• 제목/요약/키워드: Air-conditioning System

검색결과 3,317건 처리시간 0.029초

냉수 대온도차 흡수식 냉동기용 2단 증발기/ 흡수기 최적 설계 (Optimum design of the Characteristics of Double Stage Evaporator/Absorber for Large temperature Difference Absorption System)

  • 박찬우;임익태;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.203-211
    • /
    • 2008
  • The optimal design of two stage evaporation & absorption system which is related to the large temperature difference system was investigated numerically in the absorption refrigeration system. The concentrations at inlet & oulet of absorber are 62.9% and 56.9%, but in two stage absorption system the values are 62.2% and 56.2%. Therefore strong solution & weak solution became diluted than the standard value. The amount of weak solution circulation can be reduced in absorption refrigeration system, and the sensible heat load is more reduced to enhance the COP of system. As UAR is increased, COP becomes larger, and this means the role of top section is more important than bottom section in two stage evaporation & absorption system. But the increase of COP becomes slower at 0.7 of UAR ratio. The performance of Type2 is higher than Type1 in COP with the flow direction of cooling waters. This phenomena is due to the active absorption of vapor -absorption & lower temp. cooling water is more effective. The pressure at bottom section becomes higher & that at top section becomes lower and therefore the circulation rate can be diminished more.

  • PDF

제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템 구축 및 냉방성능 평가 (Construction of the Heat Pump System Using Thermal Effluents for Greenhouse Facilities in Jeju and Evaluation of Cooling Performance)

  • 이연건;허재혁;이동원;현명택
    • 에너지공학
    • /
    • 제27권4호
    • /
    • pp.70-79
    • /
    • 2018
  • 한국중부발전 제주화력본부에서 방류되는 온배수로부터 열원을 회수하여 약 3 km의 원거리에 위치하고 있는 신촌백합영농조합법인의 시설온실에 냉온수를 공급하기 위한 300 RT 용량의 열펌프 시스템을 구축하였다. 원거리 시설로 온배수열을 공급하기 위한 최적화 방안을 도출하였고, 수송관로의 온도와 누수여부를 모니터링하기 위한 설비들이 설치되었다. 본 논문에서는 제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템의 구성과 주요기기에 대해 기술하였다. 2018년 하절기에 열펌프 시스템의 냉방성능을 평가하기 위한 실증운전을 수행하였다. 냉방운전 시 열펌프 시스템의 주요 위치에서 측정된 유체의 온도와 유량, 그리고 냉방 성능계수를 분석하여, 구축된 열펌프 시스템의 안정성과 냉방성능을 검증하였다.

u-City응용에서의 시간 패턴을 이용한 단기 전력 부하 예측 (Short-term Power Load Forecasting using Time Pattern for u-City Application)

  • 박성승;손호선;이동규;지은미;김희석;류근호
    • 한국공간정보시스템학회 논문지
    • /
    • 제11권2호
    • /
    • pp.177-181
    • /
    • 2009
  • u-City 활용을 위한 u-공공시설의 개발은 첨단 건축기술과 유비쿼터스 컴퓨팅의 통합으로 새로운 형식의 공간계획과 공공시설물을 내외부에 설치하기 위해 건물의 기반 서비스 시설인 냉난방, 공조, 조명 그리고 전력 관련 시설들의 기반이 구축되어야 한다. 따라서 이 논문에서는 이러한 기반 서비스를 위한 가장 기본적인 것 중 하나인 단기 전력 시스템의 수요와 공급 문제를 해결하기 위하여 시계열 분석을 적용한 시간 패턴 분석을 통해 전력 수요 예측 기술을 제안한다. 시간 패턴 분석을 위해 SOM 알고리즘과 k-means 기법을 적용하여 요일별, 시간별 데이터를 군집화하고 그 자료를 이용하여 시간 패턴 분석 방법인 지수평활기법과 ARIMA 모형을 비교 분석하였다. 제안 시스템 성능 평가 결과 지수평활기법 보다 ARIMA 모형을 적용한 시스템이 더 좋은 결과를 보였다. 따라서, 이러한 전력 부하 예측 결과를 이용하여 전력 공급의 수요에 따른 계획이나 시스템 운영을 효과적으로 할 수 있다.

