• Title/Summary/Keyword: Air shifter

Search Result 9, Processing Time 0.027 seconds

CPW Phase Shifter and Shunt Stub with Air-Bridge Fabricated on Oxidized Porous Silicon(OPS) Substrate (산화된 다공질 실리콘 기판 위에 제작된 에어브리지를 가진 CPW Phase Shifter와 Shunt Stub)

  • Sim, Jun-Hwan;Park, Dong-Kook;Kang, In-Ho;Kwon, Jae-Woo;Park, Jeong-Yong;Lee, Jong-Hyun;Jeon, Joong-Sung;Ye, Byeong-Duck
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.9
    • /
    • pp.11-18
    • /
    • 2002
  • This paper presents a CPW phase shifter and shunt stub with air-bridge on a 10-${\mu}m$-thick oxidized porous silicon(OPS) substrate using surface micromachining. The line dimensions of the CPW phase shifter was designed with S-W-Sg = 100-30-400 ${\mu}m$. And the width and length of the air-bridge with "ㄷ“ shape were 100 ${\mu}m$ and 400-460-400 ${\mu}m$, respectively. In order to achieve low attenuation, stepped air-bridge CPW phase shift was proposed. The insertion loss of the stepped air-bridge CPW phase shift is more improved than that of no stepped air-bridge CPW phase shift. The measured phase characteristic of the fabricated CPW phase shifter is close to 180$^{\circ}$ over a very broad frequency range of 28 GHz. The measured working frequency of short-end series stub is 28.7 GHz and the return loss is - 20 dB. And the measured working frequency of short-end shunt stub is 28.9 GHz and the return loss is - 23 dB at midband. As a result, the pattering of stub in the center conductor of CPW lines can offer size reduction and lead to high density chip layouts.

An Experimental Study on the Operating Performance of an Air Shift type Heat Pump with Heat Exchanger (전열교환기가 설치된 기류전환형 히트펌프의 동계운전성능에 관한 실험적 연구)

  • Jang, Young-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.8
    • /
    • pp.567-572
    • /
    • 2010
  • Air shift type heat pump is combined heat recovery ventilator and refrigerator, and it is installed an air shifter changing air flow. And so it is an perfect AHU(Air Handling Unit) capable to cooling, heating, ventilation and heat recovery. Therefore, an experimental study has been carried out to investigate the operating performance in winter for this system. An experimental data are room temperature, inlet/outlet temperature of condenser, evaporator and heat exchanger. They have been measured as the variation of outdoor temperature. The results, in case of rising above freezing, the air shift type heat pump system is operated normally, and the heating COP is 3.0~4.2 by varying outdoor temperature from $-3^{\circ}C$ to $15^{\circ}C$.

Piezo-controlled Dielectric Phase Shifter

  • Jeong Moon-Gi;Kim Beom-Jin;Kazmirenko Victor;Poplavko Yuriy;Prokopenko Yuriy;Baik Sung-Gi
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2006
  • A sandwich structure of dielectric material and air gap inside a rectangular waveguide is proposed as a fast electrically tunable low-loss phase shifter. As the dielectric material is shifted up and down by piezoelectric actuator and, thereby, the thickness of air gap is changed, the effective dielectric constant of the sandwich structure is varied. Phase shifters based on the sandwich structure with different dielectric materials showed phase shift of $20{\sim}200^{\circ}/cm$ at X-band as the thickness of air gap varied up to $30{\mu}m$. The idea can be extended toward low-loss millimeter wave phase shifters since modem microwave ceramics have been developed to show very low dielectric loss$(tan\;{\delta}{\sim}10^{-4})$.

