• 제목/요약/키워드: Air-cleaner

검색결과 193건 처리시간 0.025초

수격파를 이용한 배관 세정기 개발 연구 (A Study on the Development of the Water Hammering Cleaner System for Pipeline)

  • 김홍식;김윤제;박광진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.675-678
    • /
    • 2002
  • In order to develop the water hammering cleaner system for removing scale and slime in inner metal or non-metal piping wall, the flow characteristics are investigated by numerical and experimental methods. The air bubbles in the piping systems as a shock wave are formed and transferred with the water flow in the piping. The governing equations are derived from making using of three-dimensional Wavier-Stokes equations with the standard $k-{\varepsilon}$ turbulence model and SIMPLE algorithm. Pressure distributions in the pipeline are calculated for different air supply pressures. Also, we prepared some experimental results of the pressure differences for various air supply times.

  • PDF

DFDA를 이용한 에어 크리너의 분해성 평가 ( 한일 차량용을 중심으로 ) (Disassembility Assessment of Air-cleaner by DFDA ( For Korea-Japan Passenger-Vehicle ))

  • 김하수;강희용;양성모;진정선
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 추계학술대회논문집 - 한국공작기계학회
    • /
    • pp.428-433
    • /
    • 2000
  • A disassembility assessment has mostly depend on the subjective decision making from the qualitative element. The work of disassembly is already classified with given disassemble points from the symbolic chart method. It is not useful in the practical assessment because it is not specified. The new method of design for disassembility assessment(DFDA) is practical to introduce the fuzzy number as the conversion of quantitative element from qualitative. It is appled to compare the usefulness of air-cleaner in Korea-Japan passenger-vehicle.

  • PDF

Design of a Smart Gas Sensor System for Room Air-Cleaner of Automobile (Thick-Film Metal Oxide Semiconductor Gas Sensor)

  • Kim, Jung-Yoon;Shin, Tae-Zi;Yang, Myung-Kook
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.408-412
    • /
    • 2007
  • It is almost impossible to secure the reproductibility and stability of a commercial Thick-Film Metal Oxide Semiconductor Gas Sensor since it is very difficult to keep the consistency of the manufacturing environment. Thus it is widely known that the general Semiconductor-Oxide Gas Sensors are not appropriate for precise measurement systems. In this paper, the output characteristic analyzer of the various Thick-Film Metal Oxide Semiconductor Gas Sensors that are used to recognize the air quality within an automobile are proposed and examined. The analyzed output characters in a normal air chamber are grouped by sensor ranks and used to fill out the characteristic table of the Thick-Film Metal Oxide Semiconductor Gas Sensors. The characteristic table is used to determine the rank of the sensor that is equipped in the current air cleaner system of an automobile. The proposed air control system can also adapt the on-demand operation that recognizes the history of the passenger's manual-control.

롤필터를 장착한 객차용공기청정장치 개발 (The development of Air-cleaner with Roll Filter inside railroad passenger car)

  • 이영섭;남궁석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1297-1301
    • /
    • 2007
  • The indoor air quality guideline of public transportation means was prepared recently. therefore we consider a countermeasure for the indoor air quality improvement of public transportation means. In this work, air-cleaner with roll filter system which developed alternative of indoor air quality guideline. The develpoed roll filter system is two function. the first function harmoniously circulated to heating and cooling air through HVAC system and secondary function removed PM(particluatie matters) which re-scatting to passenger's movement and suppled from outdoor air. Filter media of roll filter system select optimum electret mesh filter out of many filter media. Selected filter media was performanced tests of pressure drop, collection efficiency and dust holding capacity. Finally developed roll filter system was performanced bench test.

  • PDF

진공청소기 모터 하우징 내부 온도상승 개선을 위한 연구 (A Study for the Improvement of Temperature Distribution in the Motor Housing of Vacuum Cleaner)

  • 김주신;김성근;이응호;주보경
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.425-429
    • /
    • 2008
  • The present study has been conducted to improve temperature distribution in the motor housing of vacuum cleaner and reduce the development period by CFD analysis. CFD analysis is performed to investigate the thermal flow pattern in the motor housing and validated by experiments. The validation of CFD analysis is conducted by comparing the temperature distribution on motor housing cover. Through the present study the CFD analysis procedure in the motor housing of vacuum cleaner is established and various experimental materials are obtained. These analysis results can be used effectively as design factors of vacuum cleaner.

