• Title/Summary/Keyword: Air-conditioning System

Search Result 3,314, Processing Time 0.03 seconds

The Construction Status of Fuel Test Loop Facility (핵연료 노내조사시험설비의 시공 현황)

  • Park, Kook-Nam;Lee, Chung-Young;Kim, Hark-Rho;Yoo, Hyun-Jae;Yoo, Seong-Yeon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.305-309
    • /
    • 2007
  • FTL(Fuel Test Loop) is a facility that confirms performance of nuclear fuel at a similar irradiation condition with that of nuclear power plant. FTL construction work began on August, 2006 and ended on March, 2007. During Construction, ensuring the worker's safety was the top priority and installation of the FTL without hampering the integrity of the HANARO was the next one. The installation works were done successfully overcoming the difficulties such as on the limited space, on the radiation hazard inside the reactor pool, and finally on the shortening of the shut down period of the HANARO. The Commissioning of the FTL is to check the function and the performance of the equipment and the overall system as well. The FTL shall start operation with high burn up test fuels in early 2008 if the commissioning and licensing progress on schedule.

  • PDF

A Study on the Performance and Flow Distribution of Fresh Water Generator with Plate Heat Exchanger

  • Jin, Zhen-Hua;Kim, Pil-Hwan;Lee, Gyeong-Hwan;Choi, Soon-Ho;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.611-617
    • /
    • 2008
  • Nowadays Plate Heat Exchanger (PHE) is widely used in different industries such as chemical, food and pharmaceutical process and refrigeration due to the efficient heat transfer performance, extreme compact design and efficient use of the construction material. In present study, discussed main conception of plate heat exchanger and applied in vacuum. PHE and aimed apply in the fresh water generator which installed in ship to desalinate seawater to fresh water use heat from engines. The experiment is proceeded to investigate the heat transfer between cold and hot fluid stream at different flow rate and supply temperature of hot fluid. Generated fresh water as outcome of the system. PHE is an important part of a condensing or evaporating system. One of common assumptions in basic heat exchanger design theory is that fluid is to be distributed uniformly at the inlet of each fluid side and throughout the core. However, in practice, flow mal-distribution is more common and can significantly reduce the heat exchanger performance. The flow and heat transfer are simulated by the k-$\varepsilon$ standard turbulence model. Moreover, the simulation contacted flow maldistribution in a PHE with 6 channels.

  • PDF

Coupled Thermal-Stress Analysis of Scrolls in Automotive Scroll Compressor (전동식 Scroll Compressor의 Scroll 열변형 해석)

  • Lee, Hyoung-wook;Kim, Jeongbae;Lee, Geun-An;Lee, Jong Sup;Lee, Young-Seon
    • Journal of Institute of Convergence Technology
    • /
    • v.2 no.1
    • /
    • pp.38-42
    • /
    • 2012
  • A scroll compressor used in the air conditioning in automobile consists of the fixed scroll and the orbiting scroll. Temperature gradient in the scroll compressor during the operation induces the thermal expansion of two scrolls. Therefore, the gap between scrolls in the initial stage is regarded as an important variable in structural design of the scroll compressor. The coupled thermal-stress analysis was carried out for the scrolls of a scroll compressor. The temperatures of major points of two scrolls in the steady states were referred by the literature of C. Lin. The sequentially coupled thermal-stress analysis is utilized to the heat transfer analysis and the thermal expansion analysis. In the thermal expansion analysis, the contact analysis was considered between the fixed and the orbiting scrolls in order to obtain the penetration distance and the contact pressure between two scrolls. The range of deformation was from 44 to $76{\mu}m$ according to the height of the scroll. The maximum penetration distance of $60{\mu}m$ occurred at the top surface of the fixed scroll in the center of the scroll parts.

  • PDF

Measurement of distribution stability of binary nanofluids by zeta-potential (Zeta-potential을 이용한 이성분 나노유체의 분산안정도 측정)

  • Lee, Kang-Il;Jung, Chung-Woo;Kim, Hyun-Jun;Joeng, Jin-Hee;Kang, Yong-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.52-57
    • /
    • 2006
  • This study investigates the distribution stability of binary nanofluids where binary mixtures such as $NH_3/H_2O$ and $H_2O/LiBr$ solution are used as a base fluid. When a little amount of certain nanosized particles is added into a basefluid, the thermal conductivity of that mixture increases greatly. Such mixtures are named 'nanofluids' where nano-particles should be distributed stably and uniformly so the distribution stability of nanoparticles in nanofluids is one of the most important factors for nanofluid application. Therefore, binary nanofluids in which binary mixtures are applied as the basefluids are considered as working fluids. The kind and the concentration of nanoparticles, and the concentration of ammonia are considered as the key parameters. The objectives of this paper are to visualize the dispersed status of particles in binary nanofluids and to find the effect of key parameters on the distribution stability in the ammonia absorption system.