A 5-17 GHz Wideband Reflection-Type Phase Shifter Using Digitally Operated Capacitive MEMS Switches

  • Kim, Jung-Mu;Lee, Sang-Hyo;Park, Jae-Hyoung;Baek, Chang-Wook;Kwon, Young-Woo;Kim, Yong-Kweon
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2003.12a
    • /
    • pp.117-121
    • /
    • 2003
  • In this paper, a micromachined low-loss and ultra wide band reflection-type phase shifter (RTPS) is proposed. The phase shifter shows a constant phase shift from 5 to 17 GHz and consists of two cascaded reflection-type phase shifter. Low-loss reflection termination consists of digital capacitive switches, and air-gap overlay CPW couplers are used in order to employ the low-loss 3 dB coupling. The fabricated phase shifter showed the 5 discrete states, $0^{\circ},{\;}22.5^{\circ},{\;}45^{\circ},{\;}67.5^{\circ},{\;}90^{\circ}$ respectively, the average insertion loss of 3.48 dB, and maximum rms phase error of ${\pm}1.80^{\circ}$ for the relative phase shift from $0^{\circ}{\;}to{\;}90^{\circ}$ over 5-17 GHz.

  • PDF

Coplanar Waveguides with Air-Bridge Fabricated on Oxidzed Porous Silicon (OPS) Substrate using Surface Micromachining (표면 마이크로머시닝을 이용한 산화된 다공질 실리콘 기판 위에 제조된 에어브리지를 가진 Coplanar Waveguides)

  • Sim, Jun-Hwan;Park, Dong-Kook;Kang, In-Ho;Kwon, Jae-Woo;Lee, Jong-Hyun;Ye, Byeong-Duck
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.2026-2028
    • /
    • 2002
  • 본 논문에서는 실리콘 기판상의 전송선로 특성을 개선하기 위하여 표면 마이크로머시닝 기술을 이용하여 $10{\mu}m$ 두께의 다공질 실리콘 산화막으로 제조된 기판 위에 에어브리지를 가진 CPW 전송선로와 phase shifter를 제작하였다. 간격이 $30{\mu}m$, 신호선이 $80{\mu}m$인 CPW 에어브리지 전송선의 삽입손실은 4 GHz에서 -0.25 dB이며, 반사손실은 -28.9 dB를 나타내었다. CPW phase shifter의 크기는 S-W-$S_g$ = 100-30-400 ${\mu}m$로 설계되었다. "ㄷ" 모양을 가진 에어브리지의 폭은 $100{\mu}m$. 길이는 400-460-400 ${\mu}m$이다. 낮은 손실을 얻기 위한 Step된 에어브리지를 가진 phase shifter 구조가 step이 없는 에어브리지를 가진 구조보다 삽입손실이 보다 더 향상되었다. 제작된 CPW phase shifter의 위상특성은 28 GHz의 넓은 주파수 범위에서 $180^{\circ}E 의 천이를 타나내었다. 이상과 같은 결과로부터 두꺼운 다공질 실리콘은 고 저항 실리콘 집적회로 공정에서 고성능 저가의 마이크로파 및 밀리미터파 회로 응용에 충분히 활용 될 수 있으리라 기대된다.

  • PDF

Investigating the effects of a range shifter on skin dose in proton therapy

  • Ming Wang;Lei Zhang;Jinxing Zheng;Guodong Li;Wei Dai;Lang Dong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.215-221
    • /
    • 2023
  • Proton treatment may deliver a larger dose to a patient's skin than traditional photon therapy, especially when a range shifter (RS) is inserted in the beam path. This study investigated the effects of an RS on skin dose while considering RS with different thicknesses, airgaps and materials. First, the physical model of the scanning nozzle with RS was established in the TOol for PArticle Simulation (TOPAS) code, and the effects of the RS on the skin dose were studied. Second, the variations in the skin dose and isocenter beam size were examined by reducing the air gap. Finally, the effects of different RS materials, such as polymethylmethacrylate (PMMA), Lexan, polyethylene and polystyrene, on the skin dose were analysed. The results demonstrated that the current RS design had a negligible effect on the skin dose, whereas the RS significantly impacted the isocenter beam size. The skin dose was increased considerably when the RS was placed close to the phantom. Moreover, the magnitude of the increase was related to the thickness of the inserted RS. Meanwhile, the results also revealed that the secondary proton primarily contributed to the increased skin dose.

