• 제목/요약/키워드: Alignment method

Search Result 1,265, Processing Time 0.024 seconds

The New Radiographic Evaluation of Hindfoot Alignment (후족부 정렬의 새로운 방사선학적 평가 방법)

  • Han, Woo-Yeon;Lee, Ho-Seong;Kim, Won-Kyeong;Ahn, Ji-Yong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.3
    • /
    • pp.169-174
    • /
    • 2012
  • Purpose: There are various methods proposed for the evaluation of the hindfoot alignment. However, due to structural calcaneus variances between patients, it is hard to assess this alignment definitively. Thus, this study proposes a new method for evaluating of the hindfoot alignment and its comparisons to the existing current methods. Materials and Methods: This study includes simple weight bearing hindfoot coronal view radiographs of 120 patients, taken between the time period of March 2008 to November 2009. Among the 120 patients, there was a 1:1 ratio of male to female with an average age of 40. The newly proposed method for evaluating this alignment is to draw a moment arm from the point where the sustentaculum tali meets the medial calcaneus border to the most prominent aspect of the lateral process of the calcaneal tuberosity. The angle produced via the intersection of this moment arm to the mid-longitudinal axis of the tibia is found and used to evaluate the hindfoot alignment. The inter and intra-observer reliability was evaluated using the coefficient of intraclass correlation. This study also investigates the comparisons between the newly proposed method to the traditionally used Saltzman et al hindfoot alignment evaluating technique. Results: The newly proposed method has higher inter and intra-observer reliability than the existing traditional Saltzman et al technique. Conclusion: This new method is recommended over the traditionally used Saltzman et al technique as it has a stronger confidence level and is appropriate for assessing hindfoot alignment in simple radiographs.

Measurement Time-Delay Error Compensation for Transfer Alignment (전달정렬의 측정치 시간지연 오차보상 기법)

  • Lim, You-Chol;Song, Gi-Won;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.11
    • /
    • pp.953-957
    • /
    • 2001
  • This paper is concerned with a transfer alignment method for the SDINS under ship motions. Major error sources of transfer alignment are data transfer time-delay, lever-arm velocity and ship body flexure. Specifically, to reduce alignment errors induced by measurement time-delay effects, the error compensation method through delay state augmentation is suggested. A linearized error model for the velocity and attitude matching transfer alignment system is first derived by linearizing the nonliner measurement equation with respect to its time delay and augmenting the delay state into the conventional linear state equations. And then it is shown via observability analysis and computer simulations that the delay state can be estimated and compensated during ship motions resulting in considerably less alignment errors.

  • PDF

Method for tool alignment error Compensation of Angle controlled Ultra-Precision machining (각도 제어 초정밀 가공기의 공구 위치 검출)

  • Park, Soon-Sub;Lee, Ki-Young;Kim, Hyoung-Mo;Lee, Jae-Seol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.3
    • /
    • pp.53-57
    • /
    • 2007
  • This paper presents a geometrical error compensation of tool alignment for B axis controlled machine. In precision machining, tool alignment is crucial parameter for machined surface. To decrease tool alignment error, plus tilted tool from B axis center is touched to reference work piece and checked the deviation from original position. Same process is performed in minus tilt. Comparing these 2 touch positions, wheel alignment error in X axis and Z axis can be calculated on B axis center. Experimental results show that this compensation method is efficient to correct tool alignment.

  • PDF

Liquid Crystal Alignment Effects using a DLC Thin Film (DLC 박막을 이용한 액정 배향 효과)

  • Jo, Yong-Min;Hwang, Jeoung-Yeon;Seo, Dae-Shik;Rho, Soon-Joon;Lee, Dae-Kyu;Baik, Hong-Koo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.346-349
    • /
    • 2001
  • We studied the nematic liquid crystal (NLC) aligning capabilities using the new alignment material of diamond like carbon (DLC) thin film. A high pretilt angle of about $4^{\circ}$ was measured by ion beam(IB) exposure on the DLC thin film surface. A good LC alignment was observed by the IB alignment method on the DLC thin film surface at annealing temperature of $200^{\circ}C$, and the alignment defect of the NLC was observed above annealing temperature of $220^{\circ}C$. Consequently, the high NLC pretilt angle and the good thermal stability of LC alignment can be achieved by the IB alignment method on the DLC thin film surface.

  • PDF

LC Alignment Effects using a-C:H Thin Film as Working Gas at Bias Condition (바이어스 조건하에서 증착한 a-C:H 박막을 이용한 액정배향 효과)

  • 황정연;조용민;서대식;노순준;백홍구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.11
    • /
    • pp.1019-1022
    • /
    • 2003
  • We studied the nematic liquid crystal (NLC) aligning capabilities using the new alignment material of a-C:H thin film as working gas at 30W rf bias condition. A high pretilt angle of about 5$^{\circ}$ by ion beam(IB) exposure on the a-C:H thin film surface was measured. A good LC alignment by the IB alignment method on the a-C:H thin film surface was observed at annealing temperature of 250$^{\circ}C$, and the alignment defect of the NLC was observed above annealing temperature of 300$^{\circ}C$. Consequently, the high LC pretilt angle and the good thermal stability of LC alignment by the IB alignment method on the a-C:H thin film surface as working gas at 30W rf bias condition can be achieved.

