• Title/Summary/Keyword: Allowable Stress Design

Search Result 349, Processing Time 0.025 seconds

Structural Optimization for Small Scale Vertical-Axis Wind Turbine Blade using Response Surface Method (반응표면법을 이용한 소형 수직축 풍력터빈 블레이드의 구조 최적화)

  • Choi, Chan-Woong;Jin, Ji-Won;Kang, Ki-Weon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.4
    • /
    • pp.22-27
    • /
    • 2013
  • The purpose of this paper is to perform the structural design of the small scale vertical-axis wind turbine (VAWT) blade using a response surface method(RSM). First, the four design factors that have a strong influence on the structural response of blade were selected. Analysis conditions were calculated by using the central composite design(CCD), which is a typical design of experiment for the response surface method(RSM). Also, the significance of the central composite design(CCD) was verified using analysis of variance(ANOVA). The finite element analysis was performed for the selected analytical conditions for the application of response surface method(RSM). Finally, a optimization problem was solved with a objective function of blade weight and a constraint of allowable stress to achieve a optimal structural design of blade.

The study on the system reliability and code conversion for the probability based design (확률 기반 설계법을 위한 코드 변환과 시스템 신뢰도에 대한 고찰)

  • Kim, Gwang-Chul
    • Journal of the Korea Furniture Society
    • /
    • v.20 no.5
    • /
    • pp.440-456
    • /
    • 2009
  • Because PBD was started as a design tool for steel construction and concrete construction, it was able to applied to the post and beam method of wooden building constructions. But, it may not suitable to light frame wooden construction that is becoming popular in domestic construction market due to the economical efficiency and the constructive simplification. Owing to the share effects between member and sheathing material or among structural members, light frame wooden construction is different from post and beam construction that use a single structural member. Therefore, consideration on the system analysis and system design are urgently needed to use in actual life and inspect the reliability of structures from the system view. With this in mind, code conversion from ASD to PBD that is pressing issue in domestic wooden building construction was studied, also various countries status about PBD were considered and then approaching methods on the system reliability were referred. Finally, several considerations for the development of PBD were explored. PBD should be considered as, not only a new structural design process that select sizes of structural member, but a industrial tool that can lead a development of more reliable wood products. A strongest point of PBD is independent of various construction materials and construction types.

  • PDF

A Structural Analysis and Optimization of a 60 N.m Class Flexible Disk Coupling (60 N.m급 플렉서블 디스크 커플링 구조해석 및 최적화)

  • Lee, H.K.;Kim, B.R.;Kim, S.M.;Kim, J.B.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.5
    • /
    • pp.774-781
    • /
    • 2013
  • A structural analysis was carried out for a 60 N.m class flexible disk coupling. Flexible disk couplings are used to transmit power between two shafts. When a flexible coupling is used, some amount of misalignments such as angle of deviation and end play can be allowed in assembling the shafts. However, the maximum allowable misalignment should be decided to guarantee the fatigue life. In this study, the effect of the angle of deviation and end play on the maximum stress was investigated. From the analysis results, it was shown that the angle of deviation has a greater effect on the maximum stress than the end play. Furthermore, the dimensions of the disk plate were optimized to realize a better design. From the optimization, the maximum stress could be reduced by up to 5.2%.

Optimal dimensioning for the corner combined footings

  • Lopez-Chavarria, Sandra;Luevanos-Rojas, Arnulfo;Medina-Elizondo, Manuel
    • Advances in Computational Design
    • /
    • v.2 no.2
    • /
    • pp.169-183
    • /
    • 2017
  • This paper shows optimal dimensioning for the corner combined footings to obtain the most economical contact surface on the soil (optimal area), due to an axial load, moment around of the axis "X" and moment around of the axis "Y" applied to each column. The proposed model considers soil real pressure, i.e., the pressure varies linearly. The classical model is developed by trial and error, i.e., a dimension is proposed, and after, using the equation of the biaxial bending is obtained the stress acting on each vertex of the corner combined footing, which must meet the conditions following: 1) Minimum stress should be equal or greater than zero, because the soil is not withstand tensile. 2) Maximum stress must be equal or less than the allowable capacity that can be capable of withstand the soil. Numerical examples are presented to illustrate the validity of the optimization techniques to obtain the minimum area of corner combined footings under an axial load and moments in two directions applied to each column.

Mathematical model for assessment of the safety of over three-span steel beams based on average strains from long gage optic sensor (평균변형률을 이용한 3경간 이상 연속 철골보의 안전성 평가 기법)

  • Jung Seong-Moon;Lee Hong-Min;Park Hyo-Seon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.159-166
    • /
    • 2006
  • Although the strain distribution along the length of a beam in buildings or infrastructures is non-uniform, most fiber optic sensors are point sensors that can measure the strain only at a local point of a beam. Long gage fiber optic sensors that measure integrated strain over a relatively long length can consider strain variation. This type of sensor was found to be efficient and useful for monitoring large-scale structures. On the other hand, the maximum strain or stress in a beam can not be measured with long gage optic sensors. However, for the assessment of the safety of multi-span steel beams subjected to various vertical loads, the maximum strain or stress measured during monitoring is required for comparison with the allowable stress of the beam calculated by a design code. Therefore, in this paper, mathematical models are presented for determination of the maximum values of strains in more three-span steel beams based on the average strains measured by long gage optic sensors.

