• Title/Summary/Keyword: Air-conditioning design

Search Result 1,311, Processing Time 0.024 seconds

A Study on Architectural Planning of Establishing Air-Conditioning Zoning for Hospital Design Focused on System (체계중심병원설계를 위한 공조조닝 설정의 건축 계획에 관한 연구)

  • Kim, Eun Seok;Yang, Nae Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.3
    • /
    • pp.29-38
    • /
    • 2018
  • Purpose: Space planning to cope with the changing function of the hospital is essential in hospital architecture. In order to do so, it is vital that the paradigm shifts from hospital design focused on purpose toward hospital design focused on system. Not only space planning but also air-conditioning plan, which is most closely related to the operation and maintenance of hospital facilities; and the environment of hospital users, should be able to respond to changes with ease. Thus this study is to provide fundamental data of the air-conditioning plan for the hospital design focused on system by analyzing the concept and characteristics of the air-conditioning plan in the recent hospital architecture planning. Results: As a result of this study, in the air conditioning plan for the hospital architecture planning, the most important are the location relation among the departments the air handling unit room and the air handling unit manage and the air conditioning zoning setting according to the air conditioning system. Therefore, for the hospital architecture planning focused on system, it is necessary to establish the air conditioning setting that can accommodate changeable environment of departments and accordingly the appropriate area range of the air conditioning zoning and the plan for the location of the air handling unit should be considered. Implications: Thereby aims to provide fundamental data on air handling unit zoning planning in the hospital architecture planning.

A Study on Weather Data for Air Conditioning Equipment Design Report I - Weather Data in Busan from 1970 through 2003

  • Kim Jong-Ryeol;Kum Jong-Soo;Choi Kwang-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • For the purpose of processing weather data for air conditioning equipment de sign in Busan area Korea, this study collected weather observations made by Busan weather Administration from 1970 to 2003, and then established external conditions for heating and air-conditioning design. For changes of temperature in external conditions for design, the highest temperature had little changed, whereas the lowest had been on the rise as the years went by through the 1970s, 1980s, 1990s, and 2000s, but insolation has a little lessened. Absolute humidity does not show a significant change but an incessant rise.

Study on the Outdoor Conditions for Air Conditioning Design in Korea (한국의 공기조화설계용 외기조건)

  • 김효경
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.1 no.1
    • /
    • pp.3-11
    • /
    • 1972
  • The outdoor design conditions for the locality are the basic problem in the design of air conditioning system. The ideal solution to the basic problem is to design a building that has a capacity at maximum output just equal to the load which develops the most severe conditions for the locality occur, but in most cases, economics interferes the attainment of the ideal. Studies of weather records show that the most severe conditions do not repeat themselves every year. The weather conditions of principal cities such as Seoul, Inchon, Suwon, Taegu, Chonju, Ulsan, Kwangju, Pusan and Mokpo in Korea have been analyzed to determine the probability of occurrence of certain temperatures according to recent 10 years $(1960\∼1969)$ weather records. The outdoor conditions for winter air conditioning design are shown on Table 2. The outdoor conditions for summer air condioning design are shown on Table 7. Heating degree days are shown on Table 10 and 11.

  • PDF

A Study on the Passive Principle and its Practical Application of Air-conditioning System (난방을 비롯한 공기조화의 자연조절 방식과 현대적 응용에 관한 고찰)

  • Park, Soon-Kwan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.2
    • /
    • pp.105-112
    • /
    • 2004
  • The objective of this study is to observe today's situation and direction in relation with the natural air-conditioning and heating system to expand the architectural utilization of natural management for human comfort and energy conservation in architectural design. Also this study to provide the fundamental knowledge and. design-techniques on environment-friendly architecture in connection with 'natural idea in architecture'. In accordance with this intention, this thesis is composed of the following contents : 1) to understand the fundermental concepts about natural air-conditioning and heating system, 2) to review the traditional characteristics in Korean and Southeast Asian architecture related to natural air-conditioning and heating system, 3) to examine modern design-techniques in relation with natural air-conditioning and heating system in the selected area, 4) to attempt to synthesize the whole situation. Environment-friendly architecture using natural ideas and design-techniques in architecture is very important architectural aspect in a current architecture, also for the future. In spite of general considerations, it is expected that this study is use to understand the principle and practical application of natural air-conditioning and heating system in architectural design.

