• 제목/요약/키워드: Airborne particle

검색결과 172건 처리시간 0.029초

주물사업장 주공정별 발생하는 분진의 석영함유량 및 크기분포 연구 (Analysis of Quartz Content and Particle Size Distribution of Airborne Dust from Selected Foundry Operations)

  • 피영규;노영만;이광묵;김형아;김용우;원정일;김현욱
    • 한국산업보건학회지
    • /
    • 제7권2호
    • /
    • pp.196-208
    • /
    • 1997
  • This study was performed to estimate quartz contents in the both bulk and airborne dust samples and to determine particle size distribution of airborne dust from the selected foundry operations. Total dust samples were collected by a 37mm cassette and respirable by a 10 mm nylon cyclone. Particle size distributions were determined by a Marple's 8-stage cascade impactor at the melting, molding, shakeout and finishing operations. The presence of elements in the dust samples were confirmed by the scanning electron microscopy equipped with the energy dispersive x-ray spectrometry. The quartz contents were estimated using the intensity of the absorption peak of quartz at 799 cm-l by the Fourie Transformed Infrared Spectroscopy (FTIR). The results were as follows: 1. The analysis of data from cascade Impactor showed bimodal distributions of particle size at the melting, molding and shakeout operations. Mass median aerodynamic diameters for the distributions determined by histogram were $0.48-1.65{\mu}m$ for small and $13.43-19.58{\mu}m$ for large modes. In the dust samples collected at the finishing operations, however, only a large mode of $18.89{\mu}m$ was found. 2. The percentages of total to respirable dust concentration calculated from the impactor data ranged from 42 % to 66 %. The average concentrations of respirable dust by cyclone were $0.85-1.28mg/m^3$ collected from the workers, and were $0.23-0.56mg/m^3$ from the areas surveyed. Dust concentrations of personal samples were statistically significantly higher than those of area samples. The highest dust concentration was obtained from the personal samples of the finishing operation. 3. The mean percentages of silicon and oxygen estimated by SEM-EDXA in the bulk samples ranged from 35.83 % to 36.02 % and from 39.93 %-41.64 %, respectively. 4. The average quartz contents estimated by FTIR in the respirable dust from personal samples ranged from 4.32 % to 5.36 % and 4.54 % to 4.70 % in the bulk samples. No statistical difference of quartz content was found between foundry operations. In this study, quartz content was quantified by FTIR. Although no statistically significant difference in quartz content between airborne and bulk, samples and between different foundry operations was found, it is recommended that quartz content in the individual sample of respirable dust be analyzed and the results be used either to select an applicable quartz limits or to calculate the exposure limit. Further studies, however, are needed to compare the results by FTIR and XRD since it is reported that the quartz content determined by FTIR is different from that by XRD.

  • PDF

탄소나노튜브 성장 실험실에서 CVD 밀폐 여부에 따른 공기 중 나노입자 농도 비교 (Comparison of Airborne Nanoparticle Concentrations between Carbon Nanotubes Growth Laboratories based on Containment of CVD)

  • 하주현;신용철
    • 한국산업보건학회지
    • /
    • 제20권3호
    • /
    • pp.184-191
    • /
    • 2010
  • Although the usage of nanomaterials including carbon nanotubes (CNTs) has increased in various fields, scientific researches on workers' exposures and controls of these materials are very limited. The purpose of this study was to compare the airborne nanoparticles concentrations from two university laboratories conducting experiments of CNTs growth based on containment of thermal chemical vapor deposition (CVD). Airborne nanoparticle concentrations in three metrics (surface area concentration, particle number concentration, and mass concentrations) were measured by task using three direct reading instruments. In a laboratory where CVD was not contained, the surface area concentration, number concentration and mass(PM$_1$) concentration of airborne nanoparticles were 1.5 to 3.5 times higher than those in the other laboratory where CVD was confined. The ratio of PM$_1$ concentration to total suspended particles(TSP) in the laboratory where CVD was not confined was about 4 times higher than that in the other laboratory. This indicates that CVD is a major source of airbone nanoparticles in the CNTs growth laboratories. In conclusion, researchers performing CNTs growth experiments in these laboratories were exposed to airborne nanoparticles levels higher than background levels, and their exposures in a laboratory with the unconfined CVD were higher than those in the other laboratory with the confined CVD. It is recommended that in the CNTs growth laboratories adequate controls including containment of CVD be implemented for minimizing researchers' exposures to airborne nanoparticles.

