• Title/Summary/Keyword: All electric range

Search Result 171, Processing Time 0.026 seconds

The Role of Somatostatin in Nociceptive Processing of the Spinal Cord in Anesthetized Cats

  • Jung, Sung-Jun;Park, Joo-Min;Lee, Jun-Ho;Lee, Ji-Hye;Kim, Sang-Jeong;Kim, Jun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.3 no.4
    • /
    • pp.365-373
    • /
    • 1999
  • Somatostatin (SOM) is one of the major neuropeptides in dorsal root ganglion cells, but its role in spinal nociceptive process has not been well known. In present study we aimed to investigate the effect of SOM on the response of dorsal horn neurons to the various types of peripheral nociceptive stimuli in anesthetized cats. Using carbon-filament microelectrode, the single cell activities of wide dynamic range neurons were recorded from the lumbosacral enlargement after noxious mechanical (squeeze), thermal (radiant heat lamp) and cold (dry ice) stimulation to the receptive field. Sciatic nerve was stimulated electrically to evoke $A\;{\delta}-$ and C-nociceptive responses. SOM analogue, octreotide $(10\;{\mu}g/kg),$ was applied intravenously and the results were compared with those of morphine (2 mg/kg, MOR). Systemic SOM decreased the cellular responses to the noxious heat and the mechanical stimulation, but increased those to the cold stimulation. In the responses to the electric stimuli of sciatic nerve, $A\;{\delta}-nociceptive$ response was increased by SOM, while C-nociceptive response was decreased. On the other hand, MOR inhibited the dorsal horn cell responses to all the noxious stimuli. From the above results, it is concluded that SOM suppresses the transmission of nociceptive heat and mechanical stimuli, especially via C-fiber, while it facilitates those of nociceptive cold stimuli via $A\;{\delta}-fiber$.

  • PDF

Dielectric Properties of $BaTiO_3$ System Ferroelectric Thick Films Doped with $Dy_2O_3$ ($Dy_2O_3$$BaTiO_3$계 강유전체 후막의 유전특성)

  • Noh, Hyun-Ji;Yun, Sang-Eun;Park, Sang-Man;Ahn, Byeong-Lib;Lee, Sung-Gap
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1609-1613
    • /
    • 2007
  • (Ba,Sr,Ca)$TiO_3$ powders, which were prepared by sol-gel method using a solution of Ba-, Sr- and Ca-acetate and Ti iso-propoxide, were mixed with organic vehicle and the BSCT thick films were fabricated by the screen-printing techniques on high purity alumina substrates. The structural and dielectirc properties were investigated for various $Dy_2O_3$ doping contents. As a result of thermal analysis, the exothermic peak was observed at around 670^{\circ}C $ due to the formation of the polycrystalline perovskite phase. All BSCT thick films, sintered at $1420^{\circ}C$ for 2h, showed the typical XRD patterns of perovskite polycrystalline structure and no pyrochlore phase was observed. The average grain size of the specimens decreased with increasing amount of $Dy_2O_3$. The average grain size and thickness of the BSCT specimens doped with 0.1 mol% $Dy_2O_3$ were approximately $1.9{\mu}m$ and $70{\mu}m$, respectively. The relative dielectric constant decreased and dielectric loss increased with increasing amount of $Dy_2O_3$, the values of the BSCT thick films doped with 0.1 mol% $Dy_2O_3$ were 3697 and 0.4% at 1 kHz, respectively. The leakage current densities in all BSCT thick films were less than $10^{-9}A/cm^2$ at the applied electric field range of 0-20 kV/cm.

Effect of Deposition Temperature on Structural and Electrical Properties of Ga-Doped ZnO for Transparent Electrode of Thin Film Solar Cells (박막 태양전지용 투명 전극을 위한 Ga 도핑된 ZnO의 증착 온도에 따른 구조 및 전기 특성 변화)

