• Title/Summary/Keyword: Air respirator

Search Result 37, Processing Time 0.028 seconds

Knowledge, Attitudes and Perceptions of Nurses on Personal Protective Equipment: Response to the Middle East Respiratory Syndrome Coronavirus (간호사의 개인보호장비에 대한 지식, 태도 및 인식: 메르스 대응을 중심으로)

  • Kim, Kyungnam;Lee, Ogcheol
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.23 no.4
    • /
    • pp.402-410
    • /
    • 2016
  • Purpose: Personal protective equipment (PPE) is critical to protect healthcare workers from pandemic outbreaks. This study was designed to identify nurses' knowledge, attitude and perceptions on PPE. Methods: Data were collected from 154 nurses working at a tertiary general hospital, where positively diagnosed and suspected patients were accepted and admitted during the Middle East Respiratory Syndrome Coronavirus outbreak in 2015. The PPE tool consists of 20 items for knowledge, and 5 each for attitudes and perceptions. Results: Overall, knowledge for PPE was higher than moderate (76.95/100), but there was a lack for items related to powered air purifying respirator (PAPR). For attitudes, willingness to work in pandemic outbreaks was the most positive (4.04/5.00). Goggles and PAPR were perceived as the most uncomfortable barriers to work. There was no correlation between knowledge, attitude and perceptions, despite a strong positive correlation between attitude and perceptions. PPE training was identified as a factor to improve knowledge and attitudes on PPE. Conclusion: To respond to pandemic influenza, nurses need to expand their knowledge on PPE up to Level C, and be updated through regular training. Study findings suggest that repetitive studies targeting nurses and other healthcare workers at various hospital settings are necessary.

Microbial Contamination of Masks Worn by Healthcare Professionals (일부 의료기관 종사자가 사용한 마스크의 미생물 오염 사례)

  • Hyekyung Seo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.395-402
    • /
    • 2023
  • Objectives: Microbial contamination of face masks used by healthcare professionals can vary depending on the degree of exposure to bioaerosols in various healthcare environments. However, research on this topic is limited. Therefore, we analyzed microbial contamination of N95 respirators used in hospital offices, wards, and outpatient settings. Methods: Samples isolated from N95 respirators worn for 2, 4, and 6 hours were incubated at a temperature of 35-37℃ or 25-28℃ for 24 hours or for 3-7 days, and colony-forming units were counted in chocolate agar, tryptic soy agar, and Sabouraud dextrose agar plates. Total indoor airborne bacteria were also measured in the healthcare environments. Finally, microbial species were identified using Gram staining with a microscopic speculum. Results: The three types of environments did not deviate from the maintenance of standard indoor air quality. There was no difference between the microbial species identified in the healthcare environment and mask contamination. However, the number of bacteria in the masks worn in each environment differed, and the degree of contamination increased with mask-wearing time (p<0.05). Conclusions: Therefore, care must be taken to avoid recontamination of masks due to improper use and exposure to biological hazards in healthcare environments. In conclusion, scientific evidence is necessary for safe mask-wearing times. Based on the results of this study, we hope to conduct further research to establish guidelines for the safe use of face masks during respiratory disease epidemics.

A Study on the Distribution of VOC Concentrations by Attachment Position of Air Samplers for Working Environment Measurement (작업환경측정 시료 채취기의 부착 위치에 따른 유기화합물의 농도 분포에 관한 연구)

