• Title/Summary/Keyword: Alarm Unit

Search Result 84, Processing Time 0.03 seconds

Evaluation of Clinical Alarms and Alarm Management in Intensive Care Units (중환자실에서 사용되는 의료장비의 경보음 발생과 관리 현황)

  • Jeong, Yu Jin;Kim, Hyunjung
    • Journal of Korean Biological Nursing Science
    • /
    • v.20 no.4
    • /
    • pp.228-235
    • /
    • 2018
  • Purpose: This study aimed to investigate the clinical alarm occurrence and management of nurses toward clinical alarms in the intensive care unit (ICU). Methods: This observational study was conducted with 40 patients and nurses cases in two ICUs of a university hospital. This study divided 24 hours into the unit of an hour and conducted two times of direct observation per unit hour for 48 hours targeting the medical devices applied to 40 patients. Data were analyzed using IBM SPSS Statistics 23. Results: On average, 3.8 units of medical devices were applied for each patient and the ranges of alarm settings were wide. During 48 hours, 184 cases of clinical alarm were occurred by four types of medical devices including physiological monitors, mechanical ventilators, infusion pumps, and continuous renal replacement therapy. Among them, false alarm was 110 cases (59.8%). As for the alarm management by ICU nurses, two-minute alarm mute took up most at 38.0% (70 cases), and no response was second most at 32.6% (60 cases). When valid alarm sounded, nurses showed no response at 43.2%. Conclusion: The findings suggest that a standard protocol for alarm management should be developed for Korean ICU settings. Based on the protocol, continuous training and education should be provided to nurses for appropriate alarm management.

Design of Total RMS(Radiation Monitoring System) for nuclear and nuclear medicine (원자력 및 핵의학 분야용 Total RMS (Radiation Monitoring System)의 설계)

  • Ko, Tae-Young;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.21 no.2
    • /
    • pp.158-161
    • /
    • 2017
  • In this paper, we propose Total RMS(Radiation Monitoring System) for nuclear and nuclear medicine. The proposed system can expand and control Stack Monitor, Area Monitor, and Water(Liquid) Monitor into one system, and can monitor the signals measured by each radiation detector in an integrated manner. The proposed system consists of a sensor module that detects the radiation, a display unit that displays the radiation dose near the radiation detection location, an alarm unit that reports the alarm when the detected radiation dose reaches the danger level, A Main Hub for collecting and storing the contents to the remote monitoring system, and an RMS Monitoring Unit for clearly displaying the measured radiation dose at the remote site. In order to evaluate the performance of Total RMS for the proposed nuclear and nuclear medicine field, it is confirmed that the measurement uncertainty is less than 8.5% and it operates normally within ${\pm}15%$ of the international standard.

A Study on the Alarm Processing System for Fossil Power Plant (화력발전소 경보처리 시스템에 관한 연구)

  • ;;;Zeungnam Bien
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.8
    • /
    • pp.1045-1056
    • /
    • 1995
  • The purpose of multiple alarm processing is to give the operator the correct information and perception of the malfunction present in the plant. In this thesis, an APS(Alarm Processing System) is studied for fossil power plants. This APS is based on a cause-consequence trees in the knowledge representation aspect for alarm and plant and adapts alarm filtering methods using fired time information in the decision aspect. Through the cause-consequence trees and filtering methods, the Alarm Processing System finds the cause alarm among the fired multiple alarms and calculates the cause degree which represents the possibility of a fault occurring in the instruments of the plant with the information of fired alarm. The knowledge base is built via interviews and questionaries with the expert operators on the Seoul power plant unit 4. Finally, the validity of the studied APS is shown via simulations.

  • PDF

Development of an Alarm-Cause Path Tracking System (경보-원인 경로 추적시스템 개발)

  • Lyu, Sung-Pil;Kim, Sang-Hoon;Kim, Eun-Ju;Kim, Jung-Taek
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.11
    • /
    • pp.341-351
    • /
    • 2010
  • Alarm system is very important for the safety of nuclear power plant. When alarm, operator refers alarm logic diagrams to identify the logical relationship between the alarm and its causes. This paper propose a system which tracks the logical path between alarm and its causes on the alarm logic diagrams of Wolsung nuclear power plant unit 3 & 4. And a grammar for the validation of logic diagrams expressed in 2 dimensional strings, and logical operations with 3 states to track alarm-cause paths and to display the state of logics are proposed. This system is on operation at Wolsung site.

Fire Alarm Sound Transmission in Apartment Units (공동주택에서의 화재경보음 전달)

  • Jeong, Jeong-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.67-75
    • /
    • 2018
  • To reduce the number of casualties in the case of fire, an alarm sound needs to be delivered to the people who remain in the apartment unit. On the other hand, it was reported that the fire alarm sound generated in the elevator hall was not delivered sufficiently to the people staying in the apartment units. In this study, the background noise level and noise level generated in an apartment unit were measured during the day and night time. In addition, the transmission of the fire alarm sound into the each room of apartment units was simulated and compared with the background noise level. The fire alarm sound generated in the elevator halls was reduced by the fire door and doors, and was not transmitted sufficiently into the internal spaces of the apartment units. Starting evacuation action was difficult after hearing the fire alarm sound generated outside the apartment units. To improve the transmission of an alarm sound to the inner spaces of apartment units, an acoustic simulation was carried out for cases where the alarm sound generator was installed on a wall-pad in the living room and the alarm sound generator was installed on the ceiling of each rooms in apartment units. Background noise of + 15 dB and 75 dB (A) were satisfied when alarm sound generator was installed on the ceiling of each room.

