• Title/Summary/Keyword: Airflow Analysis

Search Result 263, Processing Time 0.029 seconds

A Numerical Analysis on the Airflow Characteristics in Super Cleanrooms with Different Design Types (초청정 클린룸 공조방식에 따른 기류특성에 관한 수치해석)

  • 노광철;이승철;오명도
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.751-761
    • /
    • 2003
  • We performed the numerical analysis on the airflow characteristics in the two type of cleanroom systems, which are the axial fan type (AFT) and the fan filter unit (FFU). A computational fluid dynamic model was applied to investigate and compare the nonuniformity, the deflection angle and the air ventilation effectiveness of the two designs of cleanrooms when dampers are adjusted and not adjusted. And the flow-resistance models of the various components were used in this simulation. We know that the airflow characteristics of the cleanrooms are largely affected by damper adjusting And we also find out that the FFU system is superior to the AFT system through the comparison of the cleanroom performance indices.

A Study on Aerodynamic and Aeroacoustic Characteristics around Pantograph (판토그라프 주변의 유동 및 소음 특성에 관한 연구)

  • 유승원;민옥기;박춘수;정흥채
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.529-536
    • /
    • 2000
  • This paper describes the analysis of aerodynamics and the prediction of airflow induced noise around simplified pantograph. First, computational fluid dynamics (CFD) is conducted far several model to evaluate linear/nonlinear flow field characteristics due to high speed flow and the CFD results support the computational aeroacoustics. The accurate prediction of the aeroacoustic analysis is necessary for designers to control and reduce the airflow induced noise. We adopt the acoustic analogy based on Ffowcs Williams- Hawkings (FW-H) equation and predict aeroacoustic noise.

  • PDF

The experimental research on periodic airflow in human nasal cavity (비강내 주기유동장의 실험적 해석에 관한 연구)

  • Kim, Sung-Kyun;Son, Yeong-Rak;Sin, Seok-Jae
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1687-1692
    • /
    • 2004
  • Airflow in the nasal cavity of a normal Korean adult is investigated experimentally by tomographic PIV measurement. Knowledge of airflow characteristics in nasal cavities is essential to understand the physiology and pathology aspects of nasal breathing. Several studies have utilized physical models of the healthy nasal cavity to investigate the relationship between nasal anatomy and airflow. All of these researches on nasal airflow are under the condition of constant flow-rate. In this study, nasal cavity flow with the physiological period is investigated by tomographic PIV, for the first time. A pumping system that can produce the periodic flow is created. Thanks to a new method for the model casting by a combination of the rapid prototyping and curing of clear silicone, a transparent rectangular box containing the complex nasal cavity can be made for PIV. The CBC PIV algorithm is used for analysis. Phase-averaged mean and RMS velocity distributions are obtained for inspirational and expiration nasal airflows. The comparison with the constant flow case is appreciated. There exist many flow patterns depending on each phase.

  • PDF

Analysis of New Air Control System in Clean Stocker(II) (Clean Stocker내 새로운 방식의 기류제어에 관한 연구(II))

  • Choi, Gi-Han;Han, Chang-Woo;Lee, Sang-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1178-1186
    • /
    • 2002
  • Clean stockers are being used by semiconductor and TFT-LCD manufacturers to store and buffer work in process. The only way to keep the stored product clean is to provide constant clean airflow the product and through stocker. Up to now, stockers typically have been configured to receive their laminar airflow from fan filter units that are located on the side of the stocker. This type of stocker may have such problems as complexity of structure, increment of temperature, mechanical vibration, initial investment and running cost. In this study, in order to solve the above mentioned problems, new air control system in stocker is proposed, which is to control open ratios of exits that are located on the side of the stocker without fan filter units. In this study, static pressure regain was used for the analysis of the open ratios of exits theoretically and experiment was also conducted using actual clean stocker for TFT-LCD manufacturers and CFDesign, was used for simulating airflow in stocker. As a result, open ratios of exits can be obtained by the analysis of static pressure regain and was verified by experiment and simulation results. Therefore, new air control system in stocker can be used by the semiconductor and TFT-LCD manufacturers.