Identification of target subjects and their constraints for automated MEP routing in an AEC project

  • Park, SeongHun;Shin, MinSo;Kim, Tae wan
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.776-783
    • /
    • 2022
  • Since Mechanical, Electrical, and Plumbing(MEP) routing is a repetitive and experience-centered process that requires considerable time and human resources, if automated, design errors can be prevented and the previously required time and human resources can be reduced. Although research on automatic routing has been conducted in many industries, the MEP routing in AEC projects has yet to be identified due to the complexity of system configuration, distributed expertise, and various constraints. Therefore, the purpose of this study is to identify the target subjects for MEP routing automation and the constraints of each subject. The MEP design checklist provided by a CM company and existing literature review were conducted, and target subjects and constraints were identified through process observation and in-depth expert interviews for five days by visiting a MEP design company. The target subjects were largely divided into six categories: air conditioning plumbing, air conditioning duct, restroom sanitary plumbing, heating plumbing, and diagram. The findings from interviews show that work reduction and error reduction has the greatest effect on air conditioning plumbing while the level of difficulty is the highest in air conditioning duct and restroom sanitary plumbing. Major constraints for each subject include preventing cold drafts on air conditioning pipes, deviation in ventilation volume in air conditioning ducts, routing order on restroom sanitary plumbing, and separation distance from the wall on heating plumbing. In this way, subjects and constraints identified in this study can be used for MEP automatic routing.

  • PDF

Frequency Response Characteristics of Air-Cooled Condenser in Case of Inputting Various Disturbances

  • Kim, Jae-Dol;Oh, Hoo-Kyu;Yoon, Jung-In
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.1
    • /
    • pp.14-28
    • /
    • 2000
  • The frequency response characteristics of a condenser were numerically studied for the control of refrigeration and air conditioning systems. The important parameters, such as the refrigerant flow rate, refrigerant temperature, air velocity, and air temperature at the condenser inlet, were analyzed. Superheated vapor, two phase, and subcooled liquid domain in condenser can be described by using the energy balance equation and the mass balance equation in refrigerant and tube wall, the basic equation for describing the dynamic characteristics of condenser can be derived. The transfer function for describing dynamic response of the condenser to disturbances can be obtained from using linearizations and Laplace transformations of the equation. From this transfer function, analytical investigation which affects the frequency responses of condenser has been made. Block diagrams were made based on the analytic transfer function; dynamic responses were evaluated in Bode diagrams on the frequency response. Through this study, it became possible that the information about the dynamic characteristics of air-cooled condenser is offered. The results may be used for determining the optimum design parameters in actual components and entire systems. Also, the mathematical models, frequency response may be used to help understanding, evaluate optimum design parameters, design control systems and determine on setting the best controller for the refrigeration and air-conditioning systems.

  • PDF

Design of Optimized Multi-Fuzzy Controllers by Hierarchical Fair Competition-based Genetic Algorithms for Air-Conditioning System (에어컨시스템에 대한 계층적 공정 경쟁 유전자 알고리즘을 이용한 최적화된 다중 퍼지제어기 설계)

  • Jung, Seung-Hyun;Choi, Jeoung-Nae;Kim, Hyun-Ki;Oh, Sung-Kwun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.4
    • /
    • pp.344-351
    • /
    • 2007
  • In this paper, we propose an approach to design multi-fuzzy controllers for the superheat and the low pressure that have an influence on energy efficiency and stabilization of air conditioning system with multi-evaporators. Air conditioning system with multi-evaporators is composed of compressor, condenser, several evaporators and several expansion valves. It is quite difficult to control the air conditioning system because the change of the refrigerant condition give an impact on the overall air conditioning system. In order to solve the drawback, we design multi-fuzzy controllers which control simultaneously both three expansion valve and one compressor for the superheat and the low pressure of air conditioning system. The proposed multi fuzzy controllers are given as a kinds of controller types such as a simplified fuzzy inference type. Here the scaling factors of each fuzzy controller are efficiently adjusted by Hierarchical Fair Competition-based Genetic Algorithms. The values of performance index of the simulation results of the A company type compare with simulation results of simplified inference type.

A Study on Area Planning of Air Conditioning Room for Hospital Design Focused on System (체계중심병원설계를 위한 공조실 면적 계획에 관한 연구)

  • Kim, Eun Seok;Yang, Nae Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.4
    • /
    • pp.27-35
    • /
    • 2019
  • Purpose: As the improvement in quality of medical environment and the spatial consideration for the prevention of infection in the hospital have become increasingly important in the recent years, specific and practical planning for air conditioning room's area has become a major issue accordingly. However, the air conditioning room tends to be discussed focusing on technical factors such as air conditioning systems that are irrelevant to building plans, while discussions of most departments related to the medical functions have actively taken placed. Therefore, this study aims to investigate the factors influencing the planning for the air conditioning room area, and through subsequent analysis of the area of the air conditioning room, to propose a way to improve effective planning for the air conditioning room area. Methods: This study examines the case hospitals that fall into two types: each floor supply system and concentrated supply system, and compares and analyzes the air conditioning room area-related factors and the characteristics of changes in the interior of air conditioning room before and after remodeling through air conditioning floor plan of those case hospitals. Results: The air conditioning room can be classified into the net area of the functional space such as duct passages, and the public area such as aisle space, and of those the public area is an important factor in calculating the area of the air conditioning room. The public area of the air-conditioning room should not be planned considering only the spaces for mobile passage or maintenance activities, but should be planned taking into account internal changes such as expansion and replacement of equipment in the future from the beginning. Implications: When planning a medical facility, it is used as basic data for the planning of the air conditioning room area, which is a significant fixed factor in the initial setting.