• 제목/요약/키워드: Allowable design values

검색결과 115건 처리시간 0.022초

일체형원자로 SMART의 나선형 증기발생기 전열관 코일링 시 스프링백 최소화 방안 (Minimization of the Spring back in the Coiling Process of the Helical Steam Generator Tubes of Integral Reactor SMART)

  • 김용완;김종인;장문희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.837-842
    • /
    • 2000
  • In the coiling process of helical steam generator tubes of integral reactor SMART, a considerable amount of spring back, which induces dimensional inaccuracy and difficulty in fabrication, has been arised. In this research, an analytical model was derived to evaluate the amount of the spring back for steam generator tubes. The model was developed on the basis of beam theory and elastic-perfectly plastic material property. This model was extended to consider the effect of plastic hardening and the effect of the tensile force on the spring back phenomena. Parametric studies were performed for various design variables of steam generator tubes in order to minimize the spring back in the design stage. A sensitivity analysis has shown that the low yield strength, the high elastic modulus, the small helix diameter, and the large tube diameter result in a small amount of the spring back. The amount of the spring back can be controlled by the selection of adequate design values in the basic design stage and reduced to an allowable limit by the application of the tensile force to the tube during the coiling process.

  • PDF

간척지 온실기초 보강을 위한 심층혼합처리공법의 허용지내력 및 침하량 산정 (Estimation of Allowable Bearing Capacity and Settlement of Deep Cement Mixing Method for Reinforcing the Greenhouse Foundation on Reclaimed Land)

  • 이학성;강방훈;이광승;이수환
    • 생물환경조절학회지
    • /
    • 제30권4호
    • /
    • pp.287-294
    • /
    • 2021
  • 국가관리 간척지내 원예단지 조성에 필요한 기반기술 중에 하나인, 온실기초 연구가 부족한 실정이며 고사양의 PHC파일을 대체하기 위한 대안을 검토하고자 하였다. 지반개량공법 중 심층혼합처리공법(DCM) 적용시 허용지지력과 침하량 산정을 통하여 온실기초 공법으로써의 적용가능성을 검토하였다. 새만금간척지 농생명용지 1공구 지반조사를 통해 지반 특성을 파악하고, Terzaghi, Meyerhof, Hansen, Schmertmann 이론식을 적용하여 허용지지력과 침하량을 산정하였다. 직경 800mm를 기준으로, 독립 기초 폭과 길이가 3-6m이고, 기초 심도 3-7m 조건에서 허용지지력과 침하량을 검토하였다. 온실기초 심도가 얕고 콘크리트 매트 간격이 넓을수록 시공비가 절감되는 측면을 고려하여 독립 기초 폭과 길이가 4m, 기초 심도가 3m인 경우가 가장 적합한 것으로 판단되었다. 독립 기초 폭과 길이가 4m이고, 기초 심도가 3m인 조건에 대한 해석 결과로 허용지지력은 169kN/m2, 침하량은 2.73mm로 지지력은 이론식 대비 5.6%의 오차를, 침하량은 62.3%의 오차범위를 나타냈다. 향후, 위 검증된 설계 값을 기준으로 구조 시험과 침하모니터링을 통해 신뢰성을 검증하고자 한다. 그 외 나무말뚝, 헬리컬기초 등 유리온실, 내재해형온실에 적용 가능한 기초 공법과의 비교 검증을 통해 각각의 장, 단점을 파악하고 PHC 파일의 대체 가능 유무를 검토할 예정이다. 이는 온실 유형별 시공 공법을 선정하는데 필요한 기초 데이터로 제시될 수 있을 것으로 기대된다.

철근(鐵筋)콘크리트기둥의 신뢰성(信賴性) 설계규준(設計規準)에 관한 연구(研究) (A Study on Reliability Based Design Criteria for Reinforced Concrete Columns)

