• Title/Summary/Keyword: Air volume

Search Result 2,291, Processing Time 0.032 seconds

Effect of Sludge Characteristics on the Thickening of Bulking Sludge using DAF (Dissolved Air Flotation) (슬러지의 성상이 DAF(Dissolved Air Flotation)를 이용한 팽화 슬러지 농축에 미치는 영향)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.97-103
    • /
    • 2006
  • Excess sludge treatment and disposal currently represent a rising challenge for domestic or wastewater treatment plants due to economic, environmental and regulation factors. Conventional gravity sedimentation process has been widely used in sludge thickening. The operation method of the process is very simple, but the process requires long detention time for sludge thickening, uses polymers, and shows low sludge thickening efficiency. To solve the problems, we studied on DAF (Dissolved Air Flotation) system. We use bulking sludge of a paper manufacturing plant. The effects of parameters such as SVI (Sludge Volume Index), storage time, initial concentration and wet density of excess sludge were examined. The results showed that the more SVI was low, the more sludge was thickened. As storage time goes by, SVI was increased and thickening performance was deteriorated. In order to improve flotation performance at high concentration, high recycling ratio and pressure did not increase the concentration due to thickening limitation. The addition of 0.8 g/L of loess was increased flotation efficiency of 1.41 times.

Exploration of the teaching method for the prescription of the misconceptions on the Candle Experiment (촛불 실험과 관련된 오개념 교정을 위한 지도방안 탐색)

  • 전우수
    • Journal of Korean Elementary Science Education
    • /
    • v.18 no.2
    • /
    • pp.145-151
    • /
    • 1999
  • There is an experiment in the elementary science textbook which a burning candle hold upright in a water tank and a beaker is converted over the burning candle, the candle flame goes out and the water rises into the beaker. Some reference books including teachers' guide for the elementary school teachers explain the reason why water rises that oxygen is "used up", so water rises the same volume of consumed oxygen into the beaker. But this explanation is only partially correct. In this study, discrepancies of the explanation that oxygen is "used up" are analyzed. Water rises by two major reasons. One is that water can rise to the level about l/3 of the volume of consumed oxygen. The other is that the beaker is converted over the burning candle which produces hot CO2 and water vapor, and the candle's flame heats the air around it to expand, after the candle flame goes out, the air in the beaker cools and water vapor changes to liquid water, so, air pressure in the beaker is reduced, and the water is pushed into the beaker by great air pressure outside. 1 demonstrate a inquiry teaching method of the candle experiment.

  • PDF

Numerical study for performance analysis and design of a counterflow type cooling tower (대향류형 냉각탑에 대한 설계 및 성능해석을 위한 수치해석적 연구)

  • 이상윤;이정희;최영기;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.535-549
    • /
    • 1998
  • A numerical study for performance analysis of a counterflow type forced draft tower and natural draft cooling tower has been performed based on the method using the finite volume method with non-orthogonal body fitted and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy balance, moisture fraction balance, water enthalpy balance, and water mass balance equations are solved with Navier-Stoke’s equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study, The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also peformed.

  • PDF

Study on the Counterflow Regenerative Evaporative Cooler with Finned Channels (대향류 핀삽입형 재생증발식 냉방기 연구)

  • Choi, Bong-Su;Hong, Hi-Ki;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.7
    • /
    • pp.447-454
    • /
    • 2008
  • The regenerative evaporative cooler(REC) is to cool a stream of air using evaporative cooling effect without an increase in the humidity ratio. In the regenerative evaporative cooler, the air can be cooled down to a temperature lower than its inlet wet-bulb temperature. Besides the cooling performance, for practical application of the regenerative evaporative cooler, the compactness of the system is also a very important factor to be considered. In this respect, three different configurations, i.e., the flat plate type, the corrugated plate type, and the finned channel type are investigated and compared for the most compact configuration. The optimal structure of each configuration is obtained individually to minimize the volume for a given effectiveness within a limit of the pressure drop. Comparing the three optimal structures, the finned channel type is found to give the most compact structure among the considered configurations. The volume of the regenerative cooler can be reduced to 1/8 by adopting the finned channel type as compared to that of the flat plate type.

Numerical Study for the Performance Analysis and Design of a Crossflow- Type Forced Draft Cooling Tower

  • Choi, Young-Ki;Kim, Byung-Jo;Lee, Sang-Yun;Lee, Jung-Hee
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.1
    • /
    • pp.1-13
    • /
    • 2000
  • A numerical study for performance analysis of a crossflow-type forced draft cooling tower has been performed based on the finite volume method with non-orthogonal body fitted, and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy, moisture fraction, water enthalpy, and water mass balance equations are solved with Navier-Stoke's equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study. The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also performed.

  • PDF

Optimal Allocation of Three Modes for the Intercontinental Transportations of Mass-Market Products

  • Okita, Katsuhisa;Amemiya, Takashi
    • Industrial Engineering and Management Systems
    • /
    • v.9 no.4
    • /
    • pp.294-302
    • /
    • 2010
  • There is a trend toward the world's manufacturing sites moving to East Asia. After manufacture, these products are transported to the advanced nations for their consumption demands. Among such advanced nations, the U.S.A. has the largest demand, and then Japan and European countries follow. It should be noted that the infrastructures of the Asian districts used for the production sites are rather limited, and the volume of products transported from these districts of Asia to the U.S.A is becoming tremendously large. This situation is causing very serious traffic problems. New products are required to be transported swiftly by air. Once the consumption and market demands are stable however, the products should be sent rather slowly, but in larger amounts. However, the airports of China are quite restricted in capacity, while the transportation volume is becoming large. As a result, transportation cost and the time required for transportation are increasing. Now, a third method is appearing. This is the so-called Sea and Air transportation. The cost and time in transit of this mode take mean positions between Air and Ocean services. At present there exists no well-thought-out strategy for how to allocate these three methods of transportation. This paper is an attempt to theoretically describe this mechanism and to discover the optimal way to allocate the three modes. For this purpose, several mathematical properties of value and cost of the products are defined, and on this basis a simulation of the transportation is established.

