• 제목/요약/키워드: Air volume

검색결과 2,285건 처리시간 0.029초

항공화물 활성화를 위한 정책분석과 지방공항 발전방안 연구: 청주국제공항을 중심으로 (A Study on the Growth of Air Cargo Volume and the Development Plan for Regional Airport Focusing on Cheonng-Ju Int'l Airport)

  • 박원태;성연영;박성식
    • 한국항공운항학회지
    • /
    • 제32권2호
    • /
    • pp.112-123
    • /
    • 2024
  • Responding to rapid changes of global supply chain and fast increasing air cargo volume and demand for e-commerce market, this paper researched the development plans for regional airport specially focused on air cargo logostics through policy research. According to this research, political implications and development plans for Cheong Ju airport (CJJ) to become a part of global supply chain, a regional air cargo hub. Firstly, it is necessary to increase the length of the existing runway from 2,744m to 3,200m or to develop 3rd runway only for a civil aircraft use. Secondly, it is inevitable to develop new air cargo terminal to handle and export such high value-added products as semi-conductor or rechargeable battery through airport. In addition, facing re-shoring trends among global supply chain, CJJ can increase its air cargo volume and also provide feeder service to Incheon airport, inducing global distribution center near airport site.

황색종 연초건조에 있어서 건조조건에 따른 내용성분변화 제3보. 송풍량 변화에 따른 영향 (Studies on the Chemical Components by Curing Condition of Flue- cured Tobacco Leaves III. Effect of Circulating Air Volume during Curing)

  • 석영선;황건중;손현주
    • 한국연초학회지
    • /
    • 제8권2호
    • /
    • pp.19-27
    • /
    • 1986
  • This experiment was carried out to investigate the effect of circulating air volume to chemical composition of tobacco leaves during the bulk curing. The results were as follows : The decrease of circulating air volume prolonged curing time as the case of a 0.058m3/min. kg; but, no remarkable changes with a 0.11m3/min. kg and a 0.083m3/min. kg. When the circulating air volume was decreased, compared with 0.11m3/min. kg, sugar content was increased while total nitrogen and nicotine content showed a reduced values. In case of a 0.058m3/min. kg and a 0.083m3/min.kg, solanone and damascenone were high. Some of volatile neutral constituents and volatile organic acids were increased during curing process ; especially, their quantities were remarkably increased during the midrib drying stage. As circulating air volume decreased the equilibrium moisture content was increased, while leaf shatter index and filling capacity were decreased.

  • PDF

정적연소기에서의 메탄-공기 혼합기의 연소특성(1) : 균질급기 (Combustion Characteristics of Methane-Air Mixture in a Constant Volume Combustion Chamber(1): Homogeneous Charge)

  • 최승환;전충환;장연준
    • 한국자동차공학회논문집
    • /
    • 제11권3호
    • /
    • pp.48-57
    • /
    • 2003
  • A cylindrical constant volume combustion chamber was used to investigate the flow characteristics at spark plug and the combustion characteristics of homogeneous charge methane-air mixture under various initial pressure, excess air ratio and ignition times in quiescent mixture. The flow characteristics such as mean velocity and turbulence intensity was analyzed by hot wire anemometer. Combustion pressure development measured by piezoelectric pressure transducer and flame propagation acquired by ICCD camera were used to investigate the effect of initial pressure, excess air ratio and ignition times on pressure, combustion duration, flame speed and burning velocity. Mean velocity and turbulence intensity had the maximum value at 200 or 300ms and then decreased to near 0 value gradually after 3 seconds. Combustion duration, flame speed and burning velocity were observed to be promoted with excess air ratio of 1.1, lower initial pressure and ignition time of 300ms.

퍼지 알고리즘을 이용한 정풍량 공조기의 고장 감지 및 진단 (Fault Detection and Diagnosis of a Constant Volume Air Handling Unit by a Fuzzy Algorithm)

  • 한도영;김진
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.444-451
    • /
    • 2005
  • The fault detection and diagnosis technology may be applied in order to decrease the energy consumption and the maintenance cost of an air-conditioning system. In this study, partial faults for fans, coils, dampers, and sensors of a constant volume air handling unit were considered. A fuzzy algorithm was developed to detect and diagnose these faults. Diagnostic results by the fuzzy algorithm were compared with those by the model reference algorithm. The fuzzy algorithm showed better results in diagnostic accuracies.

변풍량시스템이 적용된 사무소건물의 환기 및 에너지성능평가 (Ventilation and energy performance evaluation of the office building with variable air volume system)

  • 권용일;권순석
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.100-108
    • /
    • 1999
  • Variable air volume(VAV) system designed for improving interior environmental control has steadily evolved over the last 20 years. Major advantage of VAV system is that VAV technology allows a single system to provide simultaneous heating and cooling without a seasonal changeover. Research is carried out in order to study the influence on the energy consumption and ventilation performance of two kinds of office building with a mixing ventilation system. Data required for performance evaluation in these building is obtained from the central monitoring station and by measurement.

