• Title/Summary/Keyword: Airflow modification

Search Result 9, Processing Time 0.021 seconds

A Study on the Performance of Noise Level and Airflow Amount of a Kitchen Hood by the Different Conditions of Airflow Path. (레인지후드 덕트설치 조건에 따른 소음 및 풍량특성 연구)

  • Kim, Il-Ho;Kim, Youn-Jae;Lee, Yong-Jun;Lee, Kyu-Dong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.11-14
    • /
    • 2007
  • Noise level and Airflow amount of a kitchen hood are affected by the conditions of airflow path. Thus this study is expected to be used as a basic reference in designing airflow path of apartment housing throughout analysing changes in noise level and airflow amount from the various conditions of airflow path. Noise level generated by the kitchen hood is estimated in a kitchen and a living room of two constructed apartment houses, and an experiment is conducted in an half anechoic chamber to analyze noise level and airflow amount by the different length, diameter and number of windings of a round shaped soft duct which is connected to the kitchen hood. The measured results in apartment houses show that the noise level in both apartments exceeds the NC standard greatly in living spaces. In apartment A, a regular apartment house, the noise level was $NC-65{\sim}75$, $NC-45{\sim}60$ and NC-70, NC-45 in the kitchen and living room with an operation of kitchen hood in 1 and 3 stages. In apartment B, an apartment complex, the noise level was NC-55 and NC-60 in the kitchen and living room with an operation of kitchen hood in 3 stages. In particular, there was an increase of noise level at 125Hz-band resulted from an amplification of sound, which requires adequate measures in noise reduction. The results measured in Half anechoic chamber show 99% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ 100mm to ${\Phi}$ 125mm, 37% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ 125mm to ${\Phi}$ 150mm, and 173% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ l00mm to ${\Phi}$ 150mm. The noise level was lower than the level measured in apartment housing about 20 in NC-value and 11.4 in dB(A)-value, which was interpreted as the effect of the load by the pressure condition at the rear end of the duct. Also, an amplification of sound in 125Hz-band influenced NC-value considerably, therefore effective measure is needed.

  • PDF

The Importance of Early Chronic Obstructive Pulmonary Disease: A Lecture from 2022 Asian Pacific Society of Respirology

  • Don D. Sin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.86 no.2
    • /
    • pp.71-81
    • /
    • 2023
  • Chronic obstructive pulmonary disease (COPD) affects close to 400 million people worldwide. COPD is characterized by significant airflow limitation on spirometry. Most patients with COPD are diagnosed in their fifth or sixth decades of life. However, the disease begins much earlier. By the time airflow limitation is detected on spirometry, patients with COPD have lost close to 50% of their small airways. Thus, identification of patients with early COPD, defined as persons with preserved spirometry, who demonstrate pathologic or functional hallmarks of COPD, is essential for disease modification and ultimately disease elimination. This paper provides an up-to-date overview of the current case definition of early COPD, its importance, the novel technologies required for its detection in young adults and future directions in therapeutics for treatment.

Characteristics of ionic Wind in a DC Corona Discharge in Needle-to-punched plate Geometry (침 대 중공평판전극에서 직류코로나 방전에 의한 이온풍 특성)

  • Lee, Bok-Hee;Kil, Hyeong-Joon;Eom, Ju-Hong;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.74-80
    • /
    • 2003
  • Ionic wind is produced by a corona discharge when a DC high voltage is applied across the point-to-plane gap geometry. The corona discharge phenomena have been investigated in several beneficial application fields such as electrostatic cooling, ozone generation, electrostatic precipitation and electrostatic spraying. Recently ionic wind might be used in aerodynamic, for example, heat transfer, airflow modification, and etc. In this work, in order to analyze the control behavior of the velocity and amount of ionic wind produced by the positive DC corona discharges. The ionic wind velocity was measured as a function of the applied voltage, diameter of the punched hole on plate electrode and separation between the point-to-plate electrodes. As a results, the airflow is generated from the tip of needle to the plate electrode in the needle-to-punched-plate electrode systems. The ionic wind velocity is linearly increased with an increase in applied voltage and ranges from 1 to 3 m/sec at the locations of 100-200 mm from the punched-plate.

Numerical Study on Convective Heat Transfer in a Compartment Fire(II) - Mixed Convection - (실내화재에 있어서의 대류열전달에 관한 수치연구(II) -혼합대류-)

  • 박외철;고경찬;이광진
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.33-39
    • /
    • 1999
  • In a compartment fire with openings, convective heat transfer consists of natural convection from the hot bodies and forced convection by airflow through the openings. The same finite volume method that was applied to pure natural convection in part I was utilized without modification to the square cavity with two openings. The objective of this study is to investigate effects of the openings on temperature distribution. Flow patterns, temperature distribution and heat transfer were compared for different Rayleigh numbers and with and without the openings.

  • PDF

Effect of Suction Nozzle Modification on the Performance and Aero-acoustic Noise of a Vacuum Cleaner

  • Park, Cheol-Woo;Lee, Sang-Ik;Lee, Sang-Joon
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1648-1660
    • /
    • 2004
  • The suction nozzle of a vacuum cleaner was modified to enhance the power performance and to reduce the airflow-induced acoustic noise. The suction power efficiencies of the vacuum cleaner were measured for various nozzles; (1) original nozzle, (2) original nozzle with modified trench height, (3) original nozzle with modified connecting chamber, and (4) a combination of (2) and (3). In addition, the suction pressure and sound pressure level around the suction nozzle were measured to validate the reduction of acoustic noise. The power efficiency and mean suction pressure increased when the trench height of the suction nozzle was increased. This was attributed to the suppression of the flow separation in the suction channel. Modification of the connecting chamber in the original nozzle, which had an abrupt contraction from a rectangular chamber into a circular pipe, into a smooth converging contraction substantially improved the suction flow into the connecting pipe. When both modifications were applied simultaneously, the resulting suction nozzle was more effective from the viewpoints of aerodynamic power increase and sound pressure level reduction.