  • 조효남;민경주
    • 대한토목학회논문집
    • /
    • 제3권1호
    • /
    • pp.25-33
    • /
    • 1983
  • 현행(現行) 콘크리트 표준시방서(標準示方書)에서 WSD 또는 USD로 설계(設計)되는 R.C. 기둥의 설계규준(設計規準)에서 보다 합리적(合理的)인 설계(設計)가 될 수 있는 신뢰성(信賴性) 설계규준(設計規準)을 제안(提案)하는 것이 본(本) 연구(硏究)의 핵심(核心)이다. Cornell의 MFOSM 이론(理論)에 의(依)해 R.C. 기둥 저항(抵抗)의 불확실량(不確實量) 산정(算定) 알고리즘을 유도(誘導)하여 저항(抵抗)의 불확실량(不確實量)을 산정(算定)했으며, 하중(荷重)의 불확실량(不確實量)은 우리의 실정(實情)을 고려(考慮)한 적절(適切)한 값을 선택(選擇)하여 신뢰성(信賴性) 해석(解析) 및 설계규준(設計規準)을 산정(算定)했다. 현행(現行) WSD와 USD 설계법(設計法)의 신뢰성(信賴性) 수준(水準)을 분석(分析)하고 외국(外國)의 경우와 비교(比較) 검토(檢討)함으로써, 우리 나라에 알맞는 목표신뢰성지수(目標信賴性指數) ${\beta}_0=4.0$을 택(擇)하여 LRFD 설계규준(設計規準)에 의(依)한 저항(抵抗)-하중계수(荷重係數)를 제안(提案)했다. 또한 철근(鐵筋)과 콘크리트의 허용응력(許容應力)을 산정제안(算定提案)했다. 본(本) 연구(硏究)에서 제안(提案)한 신뢰성(信賴性)을 설계규준(設計規準) 및 허용응력(許容應力)은 일정(一定)한 신뢰성(信賴性)을 주는 보다 합리적(合理的)인 설계(設計)가 되게 하므로 현행(現行) R.C. 기둥의 설계규준(設計規準)에 신뢰성(信賴性) 설계(設計) 개념(槪念)을 하는 것이 바람직하다고 본다.

  • PDF

높은 아치형 지중강판 구조물의 시공 중 거동 분석 (Behaviors of the High-profile Arch Soil-steel Structure During Construction)

  • 이종구;조성민;김경석;김명모
    • 한국지반공학회논문집
    • /
    • 제19권6호
    • /
    • pp.71-84
    • /
    • 2003
  • 지중강판 구조물은 강판부재 내에 발생하는 휨모멘트에는 매우 취약하기 때문에 그 주변을 양질의 흙으로 뒷채움하여 주변 흙과의 상호작용에 의하여 상부에 작용하는 하중을 지지한다. 그러나, 구조물 측면을 뒷채움할 때나 최소토피고를 확보하지 못한 상태에서 활하중이 작용할 때에는 강판부재내에 과도한 모멘트가 발생할 수 있다. 현재 설계기준에서는 허용변형량을 제시하여 시공 중에 과도한 변형이 발생하는 것을 방지하고 있으며 Duncan(1979)과 McGrath 등(2001)은 강도해석법을 제안하여 시공 중에 발생하는 모멘트를 강판의 소성강도 이내로 제한하고 있지만, 허용변형량은 경험적으로 규정한 값이고 강도해석에 의한 구조 안정성 검토는 유한요소 해석결과를 바탕으로 제안되었기 때문에 이들에 대하여 실험적 검증이 필요하다. 이 연구에서는 높은 아치형 구조물에 대한 실규모 현장시험을 실시하여 시공 중 거동과 활하중에 대한 하중지지 거동을 분석하였다. 시험결과를 바탕으로 시험시공 구조물의 허용변형량을 '높이의 1.45%' 로 추정할 수 있었는데 이는 설계기준의 허용값인 '높이의 2%' 보다 작은 값이었다. 또한, 계측결과를 Duncan과 McGrath 등이 제안한 강도해석결과와 비교하여 Duncan은 성토하중에 의한 모멘트는 과소평가하고 활하중 모멘트는 과대평가 하지만 McGrath 등은 두 값을 모두 실제와 근접하게 예측함을 알 수 있었다. 그러나, 두 방법에 의한 소성힌지에 대한 안전율은 실제 안전율과 잘 일치하여 두 방법 모두 시공 중에 작용하는 활하중에 대한 구조 안정성을 적절히 평가할 수 있음을 확인하였다.나 길항력(6.4 ㎜)은 남아있었다. 또한 분자량 10kDa 이하의 분획에서는 chitinase 활성은 없으나 길항력(5.2㎜)은 나타내었고, 80℃에서 열처리하여도 길항력(5.0mm)이 남아있어 효소 이외 다른 생리활성물질이 존재함을 확인하였다.rin, (+)-taxifolin 3-O--$\beta$-D-glucopyranoside, (+)-catechin 및 benzoic acid의 함량은 건조 및 처리 온도가 증가할 수록 감소하는 양상을 나타내었다.tier taste and the Doenjang with P. japonica Powder had the least sweet taste. In the flavor and overall Preference, the Doenjang with P. japonica powder was the lowestEX>로 측정되었고, 계사내 지붕의 표면 온도는 최고 $29^{\circ}C$가 측정되었다. 계사 내 표면 온도 및 닭의 표면 온도는 계사내 공기온도의 영향을 많이 받는 것으로 나타났다.ill in a good agreement with those predicted by Rohsenow's formula, which was based on nucleate boiling. For the condenser, the wall temperatures were practically uniform, and the measured values of condensation heat transfer coefficient were 1.7 times