경남지역의 실내외 공기 중 총섬유 입자의 농도특성 및 석면 입자의 확인 (Concentration Characteristics of Indoor and Outdoor Airborne Total Fiber Particles and Identification of Asbestos in Gyeongnam Provinces)

  • 박희은;박정호;김형갑
    • 한국산업보건학회지
    • /
    • 제22권2호
    • /
    • pp.119-127
    • /
    • 2012
  • Objectives: The aim of this study is to identify concentration characteristics of indoor and outdoor airborne total fiber particles and asbestos in Gyeongnam Provinces. Methods: This study investigated concentration characteristics of indoor fiber particles from 748 schools and 38 public facilities as well as outdoor particles from 11 sites through PCM (phase contrast microscope). SEM/EDX (scanning electron microscope/energy dispersive using X-ray analysis) was used to obtain physicochemical information of asbestos fiber particles. The study identified asbestos rate in the 15 samples from indoor and outdoor airborne total fiber particles. Results: 1. The average indoor airborne concentrations of total fiber particles were $0.0011{\pm}0007$ f/cc in schools and $0.0015{\pm}0007$ f/cc in public facilities by PCM. Over 90% of the fiber particles were identified as single fibers. 2. The average outdoor airborne concentrations of total fiber particles were $0.0007{\pm}0002$ f/cc, and they were lower than those of indoor airborne concentrations. 3. The results showed that the form of asbestiform was diverse as skein of thread like form and long needle, which was relatively narrower than that of glass fiber and rock wool. 4. The results of SEM/EDX analysis of 15 areas where total fiber particle was relatively high showed that the form was rather similar to that of asbestos, but chemical composition was proven to be non-asbestos. Conclusions: The concentration of indoor and outdoor airborne total fiber particles of Gyeongnam Provinces satisfied the IAQ (Indoor air quality) level of 0.01 f/cc and asbestos was not found in most of the samples by SEM/EDX.

음압격리병실에서의 기침 토출입자의 입경에 따른 확산 및 침적에 대한 수치해석 연구 (A Numerical Study on Coughed Particle Dispersion and Deposition in Negative Pressure Isolation Room according to Particle Size)

  • 정민지;홍진관
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제24권2호
    • /
    • pp.37-44
    • /
    • 2018
  • Purpose: This study investigates the influences of coughing direction and healthcare worker's location on the transport characteristics of coughed particles in airborne infection isolation room (AIIR), which is commonly called negative pressure isolation room, with a downward ventilation system. Methods: Computational Fluid Dynamics (CFD) was used to simulate the airflow and for tracing the behavior of particles. Results: The results show that the airflow pattern and coughing direction have a significant influence on the characteristics of particle dispersion and deposition. When healthcare workers are in the isolation room with the patient who is lying on the bed, it is recommended to be located far from the anteroom to reduce the exposures from infectious particles. And when the patient is lying, it is more effective in removing particles than when the patient is in Fowler's position. Although it is an isolation room that produces unidirectional flow, coughing particles can spread to the whole room and a large number of particles can be deposited onto patient, bed, side rails, healthcare worker, ceiling, floor, and sidewall. Implications: Following the patients' discharge or transfer, terminal cleaning of the vacated room, furniture, and all clinical equipment is essential. Also, it is necessary to establish detailed standard operating procedure (SOP) in order to reduce the risk of cross-contamination.

일부 서울 지역 대기 부유세균 분포 현황 조사 (Atmospheric Distribution Characteristics of Airborne Bacteria in Part of Seoul Area)

  • 김기연;김윤신;이철민;조만수;변상훈
    • 한국대기환경학회지
    • /
    • 제25권6호
    • /
    • pp.493-502
    • /
    • 2009
  • The concentrations of outdoor airborne bacteria measured in Seoul, Korea for one year (Jan. 2008~Dec. 2008) ranged from $500CFU/m^3$ to $7,500CFU/m^3$. In monthly concentration distribution, the level of outdoor airborne bacteria was highest in September and October and lowest in March. In seasonal concentration distribution, the order of level of outdoor airborne bacteria was autumn>winter>spring>summer. In regional concentration distribution, the highest level of outdoor airborne bacteria was generally found in the forest, followed by general area and traffic site. In distribution characteristics according to particle size, outdoor airborne bacteria showed 31% for >$7.0{\mu}m$ (stage 1), 21% for $4.7{\sim}7.0{\mu}m$(stage 2), 15% for $3.3{\sim}4.7{\mu}m$(stage 3), 19% for $2.1{\sim}3.3{\mu}m$(stage 4), 10% for $1.1{\sim}2.1{\mu}m$(stage 5), and 4% for $0.65{\sim}1.1{\mu}m$(stage 6) and its mean respirable fraction was 48%. In concentration distribution by yellow dust, the mean levels of outdoor airborne bacteria were 803 $(\pm479)CFU/m^3$ for period of yellow dust and 691 $(\pm1,134)CFU/m^3$ for period of non-yellow dust. Although the level of outdoor airborne bacteria was higher in period of yellow dust than period of non-yellow dust, there was no significant difference between period of yellow dust and non-yellow dust (p>0.05). In correlation analysis between outdoor airborne bacteria and atmospheric factors (temperature and relative humidity), there was no significant correlation between outdoor airborne bacteria and atmospheric factors. The predominant airborne bacteria were identified to the Bacillus-derived species.

