• 제목/요약/키워드: All-on-4 implant

검색결과 545건 처리시간 0.026초

상악동저 거상술 후 상악 구치부에 식립된 임플란트의 생존율에 대한 연구 (Survival analysis of implants placed in the sinus floor elevated maxilla)

  • 박종연;김옥수;류경호
    • Journal of Periodontal and Implant Science
    • /
    • 제37권2호
    • /
    • pp.151-164
    • /
    • 2007
  • Objective: The sinus floor elevation procedures have been used to facilitate implant placement in the severely atrophic posterior maxilla. Many variables may have an influence on the outcomes of the sinus floor elevation in combination with implant treatment. The aim of this study was to analyze survival rate of implants placed in the edentulous maxillae of patients in whom sinus floor elevation was undertaken according to variables. Materials and Methods: It consisted of 96 patients(50 male and 46 female), ranging in age from 31 to 70 years(mean 49 years), who underwent sinus floor elevation procedure(94 implants in left side and 106 implants in right side) from 2001 to 2002. A total of 200 implants were placed in the grafted sinus(73 implants in lateral approach and 127 implants in crestal approach). All implants were restored by fixed prosthesis. All patients were healthy. Follow-up periods for implants were between 48 to 60 months. Results: The cumulative survival rate of implants was 91.5%. Gender, age and operation site did not have an influence on the survival rate. There was statistically significant differences for the implants which placed in less than 4 or 5 rom residual bone height, the survival rate was 60%, 81.4% respectively (p<0.05). There was no statistically significant difference of implants survival rate ac- cording to approach technique. The survival rate for 100% autogenous bone grafts was lower with respect to composite grafts containing autogenous bone and 100% substitutes. The survival rate for hydroxyapatite-coated implants was statistically significant lower than other textured group (p<0.05). Conclusion: Residual bone height, surface texture and graft materials have an influence on the survival rate. To use autogenous bone as a part of a composite bone replacement, implant texture which leads to more favorable implant-bone interface were necessary. To determine residual bone height for initial implant stability was important.

TG Osseotite 임플란트의 성공률에 대한 임상적 연구 (CLINICAL STUDY ON SUCCESS RATE OF TG OSSEOTITE IMPLANT)

  • 오승환;민승기;채영원
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권1호
    • /
    • pp.39-47
    • /
    • 2005
  • The purpose of this study is to review the prognosis of the TG Osseotite implant(3i Co, USA) placed in partial edentulous area of oral cavity and to suspect the possible causes leading to failure. 124 TG Osseotite implants that had been inserted between 2000 - 2002 were followed up for 2 years(avg : 9.5 months) in function. Medical records, and radiographs were evaluated and analyzed by the over all success rate, gender and age factor, general disease, implant fixture length and diameter, implant site, bone density, and various surgical methods. Chi square test was used statistically. Of the 124 TG Osseotite implants, 9 implants(7.3%) were removed in early phase and 3 implants(2.4%) were in late phase. The cumulative survival rate was 90.2%. The failure of the TG Osseotite implant was closely related with the use of bone graft techniques such as sinus elevation or immediate implantation and not with the age, sex, general disease, implant site, bone density of implanted site. The failure of the TG Osseotite implant was well developed when it was the wide type of implant and it was inserted for single tooth replacement. The developement of peri-implantitis was the most important factor in the failure of the TG Osseotite implant.

임프란트에 부착하는 세균의 동정 및 효과적인 항생제 선택 (ORAL MICROBES ASSOCIATED WITH TITANIUM IMPLANT AND THEIR ANTIBIOTIC SUSCEPTIBILITY)

  • 김선권;유선열
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제19권4호
    • /
    • pp.383-394
    • /
    • 1997
  • This study was done to examine adherence of oral bacteria to titanium dental implant and to know the effective prophylactic antibiotics using an in vivo model. Three samples each of the implant material were set in an acrylic resin flange and placed in the maxillary buccal sulcus of twenty volunteers. At 6- and 54-hour intervals, each sample was placed on blood agar plate (BAP) and chocolate agar, and then they were incubated and identified. Also antibiotic susceptibility test was performed. The results obtained mere as follows ; 1. The microorganisms were chain-like Gram positive cocci and staphyline Gram positive cocci, Gram positive bacilli in order of frequency were found at 6-hour and 54-hour samples by Gram staining. 2. Streptococci was found predominantly at both 6-hour and 54-hour samples, but number of streptococci was decreased as compared to 6-hour samples. 3. There was no difference in the bacterial species adherent to implant between 6-hour and 54-hour samples. 4. All the microbes were sensitive to AMC (amoxacillin clavulanic acid), chloramphenicol, quinolone and vancomycin in the antibiotic susceptibility test. Above results suggest that streptococcus are mainly adhered to titanium implant after implant was placed in the oral cavity and AMC is the most recommendable antibiotics to prevent the peri-implant inflammation.

