• Title/Summary/Keyword: Air-particle flow

Search Result 394, Processing Time 0.024 seconds

A Study on Pressure Drop Through The Porous Metal (소결금속층(燒結金屬層)에서의 압력강화(壓力降下)에 관한 연구(硏究))

  • Ohu, Su-Cheol
    • Solar Energy
    • /
    • v.12 no.2
    • /
    • pp.43-50
    • /
    • 1992
  • This study has been conducted to provide fundamental knowledge of the characteristics of pressure drop through porous metal by experimental investigation. Pressure drop of air passing through porous metal was measured. The influences of porosity and flow velocity on pressure drop were investigated and in view of friction factor, the experimental data was compared with theorical equation as known to Ergun's equation concerning unconsolid packed bed. The result of this study are as follows. The pressure drop was increased with increasing the flow velocity and at the same flow velocity with decreasing the porosity(decreasing the particle diameter), In Particular, the experimental equation for the pressure drop was derived using the particle diameter, matrix diameter and matrix thickness. The experimental data were correlated well(mean deviation ${\pm}15%$ )with the present empirical dimensionless equation.

  • PDF

Study on the optimal design of floor exhaust system using computational fluid dynamics for subway platform (수치해석을 활용한 승강장 바닥배기 시스템 최적화 연구)

  • Namgung, Hyeong-Gyu;Park, Sechan;Kim, Minhae;Kim, Soo-Yeon;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.443-449
    • /
    • 2017
  • The imbalance of air supply and the exhaust on subway platforms has led to the installation of platform screen doors in underground subway stations. This imbalance causes the accumulation of pollutants on the platform and loss of comfort due to the lack of ventilation. In this study, a floor exhaust system was optimized using computational fluid dynamics (CFD) and an optimization program. The optimized floor exhaust system was manufactured and tested experimentally to evaluate the particle collection efficiency. CFX 17.0 and HEEDS were used to analyze the flow field and optimize the principal dimensions of the exhaust system. As a result of the three-step optimization, the optimized floor exhaust system had a total height of 1.78 m, pressure drop of 430 Pa, and particle collection capability of 61%. A fine dust particle collection experiment was conducted using a floor exhaust system that was manufactured at full scale based on the optimized design. The experiment indicated about 65% particle collection efficiency. Therefore, the optimized design can be applied to subway platforms to draw in exhaust air and remove particulate matter at the same time.

A Study on the Acute Effects of Eine Particles on Pulmonary Function of Schoolchildren in Beijing, China (봄철 미세분진이 북경시 아동 폐기능에 미치는 급성영향에 관한 연구)

  • 김대선;유승도;차정훈;안승철;차준석
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.140-148
    • /
    • 2004
  • To evaluate the acute effects of fine particles on pulmonary function, a longitudinal study was conducted. This study was carried out for the schoolchildren (3rd and 6th grades) living in Beijing, China. Each child was provided with a mini-Wright peak flow meter and a preformatted health symptom diary for 40 days, and was trained on their proper use. Participants were instructed to perform the peak flow test three times in standing position, three times a day (9 am, 12 pm, and 8 pm), and to record all the readings along with the symptoms (cold, cough, and asthmatic symptoms) experienced on that day. Daily measurement of fine particles (PM$_{10}$ and PM$_{2.5}$) was obtained in the comer of the playground of the participating elementary school for the same period of this longitudinal study. The relationship between daily peak expiratory flow rate (PEFR) and fine particle levels was analyzed using a mixed linear regression models including gender, height, the presence of respiratory symptoms, and daily average temperature and relative humidity as extraneous variables. The total number of students participating in this longitudinal study was 87. The range of daily measured PEFR was 253-501$\ell$/min. In general, the PEFR measured in the morning was lower than the PEFR measured in the evening (or afternoon) on the same day. The daily mean concentrations of PM$_{10}$ and PM$_{2.5}$ over the study period were 180.2$\mu\textrm{g}$/㎥ and 103.2$\mu\textrm{g}$/㎥, respectively. The IQR (inter-quartile range) of PM$_{10}$ and PM$_{2.5}$ were 91.8$\mu\textrm{g}$/㎥ and 58.0$\mu\textrm{g}$/㎥. During the study period, the national ambient air quality standard of 150$\mu\textrm{g}$/㎥ (for PM$_{10}$) was exceeded in 23 days (57.5%). The analysis showed that an increase of 1$\mu\textrm{g}$/㎥ of PM$_{10}$ corresponded to 0.59$\mu\textrm{g}$/㎥ increment of PM$_{2.5}$. Daily mean PEFR was regressed with the 24-hour average PM$_{10}$ (or PM$_{2.5}$) levels, weather information such as air temperature and relative humidity, and individual characteristics including gender, height, and respiratory symptoms. The analysis showed that the increase of fine particle concentrations was negatively associated with the variability in PEFR. The IQR increments of PM$_{10}$ or PM$_{2.5}$ (at 1-day time lag) were also shown to be related with 1.54 $\ell$/min (95% Confidence intervals: 0.94-2.14) and 1.56$\ell$/min (95% CI: 0.95-2.16) decline in PEFR.R.ine in PEFR.ine in PEFR.

