• Title/Summary/Keyword: Air pollutants concentration

Search Result 613, Processing Time 0.028 seconds

The Effect of Ventilation and Concentration of Indoor Air Quality at Indoor Parking Lots (실내주차장의 실내공기질 농도특성 및 환기에 의한 저감효과)

  • Park, Jeong-Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.4
    • /
    • pp.241-247
    • /
    • 2010
  • Recently, indoor air quality (IAQ) has been one of the major concerns of people. Indoor parking lots are subject to be exposed to high concentrations of air pollutants emitted from vehicles. This study was performed to investigate indoor air quality (IAQ) at indoor parking lots. Sampling sites were selected 5 indoor parking lots. Target indoor air quality parameters include a number of criteria pollutants such PM$_{10}$, CO, CO$_2$, and HCHO. In addition, a variation of IAQ according to ventilation system operating was measured at C site (underground parking lot). In general, all pollutants were maintained below indoor air quality maintenance standards. The indoor air quality at indoor parking lots was affected by the availability of the ventilation facility and their operation frequency. At the underground parking lot (C site) with ventilation system, TVOC concentration according to ventilation system operating were found to be lower operating (488.2 ${\mu}g/m^3$) than non-operating (1,401.2 ${\mu}g/m^3$).

Effects of Emission from Seoul Metropolitan Area on Air Quality of Surrounding Area Using MESOPUFF II Model (MESOPUFF II모델을 이용한 서울시 $SO_2$배출량이 주변지역 대기질에 미치는 영향 분석)

  • 조창래;이종범
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.6
    • /
    • pp.563-576
    • /
    • 1998
  • To study the influences of the emission sources during lune 13∼15 1997 in Seoul, MESOPVFF II model has been used. The MESOPVFF II model includes terrain effects, chemical transformation and removal processes. Data of 20 surface meteorological stations and the upper air station on mid-west area in Korea were used as a DWM (Diagnostic Wind Model) input data. This model is likely to be applicable because the predicted SO2 concentration was well matched with measured 502 concentration in Seoul and Kyonggido. In generally air pollutants in Seoul have major influence on the other cities but the result of modeling appeared also air pollutants of the other cities influence on Seoul. Finally, in the case of calculating the air quality by diffusion model, the influences of air pollutants emitted in metropolitan area as well as the emission rate in modeling area should be considered.

  • PDF

Calculation Method for the Concentration of Persistent Organic Pollutants (POPs) Collected by Passive Air Samplers (수동대기채취기를 이용한 잔류성유기오염물질의 농도산정)

  • Choi, Sung-Deuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.2
    • /
    • pp.217-227
    • /
    • 2013
  • Passive air samplers (PAS) have been developed since the early 2000s and widely used for the atmospheric monitoring of persistent organic pollutants (POPs). PAS are useful especially for the investigation of source-receptor relationship of POPs because they provide higher spatial resolution data. In Korea, however, only a few research groups have conducted POPs monitoring using PAS. One of the reasons for the limited application of PAS might be due to a complicated calculation method for air concentration. In this study, therefore, we introduced the principle of polyurethane foam (PUF)-PAS, which has been most widely used in the world, and provided an example of the calculation of air concentration of polycyclic aromatic hydrocarbons (PAHs). As all data tables and equations for this calculation were provided, this method can be used for the conversion of the amount of POPs (ng) in a PUF disk to air concentration ($ng/m^3$).

Variation of Concentration of Air Pollutants with Air Mass Back-Trajectory Analysis in Gyeongju (기단 역궤적분석에 의한 경주시 대기오염물질의 농도 변화)

