• Title/Summary/Keyword: Alloplastic

Search Result 107, Processing Time 0.023 seconds

THE CASES REPORT OF ANKYLOSIS (악관절 강직증의 치험례)

  • Hyun, Young-Ok;Kang, Chang-Hee;Noh, Yang-Ho;Chun, Young-Doo;Kim, Shin-Hun;Lee, Hee-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.1
    • /
    • pp.95-102
    • /
    • 2001
  • Temporomandibular ankylosis is defined as a situation in which the condyle is fused to the fossa by bone or fibrous tissue. Conditons such as trauma, infection, or systemic disease may predispose to various types of ankylosis, bringing about different levels of limitation in mandibular movement. Most patients with temporomandibular ankylosis are associated with limitation of maximal mouth opening, deviation of the chin toward the affected side, impaired occlusion, chronic pain, compromised oral hygiene, severe facial asymmetry & impeded mandibular molar eruption occurring in childhood. Several techniques to release ankylosis have been described in the literature, showing variable and often unsatisfactory results. The most frequently used operations are gap arthroplasty, interpositional arthroplasty, and exicision and joint reconstruction with autogenous or alloplastic materials. We have managed the two patients of TMJ ankylosis. They had previously TMJ surgery and we treated with gap arthroplasty & active physial therapy. We have obtained favorable results and report these cases with literatures review.

  • PDF

INTERPOSITIONAL ARTHROPLASTY OF TEMPOROMANDIBULAR JOINT ANKYLOSIS WITH TEMPORALIS MYOFASCIAL FLAP (측두근-근막피판을 이용한 악관절 강직증의 외과적 재건)

  • Nam, Jung-Soon;Lee, Yong-Gyoo;Kwon, Tae-Geon;Kim, Jong-Bae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.5
    • /
    • pp.544-549
    • /
    • 2000
  • The treatment of TMJ ankylosis poses a significant challenge because of technical difficulties and high incidence of recurrence. TMJ ankylosis has been treated by excision and total joint reconstruction with alloplastic, allogeneic, autogenous materials as interpositional materials. The temporalis myofascial flap had been considered to be a successful interpositional material, due to its anatomical, topographical, and functional properties. This study evaluated the efficacy of the temporalis myofascial flap for nine TMJs (five patients) through the preauricular approach and coronoidectomy. Radiographic and physiologic long term result was investigated in this study. The result reveals that the temporalis myofascial flap is a good autogenous tissue satisfying the criteria of an ideal interpositional material, which offers a material that fulfills the physiological function of the disc. In spite of favorable functional outcome, mild postoperative openbite tendency remains another challenge.

  • PDF

Retrospective analysis of 79 patients with orbital floor fracture: outcomes and patient-reported satisfaction

  • Senese, Olivier;Boutremans, Edward;Gossiaux, Caroline;Loeb, Isabelle;Dequanter, Didier
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.2
    • /
    • pp.108-113
    • /
    • 2018
  • Background: The aim of our retrospective study is to evaluate the management of isolated orbital floor fractures considering the clinical, functional and aesthetic results according to the surgical approach and the type of materials used. Methods: Retrospectively, clinical, radiological, surgical, and ophthalmological data from 79 patients were collected from January 2010 to December 2016. Furthermore, included patients were interrogated on functional and aesthetic satisfaction. Results: The main causes of trauma were physical aggression followed by accidents. The median time between trauma and surgery was 4 days. The most common surgical approaches were the subciliary and the transconjunctival ones. Alloplastic materials were used in 75 patients. In two patients, we used a combination of two grafts. Patients experienced minor immediate complications. On follow-ups, none of our patients suffered from ocular movement restrictions. Patients treated by subciliary approach had higher risk of retractile scaring compared to other surgical approaches. In our study, patients agreed to complete a questionnaire assessing functional and aesthetic outcomes with a high satisfaction score. No association between the implant material used and the results has been assessed. Conclusion: This study describes the results of orbital floor reconstructions. Despite a variety of materials used and surgical approaches performed, we believe that the transconjunctival approach is the most suitable option with a high satisfaction score.