  • Son, Chang-Sik
    • Korean Journal of Materials Research
    • /
    • v.21 no.3
    • /
    • pp.144-148
    • /
    • 2011
  • We have investigated the structural and optical properties of Ga-doped ZnO (GZO) thin films deposited by RF magnetron sputtering at various deposition temperatures from 100 to $500^{\circ}C$. All the GZO thin films are grown as a hexagonal wurtzite phase with highly c-axis preferred parameter. The structural and electrical properties are strongly related to deposition temperature. The grain size increases with the increasing deposition temperature up to $400^{\circ}C$ and then decreases at $500^{\circ}C$. The dependence of grain size on the deposition temperature results from the variation of thermal activation energy. The resistivity of GZO thin film decreases with the increasing deposition temperature up to $300^{\circ}C$ and then decreases up to $500^{\circ}C$. GZO thin film shows the lowest resistivity of $4.3{\times}10^{-4}\;{\Omega}cm$ and highest electron concentration of $1.0{\times}10^{21}\;cm^{-3}$ at $300^{\circ}C$. The mobility of GZO thin films increases with the increasing deposition temperature up to $400^{\circ}C$ and then decreases at $500^{\circ}C$. GZO thin film shows the highest resistivity of 14.1 $cm^2/Vs$. The transmittance of GZO thin films in the visible range is above 87% at all the deposition temperatures. GZO is a feasible transparent electrode for the application to the transparent electrode of thin film solar cells.

Effects of Electric Stimulation with Static Stretching on Hamstrings Flexibility

  • Song, Won-Min;Seo, Hye-Jeong;Shin, Won-Seob
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.164-168
    • /
    • 2015
  • Purpose: Flexibility has been considered one of the most important goals in rehabilitation. This study aimed to investigate the effect of transcutaneous electrical nerve stimulation (TENS) with the static stretching technique on the flexibility of hamstrings. Methods: Twenty-four subjects (15 men, 9 women) with limited hamstrings flexibility received three different intervention sessions in random order. The treatment sessions included static stretching (SS), static stretching with motor-level TENS (SS with motor TENS) and sensory-level TENS (SS with sensory TENS). All sessions of SS were performed in the straight-leg raise position for 30 seconds followed by rest for 15 seconds, in repetitions for 10 minutes using a belt. The TENS groups underwent TENS stimulation ($40{\mu}s$, 100 Hz) during the stretching for 10 minutes. Outcome measures were evaluated according to active knee extension (AKE) and recorded before the session and at 0, 3, 6, 9, and 15 minutes after the session. Results: There was significant improvement in hamstrings flexibility within all groups (p<0.05). SS with TENS (both sensory and motor) maintained significant increases in knee extension range of motion until 15 minutes post-treatment. In contrast, the SS-only group maintained significantly increased hamstrings flexibility only until 6 minutes post-treatment (p<0.05). Conclusion: Improvement in hamstrings flexibility with SS with TENS was maintained longer than with SS-only intervention. Electrical stimulation with stretching may be more effective than SS alone for increased duration of maintained hamstrings flexibility.

Thrust Performance and Plasma Acceleration Process of Hall Thrusters

  • Tahara, Hirokazu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.262-270
    • /
    • 2004
  • Basic experiments were carried out using the THT-IV low-power Hall thruster to examine the influences of magnetic field shape and strength, and acceleration channel length on thruster performance and to establish guidelines for design of high-performance Hall thrusters. Thrusts were measured with varying magnetic field and channel structure. Exhaust plasma diagnostic measurement was also made to evaluate plume divergent angles and voltage utilization efficiencies. Ion current spatial profiles were measured with a Faraday cup, and ion energy distribution functions were estimated from data with a retarding potential analyzer. The thruster was stably operated with a highest performance under an optimum acceleration channel length of 20 mm and an optimum magnetic field with a maximum strength of about 150 Gauss near the channel exit and with some shape considering ion acceleration directions. Accordingly, an optimum magnetic field and channel structure is considered to exist under an operational condition, related to inner physical phenomena of plasma production, ion acceleration and exhaust plasma feature. A new Hall thruster was designed with basic research data of the THT-IV thruster. With the thruster with many considerations, long stable operations were achieved. In all experiments at 200-400 V with 1.5-3 mg/s, the thrust and the specific impulse ranged from 15 to 70 mN and from 1100 to 2300 see, respectively, in a low electric power range of 300~1300 W. The thrust efficiency reached 55 %. Hence, a large map of the thruster performance was successfully made. The thermal characteristics were also examined with data of both measured and calculated temperatures in the thruster body. Thermally safe conditions were achieved with all input powers.