  • PDF

A Structural Analysis of Tsunami-proof Damper in Nuclear Power Plant (원자력 발전소에서 쓰나미 방지용 댐퍼에 대한 구조해석)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.603-609
    • /
    • 2020
  • The purpose of this study is to research dampers, which are applied mainly to buildings adjacent to the coast, such as nuclear facilities, and used for ventilation and can safely protect lives and equipment in emergency situations. Comparing the equivalent stress for three models with hinge reinforcement and support reinforcement based on the early design model for Damper, in the Base model, the highest stress occurred in the part of hinge, especially in the centrally mounted hinge, and after reinforced the hinge, it was occurred in the rear support. For models reinforced hinges and supports, it is considered that reinforcement for stiffness will be required in the future as it entered within the range of allowable stress. For the safety factor distribution, the minimum safety ratio was sufficiently secured at least 1 and was high at the edge of the Damper frame and the Blade. As the hinge was reinforced, the safety factor distribution of Blade was increased, and it was verified that the safety factor was secured through the support reinforcement.

Shape Design Optimization of Fluid-Structure Interaction Problems (유체-구조 연성 문제의 형상 최적설계)

  • Ha, Yoon-Do;Kim, Min-Geun;Cho, Hyun-Gyu;Cho, Seon-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.44 no.2 s.152
    • /
    • pp.130-138
    • /
    • 2007
  • A coupled variational equation for fluid-structure interaction (FSI) problems is derived from a steady state Navier-Stokes equation for incompressible Newtonian fluid and an equilibrium equation for geometrically nonlinear structures. For a fully coupled FSI formulation, between fluid and structures, a traction continuity condition is considered at interfaces where a no-slip condition is imposed. Under total Lagrange formulation in the structural domain, finite rotations are well described by using the second Piola-Kirchhoff stress and Green-Lagrange strain tensors. An adjoint shape design sensitivity analysis (DSA) method based on material derivative approach is applied to the FSI problem to develop a shape design optimization method. Demonstrating some numerical examples, the accuracy and efficiency of the developed DSA method is verified in comparison with finite difference sensitivity. Also, for the FSI problems, a shape design optimization is performed to obtain a maximal stiffness structure satisfying an allowable volume constraint.

A Case Study on the Design of Drilled Shaft on Soft Ground in Vietnam (베트남 연약지반에서의 현장타설말뚝 설계 사례)

  • Seo, Won-Seok;Cho, Sung-Han;Choi, Ki-Byung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.591-604
    • /
    • 2008
  • In this study, two design examples of drilled shafts on soft ground in Ho-Chi-Minh City, Vietnam are introduced. One is for a 27-story apartment and the other is for a Arch bridge over Saigon river. Unlikely the normal cases in Korea, all of the bored pile foundations are supposed to be placed on soil layers. Therefore, skin friction between pile and ground is the most crucial design parameter. Three methods using SPT N value of sandy soil -Korean Road Bridge Code(1996), Reese and Wright (1977), and O'Neill and Reese (1988)- were adopted to obtain an ultimate axial bearing capacity. In order to verify the calculated bearing capacity, 3 sets of static load test and a Osterberg Cell test were performed at an apartment site and a bridge site respectively. LRFD (Load Resistance Factored Design) method was compared with ASD (Allowable Stress Design) method. On application of ASD method, safety factor for skin friction was adopted as 2 or 3 while safety factor for end bearing was 3. The design bearing capacities from ASD method matched well with those from LRFD method when safety factor for skin friction was adopted as 2.

  • PDF

Optimal Design for Minimizing Weight of Housing of Hydraulic Breaker (유압 브레이커의 중량 감소를 위한 하우징 최적설계)

  • Park, Gyu-Byung;Park, Chang-Hyun;Park, Yong-Shik;Choi, Dong-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.2
    • /
    • pp.207-212
    • /
    • 2011
  • A hydraulic breaker is an attachment installed at the end of excavator arm and is used for breaking. As per the authors' knowledge, there have been no research results on reducing the weight of the hydraulic breaker even though this weight reduction is very important for improving the performance of the excavator. In this study, we minimize the weight of the housing of the hydraulic breaker under normal operating conditions, while the maximum stress of the housing is lower than the allowable stress. A meta-model, which is generated by using the CAE results for the sampling design points determined by an orthogonal array, is used to solve the minimization problem. The weight of the housing according to the optimal design is found to be lower than the original weight by 4.8% while satisfying the constraint on the maximum stress.

A Study on the Performance Improvement of High-Pylon Extradosed Bridge adopting Fatigue Loading Condition (국내 설계하중의 피로특성을 적용한 고주탑 엑스트라도즈드교의 성능개선에 관한 연구)

  • Lee, Young Jin;Shin, Seung Kyo;Lim, Yun Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2A
    • /
    • pp.137-148
    • /
    • 2010
  • This study proposes the optimal ratio of vertical load-carrying capacity (${\beta}$) by investigating structural performances and economic efficiency in the extradosed bridges. Without design standards for the extradosed bridge, Japanese design standards have been used domestically. For the design live load, DL24 is found to be more adequate than DB24. Using the DL24 load, parameter studies are carried out. The parameters are 'main tower height', 'main girder stiffness', and 'cable arrangement'. As a result, it is found that one side cable-stayed extradosed bridges are more economical than double side cable-stayed extradosed bridges. This study also shows that when the ratio of vertical load-carrying capacity(${\beta}$) is 30~50% in the extradosed bridge with the ratio of tower height to main span length 1/6, the extradosed bridge is most economical because of the cable stress less than the allowable stress.