• Title/Summary/Keyword: Alkali and Alkaline earth

Search Result 113, Processing Time 0.022 seconds

Lithium Ion Selective Electrode Based on a Synthetic Neutural Carrier (중성운반체를 이용한 리튬이온 선택 전극)

  • Kim, Jae Sang
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.33-39
    • /
    • 1992
  • THF-based crown-4 of 16-membered rings having tetrahydrofuran unit was synthesized by an acid-catalyzed condensation of furan and acetone followed by hydrogenation in an effort to obtain highly elective ionophores for lithium ions. The new ionophore was compared with previously reported ionophores under similar measurement conditions with the same plasticizer, tris(2-ethylhexyl) phosphate in poly(vinyl chloride)(PVC) membrane electrodes. Separate solution method was used to determine relative selectivity coefficients for the electrode. The selectivity coefficients($K_{LiM}^{POT}$) of lithium over ammonium, alkali and alkaline earth metal ions go from about $2.4{\times}10^{-1}$ to $2.3{\times}10^{-4}$ to working range and pH dependence have also been studied.

  • PDF

The Potentiometric Performances of Membrane Electrodes Based on Tetracycline Antibiotics (테트라싸이크린 항생제를 담체로 이용한 막전극의 전위차 특성)

  • Baek, Jong-Gyu;Rhee, In-Sook;Paeng, Ki-Jung
    • Journal of the Korean Electrochemical Society
    • /
    • v.9 no.3
    • /
    • pp.132-134
    • /
    • 2006
  • The main component governing selectivity in ion-selective electrodes and optodes is the ionophore. For this reason, a member of natural products that possess selective ion-binding properties have long been sought after. By applying this principle, the performance of tetracycline used as neutral carriers for cation selective polymeric membrane electrode was investigated. The cation ion-selective electrode based on tetracycline gave a good Nernstian response of 26.6 mV per decade for calcium ion in the activity range $1x10^{-6}M$ to $1x10^{-2}M$ with and without lipophilic additives. The optimized cation ion-selective membrane electrodes displayed very comparable potentiometric responses to various mono and di-valent cations of alkali and alkaline earth metal ions except $Mg^{2+}$.

A New Cone Shaped Asymmetrically Substituted Calix[4]arene as an ExcellentIonophore in Construction of Ag(I) ion-Selective Membrane Electrode

  • Ganjali, Mohammad Reza;Babaei, Leila Hajiagha;Taghvaei-Ganjali, Saeed;Modjallal, Atoosa;Sahmsipur, Mojtaba;Hosseini, Morteza;Javanbakht, Mehran
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.2
    • /
    • pp.177-181
    • /
    • 2004
  • A PVC membrane electrode for silver ion based on a new cone shaped calix[4]arene (CASCA) as membrane carrier was prepared. The electrode exhibits a Nernstian response for $Ag^+$ over a wide concentration range ($1.0{\times}10^{-1}-8.0{\times}10^{-6}$M) with a slope of 58.2 {\pm}$ 0.5 mV per decade. The limit of detection of the sensor is $5.0{\times}10^{-6}$M. The sensor has a very fast response time (~5 s) in the concentration range of ${\leq}=1.0{\times}10^{-3}$ M, and a useful working pH range of 4.0-9.5. The proposed sensor displays excellent discriminating ability toward $Ag^+$ ion with respect to common alkali, alkaline earth, transition and heavy metal ions. It was used as an indicator electrode in potentiometric titration of $Ag^+$ with EDTA and in direct determination of silver ion in wastewater of silver electroplating.

UO22+ Ion-Selective Membrane Electrode Based on a Naphthol-Derivative Schiff's Base 2,2'-[1,2-Ethandiyl bis(nitriloethylidene)]bis(1-naphthalene)