나선(螺旋)기둥의 신뢰성(信賴性) 설계규준(設計規準)에 관한 연구(研究) (A Study on Reliability Based Design Criteria for Spiral R.C. Columns)

  • 조효남;민경주
    • 대한토목학회논문집
    • /
    • 제3권4호
    • /
    • pp.11-20
    • /
    • 1983
  • 본(本) 연구(硏究)는 나선(螺旋)기둥의 신뢰성(信賴性) 설계규준(設計規準)을 고찰(考察)하고, Ellingwood가 제안(提案)한 신뢰성(信賴性) 해석(解析)과 신뢰성(信賴性) 설계규준(設計規準) 산정(算定) 알고리즘으로부터 실용적(實用的)인 알고리즘을 유도(誘導)하였다. Cornell의 MFOSM 이론(理論)에 의해 나선(螺旋)기둥의 불확실량(不確實量) 산정(算定)알고리즘을 유도(誘導)하여 저항(抵抗)의 불확실량(不確實量)을 산정(算定)했으며, 하중(荷重)의 불확실량(不確實量)은 우리의 실정(實情)을 고려한 적절한 값을 택(擇)하여 신뢰성(信賴性) 해석(解析) 및 신뢰성(信賴性) 설계규준(設計規準)을 산정(算定)했다. 현행(現行) WSD와 USD 설계법(設計法)의 신뢰성(信賴性) 수준(水準)을 분석(分析)하고 외국(外國)의 경우와 비교(比較) 검토(檢討)함으로써, 우리 실정(實情)에 적당한 목표신뢰성지수(目標信賴性指數) ${\beta}_0=3.5$를 택(擇)하여 LRFD 설계규준(設計規準)에 의한 하중일저항계수(荷重一抵抗係數)를 제안(提案)했으며, 신뢰성설계(信賴性設計)와 비슷한 신뢰성(信賴性)을 갖는 WSD의 철근(鐵筋)과 콘크리트의 허용응력(許容應力)을 산정(算定) 제안(提案)했다. 본(本) 연구(硏究)에서 제안(提案)한 신뢰성(信賴性) 설계규준(設計規準) 및 허용응력(許容應力)은 일정(一定)한 신뢰성(信賴性)을 주는 보다 합리적(合理的)인 설계(設計)가 됨을 알 수 있었다.

  • PDF

Response modification factor of suspended zipper braced frames

  • Abdollahzadeh, Gholamreza;Abbasi, Mehdi
    • Steel and Composite Structures
    • /
    • 제18권1호
    • /
    • pp.165-185
    • /
    • 2015
  • The suspended zipper bracing system is suggested to reduce the flaws of ordinary zipper braced and concentric inverted V braced frames. In the design procedure of suspended zipper bracing systems, columns and top story truss elements are strengthened. This bracing system show different performances and characteristics compared with inverted V braced and ordinary zipper frames. As a result, a different response modification factor for suspend zipper frames is needed. In this research paper, the response modification factor of suspended zipper frames was obtained using the incremental dynamic analysis. Suspended zipper braced frames with different stories and bay lengths were selected to be representations of the design space. To analyze the frames, a number of models were constructed and calibrated using experimental data. These archetype models were subjected to 44 earthquake records of the FEMA-P695 project data set. The incremental dynamic analysis and elastic dynamic analysis were carried out to determine the yield base shear value and elastic base shear value of archetype models using the OpenSEES software. The seismic response modification factor for each frame was calculated separately and the values of 9.5 and 13.6 were recommended for ultimate limit state and allowable stress design methods, respectively.

