• Title/Summary/Keyword: Alignment and leveling

Search Result 18, Processing Time 0.017 seconds

In-Flight Alignment of SDINS without Initial Heading Information (초기 기수각 정보가 필요 없는 SDINS의 운항중 정렬)

  • 홍현수;이장규;박찬국
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.6
    • /
    • pp.524-532
    • /
    • 2002
  • This paper presents a new in-flight alignment method for an SDINS under large initial heading error. To handle large heading error, a new attitude error model is introduced. The attitude errors are divided into heading error and leveling errors using a newly defined horizontal frame. Some navigation error dynamic models are derived from the attitude error model for indirect feedback filtering of the in-flight alignment system. A Kalman filter with Position measurement is designed to estimate navigation errors as the indirect feedback filter Simulation results show that the proposed in-flight alignment method reduces the heading error very quickly from more than 40deg to about 5deg so as to apply a refined navigation filter. The total alignment process including leveling mode and navigation mode in addition to the proposed one allows large initial values not only in heading error but also in leveling errors.

Influence of Plate Design on the Accuracy of Tibial Alignment after Center of Rotation of Angulation-Based Leveling Osteotomy in Toy-Breed Dogs

  • Han, Jae-Hong;Lee, Hae-Beom;Jeong, Jae-Min;Jeon, Young-Jin;Roh, Yoon-Ho
    • Journal of Veterinary Clinics
    • /
    • v.39 no.3
    • /
    • pp.100-106
    • /
    • 2022
  • The center of rotation of angulation-based leveling osteotomy (CBLO) has been introduced for the stabilization of cranial cruciate ligament rupture (CCLR) in small-breed dogs. This technique can be applied to the tibia without damaging its tuberosity. Although different designs of CBLO plates are available, tibial plateau leveling osteotomy (TPLO) plates have been still used for stabilization during CBLO. To the best of our knowledge, no studies have reported the effects of TPLO plates on the postoperative limb alignment after CBLO. Therefore, the present study (January 2020 to February 2021) aimed to compare the postoperative outcomes (postoperative tibial plateau angle [TPA] and tibial alignment) in patients receiving CBLO and TPLO plates during CBLO. Paired stifle joints (n = 16) were obtained from eight toy-breed cadaver dogs (mean weight, 4.4 kg) that underwent CBLO. The joints were randomly assigned to receive the CBLO (CBLO group) or TPLO plates (TPLO group). Pre-and postoperative radiographs were obtained, and the dissected tibiae were evaluated. The following postoperative parameters were compared to evaluate the surgical outcome: TPA, osteotomy location, mechanical medial proximal tibia angle, inter-segment gap, and tibial plateau translation. No significant differences were found in the postoperative alignment between the two groups. Therefore, TPLO plates may be considered as a viable alternative in toy-breed dogs undergoing CBLO.

ROOT SURFACE CHANCES DURING THE INITIAL LEVELING AND ALIGNMENT PHASE IN ORTHODONTICS: A SCANNING ELECTRON MICROSCOPIC STUDY (교정적 치아초기배열단계시 발생하는 치근 변화에 관한 주사전자현미경적 연구)

  • Choi, Jung-Yoon;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.591-600
    • /
    • 1998
  • The purpose of this study was to investigate the root resolution and repair pattern of human teeth according to the force magnitude, direction and duration during the initial leveling and alignment phase. 40gms to 500gms of force applied to the 37 experimental teeth with duration of 3 weeks to 7 months. Then, the experimental teeth were extracted. 13 control teeth were extracted without treatment. The results are as follows: 1. $59.5\%$ of 37 teeth exhibited root resorption. The initial resorption site was visible at the apex within 3 weeks with 100 gms samples, and the initial repair site was visible at the apex within 3 months with 400 gms samples. 2. Number of resorbed teeth increased with the duration of the force. 3. The depth of the resorption increased with the magnitude of the force. 4. The areas of resorbed root corresponded with the loading pattern. 5. The areas of resorbed root were highly correlated with the magnitude of the force. The result of this study suggest that root resorption could occur during the initial leveling and alignment phase, These initial injuries are all small and insignificant. It is the extensive type of apical root resolution that must be regarded as deleterious to the function and stability of the tooth moved. During the initial leveling and alignment phase lighter force of the interrupted type and short treatment period would be favorable with regard to avoidance of root resorption and repair of resorbed root surface.