Uncertainty Analysis and Improvement of an Altitude TestFacility for Small Jet Engines

  • Jun, Yong-Min;Yang, In-Young;Kim, Chun-Taek;Yang, Soo-Seok;Lee, Dae-Sung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.5 no.1
    • /
    • pp.46-56
    • /
    • 2004
  • The verification and improvement of the measurement uncertainty have beenperformed in the altitude test facility for small gas turbine engines, which was built atthe Korea Aerospace Research Institute (KARI) in October 1999. This test is performedwith a single spool turbojet engine at several flight conditions. This paper discussesthe evaluation and validation process for the measurement uncertainty improvements usedin the altitude test facility. The evaluation process, defined as tests before the facilitymodification, shows that the major contnbutors to the measurement uncertainty are theflow meter discharge coefficient, the inlet static and total pressures, the cell pressureand the fuel flow rate. The measurement uncertainty is focused on the primary parametersof the engine performance such as airflow rate, thrust and specific fuel consumption (SFC).The validation process, defined as tests after the facility modification, shows that themeasurement uncertainty, in seal level condition, is tmproved to the acceptable level throughthe facility modification. In altitude test conditions, the measurement uncertainties arenot improved as much as the uncertainty in sea level condition.

Investigation of the HV Ionic Wind Generator and the Control of Corona Discharge for Air-flow Formation (기류형성을 위한 고전압 이온풍 발생장치와 코로나 제어기술에 관한 기초적 연구)

  • Lee, B.H.;Eom, J.H.;Kang, S.M.;Chang, K.C.;Ahn, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1707-1709
    • /
    • 2002
  • Ionic wind may be produced by DC corona discharges. In this work, the electrical effect has studied to evaluate applicability in fields of electrostatic cooling, ozone generation, electrostatic precipitation, heat transfer, air flow modification, and etc. The ionic wind velocity was measured as a function of the distance of pin to plate and the diameter of punched hole. The pin to punched-plate electrode generates airflow from pin to plate and the flow direction is controlled by the hole size of punched-plate, input voltage and distance between two electrodes. As a consequence, the ionic wind velocity is nearly proportional to the applied voltages and ranges from 1 to 3 m/sec.

  • PDF

Modification of an LPG Engine Generator for Biomass Syngas Application (바이오매스 합성가스 적용을 위한 LPG 엔진발전기 개조 및 성능평가)

  • Eliezel, Habineza;Hong, Seong Gu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.5
    • /
    • pp.9-16
    • /
    • 2022
  • Syngas, also known as synthesis gas, synthetic gas, or producer gas, is a combustible gas mixture generated when organic material (biomass) is heated in a gasifier with a limited airflow at a high temperature and elevated pressure. The present research was aimed at modifying the existing LPG engine generator for fully operated syngas. During this study, the designed gasifier-powered woodchip biomass was used for syngas production to generate power. A 6.0 kW LPG engine generator was modified and tested for operation on syngas. In the experiments, syngas and LPG fuels were tested as test fuels. For syngas production, 3 kg of dry woodchips were fed and burnt into the designed downdraft gasifier. The gasifier was connected to a blower coupled with a slider to help the air supply and control the ignition. The convection cooling system was connected to the syngas flow pipe for cooling the hot produce gas and filtering the impurities. For engine modification, a customized T-shaped flexible air/fuel mixture control device was designed for adjusting the correct stoichiometric air-fuel ratio ranging between 1:1.1 and 1.3 to match the combustion needs of the engine. The composition of produced syngas was analyzed using a gas analyzer and its composition was; 13~15 %, 10.2~13 %, 4.1~4.5 %, and 11.9~14.6 % for CO, H2, CH4, and CO2 respectively with a heating value range of 4.12~5.01 MJ/Nm3. The maximum peak power output generated from syngas and LPG was recorded using a clamp-on power meter and found to be 3,689 watts and 5,001 watts, respectively. The results found from the experiment show that the LPG engine generator operated on syngas can be adopted with a de-ration rate of 73.78 % compared to its regular operating fuel.

Small Turbojet Engine Test and Uncertainty Analysis (소형 터보제트 엔진 시험 및 불확도 분석)

  • Jun, Yong-Min;Yang, In-Young;Nam, Sam-Sik;Kim, Chun-Taek;Yang, Soo-Seok;Lee, Dae-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.5
    • /
    • pp.118-126
    • /
    • 2002
  • The Altitude Engine Test Facility(AETF) was built at the Korea Aerospace Research Institute and has been being operated for the gas turbine engines in the class of 3,000 lbf thrust. To enhance the confidence level of AETF to the international level, a series of studies and facility modification have been conducted to improve the measurement uncertainty and reliability. In this paper, some part of the facility evaluation tests performed with a single spool turbojet engine are introduced. Tests were performed simulating the flight conditions as steady state, sea level for various flight speeds (i.e., Mn=0.3, 0.5, 0.7, 0.9). The obtained test results are compared with the predicted values of the engine DECK. The measurement uncertainties of airflow, net thrust, fuel flow and SFC showed 0.791~0.914%, 0.851~1.706%, 1.372~7.348% and 1.642~5.205%, respectively. Thus, from this research, the improvement methods of uncertainties on AETF has been confirmed.