  • Kim, Kyung-Won;Bang, So-Yung;Jung, Jong-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.162-175
    • /
    • 2008
  • Gyeongju, which was the central city of the ancient civilization at Silla Kingdom, has various kinds of stone cultural properties. It is significantly important to preserve historical sources of Korea. However, recent air quality data measured in Gyeongju did not show good air quality level. In order to investigate variation of the concentration of the air pollutants with meteorological condition, an air quality monitoring and an aerosol sampling were conducted during the intensive monitoring period in Gyeongju. Impacts of the meteorological factors on the air pollutants were also analyzed based on the air mass pathway categories using HYSPLIT model and the local wind patterns using MM5 model. The prevailing air mass pathways were classified into four categories as following; category I affected by easterly marine aerosols, category II affected by northwesterly continental aerosols, category III affected by southwesterly continental aerosols, and category IV affected by northerly continental aerosols. The concentrations of the air quality standards were relatively lower during the fall intensive monitoring period. At that time, the easterly marine air mass pattern was dominated. The seasonal average mass concentration of $PM_{10,Opt}$, which optically measured at the monitoring site, was the highest value of $77.6{\pm}28.3\;{\mu}g\;m^{-3}$ during the spring intensive monitoring period but the lowest value of $20.1{\pm}5.3\;{\mu}g\;m^{-3}$ during the fall intensive monitoring period. The concentrations of $SO_2$ and CO were relatively higher when the air mass came from the northwestern continent or the northern continent. The concentrations of ${SO_4}^{2-}$ and ${NO_3}^-$ increased under the northwesterly continental condition. It was estimated that the acidic aerosols were dominated in the atmosphere of Gyeongju when the air mass came from the continental regions.

A Spatial Analysis of the Causal Factors Influencing China's Air Pollution

  • Kim, Yoomi;Tanaka, Katsuya;Zhang, Xinxin
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.194-201
    • /
    • 2017
  • This study investigates the factors that affect China's air pollution using city-level panel data and spatial econometric models. We address three air pollutants ($PM_{10}$, $SO_2$, and $NO_2$) present in 30 cities in China between 2004-2012 using global OLS and spatial models. To develop the spatial econometric analysis, we create a spatial weights matrix to define spatial patterns based on two neighborhood criteria - the queen contiguity and k nearest neighbors. The results show that the estimated coefficients are relatively consistent across different spatial weight criteria. The OLS models indicate that the effect of green spaces is statistically significant in decreasing the concentrations of all air pollutants. In the $PM_{10}$ and $SO_2$ analyses, the OLS models find that the number of buses and population density are also positively related to a reduction in the concentration of air pollutants. In addition, an increase in the temperature and the presence of secondary industries increase $SO_2$ and $NO_2$ concentrations, respectively. All spatial models capture a positive and significant effect of green spaces on reducing the concentration of each air pollutant. Our results suggest that green spaces in cities should receive priority consideration in local planning aimed at sustainable development. Furthermore, policymakers need to be able to discern the differences among pollutants when establishing environmental policies.

APPLICATION OF A PILOT-SCALE FLUIDIZED-BED REACTOR FOR THE DECONTAMINATION OF GROUNDWATER

  • Ohlen, Ken;Lee, Seong-Taek;Hegemann, Wemer;Jang, Yong-Geun
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.77-80
    • /
    • 2001
  • Groundwater, contaminated predominantly with aromatic compounds and chlorinated ethylene, could be biologically treated in a fluidized-bed reactor with immobilized cells. The decomposition efficiency for the aromatics was over 90% at the retention time of 2.5 h. The chlorinated ethylenes, especially trichloroethylene (TCE) and cis-dichloroethylene (DCE), could be decomposed only insufficiently. No anaerobic methane formation was observed for this groundwater even at a very low dissolved oxygen (DO) concentration of 0.75 mg/L. The variation of DO concentration resulted in an optimal value of 1.5 mg/L. The recycle of air waste could increase the utilization of oxygen. The amount of low boiling pollutants stripped out remained constant with the recycle, while for the higher boiling pollutants the stripping slightly increased. Using air instead of oxygen increases the flow rate of air waste, which is connected to a higher stripping of pollutants. In this investigation, the pollutant concentration in the air waste remained constant. The stripping of main pollutants did not exceed 0.3 %.

  • PDF

The influence on air quality of the surroundings by the facility of the district heating (집단 에너지 시설에 의한 주변 대기질 영향)

  • 연익준;주소영;이민희;손종렬;김광렬
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.18-25
    • /
    • 2002
  • The comparison of the air quality with the evaluation of the environmental assessment before and after operations of the heat source and of the flue-gas desulfurization facilities were studied. First of all, several sites were selected for the representative sample points, and then they were examined air quality of the surroundings. The results were that TSP(total suspended particulate) analysis after an operation of the heat source facility was $74~81{\mu}g/m^3$, PM-10 was $31~94{\mu}g/m^3$, and $SO_2$concentration was 0.002~0.009ppm, respectively. As the result of examination to the concentrations of diffused pollutants, there was no relations between TSP concentration of sample points and the effect of air quality according to the heating source. When we compared the neighbored area of the heating source with the other area, the concentration of air pollutants after an operation of the facility of the heating source was similar to the heating source, the neighbored area, and the other area. So we concluded that there was no the effect of the air pollution by producted pollutants from the heating source.

