• Title/Summary/Keyword: All-in-one adhesive

Search Result 193, Processing Time 0.024 seconds

MICROTENSILE BOND STRENGTH OF ALL-IN-ONE ADHESIVE TO CARIES-AFFECTED DENTIN (우식이환 상아질에 대한 all-in-one adhesive의 미세인장결합강도)

  • Moon, Ji-Deok;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.49-57
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength to caries-affected dentin. Twenty one extracted human molars with occlusal caries extending into mid-dentin were prepared by grinding the occlusal surface flat. The carious lesions were excavated with the aid of caries detector dye. The following adhesives were applied to caries-affected dentin according to manufacturer's directions; $Scotchbond^{TM}$ Multi-Purpose in SM group, Adper Prompt $L-Pop^{TM}$ 1 coat in LP1 group, 2 coats in LP2 group, 3 coats in LP3 group, $Xeno^{(R)}$ III 1 coat in XN1 group, 2 coats in XN2 group. and 3 coats in XN3 group. After application of the adhesives, a cylinder of resin-based composite was built up on the occlusal surface. Each tooth was sectioned vertically to obtain the $1{\times}1\;mm^2$ sticks. The microtensile bond strength was determined. Each specimen was observed under SEM to examine the failure mode. Data were analyzed with one-way ANOVA. The results of this study were as follows; 1. The microtensile bond strength values were; SM ($14.38{\pm}2.01$ MPa), LP1 ($9.15{\pm}1.81$ MPa), LP2(14.08{\pm}1.75$ MPa), LP3 ($14.06{\pm}1.45$ MPa). XN1 (13.65{\pm}1.95$ MPa). XN2 ($13.98{\pm}1.60$) MPa, XN3 ($13.88{\pm}1.66$) MPa, LP1 was significantly lower than the other groups in bond strength (p < 0.05). All groups except LP1 were not significantly different in bond strength (p > 0.05). 2. In LP1, there were a higher number of specimens showing adhesive failure. Most specimens of all groups except LP1 showed mixed failure.

INFLUENCE OF APPLICATION METHODS OF A DENTIN ADHESIVE ON SHEAR BOND STRENGTH AND ADHESIVE PATTERN (상이질 접착제의 적용방법에 따른 전단결합강도와 접착양상에 관한 연구)

  • Park, Sung-Taek;Moon, Joo-Hoon;Cho, Young-Gon;Ohn, Yeong-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.381-391
    • /
    • 1999
  • A new 5th generation adhesive system(ONE-STEP) has been supplied which operators can apply to conditioned tooth surfaces by one simplified step. The purpose of this study was to determine whether different methods of adhesive application and various air drying duration after applying adhesive affect the shear bond strength of composite resin to dentin, and to evaluate the adhesive pattern of composite resin and dentin under SEM. Seventy-seven extracted human molar teeth were cleaned and mounted in palstic test tubes. The occlusal dentin surfaces were exposed with Diamond Wheel Saw and smoothed with Lapping and Polishing Machine (South Bay Technology Co., U.S.A.). Teeth were randomly divided into 7 groups (n=11), In experimental A group, adhesive was applied to dentin with agitation for 20 sec. In experimental N-A group, adhesive were continuously applied to dentin for 20 sec. Also control and experimental 1, 2, 3, 4 groups were dried for 10, 0, 5, 20, 30 seconds after applying adhesive, respectively, Adhesives were light cured for 10 sec. A gelatin capsule 5mm in diameter was filled with Aelitefil$^{TM}$ composite resin, placed on the treated dentin surface and light cured for 40 see, from three sides, All specimens were stored in distilled water at room temperature for 24 hours. The shear bond strengths were measured using a universal testing machine(AGS-1000 4D, Japan) at a crosshead speed of 5mm/min. An one-way ANOVA and LSD test were used for statistical analysis of the data. For SEM evaluation, seven specimens were made and sectioned. Representive postfracture and seven specimens were mounted on brass stubs, sputter-coated with gold and observed under SEM. The results were as follows : 1. The shear bond strength of experimental A group which adhesive were applied to dentin with agitation was higher than that of experimental N-A group (continuous application), and there was significant difference between two groups (p<0.01). 2. The interface between composite and dentin according to different application methods showed close adaptation in experimental A group and showed tinny gap in experimental N-A group. 3. The shear bond strength accoding to various air drying duration was the lowest value(7.57${\pm}$2.60 MPa) in experimental 1 group, so there was significant difference between experimental 1 group and other four groups (p<0.05). But there was no significant difference of shear bond strength between four groups (p>0.05). 4. The interface between composite and dentin according to various air drying duration showed close adaptation in control group and tinny gap in experimental 3 and 4 groups. But experimental 1 and 2 groups showed $30{\mu}$ and 6 - $10{\mu}m$ thick gaps, respectively.

