• Title/Summary/Keyword: Aliasing artifacts

Search Result 23, Processing Time 0.019 seconds

Fast Thumbnail Extraction Algorithm with Partial Decoding for HEVC (HEVC에서 부분복호화를 통한 썸네일 추출 알고리듬)

  • Lee, Wonjin;Jeong, Jechang
    • Journal of Broadcast Engineering
    • /
    • v.23 no.3
    • /
    • pp.431-436
    • /
    • 2018
  • In this paper, a simple but effective algorithm to reduce the computational complexity of thumbnail generation and to improve image quality without aliasing artifacts is proposed. For the high speed decoding, the proposed algorithm performs partial decoding per $4{\times}4$ boundary in TU(Transform Unit), and preforms TU boundary in PU(Prediction Unit). The proposed method defines the weights based on intra prediction directions and estimates the thumbnail pixel by using that weights. this method remains thumbnail extraction time and improves thumbnail image quality compared with conventional algorithms.

Polar-Format-Processing-Based Moving Target Imaging in MIMO Radar Environment (MIMO 레이다 환경에서 Polar Format Processing 기반 이동표적 이미징)

  • Choi, Sang-Hyun;Yang, Hoon-Gee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.2
    • /
    • pp.124-131
    • /
    • 2019
  • This study presents an imaging algorithm that can provide an image of a moving target in a multiple-input-multiple-output radar environment where multiple transmitting and receiving radars are fixed on the ground. The proposed algorithm, which is based on polar format processing using plane wave approximation, is shown to provide an unaliased image by using multiple transmitting radars even when the distances between the receiving radars are relatively large. We derive the conditions necessary to deploy the transmitting radars by which the resolution of the reconstructed image can be improved, while simultaneously reducing aliasing artifacts. Moreover, we offer a means of separating out each transmitting radar target echo. Finally, the performance of the proposed system is verified through a simulation.

Experimental Identification of Input Power to the Plate Using the Transient Structural Intensity Map

  • Oey, Agustinus;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.110-112
    • /
    • 2009
  • Transient acoustic pressure in the near field of an impacted plate carries information that can be utilized for recovering the impact force history. The inverse calculation approach using BEM-based NAH, which is conventionally used for time harmonic excitation, can be applied for reconstructing the transient waves using the principle of Fourier transform and spectral analysis. Then, using the recovered velocity in normal direction of the plate surface, the corresponding structural intensity can be obtained and the identification of input power can be performed. However, several manipulations should be given to overcome numerical artifacts, such as aliasing and erratic oscillation at discontinuity, and to suppress the effect of noise. Experiment using a simply supported plate is presented for demonstration purpose.

  • PDF

Sampling theory and widening of the viewing area for holographic stereograms (홀로그래픽 스테레오그램에 관한 샘플링 이론과 관찰영역의 확대)

  • Kim, Eun-Seok;Kim, Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.322-327
    • /
    • 1996
  • Unlike holograms of real objects, holographic stereograms(HS) are made using a relatively small number of synthesized 2D images. The influence of aliasing artifacts caused by insufficient or improper sampling is presented, and a new sampling theory is proposed, which is used to making holographic stereograms. Also, the optical system for extension of viewing distance and viewing zone is proposed. Results of this analysis can be applied to design normal holographic stereograms and computer based holographic stereograms.

  • PDF

Cerebral Air Embolism: a Case Report with an Emphasis of its Pathophysiology and MRI Findings

  • Kang, Se Ri;Choi, See Sung;Jeon, Se Jeong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.1
    • /
    • pp.70-74
    • /
    • 2019
  • Cerebral air embolism (CAE) is a rare complication of various medical procedures. It manifests with symptoms similar to those of typical acute cerebral infarction, however the treatment is quite different. We present a case of arterial CAE that was associated with a disconnected central venous catheter and appeared as punctate dark signal intensities with aliasing artifacts on the susceptibility-weighted filtered phase magnetic resonance image. The susceptibility-weighted filtered phase image can be helpful for diagnosing CAE and the magnetic resonance imaging reflects the pathophysiology of CAE.

An Improved Design Method of FIR Quadrature Mirror-Image Filter Banks (개선된 FIR QMF 뱅크의 설계 방법)

  • 조병모;김영수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2C
    • /
    • pp.213-221
    • /
    • 2004
  • A new method for design of two-channel finite-impulse response(FIR) quadrature mirror-image filter(QMF) banks with low reconstruction delay using weighting function is proposed. The weighting function used in this paper is calculated from the previous updated filter coefficients vector which is adjusted from iteration to iteration in the design of QMF banks. In this paper, passband and stopband edge frequency are used in design of QMF banks with low delay characteristic in time domain instead of specific frequency interval where the artifacts occur in conventional design method. The investigation of specific frequency interval where artifacts occur can not be required by using passband and stopband edge frequency. Some comparisons of performance are made with other existing design method to demonstrate the proposed method for QMF bank design. and it was observed that the proposed method using the weighted function and passband and stopband edge frequency improves the peak reconstruction error by 0.001 [dB], the peak-to-peak passband ripple by 0.003[dB], SNR with a white noise by 7[dB] and SNR with a step input by 32[dB], but with a reduction of the computational efficiency because of updating the weighting function over the conventional method in Ref [11].

