• Title/Summary/Keyword: Air pollutants concentration

Search Result 617, Processing Time 0.037 seconds

A Study on the Control Performance for Hazardous Gases by Surface Discharge induced Plasma Chemical Process (연면방전의 플라즈마 화학처리에 의한 유해가스제어 성능에 관한 연구)

  • 이주상;김신도;김광영;김종호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.185-190
    • /
    • 1995
  • Recently, because of the worse of the air pollution, the excessive airtught of building and the inferiority of air conditioning system, the development of high efficiency air purification technology was enlarged to the environmental improvement of an indoor or a harmful working condition. The air purification technology has used chemical filters or charcoal filters or charcoal to remove hazardouse gaseous pollutants (SO$_{x}$, NO$_{x}$, NH$_{3}$, etc.) by air pollutant control technology, but they have many problems of high pressure loss, short life, wide space possession, and treatment of secondary wastes. For these reason, the object of reasearch shall be hazardous gaseous pollutants removal by the surface discharge induced plasma chemical process that is A.C. discharge of multistreams applied A.C. voltage and frequency between plane induced eletrode and line discharge eletrode of tungsten, platinum or titanium with a high purified alumina sheet having a film-like plane. As a result, the control performance for hazardous gaseous pollutants showed very high efficiency in the normal temperature and pressure. Also, after comtact oxidation decomposition of harmful gaseous pollutants, the remainded ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.rea.

  • PDF

Concentrations of Air Pollutants Measured at Kosan during ACE-Asia Intensive Observation Period (ACE-Asia 집중관측기간에 제주고산에서 측정한 대기오염물질의 농도 분포특성)

  • ;;;;Jianzhen Yu;Keith Bower
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.487-501
    • /
    • 2002
  • The concentrations of gaseous (NO$_{x}$, SO$_2$, and $O_3$) and particulate (Elemental Carbon, EC and Organic Carbon, OC) pollutants were measured to evaluate the air quality of Kosan. Samples were taken at Kosan during ACE-Asia (Asian Pacific Regional Aerosol Characterization Experiment) IOP (Intensive Observation Period) (2001. 3. 21~2001. 5. 5). The mean concentrations of $O_3$(46.3$\pm$10.4 ppb) is higher than those at urban area such as Seoul and Busan in Korea. On the other hand, the mean concentrations of other gaseous species, NO$_{x}$(4.73$\pm$3.42 ppb) and SO$_2$(0.62$\pm$0.63 ppb) are lower than those at great cities. So we concluded that there are a few primary sources emitting atmospheric pollutants. The concentration of EC is higher and the concentration of OC is similar with or higher than those at other background sites. The recent EC concentration is higher than those measured before at Kosan. We concluded that there are more primary sources than other background sites and the amount of primary source have increased recently in Jeju. Backward trajectory and co..elation analysis were used to study where the air masses originated and distinguish the source of pollutants. While NO$_{x}$ and $O_3$ were mainly emitted and formed from Jeju inland area, concentrations of SO$_2$, OC and EC were affected by Asian Dust from China. Using the mean relative standard deviation of ozone, cleanness coefficient was obtained. The cleanness coefficient value, is 1.6 times larger than the value in 1992. Recently, the air quality of Kosan has been contaminated because of the Asian Dust events since spring and the rapid industrialization development.pment.

The Ivestigation and Estimate of Influence on Air Quality by the Exhaust of Air Pollutant from Facility of the District Heating Located in Small City (중소도시에 위치한 집단 열 공급시설에서 배출되는 대기오염물에 의한 주변 대기질의 영향 조사 및 예측)

