• Title/Summary/Keyword: Air-meter

Search Result 267, Processing Time 0.029 seconds

Thermal Conductivity Enhancement of Bentonite Grout Using Silica Sands (실리카샌드 첨가에 의한 벤토나이트 그라우트의 열전도도 증가)

  • Sohn, Byong-Hu
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.713-718
    • /
    • 2006
  • This paper concerns the measurement of thermal conductivity of grouting materials for ground loop heat exchanger. A thermal conductivity meter, QTM-500 based on modified transient hot wire method was used to measure the thermal conductivity of neat bentonite and mixtures of bentonite and various additives. Relative to the total mixture mass, as the percent additive was increased the mixture thermal conductivity increased. For the bentonite-silica sand mixtures, the higher density of the sand particles resulted in much higher mixture thermal conductivity.

  • PDF

Preparation and Characterization of Stretch Fabric : Shrinkage and Elasticity Properties (신축성사 개발 및 물성평가 : 수축률 및 신축성의 평가)

  • Kang, Ki-Hyuk;Kim, Young-Sung;Son, Young-A
    • Textile Coloration and Finishing
    • /
    • v.22 no.2
    • /
    • pp.173-179
    • /
    • 2010
  • In this study, we determine the stretch and shrinkage properties of conjugated yarns. The shrinkage(%) and elasticity(%) were determined by applying twist conditions of 0, 350, 800, 1000, 1200, 1400, 1600, 2000 T/M (twisting per meter). It is found that the shrinkage(%) and elasticity(%) gradually decreased with increasing T/M. Especially the elasticity(%) dramatically decreased over 1400 T/M condition. In contrast, it is showed that the handle and drapery properties decreased below 1000 T/M, which indicates that the optimal T/M condition could be 1000~1400. The effect of shrinkage(%) and elasticity(%) with different steam setting temperatures (60, 70, 80 and $90^{\circ}C$) was also determined. The shrinkage(%) decreased with increasing setting temperature, while the elasticity not changed. In this context, the optimal steam setting temperature could be $80^{\circ}C$ because it is not easy to weave with the yarns which was set below $80^{\circ}C$. The elasticity(%) decreased with increasing the density of warp and weft. To produce soft handle, excellent drapery and good stretch fabrics, the warp density needs to be reached by 90% of the ideal warp density. In the case of NaOH treatments to the fabrics, the elasticity(%) increased with increasing weight reduction. Therefore, this study have demonstrated that the conjugated yarns with core yarn and the SDY CD(cation dyeable spindraw yarn) as an effect yarn would be appropriate to produce excellent mixture-yarn, which displays clean appearance, good handle and excellent elasticity, The optimized conditions are as follows; 1000~1200 twist per meter, $80^{\circ}C$ steam setting temperature, 90% of ideal warp density and relaxation condition treated with 5g/l NaOH concentration.

Derivation of Relation between Variation of Gradients of Antenna Tower of GNSS Permanent Observatories Depending on Diurnal Variation of External Air Temperature and Movement of Phase Center of Antenna (바깥 공기 온도의 일변화에 의한 GNSS 상시관측소 안테나탑 기울기 변화와 안테나 위상중심 위치의 운동 사이의 관계 추출)

  • Lim, Mu-Taek;Kwak, Byung-Wook;Park, Yeong-Sue;Rim, Hyoung-Rae
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.2
    • /
    • pp.208-214
    • /
    • 2009
  • Using the GNSS data and tilt-meter data of Boeun (BOEN) and Goesan (GSAN) GNSS stations, we have calculated the differential distance vector variation with the calculation time span set to 1 hour and 3 hour and differential tilt vector variation along time and derived an indicator of similarity between the two variations along time. The similarity such calculated is rather lower than high. But as the existence of a circular type movement of the antenna's phase center's location due to the tilt's variation of the antenna tower because of the sunlight's diurnal change is certain, we recommend to take such diurnal variation of antenna's location into consideration when the correction error in DGNSS or the measured data at reference stations in VRS (Virtual Reference System) is broadcast.

Characteristics of Variant Dielectric Constants With Respect to Internal Combustion Engine Oil States (내연기관의 엔진오일상태에 대한 유전율 변화 특성)

  • Kim, Dong-Min;Kim, Yong-Ju;Lee, Seung-Hee
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.1
    • /
    • pp.19-21
    • /
    • 2012
  • The engine oil life of internal combustion engine is shorted by the thermal effect and that causes air pollution. In order to measure the status of engine oil accurately, the exchange of new oil extends the life of combustion engine and reduces environmental pollution. Capacitance probes, such as engine oil and fluids can be used to measure the dielectric constant. In this paper, the degradation of engine oil varies depending on the degree of dielectric properties was analyzed. Depending on the state of the oil, the variant capacitance of the probe was measured by LCR Meter, respectively, and then the permittivity of oil was calculated. In addition, according to the size of the probe by measuring the change in capacitance measurement, accuracy of dielectric constant are presented. According to oil contaminated with the more increase in dielectric constant, we can decide that contaminated oil is available.