Risk Factors for Unawareness of Obstructive Airflow Limitation among Adults with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 유소견 성인의 폐쇄성 기류제한 상태 비인지 영향요인)

  • Jo, Mirae;Oh, Heeyoung
    • Research in Community and Public Health Nursing
    • /
    • v.29 no.3
    • /
    • pp.290-299
    • /
    • 2018
  • Purpose: The purpose of the present study is to examine risk factors for unawareness of obstructive airflow limitation among adults with chronic obstructive pulmonary disease. Methods: Secondary data analysis was performed with the data from the 6th Korea National Health and Nutrition Examination Survey (KNHANES; 2013-2014). The data were analyzed with the IBM SPSS 22.0 version using frequency, percentage, odds ratio, and logistic regression. Results: Ninety-eight percent of subject with a pulmonary function test score of $FEV_1/FVC$<0.7 (N=833) did not recognize that their lung function was impaired. The heavy drink, absence of tuberculosis or asthma diagnosis, and no symptom of expelling phlegm were identified as major risk factors for unawareness of airflow limitation. Conclusion: In order to increase awareness of airflow limitation and to prevent the worsening of the condition, the pulmonary function screening test should be provided to community residents including those who do not show symptoms of respiratory illness.

Evaluation and Prediction of Cleanliness Level in the Mini-Environment System Using Local Mean Air-Age (국소평균공기연령을 이용한 국소환경시스템의 청정도 평가 및 예측)

  • Noh, Kwang-Chul;Lee, Hyeon-Cheol;Park, Jung-Il;Oh, Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.5
    • /
    • pp.457-466
    • /
    • 2007
  • A numerical and experimental study on the evaluation and the prediction of cleanliness level in the mini-environment system was carried out. Using the concept of local mean air-age (LMA) and effective flow rate, the new direct method for estimating the mini-environment was developed and compared with the previous performance index of airflow pattern characteristics. It was found out that the airflow pattern analysis is a restricted method to estimate the real performance of the mini-environment. The reason is that the airflow pattern cannot predict the effect of the increment of the ventilation rate on the cleanliness level in the mini-environment. While LMA is capable of showing the effects of the contaminant accumulation caused by turbulent intensity, eddy, and the increment of the effective flow rate. This result showed that LMA is more exact and effective performance index than the previous one like the airflow pattern characteristics.

Uncertainty Analysis of Interzonal Airflow Rates by Tracer Gas Methods (추적가스를 이용한 실간환기량 산정방법에 따른 불확실성 해석)

  • Han, Hwa-Taik;Cho, Seok-Hyo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.529-534
    • /
    • 2008
  • Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Tracer gas techniques are widely used to measure ventilation rates, ventilation effectiveness, and interzonal air movements. Depending on the number of gases used, they are divided into single and multi tracer gas methods. This paper deals with the comparison of the tracer gas methods in measuring air exchange rate between rooms. Experiments have been conducted in a simple two-room model with known airflow rates. In multi-gas procedure, the concentration decays of two tracer gases, i.e SF6 and R134a are measured after simultaneous injections in each room. The single tracer gas method is also applied by injecting SF6 gas with a time lag between two rooms. The data reduction procedures are developed to obtain the interzonal airflow rate using the matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, and smoothing. Uncertainty for each airflow rate is investigated depending on the parameters based on the setting values.

  • PDF

An Aerodynamic and Acoustic Study of Nasalization in Cleft Palate Speakers. (구개열 언어의 비음화에 관한 공기역학 및 음향학적 연구)

