• 제목/요약/키워드: Allowable level

검색결과 338건 처리시간 0.033초

진동 규제기준에 따른 인체의 허용 한계거리 예측 (The Prediction of Allowable Limit Distance about Human Body by Vibration Regulation)

  • 송정언;홍웅기;김승곤
    • 환경영향평가
    • /
    • 제21권2호
    • /
    • pp.289-296
    • /
    • 2012
  • The shock vibration such as machine vibration, blasting vibration etc. has effect on nearby structure as well as human body. The purpose of this study is to predict allowable limit distance of vibration about human body. First of all, vibration velocity such as PPV, PVS was measured by shock vibration experiment, and vibration level was calculated by conversion formula of vibration velocity. And then, allowable limit distance was analyzed by converted vibration level. The results are as follows : Firstly, the correlation coefficient of converted vibration level was over R=0.94, and vibration level caused by PVS was usually represented to high curve line. Secondly, the cross point of vibration level between ground and concrete condition was represented to 66.68dB(V), and allowable limit distance was represented to difference over three times when vibration regulation was raised from 65dB(V) to 80dB(V).

Evaluation of Allowable Bending Stress of Dimension Lumber; Confidence Levels and Size-adjustment

  • Pang, Sung-Jun;Lee, Jun-Jae;Oh, Jung-Kwon
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권5호
    • /
    • pp.432-439
    • /
    • 2013
  • The aim of this study was to investigate the processes for evaluating the allowable bending stress. The confidence levels and the size-adjustment in standards were reviewed with experimental data. The results show that, (1) KS F 2152 was more strict than others overseas standards due to the higher confidence level. The 5% NTL of bending strengths by a method in KS F 2152 were lower than the overseas standards and more specimens were required for evaluating the structural properties according to KS F 2152. (2) Due to the absence of size-adjustment method in domestic standards, the specified size and the exponential parameters on the size-adjustment equation were reviewed by size factors. The specified size (width: 286 mm, length: 6096 mm), and the exponential parameters (w: 0.29, l: 0.14) will be suitable for developing the allowable bending stress in domestic standard. (3) The size adjusted allowable bending stresses of No. 2 grade Korean pine were lower than the allowable stresses tabulated in KBC even though less strict method (75% confidence level) to calculate 5% value was used. The allowable stresses tabulated in KBC are needed to be reviewed by continuous experimental data.

발파진동 제어에 의한 특수구간 터널굴착에 관한 연구 (A Study on Tunnel Excavation by Controlled Blast Vibration at Particular Environment Conditions)

  • 최형빈;임한욱
    • 산업기술연구
    • /
    • 제20권A호
    • /
    • pp.257-267
    • /
    • 2000
  • It was difficult to apply conventional excavation methods in some sections from Seoul to Pusan high speed rail road construction of 1 lot 2, due to highway concrete road, gas pipe, water pipe and nearby factories with automatic control system machine. To excavate safely and efficiently in these sections new blast patterns were employed within allowable blast vibration level, by test blast and controlled vibration by sequential blast. Behaviors of the rock mass including convergence and displacement around tunnel were measured with construction works and the crack width in concrete wall was also monitored for controlling allowable limits. The results can be summarized as follow : 1. The allowable blast vibration level in structure site is less 1.0cm/sec for highway concrete, 0.5 cm/sec for gas pipe, water pipe and building housing and 0.3 cm/sec for automatic control system machine. 2. The convergence displacement, single rod extensometer and multi rod extensometer around tunnel and cracks in concrete wall were measured, it was confirmed that the measured values were converged within allowable level. 3. The empirical formular of ground vibrations with 90% confidence lines for PD-3 was given as follow. $$V_{90%}=45.549({\frac{D}{\sqrt{W}}})^{-1.353}$$

  • PDF

국내 적용되고 있는 흙막이구조물의 축력에 대한 관리기준치 분석 (A Control Value Analysis on the Axial Force of Braced Excavation Walls Used In Korea)

  • 정상국;이광찬;이송
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권4호
    • /
    • pp.171-180
    • /
    • 2000
  • This study aims to present a more reasonable control value than the exiting one by comparing and analyzing control values and field instrumentation values of the whole excavation depth of the four case sites using geometric averaging as a statistical method. The range of the study is confined to three things: (1) the axial force of the braced excavation walls among a variety of items prescribed in the control values by stress deformation of walls and adjacent structures; (2) by approximation of the allowable and design value; (3) and by safety factor. As a res it is desirable to revise "(Long term allowable stress + Short term allowable stress)/2 ~ Short term allowable stress," presented in the present control values by stress deformation of walls and adjacent structures, to "(Long term allowable stress + Short term allowable stress)/5 ~ (Short term allowable stress)/3." The result also shows that since there is a difference of about 3.5%, it is not necessary to revise 70, 90, and 100 percent of LEVEL I, II, and III, prescribed in the control values by the allowable and design value approximation. In addition, modifying the control value by the safety factor, now 1.07, is unnecessary, although it varies little difference from the present value.