  • PDF

The Decrease of Return Temperature by Improvement of the Consumer's Control System in District Heating (지역난방 열사용시설 자동제어시스템 개선을 통한 회수온도 저감 연구)

  • Ha, Seung-Kyu;Kim, Youn-Hong;Lee, Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.245-251
    • /
    • 2006
  • The main idea of this study is to turn attention on the question of good cooling ability of customer substations in large district heating networks. The main reason for that is based on our experience that the optimization of district heating very often is directed toward production, whereas questions of optimal distribution are neglected if only the necessary load can be supplied and the customer's request for comfort is met. Our view is that low return temperature(operational temperature differences, ${\Delta}T$) in district heating systems is an Important feature for efficient net operation and gives both economic and operational benefits to the district heating supplier Furthermore, it is as well a prerequisite for meeting the customers demand for reliable supply of the heat load. However, in many practical cases we have seen that district heating return temperatures are higher than necessary. Hence, the aim of the study is to propose and verify a method for detection of the most critical consumers of the net and to identify the reasons for resulting high return temperature. From the results, temperature control system is presented as one of the most important reason of high return temperature in DH networks.

  • PDF

Machine Learning Approach for Pattern Analysis of Energy Consumption in Factory (머신러닝 기법을 활용한 공장 에너지 사용량 데이터 분석)

  • Sung, Jong Hoon;Cho, Yeong Sik
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.8 no.4
    • /
    • pp.87-92
    • /
    • 2019
  • This paper describes the pattern analysis for data of the factory energy consumption by using machine learning method. While usual statistical methods or approaches require specific equations to represent the physical characteristics of the plant, machine learning based approach uses historical data and calculate the result effectively. Although rule-based approach calculates energy usage with the physical equations, it is hard to identify the exact equations that represent the factory's characteristics and hidden variables affecting the results. Whereas the machine learning approach is relatively useful to find the relations quickly between the data. The factory has several components directly affecting to the electricity consumption which are machines, light, computers and indoor systems like HVAC (heating, ventilation and air conditioning). The energy loads from those components are generated in real-time and these data can be shown in time-series. The various sensors were installed in the factory to construct the database by collecting the energy usage data from the components. After preliminary statistical analysis for data mining, time-series clustering techniques are applied to extract the energy load pattern. This research can attributes to develop Factory Energy Management System (FEMS).

Calculation of Required Coolant Flow Rate for Photovoltaic-thermal Module Using Standard Meteorological Data and Thermal Analysis (표준기상 데이터와 열해석을 이용한 태양광열 모듈의 필요 냉각수량 산출)

  • Lee, Cheonkyu;Jeong, Hyo Jae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.18-22
    • /
    • 2022
  • Photovoltaics (PV) power generation efficiency is affected by meteorological factors such as temperature and wind speed. In general, it is known that the power generation amount decreases because photovoltaics panel temperature rises and the power generation efficiency decreases in summer. Photovoltaics Thermal (PVT) power generation has the ad-vantage of being able to produce heat together with power, as well as preventing the reduction in power generation efficien-cy and output due to the temperature rise of the panel. In this study, the amount of heat collected by season and time was calculated for photovoltaics thermal modules using the International Weather for Energy Calculations (IWEC) data provided by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). Based on this, we propose a method of predicting the temperature of the photovoltaics panel using thermal analysis and then calculating the flow rate of coolant to improve power generation efficiency. As the results, the photovoltaics efficiencies versus time on January, April, July, and October in Jeju of the Republic of Korea were calculated to the range of 15.06% to 17.83%, and the maxi-mum cooling load and flow rate for the photovoltaics thermal module were calculated to 121.16 W and 45 cc/min, respec-tively. Though this study, it could be concluded that the photovoltaics thermal system can be composed of up to 53 modules with targeting the Jeju, since the maximum capacity of the coolant circulation pump of the photovoltaics thermal system applied in this study is 2,400 cc/min.