  • PDF

Error Analysis of Initial Fine Alignment for Non-leveling INS (경사각을 갖는 관성항법시스템 초기 정밀정렬의 오차 분석)

  • Cho, Seong-Yun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.6
    • /
    • pp.595-602
    • /
    • 2008
  • In this paper, performance of the initial alignment for INS whose attitude is not leveled is investigated. Observability of the initial alignment filter is analyzed and estimation errors of the estimated state variables are derived. First, the observability is analyzed using the rank test of observability matrix and the normalized error covariance of the Kalman filter based on the 10-state model. In result, it can be seen that the accelerometer biases on horizontal axes are unobservable. Second, the steady-state estimation errors of the state variables are derived using the observability equation. It is verified that the estimates of the state variables have errors due to the unobservable state variables and the non-leveling tilt angles of a vehicle containing the INS. Especially, this paper shows that the larger the tilt angles of the vehicle are, the larger the estimation errors corresponding to the sensor biases are. Finally, it is shown that the performance of the 8-state model excepting the accelerometer biases on horizontal axes is better than that of the 10-state model in the initial alignment by simulation.

Frictional property comparisons of conventional and self-ligating lingual brackets according to tooth displacement during initial leveling and alignment: an in vitro mechanical study

  • Kim, Do-Yoon;Lim, Bum-Soon;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.46 no.2
    • /
    • pp.87-95
    • /
    • 2016
  • Objective: We evaluated the effects of tooth displacement on frictional force when conventional ligating lingual brackets (CL-LBs), CL-LBs with a narrow bracket width, and self-ligating lingual brackets (SL-LBs) were used with initial leveling and alignment wires. Methods: CL-LBs (7th Generation), CL-LBs with a narrow bracket width (STb), and SL-LBs (In-Ovation L) were tested under three tooth displacement conditions: no displacement (control); a 2-mm palatal displacement (PD) of the maxillary right lateral incisor (MXLI); and a 2-mm gingival displacement (GD) of the maxillary right canine (MXC) (nine groups, n = 7 per group). A stereolithographic typodont system and artificial saliva were used. Static and kinetic frictional forces (SFF and KFF, respectively) were measured while drawing a 0.013-inch copper-nickel-titanium archwire through brackets at 0.5 mm/min for 5 minutes at $36.5^{\circ}C$. Results: The In-Ovation L exhibited lower SFF under control conditions and lower KFF under all displacement conditions than the 7th Generation and STb (all p < 0.001). No significant difference in SFF existed between the In-Ovation L and STb for a 2-mm GD of the MXC and 2-mm PD of the MXLI. A 2-mm GD of the MXC produced higher SFF and KFF than a 2-mm PD of the MXLI in all brackets (all p < 0.001). Conclusions: CL-LBs with narrow bracket widths exhibited higher KFF than SL-LBs under tooth displacement conditions. CL-LBs and ligation methods should be developed to produce SFF and KFF as low as those in SL-LBs during the initial and leveling stage.