  • PDF

천장형 에어컨 소음의 허용 음압레벨 도출 (Allowable sound pressure levels of ceiling mounted air-conditioning sounds)

  • 유진;정충일;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.689-692
    • /
    • 2008
  • Noises from ceiling mounted air-conditioning units were recorded in various actual situations such as offices, classrooms and libraries. Eight specimens of air-conditioners from major domestic and foreign manufacturers' were investigated in this study. A head and torso simulator was located 1.5 m beneath the air-conditioner panel for the measurements and sound pressure levels of the recording sounds were varied from 28 to 55 dBA with 3 dB steps for subjective evaluations. A total of 88 stimuli was randomly presented to subjects using a headphone system in semi-anechoic chamber. Two-categorized (noisiness and amenity) nine-point scale was used as evaluation method. The third scale ('point 3') among the nine-point scale was set as the threshold of allowable level of the air-conditioning sounds in consideration of the real situations. The results indicate that the allowable sound pressure level is around 34 dBA for both noisiness and amenity categories.

  • PDF

판매자와 구매자의 재고상한이 존재하는 VMI (VMI with Upper Limit of Inventory for Vendor and Retailer)

  • 이동주
    • 산업경영시스템학회지
    • /
    • 제40권4호
    • /
    • pp.105-111
    • /
    • 2017
  • Vendor Managed Inventory is a well-known vendor-retailer coordination approach in supply chain management where the vendor manages inventory of the retailer and determines the order interval and order quantity for the retailer. To consider practical situation, the upper limit of inventory for the retailer is set. If the inventory level for the retailer exceeds the upper limit, then the penalty cost is charged to the retailer. Furthermore, maximum allowable inventory level is set for the vendor to prevent the vendor from keeping much inventory. Single-vendor multi-retailer supply chain model with upper limit of inventory for vendor and retailers is studied. All the retailers' are assumed to have the common cycle time, and a vendor manages retailers' inventory and replenishes products. The mathematical formulation is introduced to minimize the total cost including the penalty cost violating the upper limit of inventory for retailers with the constraint of maximum allowable inventory level. The solution procedure based on Karush-Kuhn-Tucker (KKT) conditions is derived. KKT conditions are often applied to find an optimal solution of nonlinear programming problem with constraints. An illustrative example is used to show the application of the proposed solution procedure. Furthermore, sensitivity analysis is done to find out the relationship between maximum allowable inventory level and other values such as order quantity, the number of shipment, vendor's cost, retailer's cost, and total cost. As maximum allowable inventory level decreases, the number of shipment decreases but total cost increases. Order quantity has the trend of decline and is affected by the number of shipment.

부산 통신구굴진 발파작업으로 인한 지상주택 구조물에 미치는 진동폭음영향계측조사보고 (On the study of the measurement of blasting Vibration and Sound influenced to housing structure at Wire-Tunnelling)

  • 허진
    • 화약ㆍ발파
    • /
    • 제8권2호
    • /
    • pp.3-17
    • /
    • 1990
  • The Caustious blasting have often increased Complaints of ground Vibration and Sound when the Wire-Tunnel Constructed in Pusan. In order to prevent the influence to housing structure, it was necessary to predict blasting-Induced Vibration and Sound. The Suveyer determined the Burden and spacing of Drill holes, minimum delay charges within a allowable Vibration and Sound Level. Tunnel drilling and Ignition patterns are made as follows; No. 1 Tunel (Stable rock, hard rock) No.2 Tunnel (Instable plastic rock; wethered rock) and other Tunnels (Instable rock). The result of 1st testing blasting of No. 1 Tunnel was recorded Under allowable Vibration Level but sound was over 75 Db of allowable value. So Tunnel drilling pattern was amended with 52 Non-charg holes to reduce the blast-sound. The other pattern had no need to amend.