A Simple Method for Measuring the Immobilization Solids of Coating Colors Using an AA-CWR Water Retention Meter

  • Park, Chang-hak;Lee, Do-Ik;Margaret K. Joyce
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.5
    • /
    • pp.39-48
    • /
    • 2002
  • The water retention of coating colors can be accurately measured by devices such as an AA-GWR water retention meter whose principle of measurement Is based on pressure filtration of coatings under an externally applied air pressure over a certain period of time. It was hypothesized that such devices could be also used to determine the immobilization solids (IMS) of coating colors by determining a sudden drop in the rate of dewatering, that is, a sudden change in the drainage curves. To test this hypothesis, the immobilization solids of coating colors containing various thickeners and water retention additives at different levels were first accurately measured by a modified immobilization tester based on the well-known gloss drop method, and then their values were compared with those obtained by an AA-GWR water retention tester. They agreed very well and showed that the standard deviation is only 0.14% in the IMS points between both methods. This good agreement was not surprising because both test methods are based on the same end-point, that is, the immobilization solids point at which menisci begin to form at the coating surface. Theoretical considerations supporting this new method for measuring the immobilization solids of coating colors are presented and some recommendations for the test method are discussed. Also, the effect of various thickeners and water retention additives on the properties and printability of coated papers is discussed.

Development of Day Fog Detection Algorithm Based on the Optical and Textural Characteristics Using Himawari-8 Data

  • Han, Ji-Hye;Suh, Myoung-Seok;Kim, So-Hyeong
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.1
    • /
    • pp.117-136
    • /
    • 2019
  • In this study, a hybrid-type of day fog detection algorithm (DFDA) was developed based on the optical and textural characteristics of fog top, using the Himawari-8 /Advanced Himawari Imager data. Supplementary data, such as temperatures of numerical weather prediction model and sea surface temperatures of operational sea surface temperature and sea ice analysis, were used for fog detection. And 10 minutes data from visibility meter from the Korea Meteorological Administration were used for a quantitative verification of the fog detection results. Normalized albedo of fog top was utilized to distinguish between fog and other objects such as clouds, land, and oceans. The normalized local standard deviation of the fog surface and temperature difference between fog top and air temperature were also assessed to separate the fog from low cloud. Initial threshold values (ITVs) for the fog detection elements were selected using hat-shaped threshold values through frequency distribution analysis of fog cases.And the ITVs were optimized through the iteration method in terms of maximization of POD and minimization of FAR. The visual inspection and a quantitative verification using a visibility meter showed that the DFDA successfully detected a wide range of fog. The quantitative verification in both training and verification cases, the average POD (FAR) was 0.75 (0.41) and 0.74 (0.46), respectively. However, sophistication of the threshold values of the detection elements, as well as utilization of other channel data are necessary as the fog detection levels vary for different fog cases(POD: 0.65-0.87, FAR: 0.30-0.53).

Oxygen Transfer and Hydraulic Characteristics in Bubble Column Bioreactor Applied Fine Bubble Air Diffusing System (미세기포 산기장치를 적용한 타워형 생물반응기의 산소전달 및 수력학적 특성)

  • Lee, Seung-Jin;Ko, Kyeong-Han;Ko, Myeong-Han;Yang, Jae-Kyeong;Kim, Yong-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.11
    • /
    • pp.772-779
    • /
    • 2012
  • For improving performance of conical air diffuser generating fine bubble, both experimental and numerical simulation method were used. After adapting diffusers inner real scale bubble column, suitable for various diffuser submergence, the effect of diffuser submergence on oxygen transfer performance such as Oxygen Transfer Coefficient ($K_{L}a_{20}$) and Standard Oxygen Transfer Efficiency (SOTE) was investigated empirically. As flow patterns for various diffuser number and submergence were revealed throughout hydrodynamic simulation for 2-phase fluid flow of air-water, the cause of the change for oxygen transfer performance was cleared up. As results of experimental performance, $K_{L}a_{20}$ was increased slightly by 7% and SOTE was increased drastically by 39~72%, 5.6% per meter. As results of numerical analysis, air volume fraction, air and water velocity in bioreactor were increased with analogous flow tendency by increasing diffuser number. As diffuser submergence increased, air volume fraction, air and water velocity were decreased slightly. Because circulative co-flow is determinant factor for bubble diffusion and rising velocity, excessive circulation intensity can result to worsen oxygen transfer by shortening bubble retention time and amount.