  • PDF

A study on the compatibility between one-bottle dentin adhesives and composite resins using micro-shear bond strength

  • Song, Minju;Shin, Yooseok;Park, Jeong-Won;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Objectives: This study was performed to determine whether the combined use of one-bottle self-etch adhesives and composite resins from same manufacturers have better bond strengths than combinations of adhesive and resins from different manufacturers. Materials and Methods: 25 experimental micro-shear bond test groups were made from combinations of five dentin adhesives and five composite resins with extracted human molars stored in saline for 24 hr. Testing was performed using the wire-loop method and a universal testing machine. Bond strength data was statistically analyzed using two way analysis of variance (ANOVA) and Tukey's post hoc test. Results: Two way ANOVA revealed significant differences for the factors of dentin adhesives and composite resins, and significant interaction effect (p < 0.001). All combinations with Xeno V (Dentsply De Trey) and Clearfil $S^3$ Bond (Kuraray Dental) adhesives showed no significant differences in micro-shear bond strength, but other adhesives showed significant differences depending on the composite resin (p < 0.05). Contrary to the other adhesives, Xeno V and BondForce (Tokuyama Dental) had higher bond strengths with the same manufacturer's composite resin than other manufacturer's composite resin. Conclusions: Not all combinations of adhesive and composite resin by same manufacturers failed to show significantly higher bond strengths than mixed manufacturer combinations.

Effect of different air-drying time on the microleakage of single-step self-etch adhesives

  • Moosavi, Horieh;Forghani, Maryam;Managhebi, Esmatsadat
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.2
    • /
    • pp.73-78
    • /
    • 2013
  • Objectives: This study evaluated the effect of three different air-drying times on microleakage of three self-etch adhesive systems. Materials and Methods: Class I cavities were prepared for 108 extracted sound human premolars. The teeth were divided into three main groups based on three different adhesives: Opti Bond All in One (OBAO), Clearfil $S^3$ Bond (CSB), Bond Force (BF). Each main group divided into three subgroups regarding the air-drying time: without application of air stream, following the manufacturer's instruction, for 10 sec more than manufacturer's instruction. After completion of restorations, specimens were thermocycled and then connected to a fluid filtration system to evaluate microleakage. The data were statistically analyzed using two-way ANOVA and Tukey-test (${\alpha}$ = 0.05). Results: The microleakage of all adhesives decreased when the air-drying time increased from 0 sec to manufacturer's instruction (p < 0.001). The microleakage of BF reached its lowest values after increasing the drying time to 10 sec more than the manufacturer's instruction (p < 0.001). Microleakage of OBAO and CSB was significantly lower compared to BF in all three drying time (p < 0.001). Conclusions: Increasing in air-drying time of adhesive layer in one-step selfetch adhesives caused reduction of microleakage, but the amount of this reduction may be dependent on the adhesive components of self-etch adhesives.

Effect of Hydrophobic, Neutral Adhesive on the Dentin Bond Strength of Self-etching Adhesive

  • Bae, Ji-Hyun;Choi, Yong-Hoon;Jung, Moon-Kyung;Cho, Byeong-Hoon
    • Journal of Korean Dental Science
    • /
    • v.2 no.2
    • /
    • pp.5-11
    • /
    • 2009
  • Objectives : This study investigated the hypothesis that the dentin bond strength of self-etching adhesives (SEAs) may be improved by applying a coat of hydrophobic, neutral adhesive resin in addition to SEA. Method and Materials : The bond strengths of two SEAs - Experimental SEA (EX) and Adper Prompt (AP) - were measured with three bonding protocols. The D/E resin of All-Bond 2 was applied as the hydrophobic, neutral adhesive. Clearfil SE Bond (SE, self-etching primer system) and All-Bond 2 (AB, total etching system) were used as references. The following protocols were used: (1) EX1 (EX 1 coat); (2) EX2 (EX 2 coats); (3) EX+ (EX 1 coat + D/E resin); (4) AP1 (AP 1 coat); (5) AP2 (AP 2 coats); (6) AP+ (AP 1 coat + D/E resin); (7) SE (SE primer + SE bond); (8) SE+ (SE primer + D/E resin); (9) AB (etching + AB primer + D/E resin). Filtek Z250 composite resin was built up and the microtensile bond strength (MTBS) values of the specimens were compared. The fractured surfaces were observed using SEM. Results : When SEA was used as self-etching primer and hydrophobic, neutral adhesive was applied as well, MTBS was significantly higher than that when either one coat or two coats of SEA only were used (p < 0.05). Conclusion : The hydrophobic, neutral adhesive improved the integrity of the bonded interface obtained with SEA.

