• Title/Summary/Keyword: Allowable Limit

Search Result 326, Processing Time 0.023 seconds

Evaluation of Traffic Congestion in Channels within Harbour Limit -On Channels in Ulsan New Port Development- (항계내 항로의 해상교통 혼잡도 평가에 관하여 - 울산 신항만의 혼잡도 평가를 기준으로 -)

  • Koo, J.Y.
    • Journal of Korean Port Research
    • /
    • v.11 no.2
    • /
    • pp.173-189
    • /
    • 1997
  • Whether over taking or parallel sailing of two or more vessels is allowable on marine traffic route or not, the traffic congestion due to traffic volume has to be evaluated separately. In Gaduk-sudo, overtaking or parallel sailing is so allowable that the Bumper Model is introduced to evaluated the traffic congestion. But the channels within the habour limit such as the route of Ulsan New Port are so prohibited overtaking or parallel sailing that the traffic congestion has to be evaluated by using theoretical traffic capacity or by traffic simulation. In this paper, the congestion of Southern New Port and Mipo Port was evaluated the congestion by using theoretical traffic capacity and the other area of Ulsan Port by traffic simulation. The incresed traffic volumes on Ulsan Channels according to Ulsan New Port Development in 2011 were evaluated to have no effect with the traffic congestion.

  • PDF

A Bioeconomic Analysis on the Evaluation of Alternative Management Policies in the Multispecies Fishery (복수어업에 있어서의 어업관리수단 평가를 위한 생물경제학적 연구 -미국 멕시코만의 red grouper와 yellowedge grouper 복수어업을 사례로-)

  • 김도훈
    • The Journal of Fisheries Business Administration
    • /
    • v.35 no.1
    • /
    • pp.1-22
    • /
    • 2004
  • Since the red grouper stock was initially declared to be overfished by the NMFS in September 2002, the Gulf of Mexico Fishery Management Council must prepare for the red grouper rebuilding plan considering the following alternative management policies: Total Allowable Catch(TAC), 5 - month season closure, 1800 - pound trip limit, and 50 - fathom longline boundary. The first concern the Council has is to evaluate the effects of recommended policies and the second is to analyze the impact of management policies on yellow edge grouper. This is because the fleets harvest red grouper also catch yellowedge grouper, the regulations on red grouper are likely to allow fishing effort to be distributed into yellowedge grouper. Therefore, this study is aimed at evaluating the biological and economic effects of management policies considering simultaneously the impact of red grouper regulations on yellow edge grouper by developing a combined red grouper and yellowedge grouper bioeconomic model. The overall results indicate that management policies for red grouper would adversely affect the yellowedge grouper stock if yellowedge grouper is not protected by its regulations. The TAC policy has the most serious impact on the yellowedge grouper stock, while the 1800 - pound trip limit policy minimizes the reduction in the yellowedge grouper stock. However, the target stock size of red grouper is achieved as well as the largest net present value of returns is gained in the TAC policy.

  • PDF

A Study on the Large-scale Adoption Method of Distribution System Interconnected with PV System by Energy Storage System (전기저장장치를 이용한 태양광전원이 연계된 배전계통 수용성향상 방안에 관한 연구)

  • Nam, Yang-Hyun;Choi, Sung-Sik;Kang, Min-Kwan;Lee, Hu-Dong;Park, Ji-Hyun;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1031-1039
    • /
    • 2018
  • If large-scale PV systems are continuously interconnected to distribution system, customer voltages could violate the allowable voltage limit($220{\pm}13V$) according to reverse power flow of PV system. In order to solve these problems, this paper proposes flexible adoption evaluation algorithm of PV system in distribution system which estimates proper introduction capacity and location of ESS(energy storage system) for keeping customer voltages within allowable voltage limit based on various operating scenarios related with connecting point and capacity of PV system. And also this paper proposes modeling of ESS, SVR(step voltage regulator) and PV system using PSCAD/EMTDC S/W and analyzes characteristics of customer voltages and the adoption ability of PV system in distribution system. From the simulation results, it is confirmed that proposed algorithm is useful for large-scale adoption of PV system in distribution system to maintain customer voltages within allowable voltage limit.

A Study on Fire and Evacuation of TrainingShip HANBADA using FDS (FDS를 이용한 실습선 한바다호 화재 및 피난 연구)

  • KIM, Won-Ouk
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.2
    • /
    • pp.380-385
    • /
    • 2017
  • Maritime accidents caused by a ship include collisions, sinking, stranding and fire etc. This study is intending to consider fire accidents among such diverse marine accidents. It is much likely that various sorts of fires break out because crews are living in a narrow space for long periods of time consequent on the ship's characteristic of sailing on the sea. This study carried out a simulation through the special program for fire analysis - FDS (Fire Dynamics Simulator) in order to find the effective evacuation time, i.e. life survival time. Particularly, this study did comparative analysis of the influence on the survival of cadets based on the collected simulation data by fire size and sort. As a result of the analysis, It was analyzed the Evacuation Allowable Limit Temperature $60^{\circ}C$ and resulted that there is no influence in evacuation by temperature. In case of visibility analysis, it reached to 5m which is the Evacuation Allowable Limit at 117 seconds under the condition of wood fire in 1MW. When there is Kerosene in 1MW, it took 92.4 seconds to reach by 5m which is the Evacuation Allowable Limit. Theoretical evacuation time for the non-tilted ship was 118.8 seconds in 1MW sized fire so it is shown that the most passengers are met the evacuation safety in case of wood fire. However, the majority of passengers could not be ensured the evacuation safety in Kerosene case.