  • Kwon, Yung-Gyu;Won, Jung Il;Jang, Hyung Seok;Sim, Sang-hyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.328-337
    • /
    • 2015
  • Objectives: The purpose of this study is to investigate differences in concentration according to the position at the left or right shoulder within a 30 cm of radius of workers' respirators and provide basic data for the establishment of an industrial health policy. Methods: Personal samples were collected from a total of 65 workers from 27 manufacturing firms in South Gyeongsang-do Province from November 5, 2011 to December 30, 2012 after classifying the laborers into left- and right-side groups. The organic compound samples were collected and analyzed in accordance with the NIOSH Manual of Analytical Methods (NMAM) 1501. Results: In terms of the concentration of organic compounds collected from both left and right shoulders at the position of workers' respirators, isobutyl acetate was the highest with 145 ppm at the left shoulder, followed by ethyl acetate (133.5 ppm) and toluene (38.13 ppm). At the right shoulder, on the contrary, ethyl acetate (149.3 ppm) was the highest, followed by toluene (46.26 ppm), xylene (29.63ppm) and isopropyl alcohol (28.06 ppm). Overall, the right shoulder was higher than the left shoulder in terms of concentrations. Conclusions: For the measurement of the working environment, workers' personal samples should be collected at the place closest to the respirator. In terms of the reduction of error, the attachment of two sample media is expected to reduce errors in exposure assessment.

Occupational Health Management in the Lead Industry: The Korean Experience

  • Lee, Byung-Kook
    • Safety and Health at Work
    • /
    • v.2 no.2
    • /
    • pp.87-96
    • /
    • 2011
  • In 1967, the problem of occupational lead exposure came to public attention in Korea. Since then, regular progress has been made in lowering workplace lead exposures, instituting new workplace controls, and implementing health examinations of exposed workers. Past serious lead poisoning episodes made it possible to introduce biological monitoring programs on a voluntary basis in high-lead-exposure facilities in Korea. Industry-specific occupational health services for lead workers in Korea during the last 22 years can be categorized into three phases. During the first phase (1988-1993), efforts were directed at increasing awareness among workers about the hazards of lead exposure, biological monitoring of blood zinc protoporphyrin began, and a respiratory protection program was introduced. During the second phase (1994-1997), a computerized health management system for lead workers was developed, blood-lead measurement was added to biologic monitoring, and engineering controls were introduced in the workplace to lower air-lead levels to comply with air-lead regulations. Finally, during the third phase (1998-present), a new biomarker, bone-lead measurement by X-ray fluorescence, was introduced. Bone-lead measurement proved to be useful for assessing body burden and to demonstrate past lead exposure in retired workers. Occupational health service practice for lead workers, including the industry-specific group occupational health system, has brought considerable success in the prevention of lead poisoning and in reducing the lead burden in Korean lead workers during the last several decades. The successful achievement of prevention of lead poisoning in Korea was a result of the combined efforts of lead workers, employers, relevant government agencies, and academic institutes.

Mobility and Thermal Comfort Assessment of Personal Protective Equipment for Female Healthcare Workers: Impact of Protective Levels and Body Mass Index (감염병 대응 개인보호복의 동작성 및 열적 쾌적성: 보호 수준 및 여성 착용자 체격의 영향)

  • Do-Hee Kim;Youngmin Jun;Ho-Joon Lee;Gyeongri Kang;Cho-Eun Lee;Joo-Young Lee
    • Fashion & Textile Research Journal
    • /
    • v.26 no.1
    • /
    • pp.123-136
    • /
    • 2024
  • This study aimed to assess the mobility and thermal comfort of personal protective equipment (PPE) among female healthcare workers, taking into account wearers' physique and PPE protection levels. A total of 16 participants (age: 26.3 ± 8.3 y, height: 161.5 ± 7.3 cm, body weight: 57.1 ± 11.0 kg, BMI: 21.9 ± 3.6), representing diverse body types, underwent four PPE conditions: L (Low_Plastic gown ensemble), M (Medium_Tyvek 400), H (High_Tyvek 800J with Powered Air Purifying Respirator [PAPR]), and E (Extremely high_Tychem 2000 with PAPR, Bib apron, and Chemical-resistant gloves). The mobility protocol consisted of 10 different tasks in addition to donning and doffing. The 10 tasks were repeated twice at an air temperature of 24.3 ± 0.1℃, 59±4%RH. Findings revealed a disproportionate relationship between PPE protection and wearer discomfort. Significant differences in clothing microclimate and total sweat rate were observed between the lowest (L) and highest (E) protection levels (p < 0.01), while distinctions among medium levels were inconclusive. Subjective evaluations favored conditions H and L over M and E (p < 0.05), indicating reduced heat, and humidity, increased comfort, and lower exertion. Instances of mobility discomfort, specially in the small body type group, underscored the need for a suitable PPE size system for Korean adult female medical workers. Furthermore, enhancements in gloves, shoe cover, and PAPR hood designs are essential for improving ease of movement and preventing hindrance.

