• 제목/요약/키워드: Airflow control

Search Result 128, Processing Time 0.023 seconds

A Study on the Optimum Design of SUV Rear Spoiler (SUV 차량 리어 스포일러 최적 형상에 관한 연구)

  • Park, Dong-Kyou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.689-694
    • /
    • 2018
  • Recently, fuel consumption efficiency has become the most important issue in the vehicle development process due to the problem of environmental pollution. The air flow patterns of the vehicle body line and rear part are the most important elements affecting the fuel consumption efficiency. Especially, the airflow pattern of the vehicle rear part is the most important design factor to be considered in rear spoiler design. In this paper, the control factors affecting the airflow of the rear spoiler are determined, the airflow sensitivity of these control factors are tested and, then, the optimized control factors to reduce the airflow drag force are proposed. The model of optimized control factors is tested and the values of the optimized control factors are changed by analyzing the S/N ratio and mean value. Finally, the new modified model incorporating the optimized control factors is tested in an air flow tunnel and its ability to decrease the air drag and reduce the cost is verified.

An Effect of Car Performance Influenced to Absorbing Resistane of Air-cleaner Filter for the L. P. G Vehicle of Open Loop Fuel System (Open Loop 연료공급계의 L. P. G 차량에서 공기청정기 필터의 흡기저항이 차량성능에 미치는 영향)

  • Shin, Yong-Wha;Kim, Ki-Hyung;Jung, Jong-An
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.36-46
    • /
    • 1995
  • The interest and purpose of this study is to control of air-fuel ratio and develop control device of a spark ignition LPG engine with adopting open loop fuel system. The air-fuel ratio is derived by considering airflow resistane of air cleaner element. The result shows that air-fuel ratio becomes more and more rich when airflow resistance increases. Experiments about the influence of airflow resistance on the engine performance, drivability and emissions are performed. Therefore, it is known that open-loop fuel system depends on the absorbing resistance of air-cleaner.

  • PDF

Analysis of New Air Control System in Clean Stocker(II) (Clean Stocker내 새로운 방식의 기류제어에 관한 연구(II))

  • Choi, Gi-Han;Han, Chang-Woo;Lee, Sang-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1178-1186
    • /
    • 2002
  • Clean stockers are being used by semiconductor and TFT-LCD manufacturers to store and buffer work in process. The only way to keep the stored product clean is to provide constant clean airflow the product and through stocker. Up to now, stockers typically have been configured to receive their laminar airflow from fan filter units that are located on the side of the stocker. This type of stocker may have such problems as complexity of structure, increment of temperature, mechanical vibration, initial investment and running cost. In this study, in order to solve the above mentioned problems, new air control system in stocker is proposed, which is to control open ratios of exits that are located on the side of the stocker without fan filter units. In this study, static pressure regain was used for the analysis of the open ratios of exits theoretically and experiment was also conducted using actual clean stocker for TFT-LCD manufacturers and CFDesign, was used for simulating airflow in stocker. As a result, open ratios of exits can be obtained by the analysis of static pressure regain and was verified by experiment and simulation results. Therefore, new air control system in stocker can be used by the semiconductor and TFT-LCD manufacturers.

A Study on the Idle Speed Control under Load Disturbance (부하변동에 강인한 엔진 공회전 속도제어에 관한 연구)

  • 최후락;장광수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.37-50
    • /
    • 1997
  • The objective of this paper is to study on the idle speed control using the fuzzy logic controller under load disturbance. The design procedure for fuzzy logic controller depends on the expert's knowledge or trial and error. The inputs of the fuzzy controller are error of rpm and variation of rpm. The output of the fuzzy controller is an ISC motor step and ignition timing. The airflow is controlled by the ISC motor movement and the idle speed is controlled by the airflow control and ignition timing control. During the control, air to fuel was checked by LAMBDA sensor. All experiments were performed in a real vehicle.

  • PDF

Comparision of Heat Exchanging Performance Depending on Different Arrangement of Heat Exchanging Pipe (II) (열회수장치의 열교환 파이프배치형식별 열교환 성능 비교(II))

  • Suh, Won-Myung;Kang, Jong-Guk;Yoon, Yong-Cheol;Kim, Jung-Sub
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.281-285
    • /
    • 2001
  • This study was carried out to improve the performance of heat recovery device attached to exhaust gas flue connected to combustion chamber of greenhouse heating system. Three different units were prepared for the comparison of heat recovery performance; AB-type(control unit) is exactly the same with the typical one fabricated for previous study of analyzing heat recovery performance in greenhouse heating system, other two types(C-type and D-type) modified from the control unit are different in the aspects of airflow direction(U-turn airflow) and pipe arrangement. The results are summarized as follows; 1. In the case of Type-AB, when considering the initial cost and current electricity fee required for system operation, it is expected that one or two years at most would be enough to return the whole cost invested. 2. Type-C and Type-D, basically different with Type-AB in the aspect of airflow pattern, are not sensitive to the change of blower capacity with higher than $25\;m^{3}/min$. Therefore, heat recovery performance was not improved so significantly with the increment of blower capacity. This is assumed to be that air flow resistance in high air capacity reduces the heat exchange rate as well. Never the less, compared with control unit, resultant heat recovery rate in Type-C and Type-D were improved by about 5% and 13%, respectively. 3. Desirable blower capacity for these heat recovery units experimented are expected to be about $25\;m^{3}/min$, and at the proper blower capacity, U-turn airflow units showed better heat recovery performance than control unit. But, without regard to the type of heat recovery unit, it is recommended that comprehensive consideration of system's physical factors such as pipe arrangement density, unit pipe length and pipe thickness, etc., are required for the optimization of heat recovery system in the aspects of not only energy conservation but economic system design.