  • PDF

도시공원의 기온에 영향을 미치는 요인 (Factors Affecting Temperature of Urban Parks)

  • 윤용한;송태갑
    • 한국조경학회지
    • /
    • 제28권2호
    • /
    • pp.39-48
    • /
    • 2000
  • The purpose of this study is to investigate the factors affecting temperature of urban parks to grasp the relationship between the land coverage in open space as well as the forest condition and decreasing city temperature by difference of purposed are. Futhermore, this research interpreted the relationship between wind direction, air temperature, the land coverage of the green space, the number of tree, green volume, height of tree and the mitigation of city temperature with the revolution analysis. The result of this study is that cool air in open space move leeward and decreasing city temperature is influenced by the difference of the land coverage in open space. Specifically, in order of the arbo $r_{-a}$rbor in the forest zone, the increase of the number of trees was related with temperature surrounding significantly. This study found that the use possibility of the green volume was recognized as the index of the green volume relative to air temperature surrounding. Green space of the city control area is more effective decreasing temperature than that of housing zone.

  • PDF

Bio-drying 공법 활용 공기 투입 및 예열에 따른 음식물류 폐기물 분해 특성 평가 (Estimation of Characteristics Treatment for Food Waste with Blast Volume and Preheating of Air using Bio-Drying Process)

  • 박세용;이원배
    • 유기물자원화
    • /
    • 제30권4호
    • /
    • pp.15-25
    • /
    • 2022
  • 수본 연구에서는 Bio-drying 공법 활용한 공기 송풍량 및 예열에 따른 음식물류 폐기물의 수분 및 유기물의 처리 효율에 대해 분석하였으며, 음식물류 폐기물 처리 시 온도, CO2의 평가를 통해 공기 송풍량 및 공기 예열이 Bio-drying 공법의 미치는 영향에 대해 평가하였다. 그 결과 공기 송풍량의 증가는 수분 제거율 및 제거 속도가 증가하는 결과를 미쳤지만, Bio-drying 내부 온도를 저하 시켜 미생물 활성도의 감소를 야기시켰다. 미생물의 활성도 유지를 위해서는 음식물류 폐기물의 성상에 따른 적정 공기 송풍량을 주입하는 것이 필요할 것으로 판단되었으며, 본 연구에서는 15L/min으로 주입하였을 때가 최적이었다. 공기 예열 유무에 따른 유기물 및 수분 제거율을 평가한 결과 공기 예열을 하였을 때가 하지 않았을 때에 비해 유기물 제거율 및 수분 제거율이 3~5% 가량 증가하는 결과를 보였다. 또한 Bio-drying 내부에 응축수 발생에 의한 내부 뭉침 현상도 발견되지 않았다. 따라서, 음식물류 폐기물의 효과적인 Bio-drying을 위해서는 미생물 활성도 유지를 위한 적정 송풍량을 유지 해야 하며, 공기 예열을 통한 주입이 필요할 것으로 사료된다.

도시기온에 작용하는 입체적 토지피복의 영향 (Impacts of Three-dimensional Land Cover on Urban Air Temperatures)

  • 조현길;안태원
    • 한국조경학회지
    • /
    • 제37권3호
    • /
    • pp.54-60
    • /
    • 2009
  • 본 연구의 목적은 토지피복의 입체적 분포가 도시기온의 변화에 작용하는 영향을 구명하여 열섬현상 완화에 기여할 도시조경의 전략을 모색하는 것이다. 연구대상지는 서울시 24개 AWS 지점별 직경 300m 공간이었고, 대상공간의 여름철 에너지 수지 및 기온에 영향을 미칠 수 있는 다양한 변수의 자료를 구득하였다. 또한, 춘천시에서 연구목적을 고려한 6개 지점을 선정하여 기온을 실측하고, 기온변화에 더 민감하게 반응할 30m 소공간의 지점별 토지피복을 실사하여 서울시 의 경우와 비교하였다. 서울시 AWS 지점의 여름철 기온을 추정하는 단순회귀모델을 도출한 결과, 식생체적, 녹지면적, 건물체적, 건물면적, 인구밀도, 포장로면적 등의 변수가 통계적으로 유의하게 여름철 기온변화에 기여하는 것으로 나타났다. 이들 중 기온변화의 설명력이 가장 높은 변수는 식생체적과 건물체적이었다. 기온변화에 유의한 변수들을 조합하여 유도한 다중회귀모델에서도 식생체적과 건물체적의 양 변수가 통계적으로 가장 적합한 모델을 생성하였다. 이 다중회귀모델에 따르면 식생체적의 10% 증가는 기온을 약 0.14% 감소시킨 반면, 건물체적의 10% 증가는 기온을 0.26% 증가시켰다. 소공간스케일에서 실측한 춘천시의 여름철 기온과 토지피복 간의 상관성 역시, 기온은 식생체적, 녹지면적 등의 증가에 따라 감소하는 반면 하드스케이프 면적의 증가에 비례하여 상승하는 경향이었다. 식생체적 변수를 적용하여 가장 적합한 단순회귀모델을 도출한 결과, 소공간스케일의 여름철 기온은 서울시 AWS 지점의 단순회귀모델과 유사하게 식생체적을 10% 증가시킴에 따라 0.32%($0.08^{\circ}C$)씩 감소하였다. 본 연구에 근거하면, 여름철 기온저감을 지향하는 도시조경은 식생체적을 증가시키면서 동시에 건물체적을 감소시키는 전략이 요구된다. 서울시 AWS 지점의 기온변화에 기여하는 건물체적의 영향력은 식생체적보다 약 2배 큰 것으로 분석된다. 따라서, 자연지반에서는 다층식재를 추진하여 식생체적을 확충하되, 건물의 입체적 표면에 의한 대기 가열을 제어하기 위해 벽면과 옥상의 녹화로 식물의 차양 및 증발산 효과를 증진해야 한다.