  • Shamsipur, Mojtaba;Saeidi, Mahboubeh;Yari, Abdullah;Yaganeh-Faal, Ali;Mashhadizadeh, Mohammad Hossein;Azimi, Gholamhasan;Naeimi, Hossein;Sharghi, Hashem
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.629-633
    • /
    • 2004
  • A new PVC membrane electrode for $UO_2^{2+}$ ion based on 2,2'-[1,2-ethanediyl bis (nitriloethylidene)]bis(1-naphthalene) as a suitable ionophore was prepared. The electrode exhibites a Nernstian response for $UO_2^{2+}$ ion over a wide concentration range ($1.0{\times}10^{-1}-1.0{\times}10^{-7}$M) with a slope of 28.5 ${\pm}$ 0.8 mV/decade. The limit of detection is $7.0{\times}10^{-8}$M. The electrode has a response time of < 20 s and a useful working pH range of 3-4. The proposed membrane sensor shows good discriminating abilities towards $UO_2^{2+}$ ion with regard to several alkali, alkaline earth transition and heavy metal ions. It was successfully used to the recovery of uranyl ion from, tap water and, as an indicator electrode, in potentiometric titration of $UO_2^{2+}$ ion with Piroxycam.

La(III) Selective Membrane Sensor Based on a New N-N Schiff's Base

  • Ganjali, Mohammad Reza;Matloobi, Parisa;Ghorbani, Maryam;Norouzi, Parviz;Salavati-Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.1
    • /
    • pp.38-42
    • /
    • 2005
  • Bis(2-methylbenzaldehyde)butane-2,3-dihydrazone(TDSB) was used as new N-N Schiff's base which plays the role of an excellent ion carrier in the construction of a La(III) membrane sensor. The best performance was obtained with a membrane containing, 30% poly(vinyl chloride), 60% benzyl acetate, 6% TDSB and 4% sodium tetraphenyl borate. This sensor reveals a very good selectivity towards La(III) ions over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The proposed electrode exhibits a Nernstian behavior (with slope of 19.8 mV per decade) over a wide concentration range (1.0 ${\times}$ 10$^{-5}$-1.0 ${\times}$ 10$^{-1}$ M). The detection limit of the sensor is 7.0 ${\times}$ 10$^{-6}$ M. It has a very short response time, in the whole concentration range ($\sim$5 s), and can be used for at least twelve weeks in the pH range of 3.0-9.4. The proposed sensor was successfully applied as an indicator electrode for the potentiometric titration of a La(III) solution, with EDTA. It was also successfully applied in the determination of fluoride ions in three mouth wash preparations.

Novel Copper(Ⅱ)-Selective Senor Based on a New Hexadentates Schiff's Base

  • Ganjali, Mohammad Reza;Emami, Mehdi;Salavati Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.10
    • /
    • pp.1394-1398
    • /
    • 2002
  • A novel copper(II) membrane electrode based on diphenylisocyanate bis(acetylacetone) ethylenediimine (DIBAE), as a new hexadentates Schiff's base was prepared. The electrode exhibited a Nernstian response for Cu$^{2+}$ ions over a wide concentration range (1.0 ${\times}$ 10$^{-1}$ to 1.0 ${\times}$ l0$^{-6}$ M) with a limit of detection of 6.0 ${\times}$ 10$^{-7}$ M (39 ppb). The sensor shows a fast response time (15s) and the membrane can be used for more than 4 months without observing any major deviation. The electrode revealed very good selectivity with respect to many cations including alkali, alkaline earth, transition and heavy metal ions. The proposed sensor could be used in a pH range of 3.0-7.5. It was applied to the direct potentiometric determination of copper in black tea, and in wastewater of copper electroplating samples. The electrode was also used in potentiometric titration of the copper(II) ion with EDTA.

Cesium Ion-Selective Electrode Based on Upper-rim Calix[4]crown Ionophore (캘릭스 [4]크라운 유도체를 이온선택성 물질로 사용한 세슘이온 선택성 막전극)

  • Namgung, Miok;Ihm, Hyejae;Paek, Kyungsoo;Yun, Youngja
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.428-432
    • /
    • 2000
  • A PVC membrane electrode based on upper-rim calix[4]crown as ionophore was prepared using dioctyl sebacate (DOS) as a plasticizer. The potential response of this membrane electrode to alkali, alkaline earth metal cations were examined. This membrane electrode exhibited a Nemstian response to $10^{-5}-10^{-1}M$ of CsCI with a slope of 52.3 mV/decade in Tris-buffer(pH 7.20). Its response time ($t_{90%}$) was 10s and it could be used for at least 2 months.