A 94-GHz Phased Array Antenna Using a Log-Periodic Antenna on a GaAs Substrate

  • Uhm, Won-Young;Ryu, Keun-Kwan;Kim, Sung-Chan
    • Journal of information and communication convergence engineering
    • /
    • v.13 no.2
    • /
    • pp.81-85
    • /
    • 2015
  • A 94-GHz phased array antenna using a log-periodic antenna has been developed on a GaAs substrate. The developed phased array antenna comprises four log-periodic antennas, a phase shifter, and a Wilkinson power divider. This antenna was fabricated using the standard microwave monolithic integrated circuit (MMIC) process including an air bridge for unipolar circuit implementations on the same GaAs substrate. The total chip size of the fabricated phased array antenna is 4.8 mm × 4.5 mm. Measurement results showed that the fabricated phased array antenna had a very wide band performance from 80 GHz to 110 GHz with return loss characteristics better than -10 dB. In the center frequency of 94 GHz, the fabricated phased array antenna showed a return loss of -16 dB and a gain of 4.43 dBi. The developed antenna is expected to be widely applied in many applications at W-band frequency.

A study on the characteristics of gas flow in inlet port of 2 cycle engine (2사이클 기관 흡기 포오트의 가스 유동 특성에 관한 연구)

  • 이창식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.5
    • /
    • pp.725-730
    • /
    • 1987
  • An experimental study of the air flow through inlet pipe of reciprocating two-cycle engine was investigated under motored condition. Measurements of the two components of velocity, velocity fluctuation, and the other behavior of inlet flow have been obtained by laser Doppler anemometer system. The research engine comprised the cylinder head of a two-cycle engine which mounted on optical spacer with measuring window and glass inlet entry for laser anemometer measurement. A dual beam laser Doppler anemometer was used with conventional forward scattered method and comprised argon-ion laser, frequency shifter with Bragg cell module, and the signal processor. Measurements of mean velocity fluctuation of inlet flow for different engine speeds, measuring positions, and the changes in cylinder volume are investigated. The results presented show that the changes in engine speed is shown to be strongly influenced on the mean velocity of inlet air. The effect of measuring position and cylinder volume on the inlet velocity was also investigated for the inlet port entry and is shown to be small compared to the engine speed.

Study on Hydrogen Production and CO Oxidation Reaction using Plasma Reforming System with PEMFC (고분자 전해질 연료전지용 플라즈마 개질 시스템에서 수소 생산 및 CO 산화반응에 관한 연구)

  • Hong, Suck Joo;Lim, Mun Sup;Chun, Young Nam
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.656-662
    • /
    • 2007
  • Fuel reformer using plasma and shift reactor for CO oxidation were designed and manufactured as $H_2$ supply device to operate a polymer electrolyte membrane fuel cell (PEMFC). $H_2$ selectivity was increased by non-thermal plasma reformer using GlidArc discharge with Ni catalyst simultaneously. Shift reactor was consisted of steam generator, low temperature shifter, high temperature shifter and preferential oxidation reactor. Parametric screening studies of fuel reformer were conducted, in which there were the variations of the catalyst temperature, gas component ratio, total gas ratio and input power. and parametric screening studies of shift reactor were conducted, in which there were the variations of the air flow rate, stema flow rate and temperature. When the $O_2/C$ ratio was 0.64, total gas flow rate was 14.2 l/min, catalytic reactor temperature was $672^{\circ}C$ and input power 1.1 kJ/L, the production of $H_2$ was maximized 41.1%. And $CH_4$ conversion rate, $H_2$ yield and reformer energy density were 88.7%, 54% and 35.2% respectively. When the $O_2/C$ ratio was 0.3 in the PrOx reactor, steam flow ratio was 2.8 in the HTS, and temperature were 475, 314, 260, $235^{\circ}C$ in the HTS, LTS, PrOx, the conversion of CO was optimized conditions of shift reactor using simulated reformate gas. Preheat time of the reactor using plasma was 30 min, component of reformed gas from shift reactor were $H_2$ 38%, CO<10 ppm, $N_2$ 36%, $CO_2$ 21% and $CH_4$ 4%.