  • PDF

Fuel Cell Modeling and Load Controlling by the Variable Utilization of Airflow (연료전지 모델링 및 공기이용률 제어에 관한 연구)

  • Song, S.H.;Lee, W.Y.;Kim, C.H.;Park, Y.P.
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.1
    • /
    • pp.48-52
    • /
    • 2003
  • A mathematical dynamic model of fuel cell was formulated in order to design the control system which will meet the control object. The control objective is set to regulate the airflow in the load change by utilization of airflow and the pressure difference between anode and cathode is maintained below a limit range. Simulation result of 10kW polymer electrolyte membrane fuel cell (PEMFC) clearly demonstrates that response time need to be less. than 1 seconds for the control requirements. Besides, pressure difference was allowed in pressure range less than 0.01 atm.

Experimental Study of the Effect on Cabin Thermal Comfort for Cold Storage Systems in Vehicles (축냉 시스템이 차 실내 열 쾌적성에 미치는 영향에 관한 실험적 연구)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.4
    • /
    • pp.428-435
    • /
    • 2015
  • This paper presents the experimental study of cabin thermal comfort using a cold storage heat exchanger in a vehicle air-conditioning system. Recent vehicle-applied ISG functions for fuel economy and emission, but when vehicles stop, compressors in the air-conditioning system stop, and the cabin temperature sharply increases, making passengers feel thermal discomfort. This study conducts thermal comfort evaluation in the vehicle, which is applied to a cold storage system for the climate control wind tunnel test and the vehicle fleet road test with various airflow volume rates and ambient temperatures blowing to the cold storage heat exchanger. The experimental results, in the cold storage system, air discharge temperature is $3.1-4.2^{\circ}C$ lower than current air-conditioning system when the compressor stops and provides cold air for at least 38 extra seconds. In addition, the blowing airflow volume to the cold storage heat exchanger with various ambient temperature was examined for the control logic of the cold storage system, and in the results, the airflow volume rate is dominant over the outside temperature. For this study, a cold storage system is economically useful to keep the cabin at a thermally comfortable level during the short period when the engine stops in ISG vehicles.

A Performance Evaluation of Zone Smoke Control Systems for Railway Underground Transit Passage by Smoke Control TAB (제연 TAB를 통한 철도 지하환승통로의 거실제연설비 성능평가)

  • Seol, Seok-Kyun;Kim, Joon-Hwan;Park, Min-Seok;Oh, Seung-Min;Ahn, Yong-Chul;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • This study conducted Testing, Adjusting, and Balancing (TAB), which is a type of field performance evaluation experiment of a zone smoke-control system, at a railway underground transit passage installed with a zone smoke- control system to find problems and improvements for ensuring performance. TAB for the smoke control system was classified into several procedures, such as design data review, duct leakage test, field measurement of the airflow rate, velocity of the fan and duct, and a smoke test. Through the duct leakage test, the system leakage ratio was examined to prove the duct sealing. The iImprovement of the smoke control airflow problems due to the lack of fan static pressure loss was the secured performance. The performance of the smoke control fan was secured by improvements of the smoke control airflow rate problems caused by the loss of static pressure in the intake duct. The smoke test in the smoke control zone confirmed that the damper operating schedule subject was influenced by natural wind or train wind.

A Study on Aerodynamic and Aeroacoustic Characteristics around Pantograph (판토그라프 주변의 유동 및 소음 특성에 관한 연구)

  • 유승원;민옥기;박춘수;정흥채
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.529-536
    • /
    • 2000
  • This paper describes the analysis of aerodynamics and the prediction of airflow induced noise around simplified pantograph. First, computational fluid dynamics (CFD) is conducted far several model to evaluate linear/nonlinear flow field characteristics due to high speed flow and the CFD results support the computational aeroacoustics. The accurate prediction of the aeroacoustic analysis is necessary for designers to control and reduce the airflow induced noise. We adopt the acoustic analogy based on Ffowcs Williams- Hawkings (FW-H) equation and predict aeroacoustic noise.

  • PDF

Evaluation and Prediction of Cleanliness Level in the Mini-Environment System Using Local Mean Air-Age (국소평균공기연령을 이용한 국소환경시스템의 청정도 평가 및 예측)

  • Noh, Kwang-Chul;Lee, Hyeon-Cheol;Park, Jung-Il;Oh, Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.5
    • /
    • pp.457-466
    • /
    • 2007
  • A numerical and experimental study on the evaluation and the prediction of cleanliness level in the mini-environment system was carried out. Using the concept of local mean air-age (LMA) and effective flow rate, the new direct method for estimating the mini-environment was developed and compared with the previous performance index of airflow pattern characteristics. It was found out that the airflow pattern analysis is a restricted method to estimate the real performance of the mini-environment. The reason is that the airflow pattern cannot predict the effect of the increment of the ventilation rate on the cleanliness level in the mini-environment. While LMA is capable of showing the effects of the contaminant accumulation caused by turbulent intensity, eddy, and the increment of the effective flow rate. This result showed that LMA is more exact and effective performance index than the previous one like the airflow pattern characteristics.