• 제목/요약/키워드: Allowable capacity

검색결과 317건 처리시간 0.024초

화학 플랜트에서의 비상발전기 용량선정 방안(PG3)에 관한 연구 (Study on Emergency Generator Capacity Selection(PG3) in the Chemical Plant)

  • 이승재;조만영;김세용;김은태;강병욱;박한민;김재철
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.55-60
    • /
    • 2015
  • PG and RG methods are widely known method for calculating the capacity of the emergency generator in construction electrical installation. PG and RG methods are mainly used as a saving a life, fire protection, fire fighting in construction. Because no long distance between the emergency generator and electric motor feeder, the relatively small motor power in construction electrical installation, the capacity of generator in PG and RG methods are little problem of voltage and reactive power of generator. However in many cases the application of the PG and RG method is difficult in the Chemical Plant because it is long distance between the generator and the motor Feeder and motor capacity is very large. Motor starting power factor is about 0.2 lagging power factor and motor starting current is about 6times during motor staring. Also Most of the staring current component is a reactive power component. therefore, it is many cases that lack of reactive power and excess of allowable voltage drop limit and After selection of emergency diesel generator, problems happen during motor starting. Therefore, to be selection of effective emergency generator, active generator power, reactive power and the required reactive power during large motor starting should be considered in chemical plant. It is also required of the verification process through simulation because hand calculation is very difficult considering study cases.

중앙분리대 대기공간이 있는 비신호 횡단보도에서의 보행자 횡단용량 모형식 개발 (A Study on Model Development of Pedestrian Crossing Capacity at Unsignalized Crosswalks with Pedestrian Refuge Area)

  • 김상구
    • 대한교통학회지
    • /
    • 제21권4호
    • /
    • pp.103-111
    • /
    • 2003
  • 본 연구는 보행자가 반대방향 도로횡단을 위한 간격을 찾기 위해 대피해 있을 수 있는 중앙분리대 대기공간이 설치되어 있는 비신호 횡단보도에서 확률적 모형을 토대로 보행자 횡단용량모형식을 개발하는 것을 목적으로 한다. 횡단보도에 접근하는 교통류의 차두시간 분포를 Erlang분포로 가정하고 간격수락이론을 이용하여 보행자 최대 통과교통량을 산출할 수 있는 방법론을 개발하였다. 분석 대상도로의 차로수는 왕복 2, 4, 6차로를 기준으로 Erlang 계수가 1, 2, 3인 분포를 사용하여 각 Erlang 계수별 모형식을 개발하였다. 모형식에 의한 보행자 용량은 접근교통량이 증가할수록 횡단가능 보행자수는 감소하고, 차로수가 커질수록 보행자용량은 감소하는 결과를 보였다. Erlang 계수는 교통량 수준과 밀접한 관계를 가지고 있으므로 보행자용량은 Erlang 계수값이 커질수록 감소하는 패턴을 나타냈다. 본 연구의 결과는 횡단보도의 보행자신호등 설치기준 및 보행자 대기공간을 제공해주는 기준으로 활용될 수 있을 것으로 판단되고, 특히 로타리교차로같이 차량중심의 연속성 진행흐름의 도로시설에서 보행자 안전시설의 설치기준으로 유용하게 사용될 수 있을 것이다.

순환자원 활용 지반안정재의 건축물 얕은기초 보강 적용사례 연구 (Study on application case of reinforce building shallow foundation for soil stabilized materials using circulating resources)

  • 송상훤
    • 문화기술의 융합
    • /
    • 제8권3호
    • /
    • pp.457-462
    • /
    • 2022
  • 본 연구는 순환자원을 대량 활용한 지반안정재를 활용하여, 비교적 작은 하중이 작용하는 중·저층 건축물의 얕은 기초 보강공법에 적용한 사례에 대한 내용으로 우선하여 현장 최적배합비를 도출하고자 4가지 혼합비에 대한 실내배합시험을 실시하였으며, 도출된 최적배합비를 이용하여 현장에서 건축물 얕은기초로 적용하였다. 현장 적용방법은 원지반와 지반안정재를 교반한 혼합토를 현장에서 혼합하여 다짐을 실시하는 매우 단순한 공정을 이용하였다. 현장 적용 후 평판재하시험을 원지반 1곳, 개량지반 2곳에 실시하여 허용지지력을 확인하였다. 지지력 확인 결과 충분한 지지력을 발휘하는 것으로 나타나, 해당 건축물의 앝은기초로 활용이 가능한 것으로 확인되었다.