Dispersion of Particle Pulse in Human Lung Airway (인체기관지내의 입자펄스 확산 실험)

  • 이진원;이동엽;추경호
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.511-518
    • /
    • 1998
  • In order to develop the aerosol bolus technique which is thought to be a potential tool for probing geometries or abnormalities of small airways, an experimental system of measuring fast time variations of particle concentration in the inhaled and exhaled breathing air was developed. The system generates monodisperse sebacic acrid particles of 1 micron size and 1.2 of geometric standard deviation in high concentration of $10^8$ particles/cc, delivers a short pulse of particles at the controlled instant during inhalation using a solenoid valve, and measures the fast change of particle concentration in using the laser light scattering. Successful operation of the generator and the measuring system was confirmed by smooth concentration profiles in inhalation. It was also confirmed that maintaining a constant breathing rate is essential to stable outputs and any disturbance in flow rate near the mode (maximum concentration) induces a large number of spurious peaks in the exhalation. Experimental data without strict control of breathing flow rate showed a substantial amount of scatter. The measured results showed an improvement in scatter over the existing results. When compared with theoretical predictions from 1-D convective diffusion equation and other experiments, general characteristics of dispersion for several penetration depths showed a good agreement, but there exists some difference in absolute values, which is attributed to the difference in body conditions. Improvements are needed in the theory, especially in relation to correcting for the effect of breathing flow rate.

  • PDF

Study on Discharge Electrode Design applied for Road Tunnel (터널용 전기집진시스템 개발을 위한 방전극 설계)

  • Kim, Jong-Ryul;Weon, Jong-Oung;Jang, Chun-Man
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1238-1243
    • /
    • 2009
  • As Social Overhead Capital(SOC) has been expanded, the highway road construction has been accelerated and city road system has been more complicated. So, long road tunnels have been increased and traffic flow rate also has been raised. Accordingly, the exhausting gas of vehicle cars seriously deteriorates the tunnel inside air quality and driving view. In order to improve tunnel inside air quality, it is needed to introduce a compulsory ventilation system as well as natural ventilation mechanism. The former, that is, a special compulsory ventilation facility is very useful and helpful to prevent a tunnel of being contaminated by traffic in most case. In the case of obtaining clearer and longer driving view, the ventilation systems have to be considered in order to remove floating contaminants or exhaust gas from engines. In this paper, discharge electrode design technology will be discussed.

  • PDF

Comparison of particle removal efficiency between the physical cleaning methods in the fabrication of liquid crystal displays (LCD 제조공정에서 물리적 세정법의 미립자 제거효율 비교 연구)

  • Park, Chang-Beom;Yi, Seung-Jun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.795-801
    • /
    • 2010
  • As the fabrication technology of LCDs (Liquid Crystal Displays) advances, the size of mother glass substrates is getting larger, and the fabrication process is becoming finer. Accordingly, the importance of cleaning processes grows in the fabrication process of LCDs. In this study, we have compared and evaluated the particle removal efficiency for three different methods of physical cleaning, which are brush, bubble jet, and aqua/air cleaning. Using the seventh generation glass substrate, the particle removal efficiency has been investigated by changing operation conditions such as a flow rate of deionized water, pressure, contact depth between a brush bristle and a glass substrate, and so forth. In the case of brush cleaning, the cleaning efficiency barely changes after a critical point when the contact depth is varied. While the cleaning efficiency of bubble jet cleaning is almost independent of pressure, that of aqua/air cleaning is affected by pressure up to a critical point, but is not changed after it. We note the brush cleaning is the most effective among the three cleaning methods under our experimental conditions.