  • PDF

Efficacy of Spinal Implant Removal after Thoracolumbar Junction Fusion

  • Kim, Seok-Won;Ju, Chang-Il;Kim, Chong-Gue;Lee, Seung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권3호
    • /
    • pp.139-142
    • /
    • 2008
  • Objective: The purpose of this study was to evaluate the efficacy of spinal implant removal and to determine the possible mechanisms of pain relief. Methods: Fourteen patient~with an average of 42 years (from 22 to 67 years) were retrospectively evaluated. All patients had posterior spinal instrumentation and fusion, who later developed recurrent back pain or persistent back pain despite a solid fusion mass. Patients' clinical charts, operative notes, and preoperative x-rays were evaluated. Relief of pain was evaluated by the Visual Analog Scale (VAS) pain change after implant removal. Clinical outcome using VAS and modified MacNab's criteria was assessed on before implant removal, 1 month after implant removal and at the last clinical follow-up. Radiological analysis of sagittal alignment was also assessed. Results: Average follow-up period was 18 months (from 12 to 25 months). There were 4 patients who had persistent back pain at the surgical site and 10 patients who had recurrent back pain. The median time after the first fusion operation and the recurrence of pain was 6.5 months (from 3 to 13 months). All patients except one had palpation pain at operative site. The mean blood loss was less than 100ml and there were no major complications. The mean pain score before screw removal and at final follow up was 6.4 and 2.9, respectively (p<0.005). Thirteen of the 14 patients were graded as excellent and good according to modified MacNab's criteria. Overall 5.9 degrees of sagittal correction loss was observed at final follow up, but was not statistically significant. Conclusion: For the patients with persistent or recurrent back pain after spinal instrumentation, removal of the spinal implant may be safe and an efficient procedure for carefully selected patients who have palpation pain and are unresponsive to conservative treatment.

즉시형과 지연형 치아 임플란트에서 Tc-99m-MDP의 Bone Uptake 평가 (Evaluation of Bone Uptake on Tc-99m-MDP in Immediate and Delayed Dental Implants)

  • 김중현;김명환;이원국;이재영;강성수;최석화
    • 한국임상수의학회지
    • /
    • 제20권2호
    • /
    • pp.207-211
    • /
    • 2003
  • This investigation aimed to determine the relative merit of osseointegration in immediate and delayed implantation in the dog mandible using radiography and bone scintigraphy. five adult mongrel dogs with a mean weight of 8.5 kg were used in this investigation. During the entire study period. all dogs were fed with a soft commercial diet and water ad libitum to minimize functional loading of the implant. Twenty titanium alloy systems 4 mm in diameter and 10 mm in length blasted with calcium phosphate were prepared for insertion. The second and third left mandibular premolars in each dog were extracted for the delayed implant insertion. Twelve weeks later, the second and third right mandibular premolars were extracted for the immediate implant insertion. Before the delayed and immediate implantation procedures and 0, 4, 8, and 12 weeks after the insertions, radiography and bone scintigraphy were conducted. Bone scans were obtained using a large field of view gamma camera equipped with a collimator about 3 hours after intravenous injection of Tc-99m-MDP to the dogs. All the dogs were evaluated weekly for inflammation, necrosis, and other of the bone or sort tissue. Significant macroscopic lesions were not detected. Radioisotope scintigraphy with Tc-99m-MDP hat proved to be a reliable method for measuring increased bone activity at specific skeleton tissue sites. In conclusion, osseointegration in peri-implant bone did not differ significantly between the immediate and delayed implant procedures during the experimental period. The immediate implant may be an alternative treatment of implant insertion in animals.

Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures

  • Shim, Hye Won;Yang, Byoung-Eun
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권6호
    • /
    • pp.423-430
    • /
    • 2015
  • PURPOSE. To evaluate the cumulative survival rate (CSR) and mechanical complications of single-tooth $Ankylos^{(R)}$ implants. MATERIALS AND METHODS. This was a retrospective clinical study that analyzed 450 single $Ankylos^{(R)}$ implants installed in 275 patients between December 2005 and December 2012. The main outcomes were survival results CSR and implant failure) and mechanical complications (screw loosening, fracture, and cumulative fracture rate [CFR]). The main outcomes were analyzed according to age, sex, implant length or diameter, bone graft, arch, and position. RESULTS. The 8-year CSR was 96.9%. Thirteen (2.9%) implants failed because of early osseointegration failure in 3, marginal bone loss in 6, and abutment fracture in 4. Screw loosening occurred in 10 implants (2.2%), and 10 abutment fractures occurred. All abutment fractures were located in the neck, and concurrent screw fractures were observed. The CSR and rate of screw loosening did not differ significantly according to factors. The CFR was higher in middle-aged patients (5.3% vs 0.0% in younger and older patients); for teeth in a molar position (5.8% vs 0.0% for premolar or 1.1% for anterior position); and for larger-diameter implants (4.5% for 4.5 mm and 6.7% for 5.5 mm diameter vs 0.5% for 3.5 mm diameter) (all P<.05). CONCLUSION. The $Ankylos^{(R)}$ implant is suitable for single-tooth restoration in Koreans. However, relatively frequent abutment fractures (2.2%) were observed and some fractures resulted in implant failures. Middle-aged patients, the molar position, and a large implant diameter were associated with a high incidence of abutment fracture.

임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향 (INFLUENCE OF IMPLANT FIXTURE DESIGN ON IMPLANT PRIMARY STABILITY)

  • 오갑용;박성화;김석규
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.98-106
    • /
    • 2007
  • Statement of problem: Current tendencies of the implant macrodesign are tapered shapes for improved primary stability, but there are lack of studies regarding the relationship between the implant macrodesign and primary stability. Purpose: The purpose is to investigate the effect of implant macrodesign on the implant primary stability by way of resonance frequency analysis in the bovine rib bones with different kinds of quality. Material and method: Fifty implants of 6 different kinds from two Korean implant systems were used for the test. Bovine rib bones were cut into one hundred pieces with the length of 5 cm. Among them forty pieces of rib bones with similar qualities were again selected. For the experimental group 1, the thickness of cortical part was measured and 20 pieces of rib bones with the mean thickness of 1.0mm were selected for implant placement. For the experimental group 2, the cortical parts of the remaining 20 pieces of rib bones were totally removed and then implants were placed on the pure cancellous bone according to the surgical manual. After placement of all implants, the implant stability quotient(ISQ) was measured by three times, and its statistical analysis was done. Results: There are statistically significant differences in ISQ values among 4 different kinds of Avana system implants in the experimental group 2. For the experimental group 1, Avana system implants showed significantly different ISQ values, but when differences in the thickness of cortical parts were statistically considered, did not show any significant differences in ISQ values. Among Oneplant system implants, there are no significant differences in ISQ values for the experimental group 2 as well as for the experimental group 1. Conclusion: Within the limits of this study, bone quality and implant design have some influences on the primary stability of implants. Especially in the bone of poor quality, tapered shape of implants are more favorable for the primary stability of implants.

치근형 골내 임플란트의 초기 1년간 치조골 소실 및 골 밀도 변화에 관한 연구 (ALVEOLAR BONE LOSS & BONE DENSITY CHANCES DURING THE FIRST YEAR A COMPARATIVE STUDY ON FOUR TYPES OF ROOT-FORM ENDOSSEOUS DENTAL IMPLANT SYSTEMS)

