긴급전환형 임시음압격리병실의 기밀도에 따른 최소 급배기 유량차 평가 (Analysis of Minimum Airflow Differences between Supply and Exhaust Air according to Airtightness of Rapidly Converted Temporary Negative Pressure Isolation Rooms)

  • 신희원;김동욱;김지민;정효범;강동화
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제29권4호
    • /
    • pp.69-77
    • /
    • 2023
  • Purpose: During the COVID-19 pandemic, there have been many cases of converting regular hospital wards into temporary negative pressure isolation wards. The purpose of this study is to evaluate the minimum airflow differences that satisfies the pressure difference criteria(-2.5 Pa) according to airtightness of switching type wards, in preparation for utilization of aging regular wards as negative pressure isolation wards. Methods: Visual inspection and field measurements were conducted using blower door to evaluate airtightness of 5 hospital wards. CONTAM simulation was used to assess the airflow differences when pressure difference between the corridor and wards met the criteria at various levels of airtightness. Results: The ACH50 of evaluated wards ranged from 19.3 to 50.1 h-1 with an average of 37.0 h-1, indicating more than four times leakier than other building types. The minimum airflow differences increased as the airtightness of the wards decreased and the size of the wards increased. Implications: When operating rapidly converted negative pressure isolation wards, understanding airtightness is crucial for determining the minimum airflow differences to maintain the pressure differences. The analysis of this study suggests that improving the airtightness of aging rooms is essential and the minimum airflow differences should be suggested considering both the airtightness and size of rooms.

FLUENT를 활용한 콘크리트 건식 저장용기 공기유로 내부 유동장 해석 (ANALYSIS ON FLOW FIELDS IN AIRFLOW PATH OF CONCRETE DRY STORAGE CASK USING FLUENT CODE)

  • 강경욱;김형진;조천형
    • 한국전산유체공학회지
    • /
    • 제21권2호
    • /
    • pp.47-53
    • /
    • 2016
  • This study investigated natural convection flow behavior in airflow path designed in concrete dry storage cask to remove the decay heat from spent nuclear fuels. Using FLUENT 16.1 code, thermal analysis for natural convection was carried out for three dimensional, 1/4 symmetry model under the normal condition that inlet ducts are 100% open. The maximum temperatures on other components except the fuel regions were satisfied with allowable values suggested in nuclear regulation-1536. From velocity and temperature distributions along the flow direction, the flow behavior in horizontal duct of air inlet and outlet duct, annular flow-path and bent pipe was delineated in detail. Theses results will be used as the theoretical background for the composing of airflow path for the designing of passive heat removal system by understanding the flow phenomena in airflow path.

비강 내 공기유동에 대한 실험 및 전산 유동가시화 (Numerical and Experimental Flow Visualization on Nasal Airflow)

  • 김성균;박준형;휜광림
    • 대한기계학회논문집B
    • /
    • 제33권6호
    • /
    • pp.461-467
    • /
    • 2009
  • Knowledge of airflow characteristics in nasal cavities is essential to understand the physiological and pathological aspects of nasal breathing. Several studies have utilized physical models of the healthy nasal cavity to investigate the relationship between nasal anatomy and airflow. In our laboratory, there have been a series of experimental investigations on the nasal airflow in normal, abnormal, and deformed nasal cavity models by PIV under both constant and periodic flow conditions. In this time normal and several deformed nasal cavity models, which simulate surgical operation, Turbinectomy, are investigated numerically by the FVM general purpose code and PIV analysis. The comparisons of these results are appreciated. Dense CT data and careful treatment of model surface under the ENT doctor's advice provide more sophisticated cavity models. The Davis (LaVision Co.) code is used for PIV flow analysis. Average and RMS distributions have been obtained for inspirational and expirational nasal airflows in the normal and deformed nasal cavities.

3-D THERMAL-HYDRAULIC ANALYSIS FOR AIRFLOW OVER A RADIATOR AND ENGINE ROOM

  • Hsieh, C.T.;Jang, J.Y.
    • International Journal of Automotive Technology
    • /
    • 제8권5호
    • /
    • pp.659-666
    • /
    • 2007
  • In the present study, a numerical analysis of the three-dimensional heat transfer and fluid flow for a vehicle cooling system was developed. The flow field of the engine room between the grille and radiator was analyzed. The results show that, as the airflow inlet grille angle $\alpha$ is varied from $15^{\circ}$ to $-15^{\circ}$, the air flow rate compared with $\alpha=0^{\circ}$(horizontal) changes from -11.9% to +5.1%; while the heat flux from the radiator changes from -9.2% to +4.4%. When the airflow inlet bumper angle $\beta$ is varied from $-5^{\circ}$ to $+15^{\circ}$, the heat flux from the radiator compared with $\beta=0^{\circ}$(horizontal) increases up to +4.4%. When the airflow inlet grille angle $\alpha=-15^{\circ}$ and the bumper grill angle $\beta=+15^{\circ}$, the airflow rates and heat flux compared with($\alpha=0^{\circ}$, $\beta=0^{\circ}$) can be increased to +9.5% and +7.5%, respectively. The results indicate that the optimal angles for cooling efficiency are used.

