• 제목/요약/키워드: Allowable Limit

검색결과 326건 처리시간 0.031초

진동 규제기준에 따른 인체의 허용 한계거리 예측 (The Prediction of Allowable Limit Distance about Human Body by Vibration Regulation)

  • 송정언;홍웅기;김승곤
    • 환경영향평가
    • /
    • 제21권2호
    • /
    • pp.289-296
    • /
    • 2012
  • The shock vibration such as machine vibration, blasting vibration etc. has effect on nearby structure as well as human body. The purpose of this study is to predict allowable limit distance of vibration about human body. First of all, vibration velocity such as PPV, PVS was measured by shock vibration experiment, and vibration level was calculated by conversion formula of vibration velocity. And then, allowable limit distance was analyzed by converted vibration level. The results are as follows : Firstly, the correlation coefficient of converted vibration level was over R=0.94, and vibration level caused by PVS was usually represented to high curve line. Secondly, the cross point of vibration level between ground and concrete condition was represented to 66.68dB(V), and allowable limit distance was represented to difference over three times when vibration regulation was raised from 65dB(V) to 80dB(V).

A Study on the Voltage Stabilization Method of Distribution System Using Battery Energy Storage System and Step Voltage Regulator

  • Kim, Byung-ki;Park, Jae-Beom;Choi, Sung-Sik;Jang, Moon-Seok;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.11-18
    • /
    • 2017
  • In order to maintain customer voltages within the allowable limit($220{\pm}13V$) as much as possible, tap operation strategy of SVR(Step Voltage Regulator) which is located in primary feeder, is widely used for voltage control in the utilities. However, SVR in nature has operation characteristic of the delay time ranging from 30 to 150 sec, and then the compensation of BESS (Battery Energy Storage System) during the delay time is being required because the customer voltages in distribution system may violate the allowable limit during the delay time of SVR. Furthermore, interconnection of PV(Photovoltaic) system could make a difficultly to keep customer voltage within the allowable limit. Therefore, this paper presents an optimal coordination operation algorithm between BESS and SVR based on a conventional LDC (Line Drop Compensation) method which is decided by stochastic approach. Through the modeling of SVR and BESS using the PSCAD/EMTDC, it is confirmed that customer voltages in distribution system can be maintained within the allowable limit.

화력 발전소 증기 터빈의 자동기동을 위한 주증기 제어 밸브 수명해석 (Service Life Analysis of Control Valve for Automatic Turbine Startup of Thermal Power Plant)

  • 김효진;강용호;신철규;박희성;유봉호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.7-12
    • /
    • 2000
  • The automatic turbine startup system provides turbine control based on thermal stress. During the startup, control system monitors and evaluates main components of turbine using damage mechanism and life assessment. In case of valve chest, the temperature of inner/outer wall is measured by thermo-couples and the safety of these values are evaluated by using allowable ${\Delta}T$ limit curve during the startup. Because allowable ${\Delta}T$ limit curve includes life assessment, it is possible to apply this curve to turbine control system. In this paper, low cycle fatigue damage and combined rupture and low cycle fatigue damage criterion proposed for yielding the allowable ${\Delta}T$ limit curve of CV(control valve) chest. To calculate low cycle fatigue damage, the stress analysis of valve chest has peformed using FEM. Automatic turbine startup to assure service life of CV was achieved using allowable ${\Delta}T$ limit curve.

  • PDF

화력 발전소 증기 터빈의 자동기동을 위한 주증기 제어 밸브 수명해석 (Service Life Analysis of Control Valve far Automatic Turbine Startup of Thermal Power Plant)

  • 김효진;강용호
    • 대한기계학회논문집A
    • /
    • 제26권1호
    • /
    • pp.1-6
    • /
    • 2002
  • The automatic turbine startup system provides turbine control based on thermal stress. During the startup, control system monitors and evaluates main components of turbine using damage mechanism and life assessment. In case of valve chest, the temperature of inner/outer wall is measured by thermo-couples and the safety of these values are evaluated by using allowable △T limit currie during the startup. Because allowable ΔT limit curve includes life assessment, it is possible to apply this curve to turbine control system. In this paper, low cycle fatigue damage, combined rupture and low cycle fatigue damage criterion were proposed for yielding the allowable ΔTf limit curve of CV(control valve) chest. To calculate low cycle fatigue damage, the stress analysis of valve chest has been performed using FEM. Automatic turbine startup to assure service life of CV was achieved using allowable ΔT limit curve.

부하변동에 따른 유도전동기 전류와 전력 특성 (Characteristics for Current and Power of Induction Motor by Load Variation)

  • 김종겸
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.82-87
    • /
    • 2011
  • Induction motor is most widely used as the driving power in the industrial site. Induction motor current is composed of two parts, magnetizing current and load current. Load current uses energy what is doing the work. Load current varies with load variance but magnetizing current is constant, regardless of load variation. Magnetizing current needs for establishing the rotating magnetic field of induction motor and lags behind the voltage. Generally capacitor is used for power-factor compensation of inductive load. Self-excitation occurs when the capacitive reactive current from the capacitor is greater than the magnetizing current of the induction motor. When this occurs, excessive voltages can result on the terminals of the motor. This excessive voltage can cause insulation degradation and ultimately result in motor insulation failure. In this paper, we analyzed that how the magnetizing current and condenser current is operating at the allowable limit by the load variation. Condenser current is below allowable limit of magnetizing current but magnetizing current is above allowable limit at the lower load operation condition.