  • PDF

Microleakage and characteristics of resin-tooth tissues interface of a self-etch and an etch-and-rinse adhesive systems

  • Xuan Vinh Tran;Khanh Quang Tran
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.30.1-30.13
    • /
    • 2021
  • Objectives: This study was conducted to compare the microleakage and characteristics of the resin-tooth tissue interface between self-etch and etch-and-rinse adhesive systems after 48 hours and 3 months. Materials and Methods: 40 extracted premolar teeth were randomly divided into 2 groups: 1-step self-etch adhesive system - OptibondTM All-In-One, and 2-step etch-and-rinse adhesive system - AdperTM Single Bond 2. Both groups were subjected to 500 thermocycles (5℃-55℃) before scanning electron microscope (SEM) analysis or microleakage trial at 48-hour and 3-month time periods. Results: SEM images showed the hybrid layer thickness, diameter, and length of resin tags of the self-etch adhesive (0.42 ± 0.14 ㎛; 1.49 ± 0.45 ㎛; 16.35 ± 14.26 ㎛) were smaller than those of the etch-and-rinse adhesive (4.39 ± 1.52 ㎛; 3.49 ± 1 ㎛; 52.81 ± 35.81 ㎛). In dentin, the microleakage scores of the 2 adhesives were not different in both time periods (48 hours/3 months). However, the microleakage score of etch-and-rinse adhesive increased significantly after 3 months (0.8 ± 0.63 and 1.9 ± 0.88, p < 0.05). Conclusions: The self-etch adhesive exhibited better long-term sealing ability in dentin when compared to that of the etch-and-rinse adhesive. The greater hybrid layer thickness and dimensions of resin tags did not guarantee reliable, long-lasting sealing in the bonding area.

The effect of saliva decontamination procedures on dentin bond strength after universal adhesive curing

  • Kim, Jayang;Hong, Sungok;Choi, Yoorina;Park, Sujung
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.4
    • /
    • pp.299-305
    • /
    • 2015
  • Objectives: The purpose of this study was to investigate the effectiveness of multiple decontamination procedures for salivary contamination after curing of a universal adhesive on dentin bond strength according to its etch modes. Materials and Methods: Forty-two extracted bovine incisors were trimmed by exposing the labial dentin surfaces and embedded in cylindrical molds. A universal adhesive (All-Bond Universal, Bisco) was used. The teeth were randomly divided into groups according to etch mode and decontamination procedure. The adhesive was applied according to the manufacturer's instructions for a given etch mode. With the exception of the control groups, the cured adhesive was contaminated with saliva for 20 sec. In the self-etch group, the teeth were divided into three groups: control, decontamination with rinsing and drying, and decontamination with rinsing, drying, and adhesive. In the etch-and-rinse group, the teeth were divided into four groups: control, decontamination with rinsing and drying, decontamination with rinsing, drying, and adhesive, and decontamination with rinsing, drying, re-etching, and reapplication of adhesive. A composite resin (Filtek Z350XT, 3M ESPE) was used for filling and was cured on the treated surfaces. Shear bond strength was measured, and failure modes were evaluated. The data were subjected to one-way analysis of variation and Tukey's HSD test. Results: The etch-and-rinse subgroup that was decontaminated by rinse, drying, re-etching, and reapplication of adhesive showed a significantly higher bond strength. Conclusions: When salivary contamination occurs after curing of the universal adhesive, additional etching improves the bond strength to dentin.

The effect of dentin desensitizers and Nd:YAG laser pre-treatment on microtensile bond strength of self-adhesive resin cement to dentin

  • Acar, Ozlem;Tuncer, Duygu;Yuzugullu, Bulem;Celik, Cigdem
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.88-95
    • /
    • 2014
  • PURPOSE. The purpose of this study is to evaluate if pre-treatment with desensitizers have a negative effect on microtensile bond strength before cementing a restoration using recently introduced self-adhesive resin cement to dentin. MATERIALS AND METHODS. Thirty-five human molars' occlusal surfaces were ground to expose dentin; and were randomly grouped as (n=5); 1) Gluma-(Glutaraldehyde/HEMA) 2) Aqua-Prep F-(Fluoride), 3) Bisblock-(Oxalate), 4) Cervitec Plus-(Clorhexidine), 5) Smart protect-(Triclosan), 6) Nd:YAG laser, 7) No treatment (control). After applying the selected agent, RelyX U200 self-adhesive resin cement was used to bond composite resin blocks to dentin. All groups were subjected to thermocycling for 1000 cycles between $5-55^{\circ}C$. Each bonded specimen was sectioned to microbars ($6mm{\times}1mm{\times}1mm$) (n=20). Specimens were submitted to microtensile bond strength test at a crosshead speed of 0.5 mm/min. Kolmogorov-Smirnov, Levene's test, Kruskal-Wallis One-way Analysis of Variance, and Conover's nonparametric statistical analysis were used (P<.05). RESULTS. Gluma, Smart Protect and Nd:YAG laser treatments showed comparable microtensile bond strengths compared with the control group (P>.05). The microtensile bond strengths of Aqua-Prep F, and Cervitec Plus were similar to each other but significantly lower than the control group (P<.05). Bisblock showed the lowest microtensile bond strength among all groups (P<.001). Most groups showed adhesive failure. CONCLUSION. Within the limitation of this study, it is not recommended to use Aqua-prep F, Cervitec Plus and Bisblock on dentin when used with a self-adhesive resin cement due to the decrease they cause in bond strength. Beside, pre-treatment of dentin with Gluma, Smart protect, and Nd:YAG laser do not have a negative effect.

