• Title/Summary/Keyword: Airway pressure

Search Result 253, Processing Time 0.029 seconds

Effect of wearing personal protective equipment on cardiopulmonary resuscitation: Focusing on 119 emergency medical technicians (개인보호장비 착용이 심폐소생술에 미치는 영향: 119 구급대원을 중심으로)

  • Shin, Dong-Min;Kim, Seung-Yong;Shin, Sang-Do;Kim, Chu-Hyun;Kim, Tae-Han;Kim, Kyoung-Yong;Kim, Jeong-Hee;Hong, Eun-Jeong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.19 no.3
    • /
    • pp.19-32
    • /
    • 2015
  • Purpose: This study examined the effect of wearing personal protective equipment (PPE) on cardiopulmonary resuscitation (CPR), positive airway pressure, and the posture of emergency medical technicians (EMTs) when conducting CPR. Methods: Twenty 119 EMTs performed 30:2 CPR on a manikin for 4 min. Imaging data were digitized with Kwon3D XP (version 4.0). Data were collected by analyzing the motion when starting in one cycle, such as pressing to the maximum and in the final position (relaxed), and were analyzed with SPSS 18.0. Results: The angle of the elbow joints was significantly reduced (p < .05). The trunk angle was statistically significantly (p < .01, p < .001) increased. The angular velocities of the shoulder joint and left elbow joint were reduced (p > .05). The angular velocity of the trunk was significantly reduced in the starting and maximum compression postures. The hand-escape time was increased. The average compression depth was increased but not significantly (p > .05). The positive airway pressure was reduced (p > .05). Conclusion: The angle of the elbow joints and the angular velocity of the trunk were reduced, and the angle of the trunk was increased. The success of CPR and positive airway pressure was reduced.

Bayesian Network Model to Evaluate the Effectiveness of Continuous Positive Airway Pressure Treatment of Sleep Apnea

  • Ryynanen, Olli-Pekka;Leppanen, Timo;Kekolahti, Pekka;Mervaala, Esa;Toyras, Juha
    • Healthcare Informatics Research
    • /
    • v.24 no.4
    • /
    • pp.346-358
    • /
    • 2018
  • Objectives: The association between obstructive sleep apnea (OSA) and mortality or serious cardiovascular events over a long period of time is not clearly understood. The aim of this observational study was to estimate the clinical effectiveness of continuous positive airway pressure (CPAP) treatment on an outcome variable combining mortality, acute myocardial infarction (AMI), and cerebrovascular insult (CVI) during a follow-up period of 15.5 years ($186{\pm}58$ months). Methods: The data set consisted of 978 patients with an apnea-hypopnea index (AHI) ${\geq}5.0$. One-third had used CPAP treatment. For the first time, a data-driven causal Bayesian network (DDBN) and a hypothesis-driven causal Bayesian network (HDBN) were used to investigate the effectiveness of CPAP. Results: In the DDBN, coronary heart disease (CHD), congestive heart failure (CHF), and diuretic use were directly associated with the outcome variable. Sleep apnea parameters and CPAP treatment had no direct association with the outcome variable. In the HDBN, CPAP treatment showed an average improvement of 5.3 percentage points in the outcome. The greatest improvement was seen in patients aged ${\leq}55$ years. The effect of CPAP treatment was weaker in older patients (>55 years) and in patients with CHD. In CHF patients, CPAP treatment was associated with an increased risk of mortality, AMI, or CVI. Conclusions: The effectiveness of CPAP is modest in younger patients. Long-term effectiveness is limited in older patients and in patients with heart disease (CHD or CHF).