  • PDF

실내 위치기반 서비스 구현을 위한 센서 시스템 개발 (Development of Sensor System for Indoor Location-Based Service Implementation)

  • 차주헌;이경호
    • 대한기계학회논문집A
    • /
    • 제36권11호
    • /
    • pp.1433-1439
    • /
    • 2012
  • 본 논문에서는 Building Energy Management System(BEMS) 구현을 위해 "재실자의 위치 및 인원정보" 에 기반을 둔 실내 위치 기반 서비스 및 그를 위한 센서 시스템에 대하여 제안한다. 본 논문에서 제안한 센서 시스템에는 열에너지 그 자체를 감지 할 수 있는 서모파일 센서와 비 접촉 방식으로 대상까지의 거리를 얻어낼 수 있는 초음파센서, 그리고 이를 제어하고 구동할 수 있는 기구 및 동작부가 포함된다. 본 시스템은 적절한 크기의 방 전체를 감시할 수 있도록, $360^{\circ}$ 회전과 틸팅이 가능한 구조로 되어있어, 실내공간내의 재실자의 인원 및 위치를 동시에 파악할 수 있다. 또한 무선통신 기술인 블루투스 모듈을 통해 빌딩 관리자나 스마트 홈 서버와의 통신이 가능하도록 되어 있어, 빌딩내의 조명이나 공조시스템을 자동으로 제어, 관리하게 함으로써 전체 에너지 절약을 가능케 한다. 마지막으로 측정 데이터 검증을 위한 실환경 실험을 통해, 본 연구에서 제안한 시스템의 효용성 및 타당성을 확인한다.

R718-R744용 캐스케이드 냉동시스템의 최대 성능 예측 (Prediction on Maximum Performance of Cascade Refrigeration System Using R717 and R744)

  • 노건상;손창효
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2565-2571
    • /
    • 2009
  • 본 논문은 시스템의 운전조건하에서 R717-R747용 이원냉동 사이클의 성능 분석에 대한 기초 설계자료를 제공하는 것이다. 본 논문에서 고려한 운전변수는 암모니아 고온사이클과 이산화탄소 저온사이클의 과냉각도, 과열도, 응축과 증발온도이다. 이원 냉동사이클의 성적계수는 과열도가 증가할수록 증가하는 반면, 과냉각도가 증가할수록 감소한다. 그리고, 이원 냉동사이클의 성적계수는 응축온도와 함께 증가하지만, 증발온도와는 반대로 감소한다. 따라서, 과열도, 과냉도, 응축과 증발온도는 본 시스템의 성적계수에 영향을 미치는 것을 알 수 있었고, 최대 성능계수와 최적의 증발온도에 대한 수학 방정식을 개발하기 위해 이러한 변수들을 포함시켜 다중 회귀분석을 통해 제안하였다.

냉매 과냉각을 이용한 열펌프 시스템의 성능 특성 (The Performance Characteristics of Heat Pump Using the Refrigerant Subcooling)

  • 노건상;손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.413-421
    • /
    • 2007
  • In this paper, the performance characteristics of heat pump system using a new refrigerant subcooling system designed for the study, are introduced. The new heat pump system have the ice storage tank at the outlet of condenser. The experimental apparatus is a well-instrumented water/water heat pump which consisted of working fluid loop, coolant loop, and ice storage tank. The experiment parameters of subcooling ranged as the evaporating temperature from $-5^{\circ}C$ to $8^{\circ}C$, the condensing temperature from $30^{\circ}C$ to $35^{\circ}C$. The test of the ice storage was carried out at evaporating temperature of $-10^{\circ}C$ and the ice storage mode is Ice-On-Coil type. The working fluid was R-22 and the storage materials were city-water. The test results obtained were as follows; The refrigerant mass flow rate and compressor shaft power were unchanged by the degrees of subcooling, that is, they were independent of degrees of subcooling. The cooling capacity of the new heat pump system increase as the evaporating temperature and subcooling degrees increase and is higher by $25{\sim}30%$, compared to the normal heat pump system. The COP of the new heat pump system increases as the degrees of subcooling and evaporating temperature increase and is higher by 28% than that of the normal heat pump system.