다지점 진동대를 이용한 원자력발전소 배관계통의 내진성능실험 (Seismic Capacity Test of Nuclear Piping System using Multi-platform Shake Table)

  • 정진환;계만수;서영득;최형석;김민규
    • 한국지진공학회논문집
    • /
    • 제17권1호
    • /
    • pp.21-31
    • /
    • 2013
  • In this study, dynamic characteristics and seismic capacity of the nuclear power plant piping system are evaluated by model test results using multi-platform shake table. The model is 21.2 m long and consists of straight pipes, elbows, and reducers. The stainless steel pipe diameters are 60.3 mm (2 in.) and 88.9 mm (3 in.) and the system was assembled in accordance with ASME code criteria. The dynamic characteristics such as natural frequency, damping and acceleration responses of the piping system were estimated using the measured acceleration, displacement and strain data. The natural frequencies of the specimen were not changed significantly before and after the testing and the failure and leakage of the piping system was not observed until the final excitation. The damping ratio was estimated in the range of 3.13 ~ 4.98 % and it is found that the allowable stress(345 MPa) according to ASME criteria is 2.5 times larger than the measured maximum stress (138 MPa) of the piping system even under the maximum excitation level of this test.

토사적체에 따른 우수관의 허용용량 및 안전도 해석 (Analysis of safety and allowable capacity of storm sewer according to debris accumulation)

  • 권혁재
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2011년도 학술발표회
    • /
    • pp.249-249
    • /
    • 2011
  • 본 연구에서 AFDA(Approximate Full Distribution Approach)를 사용하여 하수관의 성능불능확률(Probability of capacity failure)을 정량적으로 산정할 수 있는 신뢰성 모형이 개발되었다. 전국 여러 도시의 연 최대강우강도(Yearly Maximum Rainfall Intensity)를 이용하여 그 확률분포함수를 규명하였고 우수관(Storm sewer)의 성능불능확률 산정을 위한 신뢰성모형에 적용하였다. 본 연구에서는 우수관의 성능불능확률을 산정하여 신뢰성 해석을 수행하였다. 먼저 적용도시의 강우자료를 면밀히 분석하고 연 최대강우강도의 통계적 특성을 분석하여 신뢰함수를 구축하였으며 우수관의 성능불능확률 산정을 위한 신뢰성 모형이 개발되었다. 그리고 우수관에 적체되는 토사의 깊이에 따라 우수관의 용량을 산정하였다. 재현기간별 강우강도를 사용하여 청주와 춘천의 원형우수관의 성능불능확률을 산정한 결과, 재현기간의 증가에 따란 성능불능확률을 급하게 상승하는 것을 알 수 있었다. 5년, 10년, 20년 재현기간에 따른 연 최대강우강도를 사용하여 청주와 춘천의 우수관의 성능불능확률을 산정하였다. 또한 토사의 적체에 따른 우수관 유효면적의 변화를 고려하여 두 도시의 우수관의 성능불능확률을 산정하였다. 원형 우수관의 성능불능확률을 산정한 결과, 토사의 적체에 따라 우수관의 용량은 감소하여 성능불능확률이 크게 증가하는 것을 확인 할 수 있었다. 따라서 우수관의 용량 감소를 막고 성능불능확률을 최소화하기 위해 우수관에 적체된 토사의 양을 예측할 수 있는 연구가 필요하며 적체된 토사와 콘크리트나 강관벽면이 복합된 우수관에 대한 조도계수를 보다 더 정확히 정량화 할 수 있는 연구가 수행되어야 할 것이다.