Liquid Crystal Alignment Effects using a DLC Thin Film (DLC 박막을 이용한 액정 배향 효과)

  • 조용민;황정연;서대식;노순준;이대규;백흥구
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.346-349
    • /
    • 2001
  • We studied the nematic liquid crystal (NLC) aligning capabilities using the new alignment material of diamond like carbon (DLC) thin film. A high pretilt angle of about 4$^{\circ}$ was measured by ion beam(IB) exposure on the DLC thin film surface. A good LC alignment was observed by the IB alignment method on the DLC thin film surface at annealing temperature of 200$^{\circ}C$, and the alignment defect of the NLC was observed above annealing temperature of 220$^{\circ}C$ . Consequently, the high NLC pretilt angle and the good thermal stability of LC alignment can be achieved by the IB alignment method on the DLC thin film surface.

  • PDF

Liquid crystal alignment and EO performance of transcription-aligned TN-LCD (전사배향 TN-LCD의 액정배향 및 전기광학특성)

  • 서대식;김진호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.12
    • /
    • pp.1133-1138
    • /
    • 1998
  • In this paper, we obtained the monodomain alignment of nematic liquid Crystal(NLC) in the cell fabricated by transcription alignment method on polyimide(PI) surface with side chain. It is considered that the LC alignment produced by the transcription alignment method is attributed to a memory effect of the NLC on PI surfaces. Also we observed that the generated pretilt angle of NLC is about $3.7^{\circ}$ with transcription alignment on PI surface. Next, we measured that the voltage-transmittance characteristics of transcription-aligned TN-LCD are almost same compared to rubbing-aligned TN-LCD. Also, we measured that the curve of transcription-aligned TN-LCD is less sharp than that of the rubbing-aligend TN-LCD in the decay time characteristics. It is considered that the response time characteristics of transcription-aligned TN-LCD are attributed to the weak anchoring strength between the LC molecules and the polymer surface.

  • PDF

Liquid Crystal Alignment Effects using a Diamond-like Carbon Thin Film (Diamond-like Carbon 박막을 이용한 액정 배향 효과)

  • 황정연;조용민;서대식;노순준;이대규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.5
    • /
    • pp.419-422
    • /
    • 2002
  • We studied the nematic liquid crystal (NLC) aligning capabilities using the new alignment material of a diamond like carbon (DLC) thin film. A high pretilt angle of about $3.5^{\circ}$ by ion beam(IB) exposure on the DLC thin film surface was measured. A good LC alignment by the IB alignment method on the DLC thin film surface was observed at annealing temperature of $200^{\circ}C$, and the alignment defect of the NLC was observed above annealing temperature of $220^{\circ}C$. Consequently, the high NLC pretilt angle and the good thermal stability of LC alignment by the IB alignment method on the DLC thin film surface can be achieved.

Liquid crystal alignment effects by imidization methods of the polyimide on the polymer with side chain. (측쇄기를 가진 폴리머의 폴리이미드 소성 방법에 따른 액정 배향 효과)

  • Seo, Dae-Shik;Kim, Hyung-Kyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.177-180
    • /
    • 2000
  • In this study, we investigated the pretilt angle generation and liquid crystal (LC) alignment by ultraviolet (UV) exposure during imidization of polyimide on the polymer with side chain. The generated pretilt angle of nematic (N) LC using in-situ photo-alignment method was smaller than that of the conventional UV photo-alignment method. Also, the generated pretilt angle of NLC tends to increase by annealing.

  • PDF

Application of GPS Surveying for Extracting Highway's Horizontal Alignment

  • Seo, Jeong-Hoon;Roh, Tae-Ho;Lee, Jong-Chool
    • Korean Journal of Geomatics
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • Korea is a small country with relatively large mountainous areas and has many difficulties from planning to completing one road. Maintaining a completed road presents even more difficulties. presently, in estimating design elements, the result varies according to the engineer and there are many cases that question the reliability of the results. Therefore, in this study, the alignment of highway was sampled using by the centerline path, the design elements of horizontal alignment were reduced by applying the Least Squares Method, and the accuracy was analyzed. By this method, IP, IA, R, $\Delta$R and A-parameter were also determined. By observing relatively long straight sections, the approximate values could be estimated, and particularly, the considerably accurate value of A-parameter was determined. This study, using the Least Squares Method, aims to contribute to the development of the alignment examination in frequent traffic accident regions.

  • PDF