  • Yeon, Ik-Jun;Kim, Kwang-Yul
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.1-10
    • /
    • 2003
  • This study was aimed to investigate the influence on the vicinity by air pollutant generated from facility of the district heating located in local small town. We selected the seven areas arround the surroundings of facility of the district heating, compared the air quality evaluated before and after operations of the facility, and estimated the diffusion of air pollutant exhausted from the facility using a ISC model. The result was that the concentration of TSP before and after operations of the facility was 89${\sim}$94${\mu}$g/m$^3$,and 72${\sim}$81${\mu}$g/m$^3$, respectively and the latter showed a decline in concentration. Also, there was no relationship between straight distance from the facility of the district heating and the concentration of TSP. This result was applicable to cases of PM-10 and SO$_2$. We also investigated the influence on the air around the neighbored area by air pollutant produced from facility of the district heating using ISCLT3 model. The adding-concentrations of TSP, SO$_2$,NO$_2$, and CO were 0.0019${\sim}$0.00183${\mu}$g/m$^3$, 0.0029${\sim}$0.5648ppb, 0.2924${\sim}$l.9837ppb,and 0.0087${\sim}$0.0590ppb, respectively. It is predicted that each concentration is added to pollutant exhausted from facility of the district heating and is about 1/100${\sim}$1/180,000 of present air quality. This has a tiny influence on general air quality. According to this analysis, the concentration of air pollutant is less effected to pollutants expected by the facility of the district heating than other pollutants emitted from mobil source or industrial complex, and etc.

The Analysis of Atmospheric Flow Field and Air Quality According to the High Level Ozone Case on Gwangyang Bay (광양만 권역에서의 고농도 오존 사례에 대한 기상 및 대기질 분석)

  • Choi, Hyun-Jung;Lee, Hwa-Woon;Leem, Heon-Ho;Song, Jae-Hwal
    • Journal of Environmental Science International
    • /
    • v.17 no.7
    • /
    • pp.743-753
    • /
    • 2008
  • Gwangyang Bay is often severely confronted by photochemical pollutants due to its location and dense emissions. It is located in a basin on the south coast of the Korean peninsula and is crossed by a remarkable cluster of hills and mountains of a small horizontal scale that forms a channel. Clearly, the air flow field has a great influence on the dispersion of air pollutants. The characteristics of the wind flow patterns have an important effect on the dispersion of pollutants emitted. In these situations, the distribution of the ozone concentration is extremely complicated because of the superposition of circulations of the air flow fields, especially in complex coastal region. In this study, we examined the distribution of the high level ozone on Gwangyang Bay particularly during the episode day (for 5 years). Among these days, A high level ozone was induced by the development of a sea/land breeze local circulation system, as well as by an anabatic/catabatic flow from the mountains and valley with weakening of the synoptic wind. High level ozone distribution pattern(6 types) on Gwangyang bay is analyzed and the comparison of each pattern reveals substantial localized differences in intensity and distribution of ozone concentration from the site coherence and UPA analysis of ozone concentration. The observed VOC concentration had much difference in concentrations and daily variations between Jungdong and Samil.

Analysis on High Concentration Air Pollution Cases in Gimhae Region Using the WRF Numerical Model (중규모 수치모델을 이용한 김해지역 고농도 대기오염 사례 분석)

  • Jung, Woo-Sik;Lee, Bo-Ram;Park, Jong-Kil;Do, Woo-Gon
    • Journal of Environmental Science International
    • /
    • v.22 no.8
    • /
    • pp.1029-1041
    • /
    • 2013
  • In this study, eight episode days of high-concentration $PM_{10}$ occurrences in the Gimhae region between 2006 and 2011 were analyzed. Most of them appeared in winter and the highest concentration was observed around 12 LST. Furthermore, the wind direction, wind velocity, and temperature elements were compared with observed values to verify the WRF numerical simulation results used in this study, and they simulated well in accordance with the trend of the observed values. The wind was generally weak in the high-concentration episode days that were chosen through surface weather chart and the numerical simulation results for wind field, and the air pollutants were congested due to the effects of the resulting local winds, thereby causing a high concentration of air pollutants. Furthermore, the HYSPLIT model was performed with the WRF numerical simulation results as input data. As a result, they originated from China and flowed into Gimhae in all eight days, and the lowest concentration appeared on the days when recirculation occurred.