  • PDF

차량용 에어클리너의 미세입자 제거특성 (Fine Particle Removal by a Vehicle Air Cleaner)

  • 박병현;김상범;김경수;이상열;이명화
    • 한국분무공학회지
    • /
    • 제12권2호
    • /
    • pp.86-93
    • /
    • 2007
  • There is a growing interest to develop an eco-friendly air cleaner with high performance through a remanufacturing process. Two kinds of polyurethane filter media, a coarse (Filter-A) and a fine filter media (Filer-B), are used in this study to protect a vehicle engine from airborne particles. In order to improve the collection performance of the filters (Filter-A, Filter-B), an oil coating technology on the filter surface was introduced. As a result, inertial force is a dominant collection mechanism for a dry filter media, so that collection efficiency increases with increasing filtration velocity. However, intra-structure change of an oil-coated filter media influences on the collection mechanism, which shows a non-linear collection efficiency curve in terms of filtration velocity. The result shows that the developed filter media are eco-friendly and effective to protect a vehicle engine from airborne particles especially at low filtration velocity.

  • PDF

대형버스 흡기시스템 성능 개선에 관한 연구 (A Study on the Performance Improvement in the Intake System of a Large-sized Commercial Bus)

  • 류명석
    • 한국자동차공학회논문집
    • /
    • 제13권2호
    • /
    • pp.16-21
    • /
    • 2005
  • The performance of reciprocating internal combustion engine is a strong function of the air intake system configuration. In order to improve engine power, it is essential to optimize the air induction system. In this study, a numerical investigation has been carried out for the three-dimensional flow and pressure characteristics in air intake system of a large-sized commercial bus. CFD simulations using STAR-CD were also perform ed to evaluate effects of intake duct geometry and structure variation inside air cleaner on the negative pressure distribution of overall intake system. Studies for improving the back pressure distribution have been proposed and quantitatively examined based on intensive case studies.

진공청소기용 원심팬 주위의 유동해석을 통한 성능개선 (THE PERFORMANCE IMPROVEMENT OF VACUUM CLEANER BY ANALYSIS OF THE FLOW AROUND CENTRIFUGAL FAN)

  • 박진우;기민철;박형구
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 추계 학술대회논문집
    • /
    • pp.82-87
    • /
    • 2007
  • A cleaner has trouble with too much noise and power consumption. To solve these problems, the investigation for motors, which are the main component of vacuum cleaner, is required. However, it is difficult to analyze the flow by the experimental means because of the high speed of the fan rotation ranging from 30,000 rpm to 50,000 rpm. Moreover it takes much time to perform the numerical simulation for the flow. In this research, it is aimed to analyse the flow through the centrifugal fan which is believed to be a main noise source, by the computational method. The efficiency of the centrifugal fan is affected by friction loss, shock loss and so on. Those losses depend on factors like the velocity of impeller, blade shape and etc. Accordingly, the influence of the shape of impeller on the flow is investigated in this study. The computational analysis was done by changing impeller shapes. The flow around the centrifugal fan is simulated by applying the moving mesh. To verify the validity of the computation results, the air flow rate and the pressure field to the cleaner is compared with the experimental data. All simulations are performed by using commercial code SC/Tetra. The calculated results show good agreement with the experimental ones qualitatively and it is believed to be promising to use computational simulation in the improvement of the vacuum cleaner performance.

  • PDF

Mold Occurring on the Air Cleaner High-Efficiency Particulate Air Filters Used in the Houses of Child Patients with Atopic Dermatitis

  • Kim, Seong Hwan;Ahn, Geum Ran;Son, Seung Yeol;Bae, Gwi-Nam;Yun, Yeo Hong
    • Mycobiology
    • /
    • 제42권3호
    • /
    • pp.286-290
    • /
    • 2014
  • Fungi are the known sources of irritation associated with atopic diseases (e.g., asthma, allergic rhinoconjunctivitis, and atopic eczema). To quantitatively estimate their presence in the indoor environment of atopic dermatitis-inflicted child patient's houses (ADCPHs), the high-efficiency particulate air (HEPA) filters installed inside the air cleaners of three different ADCPHs were investigated for the presence of mold. The air cleaner HEPA filters obtained from the three different ADCPHs were coded as HEPA-A, -B, and -C, respectively, and tested for the presence of mold. The colony forming units (CFUs) corresponding to the HEPA-A, -B, and -C filters were estimated to be $6.51{\times}10^2{\pm}1.50{\times}10^2CFU/cm^2$, $8.72{\times}10^2{\pm}1.69{\times}10^2CFU/cm^2$, and $9.71{\times}10^2{\pm}1.35{\times}10^2CFU/cm^2$, respectively. Aspergillus, Penicillium, Alternaria, Cladosporium, Trichoderma, and other fungal groups were detected in the 2,494 isolates. The distribution of these fungal groups differed among the three filters. Cladosporium was the major fungal group in filters HEPA-A and -C, whereas Penicillium was the major fungal group in the filter HEPA-B. Nine fungal species, including some of the known allergenic species, were identified in these isolates. Cladosporium cladosporioides was the most common mold among all the three filters. This is the first report on the presence of fungi in the air cleaner HEPA filters from ADCPHs in Korea.