Sleep Onset Insomnia and Depression Discourage Patients from Using Positive Airway Pressure

  • Park, Yun Kyung;Joo, Eun Yeon
    • Journal of Sleep Medicine
    • /
    • v.15 no.2
    • /
    • pp.55-61
    • /
    • 2018
  • Objectives: Despite the accumulating evidence of the effectiveness of positive airway pressure (PAP) therapy in obstructive sleep apnea (OSA) syndrome, adherence to PAP therapy is not high. Several factors reportedly affect PAP adherence; however, it remains unclear whether patients' symptoms were detrimental to adherence rate. This study is aimed at investigating the relationship between insomnia symptoms and adherence. Methods: Retrospective analyses were performed in 359 patients with OSA (mean age $58.4{\pm}13.2$ years; females, n=80). Logistic regression analyses were performed between PAP adherence with clinical factors and questionnaires, such as Epworth Sleepiness Scale, Insomnia Severity Index, and Beck Depression Inventory (BDI). Results: PAP adherence was defined as the use of PAP for ${\geq}4h$ per night on 70% of nights during 30 consecutive days. The median follow-up time was 55 days (interquartile range, 30-119 days), and 54.3% showed poor adherence. Non-adherent patients showed more severe sleep onset insomnia, higher BDI, and higher nadir oxygen saturation ($SaO_2$). Patients with good adherence had higher apnea-hypopnea index, oxygen desaturation index, and respiratory arousal to total arousal ratio. Sleep onset insomnia [odds ratio (OR)=1.792, p=0.012], BDI (OR = 1.055, p=0.026), and nadir $SaO_2$ (OR=1.043, p=0.040) were independently associated with PAP non-adherence. Conclusions: Not the severity of insomnia but sleep onset insomnia was associated with PAP adherence, as well as depressive mood. It suggests that different interventions for reducing insomnia and depressive mood are needed to increase PAP adherence in patients with OSA.

Case of a Change in the Polysomnograpy Results after Using Continuous Positive Airway Pressure in a Patient with Obstructive Sleep Apnea (폐쇄성 수면 무호흡 환자의 지속적 양압기 사용 후 재검사시 수면다원검사 결과의 변화)

  • Kim, Dae Jin;Mun, Sue Jean;Choi, Jeong Su;Lee, Min Woo;Cho, Jae Wook
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.1
    • /
    • pp.119-123
    • /
    • 2019
  • Obstructive sleep apnea (OSA) is a sleep disorder with no breathing symptoms due to repetitive upper airway resistance. OSA is a disease that can have significant effects on the cerebral cardiovascular system. Active treatment is needed to prevent these complications. The use of continuous positive airway pressure (CPAP), the standard therapy of OSA, has comparative therapeutic effects. On the other hand, there is no comparison report of the polysomnography (PSG) results before and after CPAP therapy without using a mask. This paper reports a patient who was diagnosed as OSA and used CPAP every night for more than 2 years. The patient showed a decrease in the apnea-hypopnea index from 64.7/h to 12.9/h. In addition, other sleep-related indicators improved significantly. The daily use of CPAP as a treatment for OSA for more than 2 years may improve the PSG results. Constant follow up of PSG will be needed to adjust the appropriate CPAP pressure to patients because there might be a change in the Apnea-Hypopnea Index and other sleep-related indicators for constant CPAP users for at least 2 years.

Systematic Review of Effects of Nasal Continuous Positive Airway Pressure on Apnea of Preterm Infants (미숙아 무호흡을 위한 비강 지속적 양압환기법 효과에 대한 체계적 고찰)

  • Kim, Eun-Joo
    • Child Health Nursing Research
    • /
    • v.20 no.3
    • /
    • pp.225-235
    • /
    • 2014
  • Purpose: The purpose of this study was to analysis the effects of nasal Continuous Postive Airway Pressure (nCPAP) for preterm infants using systematic review and meta-analysis. Methods: Thirteen peer-reviewed journals including preterm infants and apnea and nCPAP published between 1973 and 2013 were included. Effect size and statistics of homogeneity were done using STATA 10.0. Results: The design for 9 studies was Randomized Control Trial. In most of studies the pressure of nCPAP was set to 4-6 cm$H_2O$. The effect size of 5 studies for the effect on apnea rate using nCPAP compared to nasal Intermittent Positive Pressure Ventilator (nIPPV) showed that the Standardized Mean Difference (SMD) was -0.11 and was not significantly different (Z=0.41, p=.680). But the difference in nCPAP for nasal Synchronizes Intermittent Positive Pressure Ventilator (nSIPPV) (subgroup) was significant (SMD=-.44). The effect size of 7 studies on effect for ventilator weaning of using nCPAP compared to nIPPV showed the Risk Ratio (RR) as 1.60 and was not significantly different (Z=1.12, p=.268). But the difference between nCPAP and nSIPPV (subgroup) was significant (RR=3.94). Conclusion: The results indicate a need for an advanced care system and suggest continuous studies of apnea in preterm infants.

