• Title/Summary/Keyword: Aligner system

Search Result 26, Processing Time 0.024 seconds

Formation of high uniformity solder bump for wafer level package by tilted electrode ring (경사진 전극링에 의한 웨이퍼레벨패키지용 고균일도의 솔더범프 형성)

  • Ju, Chul-Won;Lee, Kyung-Ho;Min, Byoung-Gue;Kim, Seong-Il;Lee, Jong-Min;Kang, Young-Il;Han, Byung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.366-369
    • /
    • 2003
  • The vertical fountain plating system with the point contact has been used in semiconductor industry. But the plating shape in the opening of photoresist becomes gradated shape, because bubbles from the wafer surface are difficult to escape from the deep openings, vias. So, we designed the tilted electrode ring contact to get uniform bump height on all over the wafer and evaluated the film uniformity by SEM and $\alpha$-step. A photoresist was coated to a thickness of $60{\mu}m$ and vias were patterned by a contact aligner After via opening, solder layer was electroplated using the fountain plating system and the tilted electrode ring contact system. In $\alpha$-step measurement, film uniformities in the fountain plating system and the tilted electrode ring contact system were ${\pm}16%,\;{\pm}3.7%$ respectively. In this study, we could get high uniformity bumps by the tilted electrode ring contact system. So, tilted electrode ring contact system is expected to improve workability and yield in module process.

  • PDF

Development of having double-chamber in micro-bubble pump (두 개의 챔버를 갖는 마이크로 버블펌프의 개발)

  • 최종필;박대섭;반준호;김병희;장인배;김헌영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1186-1190
    • /
    • 2003
  • In this paper, a valveless bubble-actuated fluid micropump was has been developed and its performance was tested. The valveless micropump consists of the lower plate, the middle plate, the upper plate and a resistive heater. The lower plate includes the nozzle-diffuser elements and the double-chamber. Nozzle-diffuser elements and a double-chamber are fabricated on the silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The lower plate also has inlet/outlet channels for fluid flow. The middle plate is made of glass and plays the role of the diaphragm. The chamber in the upper plate is filled with deionized water, and which contacts with the resistive heater. The resistive heater is patterned on a silicon substrate by Ti/Pt sputtering. Three plates and the resister heater are laminated by the aligner and bonded in the anodic bonder. Since the bubble is evaporated and condensed periodically in the chamber, the fluid flows from inlet to outlet with respect to the diffusion effect. In order to avoid backflow, the double chamber system is introduced. Analytical and experimental results show the validity of the developed double-chamber micropump.

  • PDF

Diagnosis and Treatment of Malocclusions using the Invisalign System (인비절라인 시스템을 이용한 부정교합의 진단 및 치료)

  • Kim, Hyungsoo;Ahn, Jae-Hyun;Boyd, Robert L.
    • The korean journal of orthodontics
    • /
    • v.33 no.1 s.96
    • /
    • pp.21-29
    • /
    • 2003
  • Recent developments in software technology have made it possible to create a virtual three-dimensional model of the dental arches from digitally scanned casts of a patient's dentition. This modelmay then be manipulated with software to produce stages of tooth movement from the initial malocclusion to the final desired occlusion. A sterolithograghic model is made for each stage of tooth movement which is the basis for construction of a series of clear and thin overlay appliances. These appliances are worn full time by the patient to move the teeth according to the programmed stages of movement. Malocclusions involving mild to moderate crowding and space closure have been proven to be successfully treated with this appliance. Experience with this appliance has demonstrated excellent patient compliance with less discomfort, improved esthetics and oral hygiene control, when compared with fixed orthodontic appliances. Orthodontic treatment with this appliance is a potentially useful alternative approach to fixed appliances for treatment of a variety of malocclusions in patients with fully erupted permanent teeth.

A Self-healing Space-Division Switch for a 2-Fiber Bidirectional Line Switched Ring (2-선 양방향 선로 스위칭 링을 위한 자기치유 공간분할 스위치 소자)

  • 이상훈;김성진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.12C
    • /
    • pp.240-248
    • /
    • 2001
  • This paper describes the design of a space-division switch which can support a self-healing operation of 2-fiber bidirectional line switched ring in 2.5Gb/s SDH-based transmission system. The switch having a 1.25Gb/s throughput has been designed and implemented with COMPASS tool and 0.87$\mu\textrm{m}$ CMOS gate-array. The proposed switch is suitable for the quickly self-healing operations when a failure occurs in a 2-fiber bidirectional switched ring composed of ADM transmission systems. The switch is composed of an add/drop control part, a cross-point switch, a frame-phase aligner, processor interface and an unequipped data framer. The test results of the switch adapted to 2.SGb/s SDH-based transmission system, show immediate restoration when a failure occurs.

  • PDF

A Study on the Analysis of 5-DOF Axis of Rotation Error in Low Speed Rotary Stage (저속 회전 스테이지의 5자유도 회전축 오차 분석에 관한 연구)

  • Han, Chang-Soo;Kim, Jin-Ho;Shin, Dong-Ik;Yun, Deok-Won;Lee, Yung-Gi;Lee, Sang-Moo;Nam, Gyung-Tai
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.4
    • /
    • pp.23-27
    • /
    • 2007
  • Rotary stages in semiconductor, display industry and many other fields require challenging accuracy to perform their functions properly. Especially, Axis of rotation error on rotary system is significant; such as the spindle error motion of the aligner, wire bonder and inspector machine which result in the poor quality products. To evaluate and improve the performance of such precision rotary stage, undesired movements on the other 5 degrees of freedom of the rotary stage must be measured and analyzed. In this paper, we have measured the three translations and two tilt motions of the worm gear type spindle with high precision capacitive sensors. To obtain the radial error motion, we have used Donaldson's reversal technique. And the axial components of the spindle tilt error motion can be obtained accurately from the axial direction outputs of sensors by Estler face motion reversal technique. Further more we have designed and developed the sensor mounting jig with standard cylinder for reversal method.

  • PDF

Force changes associated with differential activation of en-masse retraction and/or intrusion with clear aligners

  • Zhu, Ye;Hu, Wei;Li, Shuo
    • The korean journal of orthodontics
    • /
    • v.51 no.1
    • /
    • pp.32-42
    • /
    • 2021
  • Objective: To investigate the three-dimensional forces created by clear aligners on mandibular teeth during differential activation with en-masse retraction and/or intrusion in vitro. Methods: Six sets of clear aligners were designed for differential en-masse retraction and/or intrusion procedures in a first premolar extraction model. Group A0 was a control group with no activation. Groups A1-5 underwent different degrees of retractions and/or intrusions. Each group consisted of 10 aligners. Aligner forces were measured on a multi-axis force/torque transducer measurement system in real-time. Results: In the en-masse retraction groups (A1 and A2), lingual and extrusive forces were observed on the incisors; the canines mainly received distal forces; intrusive forces were seen on the second premolars; and the molars received mesial forces. In the en-masse retraction and intrusion groups (A3, A4, and A5), incisors also received lingual and extrusive forces; canines received distal and intrusive forces; mesial and extrusive forces were seen on the second premolars; and the second molars received distal and intrusive forces. The vertical forces on the incisors did not differ significantly among groups A1, A3, and A5. However, the vertical forces on the second premolars reversed from intrusion in group A1 to extrusion in groups A3 and A5. Conclusions: With clear aligners, the "bowing effect" is seen during en-masse anterior teeth retraction and can be partially relieved by performing en-masse retraction accompanied by anterior teeth intrusion. Vertical control of incisors remained unsolved during en-masse retraction, even when intrusive activation was added to the anterior teeth.