A Novel Multifocus Image Fusion Algorithm Based on Nonsubsampled Contourlet Transform

  • Liu, Cuiyin;Cheng, Peng;Chen, Shu-Qing;Wang, Cuiwei;Xiang, Fenghong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.3
    • /
    • pp.539-557
    • /
    • 2013
  • A novel multifocus image fusion algorithm based on NSCT is proposed in this paper. In order to not only attain the image focusing properties and more visual information in the fused image, but also sensitive to the human visual perception, a local multidirection variance (LEOV) fusion rule is proposed for lowpass subband coefficient. In order to introduce more visual saliency, a modified local contrast is defined. In addition, according to the feature of distribution of highpass subband coefficients, a direction vector is proposed to constrain the modified local contrast and construct the new fusion rule for highpass subband coefficients selection The NSCT is a flexible multiscale, multidirection, and shift-invariant tool for image decomposition, which can be implemented via the atrous algorithm. The proposed fusion algorithm based on NSCT not only can prevent artifacts and erroneous from introducing into the fused image, but also can eliminate 'block effect' and 'frequency aliasing' phenomenon. Experimental results show that the proposed method achieved better fusion results than wavelet-based and CT-based fusion method in contrast and clarity.

Comparison of Three, Motion-Resistant MR Sequences on Hepatobiliary Phase for Gadoxetic Acid (Gd-EOB-DTPA)-Enhanced MR Imaging of the Liver

  • Kim, Doo Ri;Kim, Bong Soo;Lee, Jeong Sub;Choi, Guk Myung;Kim, Seung Hyoung;Goh, Myeng Ju;Song, Byung-Cheol;Lee, Mu Sook;Lee, Kyung Ryeol;Ko, Su Yeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.2
    • /
    • pp.71-81
    • /
    • 2017
  • Purpose: To compare three, motion-resistant, T1-weighted MR sequences on the hepatobiliary phase for gadoxetic acid-enhanced MR imaging of the liver. Materials and Methods: In this retrospective study, 79 patients underwent gadoxetic acid-enhanced, 3T liver MR imaging. Fifty-nine were examined using a standard protocol, and 20 were examined using a motion-resistant protocol. During the hepatocyte-specific phase, three MR sequences were acquired: 1) gradient recalled echo (GRE) with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA); 2) radial GRE with the interleaved angle-bisection scheme (ILAB); and 3) radial GRE with golden-angle scheme (GA). Two readers independently assessed images with motion artifacts, streaking artifacts, liver-edge sharpness, hepatic vessel clarity, lesion conspicuity, and overall image quality, using a 5-point scale. The images were assessed by measurement of liver signal-to-noise ratio (SNR), and tumor-to-liver contrast-to-noise ratio (CNR). The results were compared, using repeated post-hoc, paired t-tests with Bonferroni correction and the Wilcoxon signed rank test with Bonferroni correction. Results: In the qualitative analysis of cooperative patients, the results for CAIPIRINHA had significantly higher ratings for streak artifacts, liver-edge sharpness, hepatic vessel clarity, and overall image quality as compared to, radial GRE, (P < 0.016). In the imaging of uncooperative patients, higher scores were recorded for ILAB and GA with respect to all of the qualitative assessments, except for streak artifact, compared with CAIPIRINHA (P < 0.016). However, no significant differences were found between ILAB and GA. For quantitative analysis in uncooperative patients, the mean liver SNR and lesion-to-liver CNR with radial GRE were significantly higher than those of CAIPIRINHA (P < 0.016). Conclusion: In uncooperative patients, the use of the radial GRE sequence can improve the image quality compared to GRE imaging with CAIPIRINHA, despite the data acquisition methods used. The GRE imaging with CAIPIRINHA is applicable for patients without breath-holding difficulties.

Subpixel Shift Estimation in Noisy Image Using Iterative Phase Correlation of A Selected Local Region (잡음 영상에서 국부 영역의 반복적인 위상 상관도를 이용한 부화소 이동량 추정방법)

  • Ha, Ho-Gun;Jang, In-Su;Ko, Kyung-Woo;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.1
    • /
    • pp.103-119
    • /
    • 2010
  • In this paper, we propose a subpixel shift estimation method using phase correlation with a local region for the registration of noisy images. Phase correlation is commonly used to estimate the subpixel shift between images, which is derived from analyzing shifted and downsampled images. However, when the images are affected by additive white Gaussian noise and aliasing artifacts, the estimation error is increased. Thus, instead of using the whole image, the proposed method uses a specific local region that is less affect by noises. In addition, to improve the estimation accuracy, iterative phase correlation is applied between selected local regions rather than using a fitting function. the restricted range is determined by analyzing the maximum peak and the two adjacent values of the inverse Fourier transform of the normalized cross power spectrum. In the experiments, the proposed method shows higher accuracy in registering noisy images than the other methods. Thus, the edge-sharpness and clearness in the super-resolved image is also improved.

Adaptive Weight Adjusted Catmull-Rom Spline Interpolation Based on Pixel Intensity Variation for Medical Imaging Volume Visualization (의료영상 볼륨가시화를 위한 화소 값의 변화도에 따른 적응적 가중치를 적용한 캐트멀-롬 스플라인 보간법)

  • Lee, Hae-Na;Yoo, Sun K.
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.2
    • /
    • pp.147-159
    • /
    • 2013
  • In medical visualization, volume visualization is widely used. Applying 3D images to diagnose requires high resolution and accurately implement visualization techniques are being researched accordingly. However, when a three-dimensional image volume visualization is implemented using volume data, aliasing will occur since using discrete data. Supersampling method, getting lots of samples, is used to reduce artifacts. One of the supersampling methods is Catmull-rom spline. This method calculates accurate interpolation value because it is easy to compute and pass through control points. But, Catmull-rom spline method occurs overshoot or undershoot in large gradient of pixel values. So, interpolated values are different from original signal. In this paper, we propose an adaptive adjusting weights interpolation method using Gaussian function. Proposed method shows that overshoot is reduced on the point has a large gradient and PSNR is higher than other interpolated image results.