• Title/Summary/Keyword: Air pressure variation

Search Result 375, Processing Time 0.025 seconds

Characteristics of Long-Range Transport of Air Pollutants due to Different Transport Patterns over Northeast Asia (동북아시아 대기오염물질의 이동 패턴에 따른 장거리 수송 특성 연구)

  • Park, Sin-Young;Kim, Yun-Jong;Kim, Cheol-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.2
    • /
    • pp.142-158
    • /
    • 2012
  • This paper investigates the physical and chemical characteristics of long-range transport (LRT) process of air pollutants by employing the MM5-CMAQ and its comparison with local emission dominant (LED) case over northeast Asia. We first classified high air pollution days into LRT and LED cases based on the synoptic meteorological variables of vorticity and geostrophic wind speed/direction at a geopotential level of over 850hPa. LRT cases are further categorized into three types of transport patterns (LRT-I-III) according to the air mass pathways from source regions. LRT-I-III are originated from northern, central, and southern China, respectively, identified by back trajectory analysis. Three LRT-I-III groups have different and unique locations of high pressure and transport pathways. The chemical characteristics showed that the simulated spatial distributions varied in terms of locations of maximum concentrations and the temporal variation of surface concentrations. The primary air pollutants such as $NO_x$, $PM_{10}$ and $SO_2$ of all of three LRT cases are well transported into Korea peninsula with different concentration levels. Of LRT cases, LRT-II has the greatest effect on air quality of Korea peninsula, followed by LRT-I and LRT-III. In comparison with LRT, the LED case shows relatively higher air pollution concentrations in general, but showed a variety of different air quality levels following the emission strength pattern. These widely varying patterns are impling the case dependent multi-directional approach for the development of indicators of long-range transport process over northeast Asia.

Change of Coastal Upwelling Index along the Southeastern Coast of Korea (동해 남부 연안용승지수의 변화)

  • SHIN, CHANG-WOONG
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.24 no.1
    • /
    • pp.79-91
    • /
    • 2019
  • Long-term trends and recent variations of upwelling index (UI), which affects significantly ecosystem in southwestern part of the East Sea, were investigated. The UI was calculated with the NCEP/NCAR reanalysis data from January 1948 to September 2018. The mean UI has positive value that causes upwelling in April to August with a peak in July. The long-term reducing trend of UI was in statistically significant in June and July, and the sum of UI in May, June and July also showed same result. Through the atmospheric pressure analysis around the Korean peninsula, it was found that the trend of the UI was the influence of the pressure change trend in the northwestern region ($35-50^{\circ}N$, $114-129^{\circ}E$) of the southwestern part of the East Sea. Investigating UI in recent 7 years from 2012 to 2018, it was revealed that the UI was bigger than 3 times of standard deviation in July 2013. This was result from the sea level pressure difference became larger in the southwestern part of the East Sea than normal year due to the lowered air pressure in the northeastern region of China and the strengthened high air pressure of western peripheral of the North Pacific High. On the other hand, the UI in July 2018 was negative when the impact of the North Pacific High and the low air pressure in the northeastern China was weak. Due to the decreasing trend of UI and its large year-to-year variation in southwestern part of the East Sea, continuous monitoring is necessary to know the influence of coastal upwelling on the ecosystem.

Structural Variation of Methane/Air Premixed Flame Caused by the Intervention of Ultrasonic Standing-wave (정상 초음파장의 간섭에 의한 메탄/공기 예혼합화염의 구조 변이)

  • Seo, Hang-Seok;Lee, Sang-Shin;Kim, Jeong-Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.6
    • /
    • pp.1-6
    • /
    • 2011
  • An experimental study has been conducted to scrutinize into the influence of ultrasonic standing wave field on the variation of methane/air premixed flame structure. Visualization technique utilizing the Schlieren method is employed for the observation of premixed flame propagation. The shape of flame front and local flame velocity are measured according to the variation of reactants pressure and chamber opening/closing condition. The flame fronts affected by the standing wave are clearly distorted but the vertical locations of frontal dents do not undergo any appreciable change. The influence of standing wave on the flame front becomes more prominent as the flame propagates downward. It is found that the propagation velocity of flame front with excitation of standing wave is greater than the case without the excitation. It is eventually revealed that the flame is deformed to lotus-shaped one by the vivid interaction of ultrasonic standing-wave with the reflected wave coming from the right side.

