DOI QR코드

DOI QR Code

The Potentiometric Performances of Membrane Electrodes Based on Tetracycline Antibiotics

테트라싸이크린 항생제를 담체로 이용한 막전극의 전위차 특성

  • Published : 2006.08.01

Abstract

The main component governing selectivity in ion-selective electrodes and optodes is the ionophore. For this reason, a member of natural products that possess selective ion-binding properties have long been sought after. By applying this principle, the performance of tetracycline used as neutral carriers for cation selective polymeric membrane electrode was investigated. The cation ion-selective electrode based on tetracycline gave a good Nernstian response of 26.6 mV per decade for calcium ion in the activity range $1x10^{-6}M$ to $1x10^{-2}M$ with and without lipophilic additives. The optimized cation ion-selective membrane electrodes displayed very comparable potentiometric responses to various mono and di-valent cations of alkali and alkaline earth metal ions except $Mg^{2+}$.

본 연구에서는 테트라싸이크린 항생제를 양이온선택성 전극의 담체로 사용한 막전극을 제작하고 알칼리 및 알칼리 토금속에 적용하여 전위차 감응도를 조사하였다. 제작된 전극은 지용성 첨가제의 유무와 관계없이 $Ca^{2+}$ 이온에 대해서 거의 이상적인 전위차 감응도를 나타내었다. 또한 $Mg^{2+}$를 제외한 다른 양이온에도 이상적인 네른스트값에 80% 이상의 감응도와 $10^{-5}$ 이하의 검출한계를 나타내었다. 수명, 감응시간, 재현성 등도 이온선택성 전극에 응용하기에 문제가 없었다.

Keywords

References

  1. R. W. Cattrall, 'Ion-Selective Electrode Rev.', Petgamon Press, New York, (1984)
  2. E. Bakker, P. Buhlmann, and E. Pretsch, Chem. Rev. 97, 3083 (1997) https://doi.org/10.1021/cr940394a
  3. P. Buhlmann, E. Pretsch, and E. Bakker, Chem. Rev. 98, 1593 (1998) https://doi.org/10.1021/cr970113+
  4. R. J. Dancer, A. Jones, and D. P. Fairlie, Aust. J. Chem., 48, 1835 (1995) https://doi.org/10.1071/CH9951835
  5. K. Suzuki, K. Kohda, H. Aruga, M. Matsuzoe, H. Inoue, and T. Shirai, Anal. Chem., 60, 1714 (1988) https://doi.org/10.1021/ac00161a010
  6. H. M. Burger and D. Seebach, Angew. Chem. Int., 33, 442 (1994) https://doi.org/10.1002/anie.199404421
  7. M. Schafer, G M. Sheldrick, I. Bahner, and H. Lackner, Angew. Chem. int., 37, 2391 (1998)
  8. L. C. M. Ngoka and M. L. Gross, J. Mass Spectrom., 35, 265 (2000) https://doi.org/10.1002/(SICI)1096-9888(200002)35:2<265::AID-JMS946>3.0.CO;2-#
  9. O. Scholz, P. Schubert, M. Kintrup, and W. Hillen, Biochemistry, 39, 10914 (2000) https://doi.org/10.1021/bi001018p
  10. Y. Umezawa, K. Urnezawa, and H. Sato, Pure Appl. Chem. 67, 507 (1995) https://doi.org/10.1351/pac199567030507
  11. O. J. Palm, D. Dalrn, N. Mettews, J. Proft, and W. Hinrichs, www-hasylab. desy.de/science/annual_reports/2005_report
  12. I. R. Paeng, Anal. Sci. & Tech, 18(6), 491 (2005)

Cited by

  1. The Potentiometric Performances of the Cation Selective Electrodes based on Tetracycline and Chemically Modified Tetracycline vol.2, pp.3, 2011, https://doi.org/10.5229/JECST.2011.2.3.143
  2. Electrochemical biosensors in pharmaceutical analysis vol.46, pp.3, 2010, https://doi.org/10.1590/S1984-82502010000300002