  • PDF

Power Cable Ampacity and Influential Factors Analysis under Operation

  • Tong, Qiang;Qi, Jianping;Wang, Yanling;Liang, Likai;Meng, Xiangxing;Zhang, Qiang
    • Journal of Information Processing Systems
    • /
    • 제14권5호
    • /
    • pp.1136-1149
    • /
    • 2018
  • With the increasing of urban electricity demand, making the most use of the power cable carrying capacity has become an important task in power grid system. Contrary to the rated ampacity obtained under extremely conservative conditions, this paper presents the various steady value of cable ampacity by using the changing surrounding parameters under operation, which is based on cable ampacity calculation equation under the IEC-60287 standard. To some degree, the cable ampacity analysis of actual surroundings improves the transmission capacity of cables. This paper reveals the factors that influence cable ampacity such as insulating layer thickness, allowable long-term conductor temperature, the ambient temperature, soil thermal resistance coefficient, and so on, then gives the class of the influence of these parameters on the ampacity, which plays a great role in accurately calculating the real-time ampacity and improving the utilization rate of cable in the complex external environment condition. Furthermore, the transient thermal rating of the cable is analyzed in this paper, and temperature variation of the conductor under different overload conditions is discussed, which provides effective information for the operation and control of the system.

Radiological safety assessment of lead shielded spent resin treatment facility with the treatment capacity of 1 ton/day

  • Byun, Jaehoon;Choi, Woo Nyun;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.273-281
    • /
    • 2021
  • The radiological safety of the spent resin treatment facility with a14C treatment capacity of 1 ton/day was evaluated in terms of the external and internal exposure of worker according to operation scenario. In terms of external dose, the annual dose for close work for 1 h/day at a distance of more than 1 m (19.8 mSv) satisfied the annual dose limit. For 8 h of close work per day, the annual dose exceeded the dose limit. For remote work of 2000 h/year, the annual dose was 14.4 mSv. Lead shielding was considered to reduce exposure dose, and the highest annual dose during close work for 1 h/day corresponded to 6.75 mSv. For close work of 2000 h/year and lead thickness exceeding 1.5 cm, the highest value of annual dose was derived as 13.2 mSv. In terms of internal exposure, the initial year dose was estimated to be 1.14E+03 mSv when conservatively 100% of the nuclides were assumed to leak. The allowable outflow rate was derived as 7.77E-02% and 2.00E-01% for the average limit of 20 mSv and the maximum limit of 50 mSv, respectively, where the annual replacement of the worker was required for 50 mSv.

매입말뚝의 설계식 적정성 및 지지력 상향 가능성 분석 연구 (Analytical Study on the Appropriateness of Design Formula and Possibility of Improving Bearing Capacity of Bored Pile)

  • 박종배;이범식;박용부
    • 토지주택연구
    • /
    • 제6권3호
    • /
    • pp.139-145
    • /
    • 2015
  • 말뚝 설계효율(설계지지력/재료강도)을 70%(160톤)에서 80%(190톤)로 개선하기 위해 기존 말뚝재하시험 자료 분석과 정밀 동재하시험 및 국내 최초의 양방향 재하시험을 실시하였다. 기존 동재하시험 데이터를 Davisson 방법으로 분석하면 풍화암 지지층(N치 50/15)에서도 설계지지력 190톤을 만족하였다. 그러나, 이를 CAPWAP으로 해석하면, 타격 에너지 부족으로 목표지지력을 만족하지 못한 말뚝이 전체의 40%가 나타났다. 따라서, 동재하시험 결과에서 목표 지지력을 확인하기 위해서는 6톤 이상의 해머에 의하여 충분한 타격력을 가하는 것이 필수적인 것으로 나타났다. 정적인 양방향 재하시험의 Davisson 분석에 의한 허용지지력은 260.0~335tonf(평균 285.3tonf)를 나타내어 목표지지력을 크게 상회하는 것으로 나타났다. 이 시험결과는 동일 말뚝에 대한 정밀 동재하시험의 허용지지력(평균 202.3tonf) 보다 약 40% 정도 크게 나타났는데, 동재하시험에서 충분하지 않은 타격력, 정적 양방향재하시험 시 주변말뚝에 의한 인터록킹에 의한 지지력 증가 등에 의한 차이로 판단된다.

