고층 건물의 실외기실에 위치한 응축기 성능분석 (Analysis of the Condenser Performance Installed in the Air-Conditioning Plant Room of a High-Rise Building)

  • 최석호;이관수;김병순
    • 설비공학논문집
    • /
    • 제15권7호
    • /
    • pp.586-594
    • /
    • 2003
  • The performance of the condenser installed in the air-conditioning plant room of a high-rise building was studied numerically. The effect of the draft direction on the performance of an air-conditioner was analyzed. The on-coil temperature of the condenser was investigated by varying the arrangement and location o( the condenser in the air-conditioning plant room. The performance of an air-conditioner was also evaluated by using COP (coefficient of performance) and CGPI (condenser group performance indicator). The condenser in an air-conditioning plant room should be arranged in such a manner that the fan of the condenser is facing the outside of the building to exhaust the hot air directly, The model by which the condenser is located at the lower-left end of an air-conditioning plant room can prevent the hot air from reentering, and allow indrafting of fresh air. When the direction of draft is to the frontal face of the building, the performance of the condenser above 30th floor is degraded.

비상시 열원중단에 따른 데이터센터의 냉각시스템 열성능 평가에 관한 사례연구 (A Study on Thermal Analysis for a Data Center Cooling System under Fault Conditions at a Chilled Water Plant)

  • 조진균;강호석
    • 설비공학논문집
    • /
    • 제28권5호
    • /
    • pp.178-185
    • /
    • 2016
  • This study describes the analysis of a 20 MW chilled water plant used for the IT cooling of a recently constructed data center in Korea. The CFD model was developed with the aim of evaluating the impact of problems such as chiller failure on the water and air temperatures in the cooling system. The numerical model includes the chilled water hydraulic network and individual water-to-air CRAC units. The coupling between the IT server room air temperature levels and the cooling plant has enabled a full assessment of the cooling system design in response to system fault conditions to be performed. The paper examines an emergency situation involving the failure of the cooling plant, and shows how the inherent thermal inertia of the system along with additional inertia achieved through buffer systems allowed a suitable design to be achieved.

빙축열을 이용한 저온공조시스템 운전 특성 연구 (Study on operation characteristics of the cold air distribution systems with an ice storage tank)

  • 염한길;박병규;고득용
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.301-312
    • /
    • 1999
  • Experiments were carried out to evaluate performance of the cold air distribution systems with an ice storage tank in test room. Cold air distribution systems provide primary air for comfort conditioning or process cooling at coil discharge temperatures$4^{\circ}C$ to$11^{\circ}C$. The application of a cold air distribution system allows for the downsizing of air distribution equipment and central plant equipment when ice storage tank is used. The benefit of a cold air distribution system include a decrease in the floor-to-floor height, increase floor space, reduced building capital costs, reduced energy use and demand. The use of cold air distribution can result in the most cost effective system and is currently being implemented world wise as the new standard in air conditioning systems. In this study, the cold air distribution system is compared with the general ice storage system. Under the same cooling load conditions, experimental results show that the supply air volume of cold air distribution system decrease 38%, and decrease 45% flow rate of brine for the general ice storage system.

  • PDF

국내 원자력발전소의 주제어실 화재 피난 리스크 평가를 위한 화재 시뮬레이션 (Fire Simulations for the Abandonment Risk Assessment of Main Control Room Fire in Domestic Nuclear Power Plant)

  • 강대일;김길유;장승철;유성연
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.199-207
    • /
    • 2014
  • In this paper, to systematically assess the abandonment risk of main control room (MCR) fire, fire simulations with Fire Dynamics Simulator were performed and abandonment probabilities were estimated for the MCR bench-board fire of domestic reference nuclear power plant. The fire simulation scenarios performed in this study included propagating and non-propagating fires of the MCR bench-board, and the availability and unavailability of heating, ventilation, and air conditioning system (HVACS). The following results were obtained. First, temperature was the major abandonment impact factor for the MCR bench-board fire if the HVACS was available and optical density was that if the HVACS was unavailable. Second, the fire scenario contributing the MCR bench-board fire abandonment risk was identified to be only the propagating fire. Third, it was confirmed that the abandonment probability of the MCR bench-board fire for domestic reference nuclear power plant could be reduced by using the fire modeling.

가청화를 이용한 댐 수차 발전기소음의 저감효과 평가 (Evaluation on Reduction Effect about Noise of Hydraulic Turbine Dynamo in Dam using Auralization)

  • 설수환;주덕훈;김재수
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.400-408
    • /
    • 2008
  • Multipurpose Dam, it produces electric energy by converting the potential energy into kinetic energy utilizing its head and quantity of the water. However, in this process, since during the time when the turbine connected to the hydraulic turbine generator revolves, there occurs a ceaseless loud noise, and due to this condition, it is true state that those people who work at inside of the power plant are damaging as hard as they are unable to concentrate on their work. Not only this, because the hydro-electric power generator room that locates at middle section between the hydraulic turbine room and the office is very large space volume, also since it was constructed chiefly by the reflecting material, it is functioning of amplify the noise when operating the generator, the soundproof measure against this condition is necessitated. On such viewpoint, I have presented the problem point of the relevant Hydraulic turbine dynamo and Hydraulic turbine dynamo room, and after improve such problem point, this study has ever investigated the satisfying degree about the noise-reduction at before and after of the improvement of soundproof measure, using the Auralizational technique that can experience virtual acoustic field. It is considering that such result could be utilized usefully as the fundamental material hereafter for the acoustic performance of the hydro-electric power generator room in dam and when its construction.