A Study of Concentration Prediction of Automobile Air Pollutant Near the Highway (자동차 대기오염물질이 고속도로 인접지역에 미치는 농도 예측에 관한 연구)

  • Park, Seong-Gyu;Kim, Sin-Do;Kim, Jong-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.6
    • /
    • pp.607-620
    • /
    • 1998
  • The influence of transportation on air quality has been elevating in urban area. Air pollutants from automobiles cause primary and secondary air pollution, and need to be tightly controlled. In this study, the effect of automobile air pollutants on highway vicinity area was evaluated by the comparison of field measurement. and target was for modeling using CALINE3, NO2 was the target for this work. It was found that the concentration predicted by CALINE3 is overestimated at low wind speed and input data of wind speed requires correction. Based on the measured data, the wind speed was modified by effective wind speed equation [Ue=U+0.24·EXP(-pxU)], and there after the accuracy of CALINE3 calculation was improved neighborhood area of highway. It was also observed that weather conditions and traffic volume affect the concentration of air pollution. Finally, the NO2 effect of automobile air pollutants on the vicinity area of highway proved to be up to 400∼600m from the highway.

  • PDF

A Comparative Analysis on Concentration of Pollutants in Housing Indoor-Air between Winter and Summer (주택 실내 공기중 오염물질 농도의 동절기와 하절기 비교 분석)

  • Nam, Ki-Cheul;Lee, Young-Han;Choi, Bong-Seok
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.125-131
    • /
    • 2017
  • Purpose: The study is to measure concentrations of indoor air pollutants in housing and to analyze the characteristics of pollutants in housing indoor-air between summer and winter comparatively. The research result could be used as data for public health through indoor air quality management of existing housing and more as a reference for new housing. Method: It was investigated 24 middle class housings of metropolitan area in winter which have been built for the past 30 years. Concentration of HCHO, TVOC was investigated in living room at morning and night and concentration of $CO_2$ was investigated in living room and master bedroom at morning and night. SKT100-X5 was used for concentration of HCHO, TVOC and ZGm053UK for concentration of $CO_2$. The characteristics of HCHO, TVOC, $CO_2$ concentration in winter were analyzed and then the concentrations in winter were analyzed the concentrations in summer being preceding research comparatively. Result: Average concentration of TVOC in winter was 2.7 times more than that of TVOC in summer, average concentration of HCHO in winter was about 2.0 times more than that of HCHO in summer. Average concentration of $CO_2$ in the morning at living room in winter was 1.3 times more than that of $CO_2$ in summer. Average concentration of $CO_2$ in the morning at master bedroom in winter was 1.1 times more than that of $CO_2$ in summer. Average concentration of TVOC was 1.31 times more than that of HCHO and standard deviation of that was 1.73 times higher. Average concentration of $CO_2$ was almost nearly close or over to 1,000ppm being criteria of the Ministry of Environment.

A Study on the Diffusion of Atmospheric Pollutants over Taegu (대구상공에서의 대기 오염 물질 확산에 관한 연구)

  • Yun, Il-Hui;Min, Gyeong-Deok;Park, Dong-Jae
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.241-252
    • /
    • 1994
  • Meteorological parameters In the atmospheric boundary layer and the vertical and horizontal dispersion parameters were determined by analyzing the data obtained by the special upper-air observations of one clear day for each season from October 1991 to August 1992. The concentration of the aklospheric pollutants over Taegu was analyzed by using the application of the Gaussian diffusion model. In the diurnal variation of diffusion of atmospheric pollutants, vertical diffusion due to turbulence is active in daytime while horizontal diffusion due to wind is active in nighttime. The mean concentration of pollutants in the side of downwind is higher during the daytime than the nighttime. Thus, the height of the mixed-layer at the nighttime considered as the most important parameter of the mean concentration of pollutants. In the seasonal variation of diffusion of atmospheric pollutants, vertical diffusion due to strong solar radiation is active in summer case day, and horizontal diffusion due to strong wind is active in winter case day. In winter case day, the mean concentration of pollutants in the side of downwind is maximum in the daytime. However, in summer case day, that is maximum in the nighttime.

  • PDF