental results show that the PES levels are reduced by the proposed HGA-design concepts.

  • PDF

Interaction force analysis by peak value tracking in optical soliton transmission system (광 솔리톤 전송 시스템에 있어서 최대치 추적에 의한 상호 작용력 분석)

  • 변승우;송재원
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.7
    • /
    • pp.15-22
    • /
    • 1996
  • In the soliton transmission system for a long-length and high bit rate data transmission systme using the nonlinear/dispersive optical fibers, the improtant problem is the loss characteristics and is the limited transmission rate by interaction forces. In this paper, It is explained the reasons of moved time position for the soliton peak value due to interaction force sof adjacent solitons. And for the analysis of interaction force affection level in the losslessmedia, we define the percent parameter of error rate due to the interaction forces and propose the optimum time distance of adjacent solitons by peak value tracking methods. With the results, initial percent of error is approximately 50% when itme difference between adjacent solitons is 5 times of funddametnal soliton pulse width. And it is confirmed that maximum transmission length of th esolitons is approximately 38 times of fundamental soliton period, which the maximum allowable percoent of error is 50%.

  • PDF

Gate Pier damage assessment by vessel collision (선박충돌에 따른 콘크리트 배수갑문 교각 구조해석)

  • Kim, Kwan-Ho;Cho, Jae-Yong;Cho, Young-Kweon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.165-166
    • /
    • 2010
  • Collision scenario was 12 cases considering gate location, water level and lateral location of collision etc. And then, analysis result of trunnion by collision loads (reservoir side gate). Compressive fracture may not occur because the maximum compressive stress of concrete is below the allowable compressive strength. but, it is possible to appear some local crack because the maximum tensile stress exceed the tensile strength.

  • PDF

Steam Generator Management Program (원전 증기발생기 관리프로그램)

  • Cho, Nam-Cheoul;Kim, Moo-Soo;Lee, Kwang-Woo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.610-616
    • /
    • 2003
  • Recently, the common concern of nuclear power industry in the development of technology mitigating and preventing the aging of steam generator tubes prevails, because the trends of steam generator flaws at Uljin unit #1,2 and KSNP(Korea Standard Nuclear Power Plant) impose a burden on the operation of nuclear power plant. While the regulatory agency is demanding the establishment of the advanced general performance maintenance system, the steam generator management program adapting advanced technology is being developed which may comply with EPRI PWR SG Guidelines based on NEI 97-06 ‘ General Guidelines including all the maintenance aspects consist of the tube integrity assessment criteria, repair limit, allowable leakage level, water chemistry will be composed in order to obtain the approval of regulatory agency and be applied to Nuclear power plant early 2005. This presentation is to introduce maintenance state including SG tube degradation and main contents of advanced SG management program being developed, and futhermore update present and future plan, and estimate the alternation after the completion.

  • PDF

Coupled Oil-Structure Analysis for Piston Motion in Reciprocating Compressors (윤활-구조물 연계해석을 이용한 왕복동형 압축기의 피스톤 거동해석)

  • Moon, Seung-Ju;Cho, Jin-Rae;Ryu, Sung-Hyon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.513-518
    • /
    • 2003
  • The piston slap phenomenon is one of the major noise source of reciprocating compressors used in household electric appliances. In response to public demand, strict regulations are increasingly being imposed on the allowable noise level which is caused mostly by household electric appliances. In this paper, the dynamic behavior of suction and discharge valves are analytically calculated and the lubricant behavior between piston and cylinder are investigated using two-dimensional Reynolds equation. And the piston slap caused by the piston secondary motion is investigated by the finite element method.

  • PDF

Isolation Technique of Shock Transfer Path of the Microdrive for Shock Resistance Improvement (마이크로 드라이브의 충격 저감을 위한 충격 전달 경로 절연 기법)

  • Kim, Do-Gyoon;Lee, Jun-Hwa;Kim, Kwang-Joon;Byun, Yong-Kyu;Han, Woo-Sup;Hong, Min-Pyo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.717-722
    • /
    • 2003
  • To improve the shock resistance of the microdrive under non-operating conditions, an isolator was attached to the contacting part of the microdrive. Through FE analysis, design parameters for satisfying the allowable acceleration level of the spindle motor bearing part were presented, which is a most possible critical part of the microdrive.

  • PDF

Excess Vibration Phenomena and Soundness of Drain Piping in Moisture Separator Reheat Exchanger (습분 분리 재열기 배수배관의 과도진동과 배관 건전성)

  • Kim, Yeon-Whan;Kim, Hee-Soo;Bae, Yong-Chae;Lee, Hyun;Lee, Young-Shin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.393-398
    • /
    • 2001
  • Pulsations, vibration and stress are the basic dynamic phenomena in power plant piping systems which directly affect system reliability. These phenomena are both acoustical and mechanical in nature and are closely interrelated. It was noticed that thermodynamic parameters were changed after replacing with new type tube bundles of reheat exchanger. It was reported later that the drain piping connecting the new bundle header with the associated drain tank is regularly pulsating at about every 3 second with 13.4㎐ and 7.5mm, p-p in amplitude. This amplitude is about 6 times higher than reference level of sound piping. The results of finite element analysis of the pipeline showed that its dominant natural frequency is 13.4㎐. The soundness is predicted whether the bending dynamic stress evaluated excesses the maximum allowable high cycle fatigue stress or not by the measured amplitude of vibration.

  • PDF