Study on Filter Drag Due to the Change of Operation Conditions in a Pulse Air Jet-type Bag Filter[I] (충격기류식 여과집진장치에서 운전조건 변화로 인한 여과저항에 관한 연구[I])

  • Ryu, Jae-Yong;Suh, Jeong-Min;Park, Jeong-Ho;Jeon, Bo-Kyung;Choi, Kum-Chan;Son, Yoyng-Il
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.449-458
    • /
    • 2007
  • Research results for the pressure drop variance depending on operation conditions such as change of inlet concentration, pulse interval, and face velocity, etc., in a pulse air jet-type bag filter show that while at $3kg/cm^2$ whose pulse pressure is low, it is good to make an pulse interval longer in order to form the first layer, it may not be applicable to industry because of a rapid increase in pressure. In addition, the change of inlet concentration contributes more to the increase of pressure drop than the pulse interval does. In order to reduce operation costs by minimizing filter drag of a filter bag at pulse pressure $5kg/cm^2$, the dust concentration should be minimized, and when the inlet dust loading is a lower concentration, the pulse interval in the operation should be less than 70 sec, but when inlet dust loading is a higher concentration, the pulse interval should be below 30 sec. In particular, in the case that inlet dust loading is a higher concentration, a high-pressure distribution is observed regardless of pulse pressure. This is because dust is accumulated continuously in the filter bag and makes it thicker as filtration time increases, and thus the pulse interval should be set to below 30 sec. If the equipment is operated at 1m/min of face velocity, while pressure drop is low, the bag filter becomes larger and thus, its economics are very low due to a large initial investment. Therefore, a face velocity of around 1.5 m/min is considered to be the optimal operation condition. At 1.5 m/min considered to be the most economical face velocity, if the pulse interval increases, since the amount of variation in filter drag is large, depending on the amount of inlet dust loading, the operation may be possible at a lower concentration when the pulse interval is 70 sec. However, for a higher concentration, either face velocity or pulse interval should be reduced.

A numerical study on heat transfer and pressure drop of plate heat exchanger using at seawater air conditioning with the variation of channel spaces (채널 간격 변화에 따른 해수냉난방용 판형 열교환기의 열전달과 압력강하에 대한 수치해석적 연구)

  • Kim, Hyeon-Ju;Lee, Ho-Saeng;Yoon, Jung-In;Son, Chang-Hyo;Jung, Young-Kwon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.704-709
    • /
    • 2014
  • Plate heat exchanger is being applied in the field of marine plants and chemical industry, such as OTEC and SWAC equipment. The study aims to interpret the heat transfer and pressure drop characteristics of plate heat exchangers to determine the geometric design parameters such as the channel space. In this study, heat transfer performance was numerically studied with respect to the variation of channel spaces. The results from numerical analysis indicated that the j factor was linearly decreased with the flowrate of seawater over every cases. As the flowrate of water increased with respect to channel spaces, the j factor decreased linearly. And the f factor decreased linearly with the increase of flowrate. When the channel space is 2.8~3.2 mm and 3.2~3.2 mm, respectively, the area goodness factor of plate heat exchanger showed the highest performance.

An Analysis of Anomalous Radon Variation Caused by M5.8 Gyeong-ju Earthquake (규모 5.8 경주 지진에 의한 토양 내 라돈농도의 이상변화 분석)

  • Kim, Jin-seop;Kim, Minjun;Kim, Sunwoong;Lee, Hyomin
    • Economic and Environmental Geology
    • /
    • v.51 no.1
    • /
    • pp.1-13
    • /
    • 2018
  • The radon concentration in soil varies with environmental factors such as atmospheric temperature and pressure, rainfall and soil temperature. The effects of these factors, therefore, should be differentiate in order to analyzed the anomalous radon variation caused by earthquake events. For these reasons, a comparative analysis between the radon variations with environmental factors and the anomalous variations caused by Gyeong-ju earthquake occurred in September 12, 2016 has been conducted. Radon concentration in soil and environmental factors were continuously measured at a monitoring ste located in 58Km away from earthquake epicenter from January 01, 2014 to May 31, 2017. The co-relationships between radon concentration and environmental factors were analyzed. The seasonal average radon concentration(n) and the standard variation(${\rho}$) was calculated, and the regions of ${\pm}1{\rho}$ and ${\pm}2{\rho}$ deviations from seasonal average concentration were investigated to find the anomalous radon variation related to Gyeong-ju earthquake. Earthquake effectiveness and q-factor were also calculated. The radon concentration indicated the seasonal variation pattern, showing high in summer and low in winter. It increases with increasing air temperature and soil temperature, and has the positive co-relationships of $R^2=0.9136$ and $R^2=0.8496$, respectively. The radon concentration decreases with increasing atmospheric pressure, and has the negative co-relationships of $R^2=0.7825$. Four regions of ${\pm}2{\rho}$ deviation from average seasonal concentration (A1: 7/3~7/5, A2: 7/18, A3: 8/4~8/5, A4: 10/17~10/20) were detected before and after Gyeong-ju earthquake. A1, A2, A3 were determined as the anomalous radon variation caused by the earthquake from co-relationship analyses with environmental factors, earthquake effectiveness and q-factor. During the period of anomalous radon variation, correlation coefficients between radon concentration and environmental factors were significantly lowered compared to other periods such as air temperature ($R^2=0.2314$), soil temperature ($R^2=0.1138$) and atmospheric pressure ($R^2=0.0475$). Annual average radon concentration was also highest at 2016, the year of Gyeong-ju earthquake.