A Study on Measures to Achieve Performance and Safety of Air Respirators for Fire Fighters (소방대원용 공기호흡기의 성능안전확보 대책에 관한 연구)

  • Son, Bong-Sei;Oh, Suk-Hwan;Kim, Yeop-Rae
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.77-81
    • /
    • 2012
  • This study of aims to provide basic data for improve the performance of air respirators that generate by bad influencing elements in fire emergency field. With three types of conditions set up for these tests, the pressures of containers have been extracted; the ambient temperatures have been checked, and the generation of moisture inside and outside container have been checked and identified. Specifically, these tests have been conducted at temperatures ranging between $-20{\sim}40^{\circ}C$. The pressures of containers have been extracted to reach between 0.4~0.8 MPa, using a pressure regulating valve. These tests have resulted in no change in the temperature and moisture outside the containers and no generation of moisture inside the containers as well. Although moisture has been generated inside the pressure gauge, the amount of moisture has not exceeded 25 $mg/m^3$, i.e. the limit suggested by the Korean Government. Therefore, it is judged that the moisture generated inside air respirators, which can be the most critical issue in the equipment, is likely to be caused in the process of managing the equipment or replacing air in the equipment at places of end-users, rather than in the process of manufacturing and production of the equipment.

Assessment of correlation between markers of ambient monitoring and biological monitoring of dimethylformamide for workers in synthetic leather manufacturing factories in Korea (국내 합성피혁제조업 근로자에 대한 디메틸포름아미드의 공기중 농도와 생물학적 노출지표간의 상관성 평가)

  • Hwang, Yang In;Lee, Mi-Young;Chung, Yun Kyung;Kim, Eun A
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.315-325
    • /
    • 2013
  • The possibility of acute hepatotoxicity caused by dimethylformamide (DMF) requires regular monitoring of the workers who are using DMF to prevent the occupational disease. The authors performed ambient and biological monitoring of workers involved in synthetic leather manufacturing processes using DMF to assess the correlation between the markers of ambient and biological monitoring of DMF. The authors monitored 142 workers occupationally exposed to DMF from 19 workshops in the synthetic leather and ink manufacturing industries located in northern region of Gyeonggi-do. The subjects answered questionnaire on work procedure and use of personal protective equipment to be classified by exposure type. DMF in air samples collected using personal air samplers, diffusive and active sampler, was analysed using gas chromatograph-flame ionization detector (GC-FID) with DB-FFAP column (length 30 m, i.d. 0.25 mm, film thickness 0.25 ${\mu}m$). Urinary N-methylformamide (NMF) was analysed using gas chromatograph-mass selective detector (GC-MSD) at selected ion monitoring (SIM) mode with DB-624 column (length 60 m, i.d. 0.25 mm, film thickness 1.40 ${\mu}m$). Geometric mean (GM) and geometric standard deviation (GSD) of the ambient DMF was $6.85{\pm}3.43$ ppm, and GM and GSD of urinary NMF was $42.3{\pm}2.7$ mg/L. The ratio of subjects with DMF level over 10 ppm was 44%, and those with urinary NMF over 15 mg/L was 87%. NMF in urine adjusted by DMF in air was $4.61{\pm}2.57$ mg/L/ppm and $9.50{\pm}2.41$ mg/L/ppm, respectively, with or without respirator. There was seasonal differences of NMF in urine adjusted by DMF in air, $7.63{\pm}2.74$ mg/L/ppm in summer and $4.53{\pm}2.29$ mg/L/ppm in winter. The urinary NMF concentration which corresponds to 10 ppm of ambient DMF was 52.7 mg/L (r=0.650, n=128). Considering the difference of the route of exposure which resulted from the compliance of wearing personal protective equipment, the estimated contribution of respiratory and dermal exposure route for DMF was 48.5% vs. 51.5%.