  • PDF

Effect of Molecular Weights of Polyethyleneimine on the Polyplex Formation with Calf Thymus DNA

  • Cho, Tae-Sub;Jungho Han;Kim, Seog K.;Lee, Jae-Cheol
    • Macromolecular Research
    • /
    • v.12 no.3
    • /
    • pp.276-281
    • /
    • 2004
  • In this study we investigated the spectral properties, including electric absorption, circular and linear dichroism (CD and LD), and fluorescence emission, of DNA in a DNA-branched polyethyleneimine (BPEI) polyplex at various polymer molecular weights (M$\_$w/) and BPEI-amine-to-DNA-phosphate ratios (N/P ratios). All BPEIs exhibited a common N/P dependence in their absorption and CD spectra. At N/P ratios < 1.0, we observed some hyperchromism in the absorption spectrum, red-shifts in CD bands, and decreases in LD intensity and fluorescence intensity of intercalated ethidium. At intermediate N/P ratios, complete collapse of all spectra occurred. As the N/P ratio increased further, the polyplex dissolved in water. From its characteristic CD spectrum obtained under these conditions, we conclude that the DNA exists in a B-like form. The fluorescence and LD intensities never recovered even at high N/P ratios- which indicates that the dissolved polyplex possesses positive charges and the DNA in the polyplex is condensed despite its B-form CD spectrum. The N/P range in which the absorption and CD signals collapsed was wider when the BPEIs M$\_$w/ decreased. In the case where the BPEIs M$\_$w/ was 0.8 k, recovery of the absorption and CD spectral properties at a high N/P ratio was never achieved, which suggests that the molecular weight of the polymer plays an important role in its dissolution at a high N/P ratio.

An Investigation of Characteristics of Chinese Bellflower (Platycodon grandiflorum A.) Cultivated Soil

  • Choi, Jang Nam;Lee, Wang Hyu
    • Korean Journal of Plant Resources
    • /
    • v.31 no.6
    • /
    • pp.660-666
    • /
    • 2018
  • In order to understand the characteristics of soil according to the cultivation environment of Chinese bellflower (Platycodon grandiflorum A.), soil chemical properties of 12 collected soil samples from 6 cultivated fields in Okcheon, Chungbuk province in August. 2017 were analyzed. The soil pH was distributed within the range of 4.61 to 5.25 at all cultivation years and E.C (Electric Conductivity) and T-N (Total Nitrogen) of the cultivation year were not significant. Available $P_2O_5$ was higher than the average for medicinal crops and P. grandiflorum in Korea and C.E.C (Cation Exchange Capacity) was inconsistent for each cultivation year. In particularly, it was validated that the content of exchangeable cations K, Ca, Ma, and Na in this experiment was similar to that of C.E.C according to the cultivation years, because C.E.C had a high correlation with the exchangeable cations. For the available $P_2O_5$, as affected by trans-planting, 5Y-NT-H (cultivated 5 years and non-transplanted) had 58 mg/kg, while 5Y-T-H (cultivated 5 years and transplanted) had 246 mg/kg. The soil pH was found to be lower (acidic) in diseased soils than healthy soils. E.C was confirmed to be was higher in diseased soils than healthy soils except for the one cultivated for 2 years. The contents of T-N and available $P_2O_5$ were higher in diseased soil except for the one cultivated for 5 years and 11 years. The exchangeable cation K and Na tended to be higher in diseased soils rather than that in healthy soils, and the exchangeable cation Ca and Mg contents were higher in healthy soils than in diseased soils. The C.E.C of the soil was lower than that of healthy soils in all of the years except for the one which was cultivated for 5 years (transplanted).

Investigation of Shrinkage around Small Box of Short Span Slab (단경간 슬래브 중앙 소형박스(개구부)주변의 건조수축 거동 조사 연구)

  • Kim, Sang-Yeon
    • Land and Housing Review
    • /
    • v.7 no.4
    • /
    • pp.323-328
    • /
    • 2016
  • There are small box opening for inserting of electric lamp box in the slab of apartment. Around this box opening, we normally use the detailing of WWF or plastic ring strengthening to protect cracks induced by shrinkage. The shrinkage amount of slab box around was measured and analysed in order to consider validity of these strengthening methods and to find out economical alternative. Alternative of strengthening methods are normally used strengthening methods in construction companies, which are WWF strengthening, plastic ring strengthening and no strengthening methods. The shrinkage amount was measured using contact guage at the spot of tip attached around the box on slab of small area unit apartment which have small exclusive area below $59m^2$. Measured data shows that there are no big differences between all the 3 strengthening methods and Measure data range is $-264{\mu}{\varepsilon}{\sim}+216{\mu}{\varepsilon}$. Measured shrinkage is on trend slightly increase till 3~5weeks after removal of forms and then decrease. But amount of shrinkage are very low for all the slabs and there are no probabilities of concrete crack by shrinkage.