해수열원을 이용한 빙상경기장의 에너지절약 방안에 관한 연구 (Energy Saving Strategies for Ice Rink using Sea-Water Heat Source Cooling System)

  • 김삼열;박진영;박재홍
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.53-59
    • /
    • 2014
  • Ice Rink is energy intensive building type. Concern of energy saving from buildings is one of very important issues nowadays. New and renewable energy sources for buildings are especially important when we concern about energy supply for buildings. Among new and renewable energy sources, use of seawater for heating and cooling is an emerging issue for energy conscious building design. The options of energy use from sea water heat sources are using deep sea water for direct cooling with heat exchange facilities, and using surface layer water with heat pump systems. In this study, energy consumptions for an Ice Rink building are analyzed according to the heat sources of air-conditioning systems; existing system and sea water heat source system, in a coastal city, Kangnung. The location of the city Kangnung is good for using both deep sea water which is constant temperature throughout the year less than $2^{\circ}C$, and surface layer water which should be accompanied with heat pump systems. The result shows that using sea water from 200m and 30m under sea lever can save annual energy consumption about 33% of original system and about 10% of that using seawater from 0m depth. Annual energy consumption is similar between the systems with seawater from 200m and 30m. Although the amount of energy saving in summer of the system with 200m depth is higher than that with 30m depth, the requirement of energy in winter of the system with 200m depth is bigger than that with 30m depth.

KSTAR 헬륨냉동기의 압축시스템 시운전 결과 (Commissioning Results of the Warm Compression System for the KSTAR Helium Refrigeration System)

  • 박동성;장현식;주재준;문경모;조광운;김양수;박주식;권일근;조면철;양승한
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.125-130
    • /
    • 2008
  • The main components of the KSTAR helium refrigeration system (HRS) can be classified into the warm compression system (WCS) and the cryogenic devices according to the operating temperature levels. The WCS itself consists of the compressor station (C/S) and the oil removal system (ORS). The process helium is compressed from 1 bar to 22 bar maximum in the C/S and downstream, the ORS removes the oil mixed in the helium to less than 10 ppbw as per the operation criteria of the cryogenic devices of the KSTAR HRS. After the installation, the pre-commissioning and commissioning activities were started on July, 2007. Before the start-up of the C/S, vibration measurement and the skid reinforcement jobs were performed for stable operation of the C/S. The results of the WCS performance tests met the requirements of the KSTAR HRS but satisfied the vibration level criteria only at the compressors' full load condition.

  • PDF

LNG 벙커링용 이중 단열적용 LNG 저장탱크 열해석 (Thermal Analysis on the LNG Storage Tank of LNG Bunkering System Applied with Double Shield Insulation Method)

  • 정일영;김남국;윤상국
    • 한국가스학회지
    • /
    • 제22권4호
    • /
    • pp.1-6
    • /
    • 2018
  • IMO에서 규정하는 LNG 벙커링 선박용 연료 탱크 중 C형 가압탱크는 내외 2중 용기로 구성된 초저온 탱크에 $10^{-2}$ Torr 진공과 펄라이트 단열재가 충전되는 것이다. 그러나 이 단열방식은 LNG 기화량이 하루당 2.0 % 내외로 증발율이 커서 보다 단열효과가 좋은 탱크가 요구되어 진다. 본 연구에서는 내외탱크 사이에 고진공을 적용하고 외부탱크의 내벽체에 중간 단열로 펄라이트 진공단열을 적용하는 단열 방식을 새로이 고안하여 열해석을 수행하였다. 이의 장점으로는 진공 공간의 감소로 고진공 형성 시간을 크게 감소되고, 진공도 $10^{-4}$ Torr 이하에서 하루당 증발율이 0.16 %에 불과한 매우 효율이 높은 탱크 단열방식이 되었다. 만약 현재의 IMO C형 탱크의 진공펄라이트 단열에서 진공이 파괴되는 경우, C형 탱크는 하루당 4.9 %의 증발이 발생하고 새 고안 탱크는 5.23 %로 거의 동일하게 된다.

해수열원 히트펌프 시스템의 냉난방 운전 특성에 관한 실증 연구 (Experimental Study on the Cooling and Heating Operation Characteristics of a Sea Water Source Heat Pump)

  • 김지영;백영진;나호상;장기창
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.544-549
    • /
    • 2009
  • The purpose of this study is to investigate the field Operation Characteristics of a sea water heat source cascade heat pump system and system applicable to Building. Cascade heat pump system is composed R410A compressor, R134a compressor, EEV, cascade heat exchanger, Plate heat exchanger etc. Building area is $890m^2$ and has five floors above ground. R410A is used for a low-stage working fluid while R134a is for a high-stage. The system could runs at dual mode. One is mode of general R410A refrigeration cycle in summer and the other is cascade cycle. In order to gain a high temperature supply water in winter season, the system is designed to perform a cascade cycle. The filed test results show that the sea water heat source heat pump system exhibits a COP of about 5.5 in cooling mode along with a heating COP of about 4.0 in 1-stage heating mode. Cascade 2-stage heat pump system is enough to supply $60^{\circ}C$ water and heating COP is about 3.0

  • PDF