  • PDF

드론 영상을 이용한 하천의 구간별 허용 저수량 산정 방법 개발 (Development of a Method for Calculating the Allowable Storage Capacity of Rivers by Using Drone Images)

  • 김한결;김재인;윤성주;김태정
    • 대한원격탐사학회지
    • /
    • 제34권2_1호
    • /
    • pp.203-211
    • /
    • 2018
  • 댐 방류는 장마 또는 가뭄 등을 원인으로 하천과 하천 주변 지역의 관리를 위해 시행되고 있다. 댐 방류는 하천에서 수용할 수 있는 저수량을 정확하게 파악하는 것이 전제되어야 한다. 따라서 하천의 허용 저수량 파악은 하천 주변 환경 관리에 중요한 요소라고 할 수 있다. 하지만 현재 하천의 허용 저수량 파악에 사용되고 있는 수위계측기, 영상을 이용한 방법들은 정확성, 효율성 등의 측면에서 한계점을 보인다. 따라서 이를 해결하기 위해 본 논문에서는 드론으로 촬영한 영상을 기반으로 하천의 허용 저수량을 자동으로 계산하는 방법을 제안한다. 본 논문이 제안하는 방법은 크게 두 단계로 수행된다. 첫 번째 단계에서는 드론 영상을 이용하여 하천의 3차원 모델을 생성한다. 이 생성 과정은 대응점 추출, 영상 표정, 영상 정합 단계로 구성된다. 두 번째 단계에서는 생성된 하천 3차원 모델과 대상지역의 도로 및 하천 레이어를 이용하여 하천 단면 분석을 통해 허용 저수량을 산정한다. 이 단계에서는 하천의 최대 수위를 결정하고 하천을 따라 단면 프로파일을 추출, 3D 모델을 사용하여 대상지역 전체에 대한 허용 유량을 산정한다. 제안한 방법을 실험하기 위하여 북한강 일대의 데이터를 사용하였고, 결과적으로 허용 저수량을 자동으로 추출할 수 있었다. 제안한 방법은 하천과 그 주변지역의 실시간 관리 및 드론 영상을 활용한 3D 모델 활용에 큰 도움이 될 것이라 기대된다.

인공지능 모델에 의한 지하수위 모의결과의 적절성 판단을 위한 허용가능한 예측오차 범위의 추정 (Estimation of the allowable range of prediction errors to determine the adequacy of groundwater level simulation results by an artificial intelligence model)

  • 신문주;문수형;문덕철;류호윤;강경구
    • 한국수자원학회논문집
    • /
    • 제54권7호
    • /
    • pp.485-493
    • /
    • 2021
  • 지하수는 지표수와 함께 용수로 사용가능한 중요한 수자원이며 특히 섬 지역의 경우 전체 수자원 중 지하수의 이용 비율이 상대적으로 높기 때문에 안정적인 이용을 위해 지하수위 변동성에 대한 연구는 필수적이다. 지하수위 변동성의 예측 및 분석을 위해 인공지능 모델을 활용한 연구들이 지속적으로 증가하고 있으나 지하수위 예측결과의 적절성을 판단할 수 있는 평가기준을 제시한 연구는 충분하지 않다. 본 연구에서는 허용가능한 지하수위 예측오차의 범위를 제시하기 위해 과거 20년 동안 전 세계 다양한 지역을 대상으로 인공지능 모델을 활용하여 지하수위를 예측한 연구결과들을 종합적으로 분석하였다. 그 결과 관측지하수위의 변동성이 커질수록 인공지능 모델에 의한 지하수위 예측오차는 증가하였다. 따라서 관측지하수위 최대변동폭과 예측오차 간의 상관성과 기존 연구들에서 제시한 평가지수들을 고려하여 평가기준을 산정하였으며, 인공지능 모델에 의한 지하수위 예측결과의 적절한 평가기준은 도출된 선형회귀식에 의한 평균제곱근오차 또는 최대오차 이하이거나, NSE ≥ 0.849 또는 R2 ≥ 0.880 이다. 이 허용가능한 오차범위는 인공지능 모델을 활용한 지하수위 예측결과의 적절성 판단을 위한 참고자료로 사용할 수 있다.

저온해역에서의 해양구조물에 대한 구조신뢰성 해석 (Structural reliability analysis of offshore structure at cold region)

  • 이주성
    • 한국해양공학회지
    • /
    • 제11권3호
    • /
    • pp.8-19
    • /
    • 1997
  • In this study an adequate type of offshore structure at the Sakhalin region as cold region is proposed and its structural design results are presented based on the reliability analysis. Structural safety assessment has been carried out for the proposed offshore structure at the Sakhalin area as designed by the reliability method. And a rational design procedure is presented based on the reliability analysis. Followings are drawn through the present study : - Four colum TLP structure is proposed as an adequate offshore structure type at the cold region like the Sakhalin region and the reliability-based structural design results are presented. It is seen that the proposed type is a more adequate and economic than the fixed type. - Safety assessment of the proposed structure applying the extended incremental load method is performed. - Referring the allowable safety level for offshore structures it has been found present TLP structure has sufficient structural safety at the system level as well as at the component level.

  • PDF