Orbital Floor Reconstruction Using Endoscope and Selected Urethral Balloon Catheter (내시경과 선택적 도뇨관 풍선을 이용한 안와하벽복원술)

  • Choi, Hwan-Jun;Lee, Joo-Chul;Lee, Hyung-Gyo;Kim, Jun-Hyuk
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.35-42
    • /
    • 2011
  • Purpose: Blow-out fractures can be reduced using various methods. The orbital reconstruction technique using a balloon under endoscopic control has advantages over other methods. However, this method has some problems too, such as postoperative follow-up, management of the balloon catheter, and reduction of the posterior orbital floor. Thus, we developed a simple, effective method for orbital floor reduction that involves molding and shaping the antral balloon catheter. Methods: A 0, 30, or $70^{\circ}$, 4-mm endoscope was placed though a two-point, 5-mm maxillary antrostomy. The balloon catheter is placed directly at the orbital apex to reconstruct the anterior shelf (spherical shape), while it is turned in a U-shape towards the anterior maxilla for the posterior shelf (elliptical shape). Orbital floor defects, compound or comminuted fractures are reconstructed with alloplastic materials through an open lid incision under the endoscopic control. Results: This technique was applied to ten patients with orbital floor fractures: five anterior shelf and five posterior shelf fracture, respectively. Four of the patients had zygomatico-orbital fractures, while the rest had isolated orbital floor fractures. Two patients were given porous polyethylene implants Synpor$^{(R)}$) and three underwent reconstruction with a resorbable mesh plate. No complication associated with this technique was identified. Conclusion: The freestyle placement and selection of a urinary balloon catheter under endoscopic control and the preoperative estimation of the volume enhanced the stabilization of the orbital contour. This method improves the adaptation of the orbital floor without the risk of injuring the surrounding orbital contents, dissecting blindly, or using sharp traction. One drawback of this method is the patient's discomfort from the catheter during treatment.

CT and scintigraphic evaluation of osseointegration following immediate versus delayed implantation in dogs (개에서 즉시형과 지연형 인공치아 식립후 골유합에 대한 CT와 신티그라피 평가)

  • Kim, Juoog-Hyun;Lee, Jae Yeong;Lee, Won-Guk;Oh, Won Young;Kim, So-Seob;Kang, Seong Soo;Choi, Seok Hwa
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.1
    • /
    • pp.131-136
    • /
    • 2004
  • Osseointegration involves anchoring dental implants to stable bone rather than to soft-tissue. Clinical osseointegration is currently defined as the process whereby alloplastic material is asymptomatically and rigidly fixed and maintained in bone during functional loading. Full osseointegration is necessary for the success of long-term dental implants. Recent developments in computer assisted measurement of bone formation have improved maxillofacial examination and osseointegration. Computer assisted examination has also proved effective in dental implantology. This investigation was aimed to determine osseointegration in immediate and delayed implantation in the dog mandible using dental computed tomography (CT) and bone scintigraphy. Five adult (mean age of 2 years) mongrel dogs with a mean weight of 9.1 kg were used in this investigation. Titanium alloy implant systems with 4 mm in diameter and 10 mm in length were chosen for insertion. The second and third left mandibular premolars in each dog were extracted for the delayed implant insertion. Twelve weeks later, the second and third right mandibular premolars were extracted for the immediate implant insertion. Before the delayed and immediate implantation procedures and 0, 4, 8, and 12 weeks after the insertions, dental CT and scintigraphy were conducted. The CT and scintigraphic images indicate that reconstruction of bone surrounding of the immediate implant can be as successful as reconstruction of bone surrounding of the delayed implant.

