• 제목/요약/키워드: Air pollutants concentration

검색결과 613건 처리시간 0.026초

DME와 LPG 연료의 정적 예혼합 연소특성 (Constant Volume Premixed Combustion Characteristics of Dimethyl Ether and LPG Fuel)

  • 김태권;임문혁;장준영
    • 한국자동차공학회논문집
    • /
    • 제11권5호
    • /
    • pp.83-88
    • /
    • 2003
  • Measurements on the combustion characteristics of dimethyl ether(DME:$CH_3$O$CH_3$) as compared with LPC in constant volume combustion chamber have been conducted. The DME is a good alternative fuel having oxygen component in fuel. To elucidate the combustion characteristics of dimethyl ether as a fuel, the combustion pressures, combustion durations, and pollutants(NOx, $CO_2$, CO) are measured with equivalence ratios(Ø), and initial Pressures of fuel-air mixture. In the case of DME, the NOx concentration peaks in leu flame Ø = 0.85~0.9, and $CO_2$ concentration peaks at Ø=1.1, while the CO concentration abruptly rises at the condition of fuel-rich mixtures.

충주시 초미세먼지 (PM2.5)의 배출원 기여도 추정에 관한 연구 (Source Apportionment of Fine Particulate Matter (PM2.5) in the Chungju City)

  • 강병욱;이학성
    • 한국대기환경학회지
    • /
    • 제31권5호
    • /
    • pp.437-448
    • /
    • 2015
  • The purpose of this study is to present the source contribution of the fine particles ($PM_{2.5}$) in Chungju area using the CMB (chemical mass balance) method throughout the four seasons in Korea. The Chungju's annual average level of $PM_{2.5}$ was $48.2{\mu}g/m^3$, which exceeded two times higher than standard air quality. Among these particles, the soluble ionic compounds represent 54.2% of fine particle mass. Additionally, the OC concentration in Chungju stayed similar to other domestic cities, while the EC concentration decreased significantly compared to other domestic/international cities. The concentration of sulfur represented the highest composition (8%) among the fine particle compounds. According to the CMB results, the general trend of the $PM_{2.5}$ mass contributors was the following: secondary aerosols (50.5%: ammonium sulfate 26.5% and ammonium nitrate 24.0%) > gasoline vehicle (18.3%) > biomass burning (11.0%) > industrial boiler (6.0%) > diesel vehicles (4.4%). The contribution of the secondary aerosols was the main cause than others. This impact is assumed to be emitted from air pollutants of urban cities or neighbor countries such as China.

Evaluation of the Effect of Regional Pollutants and Residual Ozone on Ozone Concentrations in the Morning in the Inland of the Kanto Region

  • Kiriyama, Yusuke;Shimadera, Hikari;Itahashi, Syuichi;Hayami, Hiroshi;Miura, Kazuhiko
    • Asian Journal of Atmospheric Environment
    • /
    • 제9권1호
    • /
    • pp.1-11
    • /
    • 2015
  • Increasing ozone concentrations are observed over Japan from year to year. One cause of high ozone concentration in the Kanto region, which includes areas inland from large coastal cities such as metropolitan Tokyo, is the transportation of precursors by sea breezes. However, high ozone concentrations are also observed in the morning, before sea breezes approach inland areas. In this point, there would be a possibility of residual ozone existing above the nocturnal boundary layer affects the ozone concentration in the following morning. In this study, we utilized the Weather Research and Forecasting model and the Community Multiscale Air Quality model to evaluate the effect of regional precursors and residual ozone on ozone concentrations over the inland Kanto region. The results show that precursors emitted from non-metropolitan areas affected inland ozone concentrations more than did precursors from metropolitan areas. Moreover, calculated results indicate downward transportation of residual ozone, resulting in increased concentration. The residual ozone was also affected by precursors emitted from non-metropolitan areas.