Effect of Pressure Rise Time on Tidal Volume and Gas Exchange During Pressure Control Ventilation (압력조절환기법에서 압력상승시간(Pressure Rise Time)이 흡기 일환기량 및 가스교환에 미치는 영향)

  • Jeoung, Byung-O;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Lim, Chae-Man
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.766-772
    • /
    • 2000
  • Background : Pressure rise time (PRT) is the time in which the ventilator aclieves the set airway pressure in pressure-targeted modes, such as pressure control ventilation (PCV). With varying PRT, in principle, the peak inspiratory flow rate of the ventilator also varies. And if PRT is set to a shorter duration, the effective duration of target pressure level would be prolonged, which in turn would increase inspiratory tidal volume(Vti) and mean airway pressure (Pmean). We also postulated that the increase in Vti with shortening of PRT may relate inversely to the patients' basal airway resistance. Methods : In 13 paralyzed patients on PCV (pressure control 18$\pm$9.5 cm $H_2O$ $FIO_2\;0.6\pm0.3$, PEEP 5$\pm$3 cm $H_2O$, f 20/min, I : E1 : 2) with Servo 300 (Siemens-Elema, Solna, Sweden) from various causes of respiratory failure, PRT of 10 %, 5 % and 0 % were randomly applied. At 30 min of each PRT trial, peak inspiratory flow (PIF, L/sec), Vti (ml), Pmean (cm $H_2O$) and ABGA were determined. Results : At PRT 10%, 5%, and 0%, PIF were 0.69$\pm$0.13, 0.77$\pm$0.19, 0.83$\pm$0.22, respectively (p<0.001). Vti were 425$\pm$94, 439$\pm$101, 456$\pm$106, respectively (p<0.001), and Pmean were 11.2$\pm$3.7, 12.0$\pm$3.7, 12.5$\pm$3.8, respectively (p<0.001). pH were 7.40$\pm$0.08, 7.40$\pm$0.92, 7.41$\pm$0.96, respectively (p=0.00) ; $PaCO_2$ (mm Hg) were 47.4$\pm$15.8, 47.2 $\pm$15.7, 44.6$\pm$16.2, respectively (p=0.004) ; $PAO_2-PaO_2$ (mm Hg) were 220$\pm$98, 224$\pm$95, 227$\pm$94, respectively (p=0.004) ; and $V_n/V_T$ as determined by ($PaCO_2-P_E-CO_2$)/$PaCO_2$ were 0.67$\pm$0.07, 0.67$\pm$0.08, 0.66$\pm$0.08, respectively (p=0.007). The correlation between airway resistance and change of Vti from PRT 10% to 0% were r= -0.243 (p=0.498). Conclusion : Shortening of pressure rise timee during PCV was associated with increased tidal volume, increased mean airway pressure and lower $PaCO_2$.

  • PDF

Comparison of Respiratory Mechanics and Gas Exchange Between Pressure-controlled and Volume-controlled Ventilation (압력조절환기법과 용적조절환기법의 호흡역학 몇 가스교환의 비교)