DEVELOPMENT OF A NUMERICAL SIMULATION METHOD FOR THE ANALYSIS OF SLOSHING PROBLEMS BASED ON CCUP SCHEME (슬로싱 해석을 위한 CCUP 기반 시뮬레이션 기술 개발)

  • Park, J.C.;Hwang, S.C.;Jeong, S.M.
    • Journal of computational fluids engineering
    • /
    • v.16 no.2
    • /
    • pp.1-10
    • /
    • 2011
  • A new computational program, which is based on the CIP/CCUP(Constraint Interpolation Profile/CIP Combined Unified Procedure) method, has been developed to numerically analyse sloshing phenomena dealt as multiphase-flow problems. For the convection terms of Navier-Stokes equations, the RCIP(Rational function CIP) method was adopted and the THINC-WLIC(Tangent of Hyperbola for Interface Capturing-Weighted Line Interface Calculation) method was used to capture the air/water interface. To validate the present numerical method, two-dimensional dam-breaking and sloshing problems in a rectangular tank were solved by the developed method in a stationary Cartesian grid system. In the case of sloshing problems, simulations by using a improved MPS(Moving Particle Simulation) method, which is named as PNU-MPS(Pusan National University-MPS), were also carried out. The computational results are compared with those of experiments and most of the comparisons are reasonably good.

Characterization of Fine Dust Collection Using a Filter Ventilation (환기장치와 필터를 활용한 미세먼지 제거특성 조사)

  • Jeon, Tae-Yeong;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • v.26 no.2
    • /
    • pp.229-233
    • /
    • 2015
  • In this study, we examined the removal characteristics of suspended particulate matters which are one of carcinogens to cause lung cancer. The fine dust capture by a pilot scale filtration system depends on several important variables such as humidity, initial fine dust injection volume, and flow rate. The average concentration of particulate matters in the test chamber decreased, but the ultimate collection efficiency did not change during the filtration under high humidity, compared to those of using ambient conditions The initial injection amount of fine dust did not influence the particle capturing efficiency. When the flow rate reduced from 0.6 m/s to 0.3 m/s, the dust collection time increased approximately 1.4 times. Among all variables tested, the flow rate showed the most significant effect on the removal efficiency of fine particulate matter.

Production of Carbonized Rice Husk by a Cyclone Combustor(II) (사이클론 연소기를 이용한 탄화왕겨의 제조(II))

  • 김원태;노수영
    • Journal of Biosystems Engineering
    • /
    • v.24 no.6
    • /
    • pp.487-492
    • /
    • 1999
  • One of effective utilization method of rice husk is to utilize it as culture material by carbonizing the rice husk. As a second part of a series to investigate the effective and continuous production of carbonized rice husk by a cyclone combustor, a non-slagging vertical cyclone combustor without vortex collector pocket was introduced. Isothermal and mixed firing with LPG and rice husk were undertaken in order to characterize the system. Inert rice husk was used during the isothermal test to find mass of rice husk collected. It was impossible to ignite rice husk itself over the experimental conditions considered in this experiment. Cyclone combustor was operated at temperatures of 1,273~1,473K. Detailed combustion data were obtained from a pilot unit with the air flow rate of 70m$^3$/h and rice husk feed of 2kg. The equivalence ratio ranged from 0.66 to 3.48. The auxiliary gas flow rate was varied from 3.22 to 12.86$\ell$/min. The weight reduction, pH and particle size distribution of carbonized rice husk were measured to evaluate the quality of carbonized rice husk. An analysis of exhaust gas emission was conducted to characterize the combustor. The required carbonized rice husk could be obtained at equivalence ratio of 1.68~2.17, combustor temperature of 1,273~1,373K and auxiliary gas flow rate of 3.22~6.43$\ell$/min. A method to reduce CO emissions should be employed.

  • PDF

Design of Optimal Vane Control for Ceiling Type Indoor Unit by PIV measurements (천장형 실내기의 기류 가시화를 통한 최적 제어 설계)

  • Sung Jaeyong;An Kwang Hyup;Lee Gi Seop;Choi Ho Seon;Park Seung-Chul;Lee In-Seop
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.533-536
    • /
    • 2002
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated using a PIV(particle image velocimetry) system For the PIV measurements, an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number, which is generally used in case that the forced convection has the similar magnitude as the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, the experimental results show that it should be less than $30^{\circ}$ to avoid re-suction flows which decrease the performance of the air-conditioner. At the vane angle of $30^{\circ}$, applying open/close control gives nae to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for the thermal comfort.

  • PDF