A Three Dimensional Numerical Simulation of $SO_2$ Concentration in Relation with Atmospheric Flow in Pusan Area, Korea (부산지역에서의 대기흐름과 관련된 $SO_2$농도 3차원 수치모의)

  • 장은숙;이화운
    • Journal of Environmental Science International
    • /
    • v.6 no.4
    • /
    • pp.359-367
    • /
    • 1997
  • The Characteristics of atmospheric flow and dispersion of air pollutants in the mountainous coastal area were studied using three-dimensional model by the combination of land/sea breezes and transport. It was then applied to Pusan city. As the urban area considered In this study is located in a mountainous coastal area, the atmospheric flow is strongly affected by the land/sea breezes and mountain/valley winds. The typical effects of land/sea breezes on the dispersion and the characteristics of pollutants movement in the region were analysed. The model has been proved to be an useful tool to prodict real time air pollutants transport as shown by the results of application studies In Pusan, Korea which Is an urbanized coastal area with mountainous topography. It was found that the pollutants are differently transported and concentrated as going Inland by the Influence of the sea breeze with topographic changes. By comparing the pollutants concentrations of the stimulated results with those of the observational results, It is shown that stimulated results in this study are in qualitative agreement with observational ones.

  • PDF

Numerical Analysis of Wintertime Air Pollution in East Asia Region Using Long-Range Transport Model

  • Jang, Eun-Suk
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.2
    • /
    • pp.103-110
    • /
    • 2000
  • In order to understand the wintertime intermittent characteristics of the trans-boundary air pollutant transport observed in East Asia, a numerical simulation of the long-range transport of pollutants was applied using an atmospheric transport model(STEM-II). The numerical simulation was carried out for the entire month of January 1997 and specific atmospheric aerosol (including sulfate, nitrate, and other ion compounds0 observation data were compared from four observation sites(Cheju Island, Kanghwa Island, Dazaifu, and Fukue Island). The observation data revealed that concentration peaks were intermittently observed at 3 to 4-day intervals plus the four observation sites exhibited a very similar spatial variation. The horizontal and spatial scale of the heavily polluted air masses was analyzed based on numerical results. The mechanism of the intermittent transport of air pollutants was clearly explained by a comparison of the observed data with the numerical output. It was found that the wind pattern variations associated with the synoptic scale pressure system changes play an extremely important role in the transport of pollutants in this region.

  • PDF

Evaluation on Indoor Air Quality by Statistical Analysis of Indoor Air Pollutants Concentration in a Seoul Metropolitan Underground Railway Station (서울시 지하역사 실내오염물질 농도자료의 통계분석을 통한 실내공기질 특성 평가)

  • Yim, Bongbeen;Lee, Kyusung;Kim, Jooin;Hong, Hyunsu;Kim, Jangwon;Jo, Kyung-Ho;Jung, Eulgyu;Kim, Inkyu;An, Yeonsun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.3
    • /
    • pp.233-244
    • /
    • 2014
  • The objective of this study was to explore the characteristics of concentration of indoor air pollutants, such as $PM_{10}$, $CO_2$, and $NO_2$, measured by tele-monitoring system in a Seoul Metropolitan underground railway station from January 1, 2008 to December 31, 2012. The annual average concentration of indoor air pollutants actually varied over a wide range and was found to exhibit marked variation with time and measurement sites (tunnel inlet, platform, and concourse). After installing platform screen doors, the average $PM_{10}$ concentration on platform and concourse was decreased by 43.8% and 31.2%, respectively during the study periods. The relationship between the concentration of $PM_{10}$ and meteorological parameters (relative humidity and rainfall) or the Asian dust events was regarded as statistically significant. The correlations between the number of boarding/alighting passengers and $PM_{10}$, $CO_2$, and $NO_2$ were calculated. A p-value of less than 0.01 was regarded as significant except $NO_2$. The I/O ratio of $PM_{10}$ concentration was elevated after a congested time (about 08:00 am). The average I/O ratios of $NO_2$ were observed in concourse and platform on 03:00 am with $1.76{\pm}0.91$ and $1.50{\pm}0.51$, respectively. The average daily variation of standard excess rate of $PM_{10}$ and $NO_2$ concentration in concourse and platform was investigated. The highest standard excess rate was observed on 21:00 (09:00 pm).