KrF 엑시머 레이저를 이용한 웨이퍼 스텝퍼의 제작 및 성능분석

  • 이종현;최부연;김도훈;장원익;이용일;이진효
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.15-21
    • /
    • 1993
  • This paper describes the design and development of a KrF excimer laser stepper and discusses the detailed system parameters and characterization data obtained from the performance test. We have developed a deep UV step-and-repeat system, operating at 248 nm, by retrofitting a commercial modules such as KrF excimer laser, precision wafer stage and fused silica illumination and 5X projection optics of numerical aperture 0.42. What we have developed, to the basic structure, are wafer alignment optics, reticle alignment system, autofocusing/leveling mechanisms and environment chamber. Finally, all these subsystem were integrated under the control of microprocessor-based controllers and computer. The wafer alignment system comprises the OFF-AXIS and the TTL alignment. The OFF-AXIS alignment system was realized with two kinds of optics. One is the magnification system with the image processing technique and the other is He-Ne laser diffraction type system using the alignment grating on the wafer. 'The TTL alignment system employs a dual beam inteferometric method, which takes advantages of higher diffraction efficiency compared with other TTL type alignment systems. As the results, alignment accuracy for OFF-AXIS and TTL alignment system were obtained within 0.1 $\mu\textrm{m}$/ 3 $\sigma$ for the various substrate on the wafers. The wafer focusing and leveling system is modified version of the conventional systems using position sensitive detectors (PSD). This type of detection method showed focusing and leveling accuracies of about $\pm$ 0.1 $\mu\textrm{m}$ and $\pm$ 0.5 arcsec, respectively. From the CD measurement, we obtained 0.4 $\mu\textrm{m}$ resolution features over the full field with routine use, and 0.3 $\mu\textrm{m}$ resolution was attainable under more strict conditions.

  • PDF

Effects of single-dose, low-level laser therapy on pain associated with the initial stage of fixed orthodontic treatment: A randomized clinical trial

  • Qamruddin, Irfan;Alam, Mohammad Khursheed;Abdullah, Habiba;Kamran, Muhammad Abdullah;Jawaid, Nausheen;Mahroof, Verda
    • The korean journal of orthodontics
    • /
    • v.48 no.2
    • /
    • pp.90-97
    • /
    • 2018
  • Objective: The aim of this study was to assess the analgesic effect of a single application of low-level laser therapy (LLLT) on spontaneous pain and pain on chewing after placement of initial archwires. Methods: Forty-two patients (26 women, 16 men) were randomly recruited for this split-mouth randomized clinical trial. Each patient received super-elastic nickel-titanium (NiTi) initial archwires (0.012, 0.014, 0.016, and 0.018-inch [in]) in the maxilla for leveling and alignment for an interval of 4 weeks between archwires. One side of the mouth was randomly designated as experimental, while the other side served as placebo. After insertion of each archwire, the experimental side was irradiated with a diode laser for 3 seconds each on 5 points facially and palatally per tooth, from the central incisor to first molar. On the placebo side, the laser device was held the same way but without laser application. A numerical rating scale was used to assess the intensity of spontaneous and masticatory pain for the following 7 days. The Mann-Whitney U test was used to compare pain scores between sides. Results: Patients in the LLLT group exhibited significantly lower mean scores for spontaneous pain after insertion of the initial two archwires (0.012-in and 0.014-in NiTi; p < 0.05), while there was no significant difference for 0.016-in and 0.018-in wires between the LLLT and placebo groups. LLLT significantly reduced chewing pain scores (p < 0.05) for all archwires. Conclusions: A single dose of LLLT considerably lessened postoperative pain accompanying the placement of super-elastic NiTi wires for initial alignment and leveling.

Arrayed Tip based Pattern Lithography with Built-in Capacitive Proximal Leveling Sensor (내장형 정전용량 근접 센서를 이용한 다중 팁 기반 패턴 인쇄)

  • Han, Yoonsoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.5
    • /
    • pp.239-245
    • /
    • 2019
  • To increase the throughput of tip-based nanolithography (TBN), one approach is to use a large array of such tips working in parallel. It is important to maintain co-planarity between the tip array and the writing surface. A slight misalignment can cause large discrepancies of contact force and feature sizes. We report a capacitive proximity sensor built-in with the TBN array for leveling an arrayed polymer pen array. The device allows alignment between an array of writing tips and the writing substrate without contact and contamination. The angular sensitivity of the sensor is $0.05^{\circ}$ for an array with maximum tip-to-tip separation of 100 mm.