Investigation of the effects of miniscrew-assisted rapid palatal expansion on airflow in the upper airway of an adult patient with obstructive sleep apnea syndrome using computational fluid-structure interaction analysis

  • Hur, Jae-Sik;Kim, Hyoung-Ho;Choi, Jin-Young;Suh, Sang-Ho;Baek, Seung-Hak
    • 대한치과교정학회지
    • /
    • 제47권6호
    • /
    • pp.353-364
    • /
    • 2017
  • Objective: The objective of this study was to investigate the effects of miniscrew-assisted rapid palatal expansion (MARPE) on changes in airflow in the upper airway (UA) of an adult patient with obstructive sleep apnea syndrome (OSAS) using computational fluid-structure interaction analysis. Methods: Three-dimensional UA models fabricated from cone beam computed tomography images obtained before (T0) and after (T1) MARPE in an adult patient with OSAS were used for computational fluid dynamics with fluid-structure interaction analysis. Seven and nine cross-sectional planes (interplane distance of 10 mm) in the nasal cavity (NC) and pharynx, respectively, were set along UA. Changes in the cross-sectional area and changes in airflow velocity and pressure, node displacement, and total resistance at maximum inspiration (MI), rest, and maximum expiration (ME) were investigated at each plane after MARPE. Results: The cross-sectional areas at most planes in NC and the upper half of the pharynx were significantly increased at T1. Moreover, airflow velocity decreased in the anterior NC at MI and ME and in the nasopharynx and oropharynx at MI. The decrease in velocity was greater in NC than in the pharynx. The airflow pressure in the anterior NC and entire pharynx exhibited a decrease at T1. The amount of node displacement in NC and the pharynx was insignificant at both T0 and T1. Absolute values for the total resistance at MI, rest, and ME were lower at T1 than at T0. Conclusions: MARPE improves airflow and decreases resistance in UA; therefore, it may be an effective treatment modality for adult patients with moderate OSAS.

Clean Stocker내 새로운 방식의 기류제어에 관한 해석 (Analysis of New Air Control System in Clean Stocker)

  • 최기한;한창우;이상룡
    • 대한기계학회논문집A
    • /
    • 제26권1호
    • /
    • pp.121-130
    • /
    • 2002
  • Clean stockers are being used by semiconductor and TFT-LCD manufacturers to store and buffer work in process. Since an important function of a stocker is to keep the contained material clean. The only way to keep the stored product clean is to provide constant clean airflow the product and through stocker, The airflow across the product prevent contamination from settling on the product. Up to now, stocker typically have been configured to receive their laminar airflow from fan filter units that are located on the side of the stocker This type of stocker may have such problems as complexity of structure, increment of temperature, mechanical vibration, initial investment and running cost. In this study, In order to solve the above mentioned problems, new air control system in stocker is proposed, which is to control open ratios of exits that are located on the side of the stocker without fan filter units. Open ratios of exits need to be optimized for the same quantities of airflow in each exit. In this study, static pressure regain was used for the analysis of the open ratios of exits theoretically and Blue Ridge Numerics FEM software, CFDesign, was used fur simulating airflow in stocker. As a result, Open ratios of exits important to provide constant clean airflow can be obtained by the analysis of static pressure regain and was verified by simulation results. Therefore, new air control system in stocker can be used by the semiconductor and TFT-LCD manufacturers.

기능적 음성장애인의 발성역치압력과 발성역치기류 특성 연구 (A Study on the Characteristics of Phonation Threshold Pressure and Phonation Threshold Airflow of Patients with Functional Voice Disorder)

  • 이인애;윤주원;황영진
    • 말소리와 음성과학
    • /
    • 제5권1호
    • /
    • pp.63-69
    • /
    • 2013
  • This study attempted to investigate the characteristics of Phonation Threshold Pressure and Phonation Threshold Airflow of Patients who have Functional voice disorder. 50 subjects participated in study (32 subjects were patients who had functional voice disorders and 20 subjects were normal adults). The PAS (Phonatory aerodynamic system, model 6600, KAY electronics, Inc.) was used to measure the data and to do the analysis. Data from the Phonation Threshold Pressure was measured using voicing efficiency of the PAS protocol. Data from the Phonation Threshold Airflow was measured using Maximum Sustained Phonation of the PAS protocol. Those were used because of the ease of phonation. The results of this study showed that the differences in Phonation Threshold Pressure and Phonation Threshold Airflow between patients who had functional voice disorder and normal adults could be significant index. Patients who had functional voice disorder showed more higher figures than normal adults. These results suggest that Phonation Threshold Pressure and Phonation Threshold Airflow are very useful in diagnosing the voice disorder. The measured data also provided useful information for diagnosing patients with vocal fold diseases.