The Temporal and Spatial Distribution of Volatile Organic Compounds(VOCs) in the Urban Residential Atmosphere of Seoul, Korea

  • Anthwal, Ashish;Park, Chan-Goo;Jung, Kweon;Kim, Min-Young;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • 제4권1호
    • /
    • pp.42-54
    • /
    • 2010
  • Automobile emissions have caused a major hydrocarbon pollution problem in the ambient air of many cities around the world. This study was conducted to measure the pollution status of volatile organic compounds (VOCs) in some urban residential areas in Seoul, Korea. A total of 20 VOCs (11 aromatic and 9 chlorinated species) were identified at 4 urban residential sites in Seoul, Korea from February 2009 to July 2009. Comparison of total VOC (TVOC) concentration data indicated the dominance of the aromatic species with the maximum (72.2 ppbC) at Jong Ro (JR) and the minimum at Yang Jae (33.4 ppbC). The peak concentration of TVOC occurred during spring at all sites with an exception at Gang Seo (GS), where it was recorded during winter. The distribution of individual VOCs at the study sites was characterized by high toluene concentration. A strong correlation of benzene was also observed with other VOCs and criteria pollutants at all sites (except YJ). The overall results of this study suggest that vehicular emissions have greatly contributed to the increase in VOC pollution at all the study sites.

대전지역 지하상가의 대기오염도에 관한 조사연구 (A Study on Air Pollution in the Underground Shopping Store of Taejon Area)

  • 양천회;류완호;장철현
    • 한국안전학회지
    • /
    • 제9권1호
    • /
    • pp.134-139
    • /
    • 1994
  • In order to assess the level of atmospheric pollution and to contribute the hearth improvement of residents in Taejon city, the authors were measured the concentration of air pollutants(CO, SO$_2$, NO$_2$, TSP, Pb, Cd, Cr) at three places of the control road in Taejon. The investigative research performed bimonthly from May 1993 to September 1993, and the places were the underground shopping stores of Taejon station, Dongyang department store and provincial goverment areas. The results of statistical analysis are as followings. \circled1CO :0.569~0.966ppm \circled2SO$_2$:0.084~0.170ppm \circled3NO$_2$:0.0045~0.022ppm \circled4TSP:249~299$\mu\textrm{g}$/㎥. \circled5Pb :0.366~1.157$\mu\textrm{g}$/㎥. \circled6Cd:0.016~0.025$\mu\textrm{g}$/㎥. \circled7 Cr : 0.198 ~0.290$\mu\textrm{g}$/㎥. The mean concentration of SO$_2$in Dongyang department store area was 0.17ppm, and it exceeded the ambient air quality standard by 0.02ppm. The concentration of TSP was higher than a standing rule of public hygiene, and it was very near to a standing rule of environmental preservation. The standing rule of indoor air pollution in underground shopping store have two different laws, the public hygiene and the environmental preservation. Therefore, it was difficult to judge what to do in such circumstance. In regarding to the laws, an environmental standard for air pollution in the underground space must unify into the standard of public hygiene.

  • PDF

Effect of Precipitation on Air Pollutant Concentration in Seoul, Korea

  • Kim, Suhyang;Hong, Ki-Ho;Jun, Hwandon;Park, Young-Jae;Park, Moojong;Sunwoo, Young
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권4호
    • /
    • pp.202-211
    • /
    • 2014
  • In this study, long-term rainfall data with irregular spatial distribution in Seoul, Korea, were separated into individual precipitation events by the inter-event time definition of 6 hours. Precipitation washout of $PM_{10}$ and $NO_2$ concentrations in the air considering various complex factors were analyzed quantitatively. Concentrations of $PM_{10}$ and $NO_2$ in the atmosphere were lower under condition of rainfall compared to that of non-precipitation, and a noticeable difference in average $PM_{10}$ concentrations was observed. The reduction of concentrations of $PM_{10}$ and $NO_2$ by rainfall monitored at road-side air monitoring sites was also lower than that of urban air monitoring sites due to continuous pollutant emissions by transportation sources. Meanwhile, a relatively smaller reduction of average $PM_{10}$ concentration in the atmosphere was observed under conditions of light rainfall below 1 mm, presumably because the impact of pollutant emission was higher than that of precipitation scavenging effect, whereas an obvious reduction of pollutants was shown under conditions of rainfall greater than 1 mm. A log-shaped regression equation was most suitable for the expression of pollutant reduction by precipitation amount. In urban areas, a lower correlation between precipitation and reduction of $NO_2$ concentration was also observed due to the mobile emission effect.