Characteristics of Climate in the Eastern Coastal Regions of Korean Peninsula (한반도 동해안 지방의 기후 특성)

  • KIM Young-Seup;HAN Young-Ho;SHIN Soo-Kyeong;HONG Sung-Kun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.3
    • /
    • pp.314-325
    • /
    • 1994
  • Characteristics of climate in the eastern coastal regions of Korean Peninsula were studied using the meteorological and coastal sea surface temperature (SST) data which were compiled from 1961 to 1990. In the winter half year (from October to March), air temperature (AT) and precipitation of the eastern coastal regions were considerably higher than those of the western and inland regions, but relative humidity was $8{\sim}15\%$ lower. AT of coastal regions was closely related to the variation of coastal SST. These characteristics were more noticeable in the eastern coastal areas and in lower latitude regions. Quantitatively, the $1.0^{\circ}C$ variation of coastal SST may have resulted in the $1.0^{\circ}C{\sim}1.5^{\circ}C$ variation for AT in coastal regions. In the same way as temperature, vapor pressure in coastal regions was also influenced by coastal SST. Relative humidity change corresponding to the $1.0^{\circ}C$ variation of coastal SST was $3.7\%{\sim}6.5\%$. Net heat exchange amounts were positive (sea surface gaining energy) in all coastal regions. Sea surface gained net heat from March to September, and lost it from October to February. Variation of AT in coastal regions was also related to the sensible and latent heat exchanges. Sensible and latent heat amount corresponding to the $1.0^{\circ}C$ variation of AT were $10Wm^{-2}$ at Kangnung, and $8Wm^{-2}$ at Pohang and $13Wm^{-2}$ at Pusan.

  • PDF

Analysis and Design of Micro Solenoid (마이크로 솔레노이드의 해석 및 설계)

  • Jeon, Y.S.;Bae, S.K.;Kim, D.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.4
    • /
    • pp.14-20
    • /
    • 2006
  • Recently, the on-off solenoid valves have been focused on core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for bio-medical applications. A key characteristics for on-off solenoid valve, operated by compressed air, are high speed response and great repeatability. Indeed, it is also important to keep the pressure on the cross-sectional area of the poppet to be constant regardless of the fluctuation of the pressure exerted on the ports. In this study, we have designed and analysed the high-speed and high flow rate on-off solenoid valve using the analogy of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, flow field characteristics was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D simulation using distribution curve of the force by working the front poppet.

  • PDF

Optimization study on fuel cell cathode oxygen flow path for Unmanned Aerial Vehicle using computational visualization (전산 가시화를 통한 무인 항공기용 연료전지 양극 산소 유로 최적화 연구)

  • Jeon, Ji-A;Lee, Jae-Jun;Song, Young-Su;Kim, Min-Su;Kim, Gun Woo;Na, Youngseung;Rhee, Gwang Hoon
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.1
    • /
    • pp.85-92
    • /
    • 2019
  • Numerical visualization is conducted to confirm the variation of flow characteristics and pressure drop by the shape of channels on the cathode flow path in hydrogen fuel cells for unmanned aerial vehicles(UAVs). Generally, a light-weight fan is commonly used rather than a heavy air compressor at UAVS. However, in case of blower fan, a large pressure drop in the flow path causes the blocking of the oxygen supply to the fuel cell. Therefore, the uniformity of flow inside the cathode has to be achieved by changing the shape of the cathode. The flow channel, the duct shape, and the diameter of the fan are changed to optimize the flow path. As a result, it is confirmed that the optimal flow path can decrease the velocity difference between the center and outer flow by 1.8%. However, It should be noted that the channel size can increase the pressure drop.

Analysis of Flow and Heat Transfer in Swirl Chamber for Cooling in Hot Section (고온부 냉각을 위한 스월챔버내의 유동 및 열전달 해석)

  • Lee K. Y.;Kim H. M.;Han Y. M.;Lee S. Y.
    • Journal of computational fluids engineering
    • /
    • v.7 no.3
    • /
    • pp.9-16
    • /
    • 2002
  • Most of modem aerospace gas turbines must be operated at a gas temperature which is several hundreds of degrees higher than the melting temperatures of the materials used in their construction. Complicated cooling schemes need to be employed in the combustor walls and in the high pressure turbine stages. Internal passages are cast or machined into the hot sections of aero-gas turbine engines and air from the compressor is used for cooling. In many cases, the cooling system is engineered to utilize jets of high velocity air, which impinge on the internal surfaces of the components. They are categorized as 'Impinging Cooling Method' and 'Vortex Cooling Method'. Specially, research of new cooling system(Vortex Cooling Method) that overcomes inefficiency of film cooling and limitation of space. The focus of new cooling system that improves greatly cooling efficiency using less amount of cooling air on surface heat transfer elevation. Therefore, in this study, a numerical analysis has been peformed for characteristics of flow and heat transfer in the swirl chamber and compared with the flow measurements by LDV. Especially, for understanding high heat transfer efficiency in the vicinity of wall, we considered flow structure, vortex mechanism and heat transfer characteristics with variation of the Reynolds number.