Study on the Development of SCBA Belt for Firefighters (소방용 등지게 벨트의 제품개발에 관한 연구)

  • Kang, Minyoung;An, Seungkook;Lee, Sunhee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.3
    • /
    • pp.537-547
    • /
    • 2017
  • This study evaluates the wearing performance of a self-contained breathing apparatus (SCBA) belt for firefighters in Korea. A SCBA belt design was suggested based on the wearing evaluation of a SCBA belt; subsequently, prototypes I and II were created. A wearing evaluation of prototypes with improved design and design preference was performed. Six designs elements of the SCBA belt for firefighters were suggested based on the survey results of wearing the SCBA belt and for the SCBA belt design preference for use by firefighters. First, belt material should be made of black high-strength aramid textiles. In addition, Velcro should be used to attach and detach retroreflective and fluorescent materials along with various colors for visibility. Second, the chest belt should be made of the same material used for other parts; in addition, the chest belt should be moved to the center for center of gravity and a cobra buckle should be applied. Third, an O-ring should be applied to the back and the belt connected to the O-ring should distribute the weight in six axes. Fourth, a detachable air respirator should be able to separate by using upper and lower cobra buckles. Fifth, a separable leg belt and a detachable pocket are also suggested. Sixth, a ring for walkie-talkies, alarms and equipment as a fabric ring are also suggested. Prototype III with an improved design was created based on the results of the design suggestion.

Improvement for the Job Safety in the Scene Activities of Fire Fighters (소방공무원의 현장활동 안전성 확보를 위한 개선방안)

  • Kim, Jong-Seo;Lee, Dong-Ho;Park, Jong-Tae
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.58-63
    • /
    • 2014
  • This study was performed to propose measures to improve and secure safety in the scene activities of firefighters. First, the majority of firefighters thought that working environment and equipment in fire station were inadequate for perforeming work tasks safely. Second, influential factors threatening safe scene activities mainly arose externally such as insecure working conditions of firefighting or emergency scene. Third, improvement in working environments was pointed out as the most urgent issue to secure safety. Firefighters recognized the expansion of field workforce in system, personnel management and the foundation of hospitals for firefighters hospital in working environment, and the development and distribution of safe equipment and change and inspection of air respirator facepiece on regular basis in equipment as urgent issues to be improved.

Integrated Command System for Firefight Satety in Special Disaster Area (특수재난현장 진압대원의 안전을 위한 통합 지휘시스템에 관한 연구)

  • Roh, Tae-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.98-108
    • /
    • 2015
  • An integrated command system is critical for the safety of firefighters and effective work in the headquarters of a special disaster areas such as natural disaster or large man-made hazard. The integrated command system requires environmental information such as temperature, humidity, and $CO_2$ levels, as well as personal physical information such as pulse and air respirator levels. An Analog to Digital Converter (ADC) chip converts sensed information into digital signals, and a Micro Controller Unit (MCU) transmits the digital signals to a transmission board using serial communication through a Serial Peripheral Interface (SPI). The digital signals are saved in a transmission board and transmitted to the integrated command system by a Radio Frequency (RF) unit. The location of fire-fighters in a building are determined using a gyro sensor and an inertial sensor. The collected information is applied to the integrated command system for firefighter safety and to ensure that they can effectively carry out their duties. Tthis study theoretically and experimentally investigated the technologies of RF transmission, indoor position, and an integrated command system that supports decision making using the transmitted information.