셀 입구 예열방법에 따른 가압형 고체산화물 연료전지/가스터빈 하이브리드 시스템의 성능 비교 해석 (Comparative Performance Analysis of Pressurized Solid Oxide Fuel Cell / Gas Turbine Hybrid Systems Considering Different Cell Inlet Preheating Methods)

  • 양원준;김재환;김동섭
    • 대한기계학회논문집B
    • /
    • 제29권6호
    • /
    • pp.722-729
    • /
    • 2005
  • Design analysis of the solid oxide fuel cell and gas turbine combined power system is performed considering different methods for preheating cell inlet air. The purpose of air preheating is to keep the temperature difference between cell inlet and outlet within a practical design range thus to reduce thermal stress inside the cell. Three different methods considered are (1) adopting a burner in front of the cell, (2) adopting a preheater (heat transfer from the main combustor) in front of the cell and (3) using recirculation of the cathode exit gas. For each configuration, analyses are carried out for two values of allowable maximum cell temperature difference. Performance characteristics of all cases are compared and design limitations are discussed. Relaxation of the cell temperature difference (larger difference) is proved to ensure higher efficiency. Recirculation of the cathode exit gas exhibits better performance than other methods and this advantage becomes more prominent as the constraint of the cell temperature difference becomes more severe (smaller temperature difference).

정지궤도 통신위성의 원격측정명령처리기 기술모델 열해석 (Thermal Analysis on the Engineering Model of Command and Telemetry Unit for a Geostationary Communications Satellite)

  • 김정훈;구자춘
    • 한국항공우주학회지
    • /
    • 제32권9호
    • /
    • pp.114-121
    • /
    • 2004
  • 정지궤도 통신위성 원격측정명령처리기의 기술인증모델 개발을 위하여 기술모델의 열 설계변경 및 해석을 수행하였다. 보드레벨의 소모전력량 측정치와 열주기시험의 결과를 활용하여 기술모텔에 대한 열해석모델을 개발하였다. 발열소자의 열소산 모델링은 인쇄회로기판에 투영된 소자의 footprint를 생성하고 그 표면의 전 영역에 균일하게 열소산량을 가하였다. 열설계변경(안)에 따라 설계변경 후 기술인증수준의 열진공환경에서 소자온도를 예측한 결과, CTU의 모든 소자들의 접합온도는 허용온도 이내로 존재하였다.

Determination of minimum depth of prestressed concrete I-Girder bridge for different design truck

  • Atmaca, Barbaros
    • Computers and Concrete
    • /
    • 제24권4호
    • /
    • pp.303-311
    • /
    • 2019
  • The depth of superstructure is the summation of the height of girders and the thickness of the deck floor. In this study, it is aim to determine the maximum span length of girders and minimum depth of the superstructure of prestressed concrete I-girder bridge. For this purpose the superstructure of the bridge with the width of 10m and the thickness of the deck floor of 0.175m, which the girders length was changed by two meter increments between 15m and 35m, was taken into account. Twelve different girders with heights of 60, 75, 90, 100, 110, 120, 130, 140, 150, 160, 170 and 180 cm, which are frequently used in Turkey, were chosen as girder type. The analyses of the superstructure of prestressed concrete I girder bridge was conducted with I-CAD software. In the analyses AASHTO LRFD (2012) conditions were taken into account a great extent. The dead loads of the structural and non-structural elements forming the bridge superstructure, prestressing force, standard truck load, equivalent lane load and pedestrian load were taken into consideration. HL93, design truck of AASHTO and also H30S24 design truck of Turkish Code were selected as vehicular live load. The allowable concrete stress limit, the number of prestressed strands, the number of debonded strands and the deflection parameters obtained from analyses were compared with the limit values found in AASHTO LRFD (2012) to determine the suitability of the girders. At the end of the study maximum span length of girders and equation using for calculation for minimum depth of the superstructure of prestressed concrete I-girder bridge were proposed.

자전거 짐받이에 대한 구조적 내구성 해석 (Structure Structural Durability Analysis on Bike Carrier Basket)

  • 조재웅;한문식
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.70-76
    • /
    • 2013
  • This study investigates structural durability through the analyses of stress, fatigue life and vibration damage at bike carrier basket. As model 2 has less stress and deformation than model 1 on static structural analysis, model 2 becomes more durable than model 1. Among the cases of nonuniform fatigue loads, 'SAE bracket history' with the severest change of load becomes most unstable but 'Sample history' becomes most stable. The amplitude deformations become highest at maximum response frequency of 2400Hz in cases of models 1 and 2. As the values of maximum equivalent stresses become within the allowable material stresses at two holes at the upper parts on models 1 and 2, these models become safe. The structural result of this study can be effectively utilized with the design of bike carrier basket by investigating prevention and durability against fatigue or vibration damage.