Radiographic Comparison of Cranial Tibial Wedge Osteotomy versus Tibial Plateau Leveling Osteotomy: A Cadaveric Study

  • Lee, Jiyoon;Kim, Dongwook;Oh, Hyejong;Lee, Sungin;Choi, Seok Hwa;Kim, Gonhyung
    • Journal of Veterinary Clinics
    • /
    • v.39 no.3
    • /
    • pp.93-99
    • /
    • 2022
  • The present study was performed to compare cranial tibial wedge osteotomy (CTWO) and tibial plateau leveling osteotomy (TPLO) through radiographic evaluation. The experiment was conducted with five cadaver dogs [mean (± SD) weight, 32.9 ± 4.1 kg; mean (± SD) age, 6 ± 2 years; three males and two females] euthanized for reasons unrelated to this study. The cadaver dogs consisted of German Shepherd (n = 3), Belgian Malinois (n = 1), and mixed breed (n = 1). CTWO and TPLO were carried out by the standard surgical method. Radiographic evaluation was performed by comparing several factors, including the flexion and extension angles, the anatomical mechanical axis angle (AMA-angle), tibial length, patellar height measurement using the Labelle-Laurin method, mechanical medial proximal tibial angle (mMPTA), mechanical medial distal tibial angle (mMDTA), and frontal plane alignment (FPA). Both the CTWO and the TPLO groups showed significantly increased flexion angles after surgery. Only the CTWO group had significantly increased extension angle. Although both groups showed significant decreases in the AMA-angle, the mechanical axis moved cranially against the anatomical axis only in the CTWO group. The patellar height was significantly lowered in the CTWO group. No significant differences were found in mMPTA, mMDTA, or FPA. In conclusion, radiographic comparison revealed more changes in CTWO group than in TPLO group.

Orthodontic correction of bialveolar protrusion by interproximal reproximation and water-soluble tubes bonded with deflection-based bonding technique: A case report (인접면 삭제와 변위-기반 접착술로 부착한 수용성 튜브를 이용한 절치 돌출의 교정 치료: 증례보고)

  • Roh, Yu-Yeon;Lim, Sung-Hoon;Jeong, Seo-Rin
    • The Journal of the Korean dental association
    • /
    • v.55 no.12
    • /
    • pp.850-860
    • /
    • 2017
  • Orthodontic treatment with premolar extraction is usually performed to correct bialveolar protrusion. These methods require the use of stiff rectangular working archwire which requires lengthy alignment and leveling before insertion. In this case report, interproximal reproximation was performed instead of extraction. To establish clearance between the archwire and resin domes fixing the archwire, an archwire was inserted into a water-soluble tube before fabricating resin domes. This tube is solved away by the saliva. During fabrication of resin domes, the archwire was deflected intentionally reflecting the displacement of teeth from their ideal position. This can be called as deflection-based bonding (DBB) technique. DBB is different from conventional method of positioning the brackets on its ideal position and then inserting an archwire to align the brackets. Because the orthodontic force of the archwire comes from its deflection from passive configuration, deflecting an archwire as needed can move the teeth more predictably than just bonding brackets on its ideal position. Also, areas with good alignment before orthodontic treatment can be maintained simply by not deflecting the archwire during bonding in these areas. After initial alignment, interproximal reproximation was performed to create 4.8 mm space in the maxillary arch and 4.2 mm space in the mandibular arch. These spaces were closed using orthodontic mini-implant anchorage thus retracting the maxillary incisors 4 mm posteriorly accompanied with 0.7 mm and 0.3 mm distal movement of right and left molars. By using interproximal reproximation and water-soluble tube with DBB, mild bialveolar protrusion was successfully treated without extraction.

  • PDF