지역난방 2차측 유량변화가 내부 열유속 및 에너지소비량에 미치는 영향에 관한 실험적 연구 (The Experimental Study of the Heat Flux and Energy Consumption on Variable Flow Rate for Secondary Side of DHS)

  • 홍성기;조성환
    • 설비공학논문집
    • /
    • 제27권5호
    • /
    • pp.247-253
    • /
    • 2015
  • The presented work demonstrates the effects of flow rate on the secondary side of DHS (District Heating System). Increasing flow rate at the secondary side of DHS decreases energy consumption and time to reach the set-point of the heated room while increasing heat flux on the floor in the heating space. When flow rate increases, the overall heat transfer rate of radiant floor also increases. However, the results also show overall heat transfer rateto not increased linearly and thus the existence of an optimal flow rate for the secondary side of DHS. Control of the radiant floor with hot water may be more effectively accomplished with a combined control strategy that includes heat flux and a temperature set-point. This experimental analysis has been performed using a lab-scaled DHS pilot plant located at Jeonju University in Korea.

냉동기 고장경향분석을 통한 설비신뢰도향상 방안 제시 (The Suggestion of Reliability Improvement Method based on Failure Trend Analysis of Chiller)

  • 이상대;염동운;현진우
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.251-255
    • /
    • 2015
  • Chiller system plays an important role of maintaining room temperature constantly by supplying chilled water to Heating, Ventilating and Air Conditioning(HVAC)or area room cooler equipment during plant normal operation or accident condition. Chiller failures are one of the most frequently occurring equipment failures. If the types of chiller failures are analyzed and grouped thoroughly, it would be helpful to make chiller maintenance strategy at the plants. That would enhance equipment reliability of chiller in the end. In this paper, chiller failure data during three years were analyzed and categorized by specific failure code. In addition, the various proposals to improve equipment reliability of chiller were suggested such as Preventive Maintenance Optimization(PMO) strategy and performance monitoring reinforcement and so on.

난방용 자동온도조절기 성능분석용 프로그램 및 패키지 개발 (A Development of the Performance Analysis Program Package of the Automatic Temperature Control System for Heating)

  • 김용기;우남섭;이태원;안병천
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1209-1214
    • /
    • 2009
  • Various automatic temperature control systems have been used widely in Korea for the conservation of heating energy and the enhancement of thermal comfort in residential buildings. But the heating control performance for automatic temperature control systems extensively vary with the design and operational conditions of the heating system, the climate condition and others. It was introduced in this study a numerical calculation program package to analyze heating control characteristics of the automatic temperature control system. This package is able to analyze the room air temperature, return water temperature, supplied heating flux and flow rate, and so on. One the other hand, the simulation results were verified by comparing with the field test results.

  • PDF

원자력발전소 주제어실 공기조화계통 기능적설비그룹 개발 (FEG Development of MCR HVAC System for NPP)

  • 현진우
    • 한국압력기기공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.21-25
    • /
    • 2012
  • Functional Equipment Group(FEG) of Nuclear Power Plant(NPP) is the bundling of multiple equipment subcomponents around a major equipment with a common system isolation characteristic or out-of-service consideration. The main purpose of FEG is to reduce out-of-service time to enhance maintenance effectiveness. KHNP(Korea hydro & Nuclear Power Co.) needs to develop these FEGs to successfully perform On-line Maintenance(OLM) which will be expected to institute in the future. Recently, there has been growing interest in OLM in KHNP. The aim of this paper is to suggest the way of FEG development and to build the FEG of MCR(Main Control Room) HVAC(Heat, Ventilation and Air Conditioning) system. The results of this study might be make good use of OLM and be helpful for equipment maintenance for MCR HVAC system.

청소년 수련관의 열원설비 대안별 생애주기 비용에 관한 연구 (Analysis of Life Cycle Cost for Heat Source Equipments in Buildings for Adolescent Trainees)

  • 안창환;방승기;백용규
    • KIEAE Journal
    • /
    • 제5권3호
    • /
    • pp.25-31
    • /
    • 2005
  • Computer simulations were performed for Heating Ventilating and Air-Conditioning (HVAC) systems to figure out more efficient maintenance methods for the building used for adolescent trainees. This study aims at suggesting design alternatives for optimum operation and performing life cycle cost (LCC) for each alternative. First, the capacity of the heat source equipment was determined using annual maximum heating and cooling loads. Annual loads were calculated and applied to the alternative for the purpose of calculating annual energy cost. Second, several types of data were collected to predict energy cost. Finally, the pay back period for each alternative was calculated using total cost estimation during standard duration period. This study indicates that the absorption chiller that does not occupy most part of a mechanical room, and does not need much operation cost was most economical.