부산광역시 지하철역 지하공간의 대기오염 특성 (Analysis of air pollution in subway area of Busan Metropolitan City)

  • 이화운;장난심;곽진;이희령;김희만
    • 한국환경과학회지
    • /
    • 제11권3호
    • /
    • pp.169-176
    • /
    • 2002
  • The purpose of this study is designed to estimate the air quality of subway stations that have the underground platforms in Pusan Metropolitan City, from September to November 2000, over seven times. The subjects include Yonsan-dong station, Somyon station, Pusan station, Nampo-dong station, and Tushil station. The samplings were conducted at three points of each station, i.e. gate, ticket gates, and platforms. The major materials for analysis were CO, NO, NO$_2$, and $O_3$. The experiment was conducted at 7:00 pm with KIMOTO HS-seven Handy sampler and Tedlar Bag of SKC INC(U.S.A). In order to more fully understand station environments, we also measured temperature at each point. The results showed that $O_3$ average concentration at Yonsan-dong station was higher than others with 38~51 ppb. The average concentration of NO was high at ticket gate and platform at Somyon station(119 ppb, 122 ppb), Nampo-dong station(102 ppb, 100 ppb). These results show that the air pollution of stations with underground shopping malls was higher than others. At Somyon station having a junction station, NO and NO$_2$ concentration level of platform-2(noncrowded) was higher than platform-1(crowded). This is most likely due to the accumulation of air pollutants and inadequate ventilation systems.

한·중·일 PM10 국가 배경농도 최근 경향 분석 (Analysis of the Recent Trend of National Background PM10 Concentrations over Korea, China, and Japan)

  • 양금희;이종재;유영숙;장임석;임재현;이동원;김상균;김철희
    • 한국대기환경학회지
    • /
    • 제32권4호
    • /
    • pp.360-371
    • /
    • 2016
  • The goal of this research is to examine the recent decade-long (2000~2014) trends of national background concentrations over China, Japan, and Korea. Based on the Long-range Transboundary Air Pollutants in Northeast Asia (LTP) project, which is three-party collaboration project among three countries, we investigated the long-term trends of national background $PM_{10}$ concentrations in three countries over the recent 15 years, including the 2008 Beijing Olympic Game period. In accordance with the agreement among three countries, a total of 8 national background sites: three national background monitoring sites in China (2 sites in Dalian, and 1 in Xiamen), three sites in Korea (Ganghwa, Gosan, and Taean), and two sites in Japan (Oki and Rishiri), were chosen for the trend analysis. The results showed that Chinese background concentration recorded the highest level overall. However, the rapid declining recent trends of annual median ($50^{th}$-percentile) values were surprisingly detected since 2006 or 2007 in every site in China, with the most rapidly decreasing rate (- $18.6{\pm}10.3%$/year) over 2006~2007, and the second most rapidly decreasing rate (- $18.0{\pm}1.5%$/year) over 2007~2008. Based on the previous statistical literature, we concluded that this declining trends were due to the emission reduction of $PM_{10}$ concentrations in China for 2008 Beijing Olympic Game. In Korea, Ganghwa was also showing the decreasing trends over the recent years since 2006, which is also well accorded with the decreasing period of Chinese background concentrations. Taean also implied some impact of Beijing Olympic Game, showing small but detectable decreasing trends, while Gosan showed the increasing tendencies probably due to the near-urban influences. However, since 2012, most sites in both China and Korea showed strong increasing trends, undoubtedly implying the increasement of both emission in China and its long-range transport process toward Korea. Two sites in Japan, Oki and Rishiri recorded the lowest level of $PM_{10}$ level during whole period with the smallest deviations of measurements. Other discussions including the decade-long trends of $5^{th}$, $10^{th}$, $25^{th}$, $50^{th}$, $75^{th}$, $90^{th}$, $95^{th}$-percentiles of $PM_{10}$ background concentrations in three countries were also comparatively addressed here.