등방성 난류에서 침강하는 무거운 입자의 거동 (On behavior of settling heavy particles in isotropic turbulence)

  • 정재달;여경민;이창훈
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.437-440
    • /
    • 2006
  • Particle suspension is frequently observed in many natural flows such as in the atmosphere and the ocean as well as in various engineering flows. Recently, airborne micro or nano-scale particles in atmosphere attract much attention from environmental society since small particle cause serious environmental problems in the industrialized areas. Also, the characteristics of such heavy particles' behavior is quite different from its fluid particles because the inertia force and buoyance force acting on the heavy particles are different than those acting on fluid particles. Therefore, our studies is to investigate the characteristics of the behavior of heavy particles considering the inertia effect with or without gravity effect, but do not consider modification of turbulence by the particles, that is one-way interaction. We carried out direct numerical simulation of isotropic turbulence with particles under the Stokes drag assumption for a spherical particle. These results can be used in the development of a stochastic model for predicting particle's behavior.

  • PDF

HYSPLIT 모형 입력설정에 따른 바람 이동경로 예측 결과 공간 분석 (Spatial Analysis of Wind Trajectory Prediction According to the Input Settings of HYSPLIT Model)

  • 김광수;이승재;박진유
    • 한국농림기상학회지
    • /
    • 제23권4호
    • /
    • pp.222-234
    • /
    • 2021
  • 바람에 의해 해외지역에서 국내로 유입되는 비래해충들은 주요 작물에 상당한 피해를 초래할 수 있다. 바람에 의한 비래해충의 이동 경로를 추정하기 위해 기상 모형들이 사용되는데, 본 연구에서는 비래해충이 도달할 수 있는 지역을 예측할 때 입력설정이 미치는 영향을 분석하였다. 벼멸구가 중국에서 국내로 유입된다는 가정하에 입자의 바람이동 경로를 추적하기 위해 개발된 HYbrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) 모형을 사용하여 바람의 이동경로를 예측하였다. 중국, 한국 및 일본이 포함된 중규모 수치기상모형 자료를 사용하여 순간 및 평균 풍속자료가 포함된 기상입력자료를 생성하였다. 또한, 이동 경로 계산을 위해 계산 시간 간격을 1, 30, 60분으로 설정하였다. 중국에서 벼멸구가 관측된 지점에서 2019년과 2021년 6월 상순 기간 동안 바람의 이동 경로를 계산한 결과, 순간 풍속과 평균 풍속자료를 사용함에 따라 비래해충 도달지점에 큰 차이가 나타났다. 계산 시간에 따른 이동 경로 결과값들의 공간적 분포는 상대적으로 유사도가 높았으며, 순간풍속을 사용한 경우 벼멸구 관측지역과 비교적 유사한 경향이 나타났다. 이러한 결과는 바람 경로를 추적하여 비래해충 도착지점을 추정할 때 사용되는 입력자료의 특성을 파악하고 이들로부터 발생하는 불확도에 대한 고려가 필요함을 시사한다.

일부지역 양돈장 및 양계장 공기중 박테리아, 진균, 내독소 농도 (Evaluation of Environmental Circumstance Within Swine and Chicken Houses in South Korea for the Production of Safe and Hygienic Animal Food Products)

  • 김영환;서형주;김진만;정연훈;문경환
    • 한국축산식품학회지
    • /
    • 제28권5호
    • /
    • pp.623-628
    • /
    • 2008
  • This study was undertaken to determine the concentrations of airborne bacteria, fungi, particles, and endotoxin in swine and chicken houses. Six swine buildings and seven chicken houses were randomly selected in southern Gyonggi Province, South Korea. The geometric mean concentrations of airborne bacteria in swine and chicken houses were $2.7{\times}10^5\;CFU/m^3$ and $5.6{\times}10^7\;CFU/m^3$, respectively. The airborne bacteria concentrations in chicken houses were significantly higher than those of swine houses (p<0.05). The geometric mean concentration of airborne fungi in swine houses was $4.9{\times}10^3\;CFU/m^3$, which was higher than the value of $2.1{\times}10^3\;CFU/m^3$ found in chicken houses. The mean concentrations of airborne particles and endotoxin in swine houses were $3.48\;mg/m^3$ and $943.1\;EU/m^3$, and they were $15.43\;mg/m^3$ and $1,430.5\;EU/m^3$ in chicken houses, respectively. A significant difference between swine and chicken houses was found for total dust (p<0.05), but not for endotoxin. In this study, the concentrations of endotoxin in both swine and chicken houses as well as particles in chicken houses were high, and in about 50% of the samples exceeded the worker health safety levels of $614\;EU/m^3$ suggested in previous studies. These results may indicate a considerable respiratory hazard for workers in these environments.