Limit Analysis of the Distance between DU and RU in 4G FDD Mobile Communication Systems (FDD 방식의 4G 이동통신 기지국에서 DU와 RU간 한계거리 분석)

  • Kim, Sung-Man
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.1
    • /
    • pp.135-139
    • /
    • 2012
  • A majority of 4G Mobile communication manufacturers have launched separated-type base stations composed of DU (digital unit) and RU (ratio unit). DUs are usually installed in the central office, while RUs with antennas are installed on the top of building or pole. Therefore, the allowable distance between DU and RU is very important for cell planning. In this paper, we analyze the allowable distance between DU and RU induced by closed-loop MIMO (mulitple input multiple output) technology in 4G FDD (frequency division duplexing) mobile communication systems. In conclusion, the distance limit between DU and RU is dependent on the frequency of the wireless communication, and the allowable distance is about 11 km when assuming the operating frequency is 2 GHz.

A Study on the Coordination Control Algorithm of Step Voltage Regulator and Battery Energy Storage System for Voltage Regulation in Distribution System (배전계통의 전압안정화를 위한 선로전압조정장치와 전지전력저장장치의 협조제어 알고리즘에 관한 연구)

  • Kim, Byung-Ki;Wang, Jong-Yong;Park, Jea-Bum;Choi, Sung-Sik;Ryu, Kyung-Sang;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.269-278
    • /
    • 2016
  • In order to maintain customer voltages within allowable limit($220{\pm}13V$) as much as possible, tap operation strategy of SVR(Step Voltage Regulator) installed in distribution system is very important, considering the scheduled delay time(30 sec) of SVR. However, the compensation of BESS(Battery Energy Storage System) during the delay time of SVR is being required because the customer voltages in distribution system interconnected with PV(Photovoltaic) system have a difficultly to be kept within allowable limit. Therefore, this paper presents the optimal voltage stabilization method in distribution system by using coordination operation algorithm between BESS and SVR. It is confirmed that customer voltage in distribution system can be maintained within allowable limit($220{\pm}13V$).

Improvement of the Conductor Temperature Calculation Algorithm for Calculating the Allowable Current in the Underground Channel (지중관로에서의 실제 허용전류 산출을 위한 도체온도 계산 알고리즘 개선에 관한 연구)

  • Lee, Hyang-Beom;Lee, Byung-Chul;Kim, Jung-Hoon;Nam, Yong-Hyun;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.352-357
    • /
    • 2018
  • In this paper, the improvement of the conductor temperature calculation algorithm is studied. The allowable current of the underground transmission line is determined by the conductor temperature limit. Usually to calculate the allowable current limit, the conductor temperature is assumed in the most worst environment condition. It is possible to increase the transmission capacity if the actual burial environment is considered. Therefore, in this paper an algorithm is proposed to calculate the conductor temperature by distinguishing two area of a underground transmission line condition - the manhole where the temperature sensor can be installed and the underground transmission line in which the temperature sensor can not be installed easily. When calculating the conductor temperature by the underground line in the pipeline, the existing standard describes each environment as a single soil heat resistance and one ambient temperature. In order to compensate this situation, thermal resistance model that can take into consideration the ground surface temperature and under ground temperature is proposed. It is shown that the accuracy of the proposed model is increased compared with the existing standard calculation result.

Evaluation on Allowable Vehicle Speed Based on Safety of Track and Railway Bridge (궤도 및 교량 안전성을 고려한 열차 증속가능 속도대역 평가)

  • Bahng, Eun Young
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.145-151
    • /
    • 2018
  • In this study, the track-bridge interaction analysis was performed using an analytical model considering the track structure, thereby taking into account the linear conditions (R=650 m, cant variation $160{\pm}60mm$) and the dynamic characteristics of the bridge. As a result of the study, the allowable speed on the example bridge considered was calculated at 200 km/h based on vertical deflection, vertical acceleration, and irregularity in longitudinal level, but was also evaluated at 170km/h based on the coefficient of derailment, wheel load reduction, and lateral displacement of the rail head. It is considered desirable to set the speed 170km/h to the speed limit in order to secure the safety of both the bridge and the track. It is judged that there will be no problems with ensuring rail protection and train stability in the speed band.

Laser imager의 성능관리에 대한 연구

  • Lee, Hyeong-Jin;In, Gyeong-Hwan;Lee, Won-Hong;Kim, Geon-Jung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.3 no.1
    • /
    • pp.126-132
    • /
    • 1997
  • Purpose : To apply to Program of Auto processor quality control after comparison of Film density variations with amendments to Auto density by using Check density program and Adjust density program of calibration mode into the Laser imager. Methods : Observe Check and Adjust density variations on the Control chart with standard step and value during seven months from December, 1995 to June, 1956 extending twice a week. (1) Measure density value on the steps after printing out 17-step sensitometric pattern of the Check density program. (2) In the same way, measure density values after amending density by using Adjust density program If they are exceeding allowable error limit. Results : In case of Check density program, the exceeding limit rates of Density difference(DD) and Middle density(MD) are: FL-IM3543 DD=75%. MD=72.5%, FL-IMD DD=0%. MD=30.8%(14.5%) After amending density by using Adjust density program, the exceeding limit rates of all both Laser imager were zero percent. The standard deviations are show lower FL-IM D than FL-IM3543 on the Check density control chart, but higher on the Adjust density control chart. Conclusion : (1) Check density variations by printingout sensitometric pattern extending once a week at least for quality control of the Laser imager. (2) In case of a dusty place, check the Laser beam transmission after cleaning Laser optical unit extending once a month. (3) Be sure to measure and check density values by using adjust density program if they are exceeding allowable error limit. (4) Maintain much better film density by performing the adjust density program even if check density values are existed within normal limit.

  • PDF