통풍에 의한 휘발성 유기화합물의 실내 거동 특성에 대한 연구 (A Study on Behavior Characteristics of Volatile Organic Compound Caused by Ventilation in a Room)

  • 김장우;정진도
    • 한국환경과학회지
    • /
    • 제15권11호
    • /
    • pp.1011-1016
    • /
    • 2006
  • Recently, volatile organic compound(VOC) has been noted as a main cause of air pollution. VOC, with its toxic and offensive odor, is hazardous to health. Furthermore indoor, underground and hish-rise buildings are preferable living spaces. People spend more than 80% of the day indoor, so indoor air pollution is a matter of importance. In Korea, from 2004, 10 types of indoor pollutants in public facilities have been identified. However, there is no standard for individual VOC, so the regulation has not yet effectively been carried out. In this study, we have studied on the diffusion of Benzene in a room using a numerical analysis for various air-controlled conditions consisted of door, window and ventilation system. This study investigates spatial concentration distribution and time-history of room-averaged benzene concentration for several cases. The results of this study show that when the room is ventilated by a small fan only for 30 minutes, the average concentration of benzene is decreased a very little, thus the impact to human body would be serious compared to the case of natural ventilation by window and door, In the case of natural ventilation by window and door, if the wind speed is higher than 0.5m/s, it takes small than 4 minutes for benzene to spread to the target concentration of $1.2mg/m^3$.

충남 지역 일부 학교의 PM10과 중금속 농도에 관한 연구 (The Study on Concentration of PM10 and Heavy Metal in Public Schools at Chung-Nam Area)

  • 손부순;송미라;김정덕;조태진;양원호;정태웅
    • 한국환경과학회지
    • /
    • 제17권9호
    • /
    • pp.1005-1013
    • /
    • 2008
  • In this study, in order to analyze the air quality of the indoor environments of schools, we measured the indoor, outdoor and personal exposure concentration level of $PM_{10}$ for 40 classrooms(20 old, 20 new) in chungnam area from June 22 to July 19 and from November 21 to December 30, 2003. 1. Old classrooms contained more dust than new classrooms; the average of respirable dust is $43.27\;{\mu}g/m^3$ for new classrooms while $53.38\;{\mu}g/m^3$ for old one. The exposure concentration level of respirable dust in new classrooms were in summer higher outdoors than indoors. The values were indoors $46.71\;{\mu}g/m^3$, outdoors $50.46\;{\mu}g/m^3$, and personal $41.62\;{\mu}g/m^3$. Meanwhile in winter indoors had a higher concentration level than outdoors, the values being indoors $39.11\;{\mu}g/m^3$, outdoors $34.86\;{\mu}g/m^3$, and personal $49.01\;{\mu}g/m^3$. 2. Cr concentration level within dust was slightly higher in summer indoors ($101.50{\pm}32.10\;ng/m^3$) and outdoors ($100.89{\pm}35.18\;ng/m^3$) than winter indoors ($85.80{\pm}48.95\;ng/m^3$) and outdoors ($74.43{\pm}38.93\;ng/m^3$), but in personal concentration level, winter was higher. The results of this research show insufficient understanding of health risks from indoor air pollution, and shows possible health problems to students from school indoor air pollution. As such, a logical and systematic education program for students about the importance of indoor air quality should be carried out. Also the results of $PM_{10}$ concentration level measurements emphasize the need for regular measurements of indoor / outdoor and personal concentration level. New classrooms in particular needs to be used after measuring pollutants and safety, and requires installation of a ventilation device in all classrooms to improve air quality.