고화처리공법이 적용된 연약점토지반의 침하 및 지지력 개선에 관한 사례연구 (A case Study on Settlement and Bearing Capacity Improvement for Soft Clay Applying the Reinforcement Method using Stabilized Soil)

  • 기완서;김선학
    • 한국산학기술학회논문지
    • /
    • 제15권6호
    • /
    • pp.3923-3930
    • /
    • 2014
  • 본 연구에서는 광양 ${\bigcirc}{\bigcirc}$산업단지 공사현장내의 도로 및 구조물 시공구간 중 연구대상 3구간을 선정하여 지반의 물리 역학적 특성을 분석하고 구조물 시공조건, 고화처리 단면조건에 따라 Midas-GTS를 통해 압밀해석과 지지력 산정을 수행하였다. 도로 및 구조물이 시공되는 연약점토지반의 침하 및 지지력 개선방안으로 고화처리공법 적용 시 지반의 안정성 개선효과와 고화처리단면에 따른 침하 및 지지력 개선효과를 분석하였다. 연약점토지반에 고화처리공법을 적용 시 침하 및 지지력 개선효과가 뛰어난 것으로 나타났으며 특히, 고화처리공법 적용 후 압밀침하량이 최소 53%에서 최대 82%까지 감소하여 압밀침하 억제효과가 우수한 것으로 나타났다. 고화처리 폭이 설치 구조물 폭의 2배 이상인 경우 고화처리 폭이 증가하여도 압밀침하 억제효과는 1~7%정도로 미소한 것으로 나타났다. 또한, 고화처리 폭 6m, 심도 1m이상 적용시 고화처리 전보다 허용지지력이 2.3~3.3배정도 크게 증가한 것으로 나타나 고화처리공법을 적용하면 지지력 증대효과가 매우 우수함을 알 수 있었다.

비선형 FEM 해석에 기초한 PSC I 거더교량의 내하력 평가기법에 관한 연구 (Study on the Evaluation Method of Load Carrying Capacity Based on Nonlinear FEM Analysis for PSC I Typed Girder Bridge)

  • 심종성;김규선;문도영;주민관
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.81-88
    • /
    • 2008
  • 기존 USD 평가법은 단순지지 PSC I형 거더교량의 프리스트레싱 상향력을 간과함에 따라 내하력을 보수적으로 평가할 수 밖에 없는 것으로 판단된다. 본 연구에서는 프리스트레싱 상향력 효과가 적용된 수정 강도설계법(MUSD)이 제안되었으며, 동일 대상교량에 대해 적용하여 기존 내하력 평가법과 비교분석하였다. 또한 활하중 계수를 이용한 비선형 FRM 해석에 의한 내하율 평가방법이 새로 제안되어 기존 실험 및 해석적인 연구와의 비교를 통해 단순지지 PSC I형 거더교량에 적용가능한 합리적인 내하력 평가방법을 제시하였다. 평가결과, 본 연구에서 제안한 MUSD 내하력 평가법은 기존 USD 평가법에 비해 단순지지 PCS I형 거더교량의 내하율을 합리적으로 평가할 수 있는 것으로 분석되었으며, 특히 비선형 유한요소 해석법에 의한 내하력 평가법은 PSC 교량구조물의 전반적인 구조거동 분석과 함께 해당 교량구조물의 내하력을 다각도로 평가할 수 있는 것으로 확인되었다.