판매자와 구매자의 재고상한이 존재하는 VMI (VMI with Upper Limit of Inventory for Vendor and Retailer)

  • 이동주
    • 산업경영시스템학회지
    • /
    • 제40권4호
    • /
    • pp.105-111
    • /
    • 2017
  • Vendor Managed Inventory is a well-known vendor-retailer coordination approach in supply chain management where the vendor manages inventory of the retailer and determines the order interval and order quantity for the retailer. To consider practical situation, the upper limit of inventory for the retailer is set. If the inventory level for the retailer exceeds the upper limit, then the penalty cost is charged to the retailer. Furthermore, maximum allowable inventory level is set for the vendor to prevent the vendor from keeping much inventory. Single-vendor multi-retailer supply chain model with upper limit of inventory for vendor and retailers is studied. All the retailers' are assumed to have the common cycle time, and a vendor manages retailers' inventory and replenishes products. The mathematical formulation is introduced to minimize the total cost including the penalty cost violating the upper limit of inventory for retailers with the constraint of maximum allowable inventory level. The solution procedure based on Karush-Kuhn-Tucker (KKT) conditions is derived. KKT conditions are often applied to find an optimal solution of nonlinear programming problem with constraints. An illustrative example is used to show the application of the proposed solution procedure. Furthermore, sensitivity analysis is done to find out the relationship between maximum allowable inventory level and other values such as order quantity, the number of shipment, vendor's cost, retailer's cost, and total cost. As maximum allowable inventory level decreases, the number of shipment decreases but total cost increases. Order quantity has the trend of decline and is affected by the number of shipment.

자기 베어링의 성능한계를 고려한 작동특성 연구 (Performance Study of Magnetic Bearing Considering the Performance Limit)

  • 장인배;한동철
    • 소음진동
    • /
    • 제5권1호
    • /
    • pp.59-65
    • /
    • 1995
  • In this study, we investigated the operational limit of magnetic bearing-rotor system due to the maximum force limit and slew rjate limit of the electromagnetic actuator as a function of the time dependent control characteristics. The feedback gain of the controller varies the current of the electromagnet coil with the motion of the rotor. The distorsion of magnetic force due to the slew rate limit is not occurred jup to 30, 000 rpm in the magnetic bearing that we have a close relation with the rotational speed and vibration level of the rotor and the proportional gain of the controller. Therefore the maximum force limit determines the maximum allowable orbit radius of the magnetic bearing-rotor system. The maximum allowable vibration levels are exponentially decreased according to the increment of rotational speed and proportional gain of the controller.

  • PDF

Current practices and future directions of steel design in Japan

  • Yamaguchi, Eiki
    • Steel and Composite Structures
    • /
    • 제5권2_3호
    • /
    • pp.159-168
    • /
    • 2005
  • Four design codes/regulations for steel structures in Japan are briefly reviewed. Some of them employ the limit state design concept while the others are still based on the allowable stress design concept. The process for revision is now in action. The directions in the development of structural design codes are also reported herein. It is noted that a current trend in this development is to employ the performance-based design concept that has been successfully implemented in some seismic design codes.

굵은 골재의 관한 연구 (A Study of Abrasion Rate of Coarse Aggregate)

  • 이동영;전현우
    • 한국농공학회지
    • /
    • 제12권3호
    • /
    • pp.2013-2018
    • /
    • 1970
  • Abrasion rate of coarse aggregates is an important factor to determine aggregates quality. Allowable limit of abrasion rate of coarse aggregates for concrete is 40% according to K.S. Strength and durability test of concrete with 19 efferent aggregates were made. From this test, it was found that allowable limit of abrasion rate of aggregates can be increased to 43%.

  • PDF

도로구조물의 발파진동 허용기준에 관한 연구 (Study on the Allowable Limit of Blasting-induced Vibration for Road Structures and Facilities)

  • 손무락;홍두표;권오철;정연권;황영철;박두희
    • 한국지반공학회논문집
    • /
    • 제30권12호
    • /
    • pp.27-40
    • /
    • 2014
  • 본 논문은 도로구조물 및 시설물들에 대한 발파진동 허용기준들을 도출하고 그 결과를 제시하고자 한 것이다. 본 연구를 위해서 우선 현재 국내 외에서 사용되는 다양한 구조물들에 대한 발파진동 허용기준들에 대해서 조사하였으며, 이를 통해 국내에서 적용되는 발파진동 허용기준들에 관련되는 문제점을 분석하고 이를 해소하기 위한 방안을 제시하였다. 더 나아가 본 연구에서는 국내 외에서 사용되는 다양한 발파진동 허용기준들을 상호 비교 및 분석한 후 교량 및 터널 등의 도로구조물 및 시설물들에 대한 발파진동 허용기준으로서 국내에서 사용할 수 있는 기준들을 구조물별로 제시하였다. 제시된 기준들의 실무적용을 위한 타당성 검증을 위해서 현장에서 계측되고 관측된 발파진동 유발 구조물 피해사례들을 수집한 후 제시된 기준들과 상호 비교분석하였다. 뿐만 아니라 제시된 기준들은 이론적 접근방법 및 수치해석적 방법을 통한 결과들과도 상호 비교분석하였다. 비교분석결과 제시된 도로구조물 및 시설물별 발파진동 허용기준들은 실무적용을 함에 있어서 타당성이 있는 것으로 나타났다. 이와 같은 결과를 통해서 본 연구에서 제시된 기준들은 향후 국내 외 도로구조물 및 시설물들의 발파진동에 따른 피해유무를 판단하기 위한 기준으로서 실무에서 유용하게 활용될 수 있을 것으로 기대된다.