Estimating soils properties using NIRS to assess amendments in intensive horticultural production

  • Pena, Francisco;Gallardo, Natalia;Campillo, Carmen Del;Garrido, Ana;Cabanas, Victor Fernandez;Delgado, Antonio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1615-1615
    • /
    • 2001
  • During the past ten years, Near Infrared Spectroscopy has been successfully applied to the analysis of a great variety of agriculture products. Previous works (Morra et al., 1991; Salgo et al., 1998) have shown the potential of this technology for soil analysis, estimating different parameters just with one single scan. The main advantages of NIR applications in soils are the speed of response, allowing the increase of the number of samples analysed to define a particular soil, and the instantaneous elaboration of recommendations for fertilization and soil amendment. Another advantage is to avoid the use of chemical reagents at all, being an environmentally safe technique. In this paper, we have studied a set of 129 soil samples selected from representative glasshouse soils from Southern Spain. The samples were dried, milled, and sieved to pass a 2 mm sieve and then analysed for organic carbon, total nitrogen, inorganic nitrogen (nitrate ammonium), hygroscopic humidity, pH and electrical conductivity in the 1:1 extract. NIR spectra of all samples were obtained in reflectance mode using a Foss NIR Systems 6500 spectrophotometer equipped with a spinning module. Calibration equations were developed for seven analytical parameters (ph, Total nitrogen, organic nitrogen, organic carbon, C/N ratio and Electric Conductivity). Preliminary results show good correlation coefficients and standard errors of cross validation in equations obtained for Organic Carbon, Organic Nitrogen, Total Nitrogen and C/N ratio. Calibrations for nitrates and nitrites, ammonia and electric conductivity were not acceptable. Calibration obtained for pH had an acceptable SECV, but the determination coefficient was found very poor probably due to the reduced range in reference values. Since the estimation of Organic Carbon and C/N ratio are acceptable NIIRS could be used as a fast method to assess the necessity of organic amendments in soils from Mediterranean regions where the low level of organic matter in soils constitutes an important agronomic problem. Furthermore, the possibility of a single and fast estimation of Total Nitrogen (tedious determination by modifications of the Kjeldahl procedure) could provide and interesting data to use in the estimation of nitrogen fertilizer rates by means of nitrogen balances.

  • PDF

Evaluation of Electric Pulp Test (EPT) as a Tool for Measurement of Dentinal Hypersensitivity (상아질 지각과민 측정 도구로서의 전기치수검사에 대한 평가)

  • Kim, Young-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.371-378
    • /
    • 2002
  • In this study, 40 hypersensitive teeth of 19 patients were investigated. The procedures performed were as follows: Before desensitization, EPT at occlusal third of buccal surface was done for the evaluation of pulp vitality and the EPT value was recorded for the reference value. And mechanical and thermal test was executed for the test of hypersensitivity. If the tooth responded to the above tests, we did EPT at the exposed surface, using toothpaste as a electrolite medium and recorded the EPT value at patient's response. After the tests had been done, desensitization procedures with Gluma(R) Desensitizer were performed according to the manufacturer's instructions. After desensitization, the same tests except EPT at occlusal third were repeated. All the 40 teeth responded positive before desensitization and negative after desensitization procedures. The EPT value at occlusal third ranged from 31 to 65 (48.9${\pm}$7.2). Before desensitization 34 teeth responded at EPT value of 2 and the remaining 6 teeth was in the range of 17 to 25. After desensitization all 40 teeth responded from 12 to 27 (19.6${\pm}$3.5). The 6 teeth responded at greater number than 2 before desensitization was in the range of 18 to 23. Within the limitations of this study we can conclude that: When a tooth with dentinal hypersensitivity responds to mechanical and thermal stimulation, the tooth shows very low resistance to electricity at the exposed surface while when a tooth is desensitized and doesn't show respond to mechanical and thermal stimuli, the tooth shows increased level of resistance to electric stimulation at the exposed surface. EPT can be used for the diagnosis of dentinal hypersensitivity. Furthermore EPT will be useful to evaluate the outcome of desensitization procedures. However, EPT is not a valid tool for measuring dentinal hypersensitivity.