Easy Molding Technique of Methylmethacrylate Implant Using Plaster and Rapid Prototyping Model in Cranioplasty (두개골 성형술에서 석고와 신속조형모델을 이용한 간단한 Methylmethacrylate 삽입물 제작법)

  • Park, Ki Rin;Kim, Yong-Ha;Kim, Tae Gon;Lee, Jun Ho;Ha, Ju Ho
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.2
    • /
    • pp.125-129
    • /
    • 2012
  • Purpose: Methylmethacrylate is the most commonly used alloplastic material in cranioplasty. However during the polymerization of methylmethacrylate, a significant exothermic reaction takes place. This reaction may result in thermal injury to the brain tissue and other soft tissues. Also it is difficult to make three-dimensional methylmethacrylate implant that is perfectly matched to the defect during the operation time. We report on the molding technique of methylmethacrylate implant using plaster mold and the rapid prototyping model in cranioplasty. Methods: A 44-year-old male was referred to the department for severe frontal hollowness. He was involved in an automobile accident resulting in large frontal bone defect with irregular margin. The preformed patient-specific methylmethacrylate implant was made using plaster mold and the rapid prototyping model before the operative day. The methylmethacrylate implant was placed in the frontal defect and rigidly fixed with miniplates and screws on the operative day. Results: The operation was performed in an hour. In the 6 months follow-up period, there were no complications. Patient was satisfied with the results of cranioplasty. Conclusion: Safe cranioplasty was performed with the preformed patient-specific methylmethacrylate implant using plaster mold and the rapid prototyping model. The result of this method was satisfactory, aesthetically and functionally.

Effectiveness of autogenous tooth bone used as a graft material for regeneration of bone in miniature pig (미니피그에서 자가치아뼈 이식의 골형성 효과에 대한 연구)

  • Jeong, Hye-Rin;Hwang, Ju-Hong;Lee, Jeong-Keun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.5
    • /
    • pp.375-379
    • /
    • 2011
  • Introduction: This study examined the effect of autogenous tooth bone used as a graft material for bone regeneration in an artificial bony defect of minipigs. Materials and Methods: Four healthy minipigs, weighing approximately 35-40 kg, were used. Four standardized artificial two-walled bony defects, 5 mm in length and depth, were made on the bilateral partial edentulous alveolar ridge on the mandible of minipigs, and autogenous tooth bone was augmented in the right side as the experimental group. On the other hand, only alloplastic bone graft material HA was grafted with the same size and manner in the left side as the control group. All minipigs were sacrificed at 4 weeks after a bone graft and evaluated histologically by Haematoxylin-eosin staining. The specimens were also evaluated semi-quantitatively via a histomorphometric study. The percentage of new bone over the total area was evaluated using digital software for an area calculation. Results: All specimens were available but one in the left side (control group) and two in the right side (experimental group) were missing during specimen preparation. The amount of bone formation and remodeling were higher in all experimental groups than the control. The mean percentage area for new bone in the experimental and control groups was $43.74{\pm}11.96%$ and $30.79{\pm}2.93%$, respectively. Conclusion: Autogenous tooth bone is a good alternative to autogenous bone with the possible clinical feasibility of an autogenous tooth bone graft in the reconstruction of bony defects.

Various Flap for Treatment of Radiation Ulcer and Osteoradionecrosis (골괴사를 동반한 만성 방사선 궤양의 치료를 위한 피판술)

  • Yun, In Sik;Lee, Won Jai;Jeong, Hii Sun;Lew, Dae Hyun;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.174-180
    • /
    • 2008
  • Purpose: While radiotherapy remains an essential part of the multidisciplinary treatment of cancers, it may cause unwanted consequences such as tissue break down and chronic non-healing wounds as a result of hypoxia, hypovascularity, and hypocellularity. The conservative treatment of osteoradionecrosis was effective only in the early stages or has a limited result. The surgical treatment of osteoradionecrosis includes various local fasciocutaneous flaps, local myocutaneous flaps and different kinds of free flaps with cancellous bone graft or alloplastic material after removal of all devitalized tissue. This study reviews recent cases of osteoradionecrosis in Severance hospital and investigates the use of various flaps for reconstruction of osteoradionecrosis. Methods: From 2000 to 2006, a total of 29 patients, nine men and twenty women with a mean age of 60.4 years were identified and included in the study. Fasciocutaneous flaps were used on 7 patients and myocutaneous flaps were used on the remaining patients. Mean follow-up period was 10.4 months. Results: In the fasciocutaneous flap group, we noted two complications including total flap failure and a partial flap necrosis. In the myocutaneous flap group, four complications were noted including a partial flap necrosis and 3 cases of wound dehiscence. Considering the complications noted in this study, the natural history of progression to flap necrosis appeared to follow the following sequence of events: marginal flap necrosis, infection, wound dehiscence, flap floating and partial flap necrosis, serially. Conclusion: Successful surgical treatment of osteoradionecrosis includes wide radical debridement and reconstruction with a well vascularized flap like myocutaneous flap or fasciocutaneous flap.

