• Title/Summary/Keyword: Air-Coupled Sensors

Search Result 11, Processing Time 0.024 seconds

Nondestructive Contactless Sensing of Concrete Structures using Air-coupled Sensors

  • Shin, Sung-Woo;Hall, Kerry S.;Popovics, John S.
    • International Journal of Safety
    • /
    • v.7 no.2
    • /
    • pp.17-22
    • /
    • 2008
  • Recent developments in contactless, air-coupled sensing of seismic and ultrasonic waves in concrete structures are presented. Contactless sensing allows for rapid, efficient and consistent data collection over a large volume of material. Two inspection applications are discussed: air-coupled impact-echo scanning of concrete structures using seismically generated waves, and air-coupled imaging of internal damages in concrete using ultrasonic tomography. The first application aims to locate and characterize shallow delamination defects within concrete bridge decks. Impact-echo method is applied to scan defected concrete slabs using air coupled sensors. Next, efforts to apply air-coupled ultrasonic tomography to concrete damage imaging are discussed. Preliminary results are presented for air-coupled ultrasonic tomography applied to solid elements to locate internal defects. The results demonstrate that, with continued development, air-coupled ultrasonic tomography may provide improved evaluation of unseen material defects within structures.

Detection of Damages in Concrete Structures Using Non-Contact Air-Coupled Sensing Methods

  • Shin, Sung-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.3
    • /
    • pp.282-289
    • /
    • 2010
  • Most nondestructive testing techniques require good contact between the sensor and tested concrete surface to obtain reliable data. But the surface preparation is often very time and labor consuming due to the rough surface or limited access of concrete structures. One approach to speed up the data collection process is to eliminate the need for physical contact between the sensor and tested structure. Non-contact air-coupled sensing technique can be a good solution to this problem. An obvious advantage of the non-contact air-coupled sensing technique is which can greatly speed up the data collection in field and thus the damage detection process can be completed very rapidly. In this article, recent developments in non-contact air-coupled sensing technique for rapid detection of damages in concrete structures are summarized to evoke interest, discussion and further developments on this technique to a NDT research community in Korea. It is worth noting that the works in this article have been published in the types of thesis, proceedings, and journals. All published sources are cited in the text and listed in reference.

Acoustic field simulation of a PZT4 disc projector using a coupled FE-BE method

  • Jarng, S.S.
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.211-218
    • /
    • 1999
  • This paper describes the application of a coupled finite element-boundary element method (FE-BEM) to obtain the steady-state response of a piezoelectric transducer. The particular structure considered is a PZT4 disc-typed projector. The projector is three-dimensionally simulated to transduce applied electric charge on axial surfaces of the piezoelectric disc to acoustic pressure in air or in water. The directivity pattern of the acoustic field formed from the projected sound pressure is also simulated. And the displacement of the disc caused by the externally applied electric charge is shown in temporal motion. The coupled FE-BE method is described in detail.

  • PDF

Using Air-coupled Sensors (ASC) for Non-contact Non-destructive Evaluation of Concrete in Structures (Air-coupled 센서를 이용한 비접촉 콘크리트 비파괴 검사법)

  • Kee, Seong Hoon
    • Magazine of the Korea Institute for Structural Maintenance and Inspection
    • /
    • v.17 no.1
    • /
    • pp.48-59
    • /
    • 2013
  • 응력파의 기반한 비파괴 검사법은 비교적 실험 절차 및 실험에 필요한 장비가 단순하고, 인체에 해가 없으며, 비용이 저렴한 특성을 갖고있다. 따라서 건축/토목 구조물의 비파괴 검사에 매우 효과적인 방법으로 알려져 있다. 하지만 기존의 가속도계, 변위계, 지오폰과 같은 부착 센서를 사용할 경우 표면 처리, 센서의 부착 및 이동에 따른 추가적인 시간이 소요되고, 센서와 구조물의 불완전한 커플링으로 인한 측정 결과의 신뢰성 및 일관성을 유지하지 어렵다는 문제를 발생시킨다. 최근 이러한 문제의 해결책으로 Air-coupled sensor (ACS)의 사용이 각광받고 있으며, 여러 연구자들에 의해 ACS의 가능성 및 실용성이 증명되고 있다. 기존의 접촉센서와 비교하여 ACS를 사용했을 때 얻을 수 있는 가장 큰 장점은 센서의 커플링 문제를 근본적으로 해결하여 신뢰도가 높고 일관적인 측정이 가능하고, 대형 건축/토목 구조물의 표면을 음향스캔하여 결과를 신속하게 처리하여 실시간으로 시각화 할 수 있다는 점이다. 이론적으로 ACS를 이용하여 측정하는 물리값은 콘크리트 내부에서 발생된 응력파의 일부가 공기중으로 전파된 누설파 (Leaky wave)이다. 콘크리트 비파괴 검사에 주로 사용하는 100 kHz이하의 저주파를 측정할 경우 일반적으로 콘텐서마이크가 ACS로 사용될 수 있다. 기존 연구자들은 실험 및 이론적 연구를 통하여 응력파에 기반한 비파괴 방법에서 ACS가 기존의 접촉 센서를 대체할 수 있다는 점을 보여주고 있다. 현재 미국에서는 연방 도로청 (FHWA) 및 국가표준기술연구소 (NIST)의 연구비 지원으로 ACS의 실용성을 높이기 위하여 최적화된 음향반사판의 설계를 통한 ACS 의 민감도를 높이기 위한 연구, 다채널 센서 배열 및 데이터 통합을 위한 새로운 알로리즘 개발, 자동화 및 로봇 기술과 융합과 같은 연구가 활발히 진행되고 있다. 멀지 않은 미래에는 ACS를 장착한 무인 로봇이 다양한 종류의 건축/토목 구조물의 건전도를 평가하기 위하여 종횡무진 활약하는 모습을 현실 속에서 볼 수 있을 것이라 기대한다.