펌프 섬프장 흡입 조건에 따른 자유표면 보텍스 변동에 관한 연구 (A Study on the Change of Free Surface Vortex according to Intake Conditions in the Pump Sump)

  • 박영규;이규명;최윤환;이연원
    • 한국가시화정보학회지
    • /
    • 제9권4호
    • /
    • pp.74-79
    • /
    • 2011
  • In this study the change of free surface vortex is represented at different times according to height of water and with or without curtain wall installation. The air volume fraction is investigated at each condition of water level and the influence about creation of vortex is analyzed. The height of sump intake is taken as 100mm and the water level is divided into 5 steps. The sump model is the TSJ model and the curtain wall is applied by HI standard of America. The results shows that the free surface vortex can be identified on the isotropic surface at air volume fraction 1%~5% and the vortices make an air column from the free surface to the sump intake and are created and destroyed repeatedly. In the higher water level, less air is absorbed into the intake pipe. After curtain wall installation, the suction rate of the air volume fraction is decreased by 6.7%. The result of the vortex motion according to time, works on a cycle.

Convolution-Superposition 알고리즘을 이용한 치료계획시스템에서 공기가 포함된 표적체적에 대한 IMRT 플랜: 전립선 케이스 (Convolution-Superposition Based IMRT Plan Study for the PTV Containing the Air Region: A Prostate Cancer Case)

  • 강세권;윤제웅;박소아;황태진;정광호;한태진;김해영;이미연;김경주;배훈식
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.271-277
    • /
    • 2013
  • 전립선에 대한 IMRT 치료계획을 작성 시 CTV를 확장해서 PTV를 얻을 때 가끔 직장 내의 공기가 포함되는 경우가 있는데, 공기의 처리 여부에 따라 선량 처방에 문제가 발생한다. 이 경우 IMRT 플랜의 최적화 과정에서 다음과 같은 세 가지 가능성을 생각해 볼 수 있다: PTV에 포함된 공기를 원래의 공기밀도로 두는 경우('airOpt'), 포함된 공기의 밀도를 조직과 비슷하게 밀도 1로 하는 경우('density1Opt'), 공기 부분을 제외한 PTV를 고려하는 경우('noAirOpt'). 본 연구에서는 이 세가지 경우에 대해 7개 방향에서 10 MV 광자선으로 동일한 인자의 IMRT 플랜을 하였다. 평가를 위해서는 CTV를 복사한 후, PTV 내에서 직장 쪽으로 이동시켜 최악의 표적 위치 설정이 되도록 원래의 공기가 있는 부분에 위치하도록 해서 가상의 CTV를 만들었다. PTV의 선량커버(dose coverage)와 최대 선량값을 비교했을 때, density1Opt 플랜만이 임상적으로 적절하였다. airOpt 경우, PTV에 과도한 선량이 전달되었고 선량전달체적 또한 과도하였다. noAirOpt 경우에는 이동된 가상 CTV 위치에서 저선량을 보였다. 이 결과에 의하면, 전립선 IMRT 플랜의 작성에서 공기가 포함된 PTV의 경우 플랜의 최적화와 선량 처방을 하기 전에, PTV에 포함된 공기의 밀도를 밀도값 1로 변경하는 것이 적절하였다. 이 아이디어는 두경부 IMRT 플랜을 비롯하여, 표적체적 내에 공기가 포함된 기타 경우에도 그대로 적용가능한 것으로 판단되며, 추가연구를 진행 중이다.