Epidermal Cyst of the Nasal Tip Presenting as Foreign Body Reaction (이물 반응으로 오인된 비첨부 표피 낭종)

  • Choi, Chang Yong;Choi, Hwan Jun
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.105-108
    • /
    • 2009
  • Purpose: Epidermoid cyst may be congenital or acquired. Acquired cysts are most commonly of traumatic origin and result from an implantation or downward displacement of an epidermal fragment. Traumatic epidermoid cysts are rare tumors occurring on the nasal tip, especially resulting aesthetic procedure. So, we report a rare case of an iatrogenic epidermoid cyst in the nasal tip following rhinoplasty. Methods: A 44 - years old man had undergone rhinoplasty for several times. First time, the previous augmentation rhinoplasty and wedge osteotomy were performed nineteen months ago, lastly implant removal and unknown filler injection were performed one year ago at another local clinic. He had induration and tenderness on nasal tip and dorsum continued for 3 months. We thought that it caused by foreign body reaction with residual alloderm in nose. For removal of residual alloplastic material, open approach using transcolumellar incision was done. But, incidentally we found cystic mass on the nasal tip. Results: The findings were of an $0.8{\times}0.5{\times}0.5cm$ sized round cystic mass containing cream coloured material with a thick cheese - like consistency. The mass was completely excised and submitted for histology. This confirmed the diagnosis of an epidermoid cyst lined by keratinizing squamous epithelium. There was no induration, tenderness and sign of recurrence after excision of the mass. Conclusion: Epidermal cyst of the nasal tip region represents an unusual clinical lesion and it presents as foreign body reaction. And then, our case demonstrates that meticulous surgical approach and suture technique are the keys to prevention against iatrogenic nasal epidermoid cyst, especially in secondary rhinoplasty.

Forehead Augmentation with a Methyl Methacrylate Onlay Implant Using an Injection-Molding Technique

  • Park, Dong Kwon;Song, Ingook;Lee, Jin Hyo;You, Young June
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.597-602
    • /
    • 2013
  • Background The forehead, which occupies about one third of the face, is one of the major determinants of a feminine or masculine look. Various methods have been used for the augmentation of the forehead using autologous fat grafts or alloplastic materials. Methylmethacrylate (MMA) is the most appropriate material for augmentation of the forehead, and we have used an injection-molding technique with MMA to achieve satisfactory results. Methods Under local anesthesia with intravenous (IV) sedation, an incision was made on the scalp and a meticulous and delicate subperiosteal dissection was then performed. MMA monomers and polymers were mixed, the dough was injected into the space created, and manual molding was performed along with direct inspection. This surgery was indicated for patients who wanted to correct an unattractive appearance by forehead augmentation. Every patient in this study visited our clinics 3 months after surgery to evaluate the results. We judged the postoperative results in terms of re-operation rates caused by the dissatisfaction of the patients and complications. Results During a 13-year period, 516 patients underwent forehead augmentation with MMA. With the injection-molding technique, the inner surface of the MMA implant is positioned close to the underlying frontal bone, which minimizes the gap between the implant and bone. The borders of the implant should be tapered sufficiently until no longer palpable or visible. Only 28 patients (5.4%) underwent a re-operation due to an undesirable postoperative appearance. Conclusions The injection-molding technique using MMA is a simple, safe, and ideal method for the augmentation of the forehead.