Improved Air Stability of OTFT's with a P3HT/POSS Active Layer (P3HT/POSS 합성 활성층을 이용한 OTFT 소자의 대기안정성 향상)

  • Park, Jeong-Hwan;Han, Kyo-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.2
    • /
    • pp.107-113
    • /
    • 2009
  • In order to improve air stability, we proposed a new active layer of an organic TFT by synthesizing P3HT/POSS conjugated polymer. P3HT/POSS OTFTs with the various P3HT/POSS volume ratios were fabricated and characterized. With the P3HT/POSS volume ratio of 1:1, we achieved the field-effect mobilities of ${\sim}1.19{\times}10^{-3}\;cm^2/v{\cdot}sec$ in the saturation region and the current on/off ratio of ${\sim}2.51{\times}10^2$. The resulting current on-off ratio was much higher than that of the P3HT-based OTFTs and resulted from the dramatic decrease of the off-current. Since the off-current can be reduced by preventing oxygen in atmosphere from doping the P3HT/POSS active layers, this new active layer shows its ability to avoid oxygen doping in atmosphere. Therefore, the improvement of the air stability can be achieved by employing the P3HT/POSS active layers.

Design of Runner System and Prediction of Moving Distance of the Screw for the Improvement of Formability of a Housing Part of Small-Size Air Cleaner (소형 공기청정기 하우징의 성형성 향상을 위한 런너시스템 설계 및 스크류 전진 거리 예측)

  • Kim, Dong-In;Lee, Ho-Jin;Ahn, Dong-Gyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.12
    • /
    • pp.1021-1030
    • /
    • 2016
  • The runner system of the injection mould and the injection volume of the injection molding process greatly affect the quality of the produced part. The goal of this paper is the design of the runner system and the prediction of the injection volume for the injection moulding of a housing part of small-size air cleaner to improve the formability through the three-dimensional injection moulding analysis. The effects of the runner system of the mould on the injection moulding characteristics are investigated. From the results of the investigation, a proper design of the runner system with uniform filling characteristics and the minimized defect formation is obtained. In addition, the influence of the moving distance of the screw on filling characteristics, weldline formation and deformation characteristics is examined. From the results of the examination, an appropriate moving distance of the screw for the housing part of small-size air cleaner is estimated.

An Experimental Study on the High Performance Optimal Discharge System of a Rotary Compressor for an Air Conditioner using alternative Refrigerant R410a (대체냉매 공기조화기용 로터리 압축기의 성능향상을 위한 최적 토출계에 관한 실험적 연구)

  • Youn, Young;Chung, Jin-Taek;Min, Man-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.96-105
    • /
    • 2001
  • R410a which is one of HFC refrigerants is being considered to be a promising replacement for R22 widely used in domestic air conditioners. The rolling piston type rotary compressors for R410a have lower energy efficiency than those for R22 because of the high pressure difference between a suction chamber and a discharge chamber in the compression mechanism. in addition, the re-expansion gas loss of the rotary compressor for R410a which occurs a ta clearance volume in a discharge port becomes larger than that for R22 due to high density of R410a refrigerant. Therefore, Pressure-Volume analyses for various design parameters of a discharge system were carried out to improve efficiency of a R410a rotary compressor. The results such as performance dta, over-compression loss, and re-expansion loss were acquired by P-V analyses and analyzed quantitatively. As a conclusion, the optimal specifications of several design parameters of a discharge system were obtained by analyzing P-V diagrams.

  • PDF

Assessing Commercial CLEANBOLUS Based on Silicone for Clinical Use

  • Son, Jaeman;Jung, Seongmoon;Park, Jong Min;Choi, Chang Heon;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.159-164
    • /
    • 2021
  • Purpose: We investigated the properties of CLEANBOLUS based on silicone with suitable characteristics for clinical use. Methods: We evaluated the characteristics of CLEANBOLUS and compared the results with the commercial product (Super-Flex bolus). Also, we conducted physical evaluations, including shore hardness, element composition, and elongation break. Transparency was investigated through the measured absorbance within the visible region (400-700 nm). Also, dosimetric characteristics were investigated with surface dose and beam quality. Finally, the volume of unwanted air gap was investigated based on computed tomography images for breast, chin, and nose using Super-Flex bolus and CELANBOLUS. Results: CLEANBOLUS showed excellent physical properties for a low shore hardness (000-35) and elongation break (>1,000%). Additionally, it was shown that CLEANBOLUS is more transparent than Super-Flex bolus. Dosimetric results obtained through measurement and calculation have an electron density similar to water in CLEANBOLUS. Finally, CLEANBOLUS showed that the volume of unwanted air gap between the phantom and each bolus is smaller than Super-Flex bolus for breast, chin, and nose. Conclusions: The physical properties of CLEANBOLUS, including excellent adhesive strength and lower shore hardness, reduce unwanted air gaps and ensure accurate dose distribution. Therefore, it would be an alternative to other boluses, thus improving clinical use efficiency.