Performance comparison of cascade refrigerator and two-stage compression refrigerator (캐스케이드 냉동시스템과 2단 압축 1단 팽창식 냉동 시스템의 성능 비교)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.625-631
    • /
    • 2014
  • In order to obtain a low evaporation temperature ranging from $-30^{\circ}C{\sim}-50^{\circ}C$, a cascade refrigeration system and two-stage compression one-stage expansion refrigeration system is required. However, the research results of performance comparison of these refrigeration system are very scarce. This paper were compared the performance characteristics of R744-R404A cascade refrigeration system and R404A two-stage compression refrigeration system. The COP of R404A two-stage compression refrigeration system is about 36~57% greater than that of R744-R404A cascade refrigeration system in the range of evaporation temperature of $-30^{\circ}C{\sim}-50^{\circ}C$. But R404A two-stage compression refrigeration system is unstable because COP is significantly changed when evaporating temperature and compressor efficiency decreased. In particular, when compressor efficiency decreased, COP is significantly decreased. In this case, not efficient for long-term use. Whereas R744-R404A cascade refrigeration system using natural refrigerants. Therefore, it is environmentally friendly. And this system is high-efficiency refrigeration system. The reason it can be configured by selecting the suitable refrigerant at high-temperature side and low-temperature side. From the above results, select the appropriate low temperature refrigeration system by considering the environmental and performance aspects.

Importance-Performance Analysis of Operation of Specialized Complexes for Horticultural Production (원예전문생산단지 운영에 대한 중요도-만족도 분석)

  • Hong, Na-Kyoung;Rhee, Zae-Woong;Kim, Tae-Kyun
    • Current Research on Agriculture and Life Sciences
    • /
    • v.33 no.1
    • /
    • pp.25-31
    • /
    • 2015
  • This study investigated the operation criteria of specialized complexes for horticultural production reflecting the farmers' preferences. First, the analysis of the communal activity included six factors: the group purchase of consumables for common activity, group purchase of the greenhouse apparatus, cooperative seed raising, use of a common air conditioning and heating system, cooperative shipping, and soil examination and certification system. The results of the Importance-Performance analysis can be summarized as follows. The factors requiring good management included the group purchase of consumables for common activity, group purchase of the greenhouse apparatus, and cooperative shipping. The factors with a lower priority included cooperative seed raising and the use of a common air conditioning and heating system. While the importance of the soil examination and certification system was low, the satisfaction was high, so this factor needs to be managed to avoid overkill. Second, the analysis of information exchange and education included six factors: production technique information, greenhouse facility management information, distribution-related information, production technique education, greenhouse facility management education, and distribution-related education. The results of the Importance-Performance analysis can be summarized as follows. The factor of production technique education was the most important determinant, plus the factors requiring good management included production technique information, greenhouse facility management information, and distribution-related information. The factors with a lower priority included greenhouse facility management education and distribution-related education. Therefore, to enhance productivity through facility modernization, the scaling up and creation of more specialized horticulture complexes are recommended as policy measures to gain export competitiveness. As the Korean government is expected to expand the scale of specialized horticulture complexes, the results of this paper can be widely utilized.

A Research to Decrease Airborne Microoganism the Train (전동차내 부유 미생물 저감방안에 관한 연구)

  • Choi, Sung-Ho;Choi, Soon-Gi;Son, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2895-2901
    • /
    • 2011
  • SeoulMetro(line number 1 to 4) for the first half of the year. Therefore air quality in the subway is very important. It is passengers, such as sneezing and respiratory vital activities, Suspended due to skin keratin microbial action, and Microbial contaminants such as viruses. Hypersensitivity disorders, an atopic dermatitis, infectious diseases, allergic diseases, and can cause respiratory diseases. Ministry of Environment and National Institute of Environmental Research is managed so the life bacteria. It is emerging as the occupational health problems. Introduction of an appropriate ventilation system for cooling and dehumidification is needed. In line number 2, commuting and normal trains are measured in-room floating microbes. Suspended bacteria and fungi suspended in 2011 for 85 ~ 385$cfu/m^3$, 67 ~ 98$cfu/m^3$ is lower than baseline. Suspended to prevent microbial contamination and air conditioning equipment performance is a substantial improvement. Suspended micro-organisms and the impact on passenger room ventilation is increased. Electric car how to improve air quality substantially investigated.

  • PDF