  • Jeong, Seong-Han;Choi, Won-Jun;Lee, Jung-A;Kim, Jin-A;Lee, Mun-Woo;Shin, Hyoung-Shik;Kim, Mi-Kyeong;Choe, Kang-Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.662-673
    • /
    • 1999
  • Background : Pressure-controlled ventilation (PCV) is frequently used recently as the initial mode of mechanical ventilation in the patients with respiratory failure. Theoretically, because of its high initial inspiratory flow, pressure-controlled ventilation has lower peak inspiratory pressure and improved gas exchange than volume-controlled ventilation (VCV). But the data from previous studies showed controversial results about the gas exchange. Moreover, the comparison study between PCV and VCV with various inspiration : expiration time ratios (I : E ratios) is rare. So this study was performed to compare the respiratory mechanics and gas exchange between PCV and VCV with various I : E raitos. Methods : Nine patients receiving mechanical ventilation for respiratory failure were enrolled. They were ventilated by both PCV and VCV with various I : E ratios (1 : 2, 1 : 1.3 and 1.7 : 1). $FiO_2$, tidal volume, respiratory rate and external positive end-expiratory pressure (PEEP) were kept constant throughout the study. After 20 minutes of each ventilation mode, arterial blood gas, airway pressures, expired $CO_2$ were measured. Results : In both PCV and VCV, as the I : E ratio increased, the mean airway pressure was increased, and $PaCO_2$ and physiologic dead space fraction were decreased. But P(A-a)$O_2$ was not changed. In all three different I : E ratios, peak inspiratory pressure was lower during PCV, and mean airway pressure was higher during PCV. But $PaCO_2$ level, physiologic dead space fraction and P(A-a)$O_2$ were not different between PCV and VCV with three different I : E ratios. Conclusion : There was no difference in gas exchange between PCV and VCV under the same tidal volume, frequency and I : E ratio.

  • PDF

Treatment of Snoring and Obstructive Apnea with Oral Appliance (코골이와 수면무호흡증의 구강내 장치 치료)

  • Tae, Il Ho
    • The Journal of the Korean dental association
    • /
    • v.53 no.4
    • /
    • pp.259-265
    • /
    • 2015
  • Recently, oral appliances for treating snoring and obstructive sleep apnea are widely used. Among various appliances, mandibular advancement devices are most effective without serious side effects. Advancement of mandible keep airway open and decrease snoring and/or obstructive apnea events. They can be used as stand-alone therapy or an adjunct to continuous positive air pressure for lowering air pressure. Oral appliances should be applied by dentists who have knowledges and experiences on occlusion and temporomandibular disorders and manage of side effects.

Comparison of the Ventilatory Volume and Airway Pressures using Oxylator EM-100, MicroVenT CSI-3000, OXY-LIFE II -A manikin study - (산소소생기 Oxylator EM-100, MicroVenT CSI-3000, OXY-LIFE II의 환기량과 기도내압 비교 - 마네킨 연구 -)

  • Shim, Gyu-Sik;Kim, Eun-Mee;Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.113-118
    • /
    • 2017
  • The purpose of this study was to compare the ventilatory volume and airway pressure using Oxylator EM-100, MicroVenT CSI-3000, OXY-LIFE II. The data were obtained from February 13 in 2017 andanalyzed using the SPSS WIN 18.0 program. The results of theventilatory volume showed the Oxylator EM-100 551.44 ml (${\pm}18.70$), MicroVenT CSI-3000 527.26 ml (${\pm}17.98$), and OXY-LIFE II 369.46 ml (${\pm}12.30$). The airway pressure showed the Oxylator EM-100 $11.89cmH_2O$ (${\pm}.41$), MicroVenT CSI-3000 $11.66cmH_2O$ (${\pm}.34$), and OXY-LIFE II $8.02cmH_2O$ (${\pm}.25$). This study will provide the basic data for an appropriate ventilation method by an oxygen supply device including Oxylator EM-100, MicroVenT CSI-3000, and OXY-LIFE II.

Implement the system of the Position Change for Obstructive sleep apnea patient (폐쇄성수면 무호흡 환자의 자세변환 시스템 구현)

  • Ye, Soo-young;Eum, Sang-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.6
    • /
    • pp.1231-1236
    • /
    • 2017
  • In this study, we developed a system that can change position to improve obstructive sleep apnea. Blocking of the breathing airway caused by obstruction of the apnea, lateral position is provided by the airway to improve the apnea. We used a pressure sensor (FSR402) in the form of an array to determine the position of patient. The air cylinder was controlled to raise and lower the bed. As a result of calculating the pressure difference between the supine position and the lateral position, it was $0.41{\pm}0.30$ and $1.09{\pm}0.73$. In other words, when the patient is lateral position, the difference between the sensor values on the right and left side is large. Therefore, it is confirmed that the system can maintain airway to breath for improvement of obstructive sleep.