Comparing the Effects of Ventilation and Air Purification Plants on Radon Concentration in the Lower and Upper Floors of a Building (건물 저층과 고층에서 환기와 공기정화 식물을 통한 라돈 농도의 비교)

  • Gong, Yu-jin;Nam, So-Yeong;Shin, Min-Seo;Jang, Hey-Rim;Jeon, Min-Cheol;Yoo, Se-Jong;Kim, Seong-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.881-889
    • /
    • 2020
  • The objective of this study was to quantitatively measure the changes in radon concentration due to ventilation and air purification plants in the lower and upper floors of a building. This study measured and compared radon concentration in the lower and upper floors of the building by using a radon meter when the room was closed, it was ventilated, and air purification plants were installed at a specific time. One-way ANOVA was conducted to evaluate the effect of treatment (i.e., closure, ventilation, and air purification plants) on radon concentration. The results of this study showed that ventilation and air purification plants significantly decreased radon concentration in the lower and upper floors of the building, but the effect of ventilation and that of air purification plants were not significantly different. Therefore, it will be possible to reduce radon concentration effectively when ventilation and air purification plants are used appropriately.

Technology development on localization of BOP components for 1kW stationary fuel cell systems to promote green-home dissemination project (그린홈 보급확대를 위한 건물용 연료전지 보조기기 국산화 기술개발)

  • Kim, Minseok;Lee, Sunho;Jun, Heekwon;Bea, Junkang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.128.2-128.2
    • /
    • 2010
  • For stationary 1kW-class fuel cell systems to be used widely, it is essential to achieve dramatic improvements in system durability as well as cost reduction. In order to address this engineering challenge, it is important to develop innovative technologies associated with BOP components. According to this background, in 2009, the Korean Government and "Korea Institute of Energy Technology Evaluation and Planning(KETEP)" launched into the strategic development project of BOP technology for practical applications and commercializations of stationary fuel cell systems, named "Technology Development on Cost Reduction of BOP Components for 1kW Stationary Fuel Cell Systems to Promote Green-Home Dissemination Project". The objectives of this project are to develop fundamental technologies to meet these requirements, and to improve the performance and functionality of BOP components with reasonable price. The project consortium consists of Korea's leading fuel cell system manufacturers, BOP component manufacturers which technologically specialized, and several research institutions. This paper is to provide a summary of the project, as well as the achievements made through the 1st period of the project(2009~2010). Several prototypes of BOPs - Cathode air blowers, burner air blowers, preferential oxidation air blowers, fuel blowers, cooling water pumps, reformer water pumps, heat recovery pumps, mass flow meters, valves and power conditioning systems - had been developed through this project in 2010. As results of this project, it is expected that a technological breakthrough of these BOP components will result in a substantial system cost reduction.

  • PDF

Experimental Study on the Characteristics of Heat and Mass Transfer on the Teflon Coated Tubes (테프론 코팅 전열관 표면으로의 열 및 물질 전달 특성에 관한 실험적 연구)

  • Lee, Jang-Ho;Kim, Hyeong-Dae;Kim, Jung-Bae;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1051-1060
    • /
    • 2003
  • The heat and mass transfer on two kinds of tube surfaces (bare stainless steel tube and Teflon coated tube) in steam-air mixture flow are experimentally studied to obtain design data for the heat exchanger of the latent heat recovery from flue gas. In the test section, 3-tubes are horizontally installed, and steam-air mixture is vertically flowed from the top to the bottom. The pitch between tubes is 67mm, the out-diameter of tube is 25.4mm, and the thickness is 1.2mm ; blockage factor (cross sectional tube area over the cross sectional area of the test section) is about 0.38. All of sensors and measurement systems (RTD, pressure sensor, flow-meter, relative humidity sensor, etc.) are calibrated with certificated standard sensors and the uncertainty for the heat transfer measurement is surveyed to have the uncertainty within 7%. As experimental results, overall heat transfer coefficient of the Teflon (FEP) coated tube is degraded about 20% compared to bare stainless tube. The degradation of overall heat transfer coefficient of Teflon coated tube comes from the additional heat transfer resistance due to Teflon coating. Its magnitude of heat transfer resistance is comparable to the in-tube heat transfer resistance. Nusselt and Sherwood numbers on Teflon (FEP) coated surface and bare stainless steel surface are discussed in detail with the contact angles of the condensate.