  • PDF

Hg(II) ion- Selective Electrodes with Neutral Carriers of Macrocycles (거대고리 중성 운반체를 갖는 Hg(II)이온 선택성 전극)

  • 정오진
    • Journal of Environmental Science International
    • /
    • v.5 no.2
    • /
    • pp.211-220
    • /
    • 1996
  • New thin-and diselena-crown ethers containing two suffer and selenium donor atoms have been prepared. And then, mercury ($Hg^{2+}$) ion-selective electrodes with PVC-plasticizer (STPB) based on some macrocycles as neutral carriers were also made. The electrochemical selectivities for various ions, and the effects for macrocycles, matrix of membranes, ratio of plasticizer to macrowcles, concentration and pH of test solution were investigated on the $Hg^{2+}$ ion-selective electrodes. The 1, 10-diselena-18-crown-6-PVC-STPB (sodium tetraphenylborate) exhibited good linear responses of ${28.2}\pm{0.6}$ decade-1 for $Hg^{2+}$ ion in the conientration ranges of $10^{-2}~10^{-6}$ M $Hg^{2+}$ ion. This electrode exhibited comparatively good selectivities for $Hg^{2+}$ ion in comparison with alkali and alkaline earth metal ions, some heavy metal ions and rare earth metal ion in the range of pH 2.5~6.0. In addition, this electrode was applied as a sensor in the titration of $Hg^{2+}$ ion with $1^-$ ion in water.

  • PDF

Petrology on the Late Miocene Basalts in Goseong-gun, Gangwon Province (강원도 고성군 일대의 후기 마이오세 현무암의 암석학적 연구)

  • Koh Jeong Seon;Yun Sung-Hyo
    • Journal of the Korean earth science society
    • /
    • v.26 no.1
    • /
    • pp.78-92
    • /
    • 2005
  • Petrographical and petrochemical analyses for late Miocene basalts in Goseong-gun area. Gangwon province, were carried out to interpret the characteristics and the origin of magma. The basaltic rocks occurred as plug-dome in the summit of several small mountain and developed columnar jointing with pyroxene-megacryst bearing porphyritic texture. And the basalt contains xenoliths of biotite granite (basement rocks), gabbro (lower crustal origin) and Iherzolite(upper mantle origin). The basalts belong to the alkaline basalt field in TAS diagram and partly belong to picrobasalt and trachybasalt field. On the tectonomagmatic discrimination diagram f3r basalt in the Goseong-gun area. they fall into the fields for the within plate and oceanic island basalt. The characteristics of trace elements and REEs shows that primary magma for the basalt magma would have been derived from partial melting of garnet-peridotite mantle. This late Miocene basalt volcanism is related to the hot spot within the palte.

Petrology of the Syenites in Hapcheon, Korea (경남 합천 지역의 섬장암에 관한 암석학적 연구)

  • Ok, Eun-Young;Kim, Jong-Sun;Lee, Sang-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.13-43
    • /
    • 2017
  • In the Hapcheon area, hypersthene-bearing monzonite (mangerite) and syenite are recognized. The main minerals of syenite are alkali feldspar, plagioclase, amphibole, biotite, and quartz. Anhedral hornblende and biotite are interstitial between feldspar and quartz, indicating that the hydrous minerals were crystallized later on. Based on petrochemical studies of major elements, syenite is alkaline series, metaluminous, and I-type. The variation patterns in the trace and rare earth elements of mangerite and syenite show the features of subduction-related igneous rock such as depletion of HFSE, relative enrichment in LILE to LREE, and negative Nb-P-Ti anomalies. Based on the experimental data and petrographic characteristics of the syenite, Hapcheon syenitic magma is considered to be formed by partial melting in a dry system. SHRIMP U-Pb zircon data yield the Triassic age as $227.4{\pm}1.4Ma$ in mangerite, $215.3{\pm}1.2Ma$ in syenite, and $217.9{\pm}2.6Ma$ in coarse-grained syenite, respectively. The mangerite age is similar to those of post-collisional plutonic rocks in Hongseong (226~233 Ma), Yangpyeong (227~231 Ma), and Odaesan (231~234 Ma) areas in the Gyeonggi Massif. Syenites were intruded after about 10 Ma. The features seen in the mangereite and syenite rocks can be explained by models such as the continental collision and slab break-off and the lithosphere thinning and asthenosphere upwelling model.