A QUANTITATIVE ANALYSIS ABOUT MICROLEAKAGE OF ALL-IN-ONE ADHESIVES (올인원 접착제의 미세누출에 관한 정량적 분석)

  • Kang, Yong-Hee;Shin, Soo-Il;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.1
    • /
    • pp.66-72
    • /
    • 2004
  • All-in-one adhesives were recently developed for reducing the technique sensitivity and chair time, but lots of concerns were made on bondability, longevity, and microleakage. The object of this study was to evaluate microleakage and marginal quality of all-in-one adhesives using electrochemical method and SEM analysis quantitatively. After making Class V cavities, they were bulk filled with Heliomolar(#A1 after surface treatment with three adhesives: Adper Prompt (Group A), One up bond F (Group O), Xeno III (Group X) Electrical conductivity (microamphere, ${\mu}A$) was checked two times: before and after cavity filling. Percentage of leaky margin was estimated from SEM image (${\times}1,000$). The data were statistically analysed: ANOVA and Paired T test for electrical conductivity, Kruskal-Wallis and Mann-Whitney test for marginal quality, Spearman s rho test for checking of relationships between 2 methods. The result were as follows: 1. There was no difference in microleakage between adhesive systems and every specimen showed some of microleakage after filling. 2. Microleakage was reduced about 70% with composite resin filling. 3. Marginal quality was the best in group A. decreasing among groups in the following order: group O, followed by group X. There were significant differences between group A and group X (p=0.015), and between group 0 and group X (p=0.019). 4. There was no relationship between the microleakage measured by electrochemical method and marginal quality measured by SEM analysis. Within the results of this study, there was no difference in microleakage among groups by electrical conductivity. However, significant difference in marginal quality was seen among groups. It was believed that these dissimilar results might be induced because of their own characteristics. Analysis of microleakage needs various methods for accuracy.

COMPATIBILITY OF SELF-ETCHING DENTIN ADHESIVES WITH RESIN LUTING CEMENTS (자가부식형 상아질접착제와 레진시멘트와의 적합성에 관한 연구)

  • Kim, Do-Wan;Park, Sang-Jin;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.493-504
    • /
    • 2005
  • This study was performed to investigate the compatibility between 4 dentin adhesives and 4 resin luting cements. Dentin adhesives used in this study were All-Bond 2 (Bisco Inc., Schaumbrug, IL, USA), Clearfil SE-Bond (Kuraray Medical Inc, Osaka, Japan), Prompt L-Pop (3M Dental Products, St. Paul, MN, USA), One-Up Bond F (Tokuyama corp., Tokyo, Japan) Resin luting cements used in this study were Choice (Bisco Inc., Schaumbrug, IL, USA), Panavia F (Kuraray Medical Inc, Osaka, Japan), RelyX ARC (3M Dental Products, St. Paul, MN, USA) Bistite II DC (Tokuyama corp., Tokyo, Japan). Combination of each dentin adhesive and corresponding resin cement was made to 16 experimental groups. Flat dentin surfaces was created on mid-coronal dentin of extracted mandibular third molars, then dentin surface was polished with 320-grit silicon carbide abrasive papers. Indirect resin composite block (Tescera, Bisco) was fabricated. Its surface for bonding to tooth was polished with silicon carbide abrasive papers Each dentin adhesive was treated on tooth surface and resin composite overlay were luted with each resin cement. Each bonded specimen was poured in epoxy resin and sectioned occluso-gingivally into 1.0mm thick slab, then further sectioned into $1.0{\times}1.0mm^2$ composite-dentin beams. Microtensile bond strength was tested at a crosshead speed of 1.0mm/min. The data were analysed by one-way ANOVA and Duncan's multiple comparison tests The results of this study were as follows, 2-step self-etching dentin adhesive which has additional bonding resin is more comparison than tests. self-etching dentin adhesive.