환기량 변화에 따른 실내공기질과 국소급기지수 특성 (Characteristics of Indoor Air Quality and Local Supply Index with a Variation of Supply ${\cdot}$ Exhaust Airflow rate)

  • 한창우;노광철;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.21-26
    • /
    • 2005
  • We performed the numerical analysis on the characteristics of indoor air quality and local supply index with a variation of supply · exhaust airflow rate. We analyzed the local supply index and carbon dioxide concentration at the room and breathing zone with respect to the variation of the supply · exhaust airflow rate. From the numerical results, we found that local supply index was affected but carbon dioxide concentration was hardly affected by the variation of the airflow rate in the room. And we also knew that carbon dioxide concentration was raised in despite of the increment of the supply airflow rate in the breathing zone. After this study it is necessary to analyze the local exhaust index when we evaluate the state of the ventilation in the room.

  • PDF

비강내 주기유동장의 실험적 해석에 관한 연구 (The Experimental Research on Periodic Airflow in Human Nasal Cavity)

  • 신석재;김성균
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.103-109
    • /
    • 2005
  • Airflow in the nasal cavity of a normal Korean adult is investigated experimentally by tomographic PIV measurement. Knowledge of airflow characteristics in nasal cavities is essential to understand the physiology and pathology aspects of nasal breathing. Several studies have utilized physical models of the healthy nasal cavity to investigate the relationship between nasal anatomy and airflow. All of these researches on nasal airflow are under the condition of constant flow-rate. In this study, nasal cavity flow with the physiological period is investigated by tomographic PIV, for the first time. A pumping system that can produce the periodic flow is created. Thanks to a new method for the model casting by a combination of the rapid prototyping and curing of clear silicone, a transparent rectangular box containing the complex nasal cavity can be made for PIV, The CBC PIV algorithm is used for analysis. Phase-averaged mean and RMS velocity distributions are obtained for inspirational and expiration nasal airflows. The comparison with the constant flow case is appreciated. There exist many flow patterns depending on each phase.

포그분사 및 공기유동에 의한 온실재배 토마토의 엽온 변화 (Change in the Plant Temperature of Tomato by Fogging and Airflow in Plastic Greenhouse)

  • 남상운;김영식;서동욱
    • 생물환경조절학회지
    • /
    • 제23권1호
    • /
    • pp.11-18
    • /
    • 2014
  • To investigate the influence of surrounding environment on the plant temperature and examine the effect of plant temperature control by fogging and airflow, plant temperature of tomato, inside and outside air temperature and relative humidity, solar radiation and wind speed were measured and analyzed under various experimental conditions in plastic greenhouse with two-fluid fogging systems and air circulation fans. According to the analysis of plant temperature and the change of inside and outside air temperature in each condition, inside air temperature and plant temperature were significantly higher than outside air temperature in the control and shading condition. However, in the fogging condition, inside air temperature was lower or slightly higher than outside air temperature. It showed that plant temperature could be kept with the temperature similar to or lower than inside air temperature in fogging and airflow condition. To derive the relationship between surrounding environmental factor and plant temperature, we did multiple regression analysis. The optimum regression equation for the temperature difference between plant and air included solar radiation, wind speed and vapor pressure deficit and RMS error was $0.8^{\circ}C$. To investigate whether the fogging and airflow contribute to reduce high temperature stress of plant, photosynthetic rate of tomato leaf was measured under the experimental conditions. Photosynthetic rate was the highest when using both fogging and airflow, and then fogging, airflow and lastly the control. So, we could assume that fogging and airflow can make better effect of plant temperature control to reduce high temperature stress of plant which can increase photosynthetic rate. It showed that the temperature difference between plant and air was highly affected by surrounding environment. Also, we could estimate plant temperature by measuring the surrounding environment, and use it for environment control to reduce the high temperature stress of plant. In addition, by using fogging and airflow, we can decrease temperature difference between plant and air, increase photosynthetic rate, and make proper environment for plants. We could conclude that both fogging and airflow are effective to reduce the high temperature stress of plant.