  • PDF

Cooling Performance of Geothermal Heat Pump Using Surface Water Heat Exchanger (지표수 열교환기 적용 지열 히트펌프 시스템의 냉방 성능)

  • Lim, Hyo Jae;Kong, Hyoung Jin;Sohn, Byonghu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.316-326
    • /
    • 2017
  • Commercial buildings and institutions are predominantly cooled, thereby dissipating excess heat to a vertical ground heat exchanger (VGHE), than heat extracted over an annual cycle. Surface waters, such as lakes and ponds, provide a cost-effective means of reducing the VGHE length, and in balancing the thermal loads to the ground. This paper presents the measurement and analysis of the cooling performance of ground-coupled heat pump (GCHP) system, using surface water heat exchanger (SWHE) submerged in an artificial pond. In order to measure the performance of the system, we installed monitoring equipment, including sensors, for assessing the temperature and power consumption, after which the operation parameters were determined. The results from the thermal performance test for the SWHE indicate that the temperatures at the outlet of the SWHE and within the pond were affected by outdoor air temperature. In addition, the results reveal similar variation trends on temperatures; however, the peak temperatures of the SWHE were somewhat greater than those of outdoor air, due to the thermal capacity of the pond. Analyzing the cooling performance over the measurement period, the average coefficient of performance (COP) of heat pump was found to be 5.71, while that for the entire system was 2.99.

A Study on the Compressible Fluid Leak Position Detection of Buried Pipelines (매설배관 내의 압축성 유체 누설 위치 검출에 관한 연구)

  • Lee, Jeong-Han;Kim, Hyung-Jin;Yoon, Doo-Byung;Park, Jin-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.40-49
    • /
    • 2016
  • When a leak occurs in the buried pipelines, The leak locations are able to detected by using the vibration sensors. These leak detection system, intended for incompressible fluid, such as water, are of using the wave propagation velocity and a signal arrival time delay between the sensors. In this paper, to develop a leak location detection system for a compressible fluid such as gas, the conventional detection methods have been studied, improved, and verified through the experiment using the compressed air. It confirmed that it is possible to detect the leak location for compressible fluid in the buried pipelines and to be applicable to the development of a leak location detection system in buried pipelines for gas.

Consideration of Sensors for Real-Time Quality Evaluation of Resisitance Spot Welds in Automotive Industry (자동차 저항 점 용접부 실시간 품질 검사 자동화를 위한 센서 검토)

  • Cho, Jung-Ho;Cho, Yong-Joon;Yoo, Sung-Pil;Chang, In-Sung;Do, Sung-Sup
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.50-50
    • /
    • 2010
  • 최근 토요타 자동차의 대량 리콜 사태로 안전과 관련된 자동차 품질에 대한 관심과 중요성이 크게 부각되었다. 본 연구에서는 나날이 높아지고 있는 자동차 품질 기준과 생산 비용 절감, 공정 자동화 요구에 부응하기 위한 차체 저항 점 용접부 품질 검사 자동화 기술 개발을 위해 적용 가능한 센서들을 비교, 검토하였다. 알려진 비파괴 검사 방법은 초음파, 와전류, 방사선 검사법 등 다양한 방법들이 존재하지만, 이 연구에서는 생산 라인 현장 적용이 가능한 소형 센서들을 중심으로 검토 영역을 제한하였다. 검토된 비파괴 검사 방법은 총 5가지 종류로 종래의 수동 초음파 검사법, 집적된 탐촉자를 이용한 3차원 초음파 검사법, NAUT(Non-contact Air-coupled Ultrasonic Test), EMAT(EletroMagnetic Acoustic Test), 그리고 너겟 프로파일러$^{TM}$이다. 이 연구에서는 각 검사법의 원리와 장단점을 설명하고 생산 라인 적용에 필요한 필수 항목들에 대해 고찰하였다.