  • 정영철;한종현;이근우
    • 대한치과보철학회지
    • /
    • 제32권3호
    • /
    • pp.455-469
    • /
    • 1994
  • Regular radiographic examination has been considered an essential diagnositic method for osseointegrated dental implantation. This study investigated marginal bone loss through the measurement on periapical radiographs and changes in bone density through digital subtraction image radiographic method around 88 endoseous root-form dental implants in 43 human subjects. Four types of endosseous dental implants were investigated : Standard series, Mini series and Hex-lock system of Steri-Oss Dental implant system, and $Br{\aa}nemark$-type implant from 3i dental implant system, in a 3 month interval for a total period of 12 months. The results were as follows : 1. Rapid bone loss occurred in the first 3 months in all 4 groups, and the bone level stabilized at the first thread of the implant fixtures. Amount of bone loss for 12 months showed correlation with the length of the polished neck portion. 2. Most of the implant systems showed resorption of alveolar bone up to the polished neck portion although a long polished neck could delay the resolution. 3. Alveolar bone loss apical to the polished neck portion stabilized at the first thread of the fixtures with no correlation to either the time of exposure of the polished neck or types of implant systems. 4. No changes in bone density around the implant threads were observed throughout the experimental period. Bone density decreased at the marginal bone, and increased at the newly-formed alveolar crest. These results indicate that most of the alveolar bone loss occur within the first 12 months after installation of endosseous root-form dental implants resulting in the exposure of polished neck portions, and the bone level stabilizes thereafter at the first thread portions of the implant fixtures. The experimental period of 12 months seems insufficient for observing changes in bone density, and a long-term observation should be needed.

  • PDF

인공치아 매식술 계획에 있어서 상이한 단층두께의 나선형 단층사진의 비교 (A Comparative Study of Spiral Tomograms with Different Slice Thicknesses in Dental Implant Planning)

  • 윤숙자
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.191-201
    • /
    • 1999
  • Purpose: To know whether there would be a difference among spiral tomograms of different slice thicknesses in the measurement of distances which are used for dental implant planning. Materials and Methods: 10 dry mandibules and 40 metal balls were used to take total 120 Scanorailll tomograms with the slice thickness of 2 mm, 4 mm and 8 mm. 3 oral radiologists interpreted each tomogram to measure the distances from the mandibular canal to the alveoalr crest and buccal. lingual and inferior borders of mandible. 3 observers recorded grades of 0, 1 or 2 to evaluate the perceptibility of alveolar crest and the superior border of mandibular canal. ANOVA with repeated measure. Chi-square tests and intrac!ass correlation coefficient(R₂, α) were used For statistical analysis. Results: There was not a statistically significant difference among spiral tomograms with different slice thicknesses in the measurement of the distances and in the perceptibility of alveolar crest and mandibular canal(p>0.05). All of them showed a good relationship in the reliability analysis. The perceptibility of alveolar crest and mandibular canal was almost similar and an excellent relationship was seen on all of them. Conclusions: There would be no significant difference. no matter which spiral tomogram of any slice thickness may be used in dental implant planning. considering the thickness of dental implant fixture.

  • PDF

Effect of the size of the bony access window and the collagen barrier over the window in sinus floor elevation: a preclinical investigation in a rabbit sinus model

  • Sim, Jeong-Eun;Kim, Sangyup;Hong, Ji-Youn;Shin, Seung-Il;Chung, Jong-Hyuk;Lim, Hyun-Chang
    • Journal of Periodontal and Implant Science
    • /
    • 제52권4호
    • /
    • pp.325-337
    • /
    • 2022
  • Purpose: The aim of this study was to investigate the effect of (1) the size of the bony access window and (2) collagen membrane coverage over the window in sinus floor elevation in a rabbit sinus model. Methods: Small bony access windows (SW; ø 2.8 mm) were made in 6 rabbits and large windows (LW; ø 6 mm) in 6 other rabbits. Both sinuses in each rabbit were allocated to groups with or without coverage of a collagen membrane (CM) on the window, resulting in 4 groups: SW, LW, SW+CM, and LW+CM. After 4 weeks of healing, micro-computed tomographic, histologic, and histomorphometric analyses were performed. Results: Bony healing in the window area was incomplete in all groups, but most bone graft particles were well confined in the augmented cavity. Histologically, the pattern of new bone formation was similar in all groups. Histomorphometrically, the percentage of newly formed bone was greater in the groups with CM than in the groups without CM, and in the groups with SW than in the groups with LW (12.92%±6.40% in the SW+CM group, 4.21%±7.73% in the SW group, 10.45%±4.81% in the LW+CM group, 11.77%±3.83% in the LW group). The above differences were not statistically significant (P>0.05). Conclusions: The combination of a small bony access window and the use of a collagen membrane over the window favored new bone formation compared to other groups, but this result should be further investigated due to the limitations of the present animal model.