Study on the Distribution and Characteristics of Heavy Metals in Ambient Air of Kimhae, Kyongnam of Wintertime (경남 김해지역의 동계 대기중 중금속 분포와 특성)

  • 정성욱;전병일
    • Journal of Environmental Science International
    • /
    • v.5 no.4
    • /
    • pp.453-462
    • /
    • 1996
  • This study was conducted to evaluate the level of atmospheric heavy metals and the relationship of that concentration with weather conditions. This research monitored the concentration of Total Suspended Particulates (TSP) at every three hours by using High Volume Air Sampler from December 24th, of 1995 to Febuary 20th, 1996 in Kimhae area, which recently became a rapidly growing residential and industrial sitc. The items such as air-temperature, relative humidity, radition, wind speed, and wind direction were monitored by using Atmospheric Weather System at the same time. From the collected TSP, the concentration of heavy metals were analyzed by using the Atomic Absorption Spcetrophotometry. The mean concentration of TSP was 110.4 $\mu\textrm{g}$/$m^3$, and the mean concentration of lead (Pb), copper(Cu), chromium (Cr), manganese (Mn), cadmium (Cd), were 0.837 $\mu\textrm{g}$/$m^3$, 0486 $\mu\textrm{g}$/$m^3$, 0.264$\mu\textrm{g}$/$m^3$). The concentration of Pb and Mn was higher in the moring and that of Cu, Cr and Cd was higher in the afternoon and the evening. Regarding the relationship between the concentration of pollutants and weather condition, the-concentration TSP revealed positive correlation with temperature, humidity, wind speed, but negative correlation with tradition (p<0.01). The concentration of Mn revealed positive correlation with temperature and humidity, but negative correlation with wind speed (p<0.01). And the the concentration of pollutants and weather condition revealed higher correlation within the same time period. In summary, the paralleled mornitoring of air conditions and weather condition should be recommended to. get the correct informations concerning the pollution and to prevent the deterioration of air conditions.

  • PDF

Health and environmental risk assesment of air pollutants in Gyeongju and its vicinities(I) (경주 주변지역 대기오염물질의 보건.환경 위해성 평가(I))

  • Jung, Jong-Hyeon;Choi, Won-Joon;Leem, Heon-Ho;Park, Tong-So;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3740-3747
    • /
    • 2009
  • To protect the citizens' health of Gyeongju and to secure basic data for the assessment of health and environmental risk, distribution characteristics of meteorological elements were investigated and numerical simulation of wind field using RAMS model was carried out. In addition, measurement and analysis of air pollutants, forecasting the behavior air pollutants using ISC-AEROMOD view, and health and environmental risk-influenced zones were defined through managing air polluting materials to prevent health damage and property damage. According to the survey results of air pollution in Gyeongju and surroundings, average annual concentration of air pollutants in Gyeongju was slightly lower than that in Pohang and Ulsan areas, but concentration of particulate matters and nitrogen dioxide at Gyeongju Station Square and Yonggang Crossing were sometimes higher than that in Pohang and Ulsan areas. Results of the modeling of moving and diffusion of air pollutants that affect citizens' health showed that parts of the 1st through 4th industrial complexes together with POSCO were included in particulate matters and sulfur dioxide influenced areas in Pohang Steel Complex area, and that Haedo-dong, Sangdae-dong, Jecheol-dong and Jangheung-dong in Pohangnam-gu represented locally worsened air quality due to a quantity of air pollutant emission from dense steel industries and large scale industrial facilities.