  • PDF

Snoring Detection using Polyvinylidene Fluoride Vibration Sensors (Polyvinylidene Fluoride 진동센서를 이용한 코골이 검출)

  • Jee, Duk-Keun;Wei, Ran;Kim, Hee-Sun;Im, Jae-Joong
    • Science of Emotion and Sensibility
    • /
    • v.14 no.3
    • /
    • pp.459-466
    • /
    • 2011
  • Sleep diseases such as snoring and sleep apnea are physically, mentally harmful and results serious health problems. Snoring, known as breathing noise, is caused by coupled oscillation of the airway when the air passes through the trachea, and sleep apnea is caused by upper airway blockage. In order to solve these problems, many attempts have been made to detect the snoring during sleep and alleviate it. In this study, a new sensing system and analysis algorithm were developed in order to detect snoring sounds correctly under various sleep environments. Two polyvinylidene fluoride (PVDF) vibration sensors were used inside the pillow. The first PVDF sensor detects vibration transmitted through skull caused by snoring. And the second PVDF sensor detects both snoring sounds and ambient noises. The signals of two sensors were acquired through the designed analog circuits, and analyzed for snoring detection. Ten volunteers were participated for the experiment under five different conditions. Data from two PVDF sensors were processed by the established analysis algorithm, and snoring sounds were compared to noises. The results indicated that the energy of snoring is 70% bigger than that of ambient noise, which proves effectiveness of sensing system and analysis algorithm. Further study would be continued for more wide clinical studies with various environment noises. Based on this study, development of anti-snore pillow and sleep monitoring system for comfort sleep could be developed.

  • PDF

Analysis of Mineral and Volatile Flavor Compounds in Pimpinella brachycarpa N. by ICP-AES and SDE, HS-SPME-GC/MS (ICP-AES와 SDE, HS-SPME-GC/MS를 이용한 참나물의 무기성분과 향기성분)

  • Chang, Kyung-Mi;Chung, Mi-Sook;Kim, Mi-Kyung;Kim, Gun-Hee
    • Journal of the Korean Society of Food Culture
    • /
    • v.22 no.2
    • /
    • pp.246-253
    • /
    • 2007
  • Mineral and volatile flavor compounds of Pimpinella brochycarpa N., a perennial Korean medicinal plant of the Umbelliferae family, were analyzed by inductively coupled plasma-atomic emission spectroscopy (ICP-AES) and simultaneous steam distillation extract (SDE)-gas chromatography mass spectrometry (GC/MS), head space solid phase micro-extraction (HS-SPME)-GC/MS. Mineral contents of the stalks and leaves were compared and the flavor patterns of the fresh and the shady air-dried samples were obtained by the electronic nose (EN) with 6 metal oxide sensors. Principal component analysis (PCA) was carried out using the data obtained from EN. The 1st principal values of the fresh samples have + values and the shady air-dried have - values. The essential oil extracted from the fresh and the shady air-dried by SDE method contain 58 and 31 flavor compounds. When HS-SPME method with CAR/PDMS fiber and PDMS fiber were used, 34 and 21 flavor compounds. The principal volatile components of Pimpinella brachycarpa N. were ${\alpha}$-selinene, germacrene D, and myrcene.

Evaluating the Depth of a Surface-opening Crack in Concrete Slabs using Surface wave Measurements (표면파 측정을 통한 콘크리트 슬래브의 표면균열 깊이 측정)

  • Kee, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.104-112
    • /
    • 2015
  • Non-contact surface wave transmission (SWT) measurements are used to evaluate the depth of a surface-breaking crack in concrete slabs. The author propose a measurement model that includes an appropriate configuration of the source and receivers, and a transmission function for the given configuration. A series of numerical simulations using a 3D finite element model is used to obtain the transmission function. Then, validity of a proposed model is verified through experimental studies. Two air-coupled sensors are used to measured surface waves across surface-breaking cracks with varying depths from 0mm to 100mm with intervals of 10mm in a concrete slab ($1500{\times}1500{\times}180mm^3$) in laboratory. As a result, the proposed method is demonstrated as to be effective for charactering the depth of a surface-breaking crack in concrete bridge deck with an average error of 10%. A discussion on practical applications of the proposed method is also included in this article.