  • Lee, Jong-Han;Shin, Hyo-Keun
    • Speech Sciences
    • /
    • v.5 no.1
    • /
    • pp.105-119
    • /
    • 1999
  • Cleft palate patients have general speech problems with resonance disorders and articulation disorders. The aim of this study is to find the aerodynamic and acoustic characteristics of the nasalization in cleft palate speakers. Thirteen control groups and three cleft palate patients pre- and post operation were selected for these studies. The test words are composed by polysyllabic words: consonants between high vowel /i/ analysis. The cleft palate patients repeated test words pre- and post-operation from one, three and six month periods. The subjects repeated test words on Macquirer and on Nasometer Model 6200-3. The aerodynamic and acoustic results of nasalization show as follows: (1) The nasal rate in overall airflow of aspirated consonant for cleft palate patients shows higher levels than that of the control group. It had decreased since one month after operation. (2) The overall airflow of cleft palate patients is higher than in the control group, however oral air pressure is lower than control group. (3) The nasal airflow and the nasal rate in overall airflow of cleft palate patients has higher than the control group, however its decreased after operation. (4) The nasalance scores of cleft palate patients were 40% higher than that of the control group. The scores did not decrease after operation. The nasalance score of lateral and fricative sounds did not decrease after operation.

  • PDF

An Analysis of the Physiological and Psychological Responses Elicited When Wearing an Aerogel Cold Protective Jacket in Airflow (에어로젤 방한 재킷 착용시의 기류 유무에 따른 생리·심리학적 특성 분석)

  • Seong-Suk Kim;Su-Young Son;Hee-Eun Kim
    • Human Ecology Research
    • /
    • v.62 no.2
    • /
    • pp.317-326
    • /
    • 2024
  • This study evaluated the thermal physiological and psychological responses elicited when wearing cold protective jackets with aerogel fillings in two cold environments, one without air velocities and one with air velocities (2.3 m·s-1), at an air temperature of 10℃. The participants were five healthy young males. Measures were taken of physiological parameters, blood pressure (BP), heart rate (HR), core temperature, oxygen uptake (Vo2), and microclimate (temperature and humidity). The psychological parameters evaluated were thermal and wetness sensation. No differences were observed in systolic blood pressure, heart rate, and oxygen intake between the conditions. At tympanic temperature, a significant difference was observed between the conditions during exercise (p<.05); . A significant difference was observed in the microclimate temperature of the clothing according to the airflow, and temperature changes in the chest and back revealed different patterns. Significant differences were observed in thermal sensation (whole body (p<.05), chest (p<.05), back (p<.01)) between airflow conditions. The results therefore indicate that cold protective jackets with an aerogel filling are suitable for people operating in low-temperature and airflow environments.

Factors Associated with Indacaterol Response in Tuberculosis-Destroyed Lung with Airflow Limitation

  • Kim, Tae Hoon;Rhee, Chin Kook;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.82 no.1
    • /
    • pp.35-41
    • /
    • 2019
  • Background: Pulmonary tuberculosis can result in anatomical sequelae, and cause airflow limitation. However, there are no treatment guidelines for patients with a tuberculosis-destroyed lung. Recently, indacaterol effectiveness in chronic obstructive pulmonary disease (COPD) patients with Tuberculosis history (INFINITY) study revealed indacaterol provided bronchodilation and symptom improvement in COPD patients with a tuberculosis-destroyed lung. Methods: We conducted a post-hoc subgroup analysis of the randomized controlled trial, the INFINITY study, to determine factors associated with indacaterol response in a tuberculosis-destroyed lung with airflow limitation. Data from 68 patients treated with inhaled indacaterol, were extracted and analyzed. Factors associated with the response of forced expiratory volume in one second ($FEV_1$) to indacaterol treatment, were determined using linear regression analysis. Results: Of 62 patients included, 68% were male, and 52% had history of cigarette smoking. Patients revealed mean $FEV_1$ of 50.5% of predicted value with mean improvement of 81.3 mL in $FEV_1$ after indacaterol treatment for 8 weeks. Linear regression analysis revealed factors associated with response of $FEV_1$ to indacaterol included a short duration of smoking history, and high short-acting bronchodilator response. When patients with history of smoking were excluded, factors associated with response of $FEV_1$ to indacaterol included high short-acting bronchodilator response, and poor health-related quality of life score as measured by St. George's Respiratory Questionnaire for COPD. Conclusion: In a tuberculosis-destroyed lung with airflow limitation, short-acting bronchodilator response and smoking history can play a critical role in predicting outcomes of indacaterol treatment.