Automated Unit-test Generation for Detecting Vulnerabilities of Android Kernel Modules (안드로이드 커널 모듈 취약점 탐지를 위한 자동화된 유닛 테스트 생성 기법)

  • Kim, Yunho;Kim, Moonzoo
    • Journal of KIISE
    • /
    • v.44 no.2
    • /
    • pp.171-178
    • /
    • 2017
  • In this study, we propose an automated unit test generation technique for detecting vulnerabilities of Android kernel modules. The technique automatically generates unit test drivers/stubs and unit test inputs for each function of Android kernel modules by utilizing dynamic symbolic execution. To reduce false alarms caused by function pointers and missing pre-conditions of automated unit test generation technique, we develop false alarm reduction techniques that match function pointers by utilizing static analysis and generate pre-conditions by utilizing def-use analysis. We showed that the proposed technique could detect all existing vulnerabilities in the three modules of Android kernel 3.4. Also, the false alarm reduction techniques removed 44.9% of false alarms on average.

UV/IR flame detector using Microprocessor (마이크로프로세서를 사용한 UV/IR 불곶 감지기)

  • 박성진;임병현;임종연;김명원;윤길호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.215-218
    • /
    • 2001
  • A flame detector responds either to radiant energy visible to the human eye or outside the range of human vision. Such a detector is sensitive to glowing embers, coals, or flames which radiate energy of sufficient intensity and spectral quality to actuate the alarm. An infra-red detectors can respond to the total IR component of the flame alone or in combination with flame flicker in the frequency range of 5 to 30 Hz. A major problem in the use of infrared detectors receiving total IR radiation is the possible interference of solar radiation in the infrared region. When detectors are located in places shielded from the sun, such as vaults. filtering or shielding the unit from the sun's rays is unnecessary. In this study, we proposed method for redue a false alarm with using filtering & sensor technology for distinguish of causes of raise a false alarm and pure flame.

  • PDF

Decision of Abnormal Quality Unit Lists from Claim Database

  • Lee, Sang-Hyun;Lee, Sang-Joon;Moon, Kyung-Li;Kim, Byung-Ki
    • Journal of Information Processing Systems
    • /
    • v.4 no.3
    • /
    • pp.113-120
    • /
    • 2008
  • Most enterprises have controlled claim data related to marketing, production, trade and delivery. They can extract the engineering information needed to the reliability of unit from the claim data, and also detect critical and latent reliability problems. Existing method which could detect abnormal quality unit lists in early stage from claim database has three problems: the exclusion of fallacy probability in claim, the false occurrence of claim fallacy alarm caused by not reflecting inventory information and too many excessive considerations of claim change factors. In this paper, we propose a process and methods extracting abnormal quality unit lists to solve three problems of existing method. Proposed one includes data extraction process for reliability measurement, the calculation method of claim fallacy alarm probability, the method for reflecting inventory time in calculating claim reliability and the method for identification of abnormal quality unit lists. This paper also shows that proposed mechanism could be effectively used after analyzing improved effects taken from automotive company's claim data adaptation for two years.

Implementation of the Marine Fog Alarm Equipment using Photoelectric Element (광전소자를 이용한 선박용 안개 경보 장치 구현)

  • Kim, Kab-Ki
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.3
    • /
    • pp.265-268
    • /
    • 2011
  • In this paper, we designed and fabricated that fog alarm equipment detected to crew in maritime fog. Developed fog alarm equipment was combined sensor and a transmitter-receiver module using emitting device unit and receiver photoelectric element infrared LED using only the receive sensitivity was low, miniaturization. Experiment of the fabricated device had a standard that was humidity 70%, the fabricated one generating artificial-fog within visibility 1km. When humidity is over 70%, the fabricated one generates alarming sounds for a warning. When developed device apply to vessel will be able to respond quickly, according to dense fog in the accident.

Microprocessor Control in D-4 Channel Bank (D-4PCM 단말장치에의 마이크로프로세서 응용)

  • 송상훈;김영균
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.16 no.6
    • /
    • pp.40-47
    • /
    • 1979
  • In the recent developent of D-4 Channel Bank which is the basic PCM multiplex terminal, we utilized the one-chip microprocessor in the design of the Alarm and Trunk processing unit besides we could add more flexible functions, we simplified the logic circuits and the discrete parts. Since in Korea, we are lacking in the semiconductor technology, the microprocessor applications in the communication systems desist give us the meaningful advantages in the a aspects of economy, reliability and new technology.

  • PDF